Varian 3300 Gas Chromatograph Abbreviated Operating Instructions

Similar documents
6890 GC Not Ready Messages (A16010)

5890II GC Standard Operating Procedure 9/2/2005

CP-3800 GC Operator s Manual

no peaks missing peaks too small peaks increasing retention decreasing retention

Ghost Peaks: How to Fix a Haunting Problem. Jacob A. Rebholz Teledyne Tekmar VOC Product Line Manager

6850 Series Control Module User Information

Experiment GC : Analysis of BTEX by GC-FID

Retention Time Locking: Concepts and Applications. Application

CP-8400 AutoSampler and CP-8410 AutoInjector

User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection

Appendix: Simplified Instructions for Operating the HP 5890 GC/FID and Air Sampling Systems

Agilent Inlet EPC Leak Test

GCMSD-Headspace Analysis SOP

SOP: Buck Scientific BLC-20P HPLC Operation

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

Quick Reference Guide. OPTIC 3 - PTV on Shimadzu GC-2010 Gas Chromatograph

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

Simplified Backflush Using Agilent 6890 GC Post Run Command Application Note

3 Flow and Pressure Control

Gas Diluter Portable Gas Dilution System User s Manual

A SCENT OF FUTURE. Master DHS. Dynamic Head Space Sampler. Operating Manual

Using the Akta Prime plus October 22, 2012

Agilent 7890 Series Gas Chromatograph

Agilent 7697A Headspace Sampler

CP-3800 GC Getting Started Manual

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

Demystifying the Process of Calibrating your Thermal Desorption Gas Chromatography System using Compressed Gas Standards.

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Quantitative Analysis of Hydrocarbons by Gas Chromatography

Rapid and Reliable Detection of Dissolved Gases in Water

SSI Solaris 150 RTA Revision /27/2016 Page 1 of 9. SSI Solaris 150 RTA

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

ASTM WK Standard Test Method for Dissolved Gases. Anne Jurek Applications Chemist

ASTM 3612/TOGA/Dissolved Gas GC Revised October 2013

Agilent G3180B Two-Way Splitter Kit

Agilent G Rebuilt Electron Capture Detector

Instant Connect Helium Saver Injector Module

System Overview. TCD Detector temperature setpoint Regulator

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

A New GC/MS System Designed for Helium Carrier Gas Conservation

Considerations and Best Practices for Maintaining Your Agilent GC s Split/Splitless Injection Port

Agilent G3185B QuickSwap Accessory

Manual for continuous distillation

This GC has two columns (I think new columns can be ordered from Restek)

Optimizing Vial Pressurization Parameters for the Analysis of <USP 467> Residual Solvents Using the 7697A Headspace Sampler

Operation of the Perkin Elmer TGA-GC/MS

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

6890 GC Site Preparation

Equipment Operating Procedure Glove Box

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Time-Delay Electropneumatic Applications

Headspace Troubleshooting Made Easy. Presented today by: Susan Scheib Sr. Technical Support Specialist Joe Barta FSE Chicago & Escalation Engineer

Agilent 7667A Mini Thermal Desorber. Installation and Operation

SHIMADZU LC-10/20 PUMP

Agilent 6820 Gas Chromatograph

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

Agilent 7820A Gas Chromatograph

Multiple Gas#5 GC configuration Jan 2016

1. Study the performance of a binary distillation column operated in batch mode.

User s Booklet for the Wyatt minidawn Light Scattering Instrumentation

OFI MODEL 20 CONSTANT SPEED BLENDER INSTRUCTIONAL MANUAL

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

Agilent 1100 Series Analytical and Preparative Scale Fraction Collectors. User s Guide

Login to ilab Kiosk. Revised 05/22/2018. Load your sample:

CHM Gas Chromatography: Our Instrument Charles Taylor (r10)

Agilent 7697A Headspace Sampler

Using the PreVent System in Time-Saver Mode with the AutoSystem XL Gas Chromatograph and the TurboMass Mass Spectrometer

Mass Spec will not Autotune

CHE 4115 Chemical Processes Laboratory 2 Experiment 1. Batch Distillation

R E D I C O N T R O L S

- Repeat calibration until desired results are reached otherwise set SW2 and SW1-8 open.

Vapor Sorption Analyzer

FROG-4000 TM Chemical Analysis System

Advancements in Gas Chromatography Analyzers - Keeping up with New Technology. Chuck Runkle Gas Phase Product Specialist ASTS June 2013

Automated Determination of Dissolved Gases in Water Anne Jurek

Automated Determination of Dissolved Gases in Water By Headspace Calibration of Mixed Gases Anne Jurek

FAULT CODE TROUBLESHOOTING INDEX

SCF Softball Club Scoreboard Controller Operation

Automated Liquid Handling Station

BUBBLER CONTROL SYSTEM

Trion PECVD SOP IMPORTANT: NO PLASTIC, TAPE, RESISTS, OR THERMAL PASTE ARE ALLOWED IN THE CHAMBER

Agilent 6890N, Option 652 Oral Fluids Analyzer

A Column-Flow Independent Configuration for QuickSwap. Application. Authors. Abstract. Introduction

Burner Management System DEMO Operating instructions

FROG-4000 TM Chemical Analysis System

Air Quality 2b - PFGC/FID Analysis of Benzene and Toluene in Automobile Emissions

User Manual GRI- 1500Li

Standard Operating Manual

Prep LC Training Manual

Agilent ICP-MS Interactive Troubleshooting tool for Plasma ignition problem

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

3-Way Decoking Valve Option - Installation and Operation Instructions Accessory G Background

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Model 130M Pneumatic Controller

USER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

Stand-Alone Bubble Detection System

Notes-PECVD: Chamber 1

Warnings: Notes: Revised: October 5, 2015

MJB4 Mask Aligner Operating Procedure. Effective Date: 07/12/2012 Author(s): Jiong Hua Phone:

5000TOC Sensor Standard Operating Procedure for TOC Calibration Conductivity Calibration Temperature Calibration Flow Rate Calibration

Transcription:

Varian 3300 Gas Chromatograph Abbreviated Operating Instructions 1. Introduction and Startup 2 2. Basic Configurations for the GC 3 3. Sample Preparation 3 4. Building a Method 3 5. Split/Splitless Injection Valve 5 6. Making the Injection 5 7. Monitoring Instrument Status 6

2 1. Introduction and Startup [Brackets] denote a button on the instrument CAPS denote an instrument message on the display Turn on gas flows: He 80 psi H 2 40 psi Air 60 psi Turn on instrument with the master switch on the back left-hand side of the instrument. [Shift] [Instr Test] This command will run a series of tests including a display test as well as some internal tests. The display will show any error messages if any anomalies are discovered. If an error is discovered, it will be displayed as FAULT ## and the number can be looked up in Volume 2 of the manual in the trouble shooting section for further information. FAULT 12 refers to a low battery. The instrument s battery is dead and thus this message will always be displayed. After viewing the fault messages, clear them by pressing [Reset]. Pneumatics Panel inside the front door: Carrier Pressure on Column A: ~25 psi Injector (make-up?) flow: ~30 ml/min Detector (make-up?) flow:? Ignition of the Detector: (Make sure that the H 2 and Air are on) [Shift] [Ignite] and hold for about 5 seconds. If the status light flashes after this period, the error message is probably flameout which indicates that the detector did not ignite. To confirm this, remove the cover over the detector. You can check if the detector is lit in two ways: 1. Place a small vial of cool water over the detector chimney and see if condensation appears on the bottom. If it does, then the detector is lit. 2. Carefully place your finger over the top of the chimney. If the detector is lit you will not be able to hold your finger over it for more than a couple of seconds. It is important to confirm that the detector is lit before trying to run any samples. Do not depend on the error light to indicate whether or not it is lit. Instead, use one of the previous methods. Once the flameout error appears, press [Reset] and try to ignite again. Repeat these steps until you have verified that the FID is lit. To enter commands and parameters, you will use the entry keypad. Often a yes or no answer will be required. The display will show the currently selected answer. This can be changed by pressing either [yes] or [no] and then [Enter]. Numerical values are also entered via this keypad. [CE] clears your entry. [Prompt/Help] will display allowed values if you are unsure of what to enter. [Enter] enters the selected value.

3 2. Basic configurations for the GC [GC Configure] SET TIMES AND DATE? No. SET TEMP LIMITS? Yes. Enter the temperature limits for the column and injector. This varies according to what kind of column and injector is being used but 300 C is probably about right. These values limit how high the temperature can be set while building a program. There is no auxiliary device, so that temperature can be set at anything (35 C). Enter the temperature limit for the detector. Again this varies, but 350 C is probably about right. SET COLUMN STANDBY TEMP ENABLE COLUMN STANDBY TEMP? If the standby temp is enabled, then the instrument will return to the specified temperature between each run. I found this to be inconvenient as otherwise the instrument returns to the initial temperature of the program and is immediately ready for the next run, so I always chose No. SET CHECKS FOR GC READY? Yes. WAIT FOR INJ TEMP READY? Yes. WAIT FOR AUX TEMP READY? No. WAIT FOR DET TEMP READY? Yes. WAIT FOR EXT DEVICE READY? No. WAIT IF FAULTS PRESENT? Yes. INITIAL RELAYS AT END RUN? Yes. This tells the instrument to return to the initial conditions of the program after a run has been completed. SET LOCK CODE? No. TURN HARDWARE ON/OFF? No. OTHER CONFIGURATIONS? No. GC CONFIGURE TABLE COMPLETE 3. Sample Prep Prepare the sample: Create a very dilute solution of the sample to be analyzed in the proper solvent. The sample should be fairly clean to prevent heavy, stickier compounds from contaminating the injector and column. 4. Building a Method [Build/Modify] PRESS SECTION OR TABLE [Column] ENTER STARTING COLUMN TEMP Enter the initial column temperature. INITIAL COL HOLD TIME Enter how long to remain at the initial temperature in minutes after beginning a run. Enter 0 if no hold time is desired.

4 TEMP PROGRAM COLUMN? A no answer will give you a program that remains at the initial temperature for as long as you have set the hold time. A yes answer allows you to program up to four temperature changes into the program. If yes is selected: PRGM 1 FINAL COL TEMP Enter the final temperature of the first ramp. PRGM 1 COL RATE IN /MIN Enter the rate at which the instrument will go to the final temperature in /min. PRGM 1 COL HOLD TIME Enter how long to remain at the final temperature. ADD NEXT COLUMN PROGRAM? Yes will allow you to program another temperature ramp following the same steps. This can be repeated four times. A sample program follows: ------------------------------------------------ ENTER STARTING COLUMN TEMP. 100 INITIAL COL HOLD TIME 0 TEMP PROGRAM COLUMN? Yes PRGM 1 FINAL COL TEMP 150 PRGM 1 COL RATE IN /MIN 25 PRGM 1 COL HOLD TIME 0 PRGM 2 FINAL COL TEMP 210 PRGM 2 COL RATE IN /MIN 10 PRGM 2 COL HOLD TIME 0 PRGM 3 FINAL COL TEMP 220 PRGM 3 COL RATE IN /MIN 1 PRGM 3 COL HOLD TIME 0 PRGM 4 FINAL COL TEMP 250 PRGM 4 COL RATE IN /MIN 10 PRGM 4 COL HOLD TIME 5 ---------------------------------------------------------- INJECTOR TEMP Enter the temperature for the injector. Make sure this temperature is high enough to make the vaporization of the sample fast and complete. INITIAL AUX TEMP INITIAL AUX HOLD TIME There is no auxiliary device so these parameters do not matter. TEMP PROGRAM AUXILARY? No. DETECTOR TEMP Enter the temperature for the detector. As a general rule this temperature should always be 50 higher than the highest column temperature. FID B INITIAL ATTEN This sets the attenuation of the detector. This value must be between 1-1024 in powers of 2. FID B INITIAL RANGE This sets the range of the detector. This value must be between 8-12. AUTOZERO ON? TEMP PROGRAM FID B? INITIAL RELAYS Yes. No. -1 (off)

5 I am unsure as to what this parameter does, but it seemed to work well with this setup in my research. ( 1 and 1 refer to on and off) PRGM 1 RELAY TIME IN MIN I believe this is when the split injection mode is being utilized. I think that the time in minutes that is entered is the amount of time the instrument waits to purge the injection chamber during the injection. A setting of 0.1 minutes tells the instrument to wait 6 seconds after injection before purging the chamber. Using this means that a larger and thus more reproducible injection volume (1 µl) can be used without overloading the column. PRGM 1 RELAYS 1 (on) ADD NEXT RELAY PROGRAM? No. METHOD COMPLETE-END TIME ##.## The total running time of the method will be displayed at this point. To make a new program or modify an existing one: [Delete Program] SELECT SECTION [Column] ENTER PROGRAM NO TO DELETE Select which program (1-4) to delete. It may be easier to delete the entire program. PROGRAM DELETED To delete an entire program: [Delete Section/Table] SELECT SECTION PROGRAM DELETED [Column] 5. Split/Splitless Injection Valve The split/splitless injection valve that is installed on the GC is set to run in the split mode. This means that a large percentage of the sample volume that is injected is purged from the chamber. The percentage of sample is controlled by turning the valve which is directly in front of the injection ports. When the valve is turned all the way counter clockwise, this is set for the smallest ratio (the largest amount of sample enters the column). If the valve is turned all the way clockwise (8 turns), it is set at the highest ratio (the smallest amount of sample enters the column). I found that for a dilute sample and a 1 µl injection volume, 7 turns clockwise seemed about right with an attenuation of 256. 6. Making the Injection Rinse the syringe several times with the solvent you are using. Then rinse the syringe several times with your sample. Fill the syringe with about 3-4 µl of the sample solution. Invert the syringe and expel all but 1 µl of solution. Carefully insert the needle into the center of the injection port. You will feel resistance as you pass through the rubber septum. The injector port is equipped with a starter switch that is activated as the syringe comes in contact with the injector. As soon as the starter switch is activated,

6 inject the sample quickly and withdraw the syringe. Injecting too slowly can cause broad peaks. At this point the instrument will begin the programmed run. At any point during the run you can toggle between the elapsed and remaining time and the current temperatures by pressing [Enter]. It is also possible to make adjustments to the program while it is running such as adding or subtracting a hold time to allow something to fully elute. This is done by following the exact same procedures as before. As long as the event you are changing hasn t happened or isn t finished happening and the change will not result in a shorter run time than is already elapsed, the change will take effect immediately. Otherwise the program will return to the beginning. A run can be stopped at any point by pressing [Reset] and the conditions will return to the initial settings. Remember if you stop the program in the middle to allow enough time for everything to elute before attempting another run. Once the program finishes running, the conditions will return to the initial ones and then the instrument will go through a stabilization period. This can be monitored by pressing [Status] during this period. 7. Monitoring Instrument Status If the instrument is in RUN, the run time can be displayed by pressing [Status] and [Enter] to display the method number, the instrument state, the elapsed run time and the end time. A blinking STATUS light indicates a fault condition. When the light is blinking, press [Status] to display the fault message followed by [Enter] to display any additional messages. Refer to Troubleshooting in Vol. 2 of the manual to determine what the fault numbers are. Clear fault messages by pressing [Reset]. If the instrument is NOT READY, [Status] may be pressed to display the not ready conditions which exist. Setpoint errors indicate that the value of a parameter is out of tolerance. Instrument states READY: The READY light is on and the GC is ready for injection. All parameters are within acceptable limits, the plotter is available and no error conditions exist. NOT READY: The NOT READY light is on and there are not ready conditions which exist. Press [Status] to display these. STABILIZE: The time when the last temperature zone is within its tolerance and the instrument allows 2:00 (or as set during configuration of the table) to check that all parameters are steady. If any value goes beyond tolerance during this time, the stabilization time is reset. Pressing [Reset] during this time will skip it and move directly to READY. Pressing [Status] will allow you to monitor the stabilization time remaining. RUN: The state at and after injection until the method end time or [Reset] is pressed.