INSTRUCTION MANUAL. Automatic Water Softener System. Model: PSE-08. Xsential Water Filtration Systems

Similar documents
Installation and Instructions 2. Product Features 3-6. Key Pad Functions 7. Distributor Information Programming Guide 8. Master Programming Guide 9-14

DRS4-RM Manual. Set Up Instructions for DRS4 Series Single Tank

Easy Nest Kits. Installation Suggestions

The ultimate in water softening

Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter. Visit us online at.

NORMAL OPERATING DISPLAYS GENERAL OPERATION

Autotrol Performa ProSoft

O&M Receiving and Inspection. Storage of Water Treatment Media

A4s Operation Manual

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Performa Cv Twin Alternating and High Flow Systems. Manual Supplement

Duplex Commercial Softeners

CCT-7320/ROC-2313 Reverse Osmosis Controller

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

Commercial Softeners. Installation, Operation & Maintenance Guide. Manual 002.1

AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

Roller AC Servo System

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

BI-680 Online Dissolved Oxygen Controller Instruction Manual

265 Series Valve Operation Manual

SOFTENER D-DF & D-UF Series

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

UsER manual for Watersens ph -REDOX

Reverse Osmosis System Installation Guide and Operation Manual.

Chloramines Removal Filter CLF20 and CLF35 Models

FAULT CODE TROUBLESHOOTING INDEX

ACV-10 Automatic Control Valve

AHE58/59 AC Servo System

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

WATER CONTROL SYSTEM QUICK START

Aquavar SOLO 2 Frequently Asked Questions

Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale

SPECIFICATIONS APCEPH1

VERTICAL AIR COMPRESSORS

ACTIVATE YOUR WARRANTY BY REGISTERING YOUR PRODUCT AT

Autotrol Performa Filter Valve Series

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

OC Panel High Limit Aquastat Kit, Manual Reset p/n

Iron Filter Installation / Operation Manual

VERTICAL AIR COMPRESSORS

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

Prestige Water Equipment Ltd.

E L E C T R O N I C S X T

WATER SOFTENER. Instructions Manual Use and Maintenance

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Series 180. Commercial/Industrial Control System Installation, Operation and Maintenance Manual

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

Qi Litre Ultrasonic Cleaner

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

Manual of SF6 Comprehensive Tester

INSTALLATION & START-UP INSTRUCTIONS. Clack WS1 & WS1.25 METER WATER SOFTENER SYSTEMS

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

MiniMag. 1 of 8. The MiniMag scrubber s 2 recover drain are 80% larger than a 1.5, making the MiniMag scrubber s drain hose less likely to clog.

LINEGUARD UF-100 compact water systems point-of-entry

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

NGP-250/500 Nitrogen Generator Quick Start Guide

BUBBLER CONTROL SYSTEM

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

Instructions for SILEX 1C Mixed bed cartridge filter

accidents which arise due to non-observance of these instructions and the safety information herein.

H.T.S.T. EQUIPMENT TEST PROCEDURES. Field Reference. Sequence of Testing. Pasteurizer Not Operating 3, 1, 4, 2, 7, 10, 8, 5B, 5E, 5C (dual stem), 9

Hurlcon KX Siesta Above Ground Salt Water Chlorinator by AstralPool Australia

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Softeners Clack Model V125DTH Medical / Industrial Series Operation and Service Manual

Reflow Oven HHL3000 INSTRUCTION MANUAL POHUA - jedyny autoryzowany przedstawiciel w Polsce

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Municipal Boost w/pre-treatment Monitoring System K-A-MCB-PRE

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

Stand-Alone Bubble Detection System

Remote Control Bait Boat

Installation of Your SprayMaster System

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

OWNER S MANUAL NMB SERIES

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT

Touch Screen Guide. OG-1500 and OG Part # T011

Instruction Manual for Configura Cushionair Portable Pump

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

Installation Operation Maintenance Manual

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

MP15 Jockey Pump Controller

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

ECL Comfort 110, application 131 (valid as of software version 2.00)

Prestige Water Equipment Ltd.

RAM Operation Manual

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

OPERATING INSTRUCTIONS Pressure Control System PCS-20 through PCS-100

LENNOX SLP98UHV DIAGNOSTIC CODES

AutoChanger Installation & User Guide Issue 2

BUBBLER CONTROL SYSTEM

Page INDEX SAFETY INSTRUCTIONS... 2 HOW YOUR AQUASPHERE CHLORINATOR WORKS... 3 AQUASPHERE CHLORINATOR OPERATION... 4 CONTROL PANEL FUNCTIONS...

CircuFlow Quick Setup Guide

Transcription:

INSTRUCTION MANUAL Automatic Water Softener System Model: PSE-08 Xsential Water Filtration Systems 78 Daly Street Ascot Western Australia 6104 Ph: 1300 366 295 Fax: (08) 9277 2266 www.xsential.com.au

Welcome to use Xsential mini water softener system Thank you for choosing Xsential mini-series water softener system. We hope that this system can provide you years of service and bring more enjoyment to your home life. Before using the new softener system, please read the operating instructions carefully. Should you be engaged in any problems which cannot be solved by this guide, please contact Xsential distributor. Functions The specific self-maintenance functions of Xsential water softener system can recover the soft water treatment performance for the whole system periodically. Therefore, it has long-term, stable softening function, without frequent replacement of the filter, greatly reducing the operating costs. This system can be in parallel or series according to the different requirements, to increase water production, or further enhance water quality Note: To ensure our products can be used for serving your interests at once, please make sure all other devices(connector, valve, faucet and so on) are firmly connected and in good condition. CONTENT FOR USERS 2 SYSTEM COMPONENTS 2 PLACE TO INSTALL 2 SYSTEM INSTALLATION 3 TECHNICAL PARAMETERS 4 LANGUAGE SELECTION 4 GENENRAL OPERATIONS 4 TIMER SETUP 5 SYSTEM TROUBLESHOOTING 11-1 -

FOR USERS The customers are suggested to learn about the quality of raw water before using our system. In some circumstances, if you apply our system to the raw water which far exceeds the standard water quality for residential, some pollutants in the water (e.g. manganese and other heavy metal ions) may poison the process agents in the system and cause you have to replace the process agents. The process agent in system cannot be out of water soak for long time. It will turn dry out and ineffective The process agent cannot work normally under the environment temperature beyond 1 C - 38 C Please ensure all the inlets and outlets turn open when the system is at work. SYSTEM COMPONENTS Controller The product applies the AMD valve controller for automatic control of the entire system. The daily maintenance for the entire system is simple and convenient, only need to select the operation on the control panel. Water Softener Body The pressure tank in the system uses the FRP and other corrosion-resistant materials as the principal, together with high quality, significant treatment effect of filter media, to complete the main task of softening process PLACE TO INSTALL The place where water softener system installed is very important. It needs to meet the following conditions: Horizontal platform or ground; Ambient temperature exceeds 34 F (1 C) and below 120 F (49 C); water pressure below 0.70MPa and above 0.14MPa; Stable power supply to the controller; The total length of the pipe connected to the water heater should be ten feet (three meters) at least, to prevent backflow of hot water into the system; The drainage point should be set as close as possible to the ground; Shut-off valve or bypass valve needs to be installed in the water pipe connecting points; Valve should be designed to meet the minimum deviation of the pipe center. the pipe cannot support the weight; Before the plastic valve is connected to the pipe, make sure all the pipes are welded completely and firmly. Outdoor site When the water softener system is installed outdoors, following notes must be paid attention: Humidity: rain may affect equipment performance. The system is not designed to undertake the excessive humidity and water spray from below. (e.g: continuous severe wet fog, corrosive environment, nozzle sprays upward) - 2 -

Direct sunlight: the materials of the product will fade under the direct sunlight, but the mechanism won t be reduced. If the controller has to be placed under sunlight, the protective cover should be placed on the whole unit. Temperature: the valve and controller will be damaged if the working temperature is too cold or overheated. The water in the valve will freeze if the temperature is below freezing, then lead to the physical damage of internal components and pipes. High temperature will affect the controller and the display may become hard to recognize, but the controller shall be on working. When the temperature comes back to normal working temperature, the display will return normal. Protective cover shall be helpful under high temperature circumstance. SYSTEM INSTALLATION THE FOLLOWING OPERATIONS SHALL BE CARRIED OUT BY PROFESSIONAL WORKERS Firstly, determine the system installation location Determine the all connection of PSE-08 (i.e. inlet, outlet, over flow drain, and waste water drain) Once the connection is known, connect the water supply to the inlet connection of the system. Connect outlet of PSE-08 to the appliance (the supply water pipe diameter cannot be smaller to than inlet pipe on controller to ensure the system provide the normal water production). The inlet and outlet pipes shall be installed with mechanical valve. The bypass valve is suggested to be installed between the inlet pipe and outlet pipe. Connect the waste water drain to the timer. Minimize the drain pipe length and corners, the distance between controller and drainage channel shall be less than 6 meters. An air gap between the drain pipe and the waste water drain is needed to prevent waste water from siphon back into the system. Connect the over flow drain to the waste water drain. Ensure an air gap is provided between the pipe and the waste water drain. DO NOT CONNECT THE WASTE WATER DRAIN AND OVER FLOW DRAIN TO SAME PIPE AT ALL TIME. Please do not install any valves in the drain pipes. Each pipe shall have its support point, the controller cannot bear the pressure and gravity. Ensure the electrical parameter of power supply is consistent with controller s data. Insert the power plug into the right socket. Warning: Do not use lead base solder to weld pipes, and do not use tools to tighten the plastic connector. It may break the connecting point due to the stress. Note: All the information described herein is as per commercial standards. Local regulation may require user to change the operation procedures as above, please check the local administration for accurate information before installation. - 3 -

TECHINICAL PARAMETER Integrated Under Cabinet Type Model Control System Regeneration Period Default Regeneration Time Inflow Water Quality Best Softening Flow rate Best Working Pressure Inflow Water Temperature Power Supply Volume of Regenerant Size of Inlet and Outlet Pipe Net Weight Dimension(L*W*H) PSE-08 AMD Electronic Controller 1~31 Days AM 2:00(Adjustable) Municipal Water, CaCO 3 450 mg/l 0.5 tons per hour 0.15~0.30MPa 1~38 220V AC / 50Hz 8 Kg 1/2 inches 11 Kg 360 200 485 mm LANGUAGE SELECTION 1). Language of PSE-08: Step 1: press both and at the same time for about 3-5seconds, there will be a new page appear on the screen Step 2: press for three times to choose the sixth item and then press to choose Step 3: press to choose the English and then press to confirm When there is no hourglass displaying on the screen Simultaneously press and to advance one cycle. When cam reaches next cycle, "C2" will be displayed. Repeat and to advance through each cycle(c1- C8). It would take about 3 minutes to finish. GENERAL OPERATIONS The water quality parameters of each water softener system are predefined, the user can choose depending on the specific circumstances. 1. Switch on power Turn on the power plug socket switch connecting to the system, switch on power, and you can hear controller motor starting to work. 2. Connect to water supply Firstly open the control valve of outlet pipeline, and then open the control valve of inlet pipeline. Then the water after softening treatment will supply to you continuously. - 4 -

3. Ensure self-maintenance function works After a period of work, the system will conduct automatic maintenance based on the set time. This procedure will consume regenerate. The user only needs to set the time and quantity to add recycling regenerate to the system to keep the water quality after treatment within the range of usage as required. TIMER SETUP Automatic control system requires a sustained and stable power supply. When the power failure happens for any reason in use, please reset system timer in order to ensure the system can work in accordance with the initial setup process. The control valve is Time type controller, when it reaches the setting time, the system will automatically start maintenance function.the control valve has big LCD display and implements menu styled control mode. It is user-friendly and the user can modify the parameters displayed on the LCD easily. Main Functions of Control Valve Electronic clock: Under the stand-by status, it functions as a clock. Automatic-regeneration: Washing cycle and time can be set. Manual regeneration: Manual regeneration can be implemented from the menu. Manuel mix water function: End user can adjust the proportion according to the specific requirement of water quality. Automatic meter preference: Meter delay mode will be selected automatically when the flow sensor was installed. Automatic memorizing: Setting information can be memorized when the power is off. Reset default: All current setting can be cleared and factory defaults can be restored by selecting the reset option. Failure protection: Motor protection, flow sensor failure alarm, positioning failure alarm. Highlighted characteristics Precisely position controlling: implement a precise regeneration process control through infrared detection. Large-scale LCD display(background light): All the operation information can be displayed. Three regeneration modes: time, meter immediate, meter delayed. - 5 -

Child Lock: All keys will be locked after 1 minutes during the stand-by status, press and hold for 3 seconds to unlock. MENU SET four keys control interface: key are used to choose or change all settings, SET button for setting or confirming, and "MENU" for entering menu or canceling. Controller Technical Parameters Maximized Hydrostatic Pressure: 20Kg/cm 2 Working Pressure: 1.38~7.0Kg/cm 2 Working Temperature: 0 ~39 Power Adapter: Input: AC100V~AC240V, 50Hz/60Hz; Output: DC12V Controller Functions and Operations 1. Controller Function Selection The system automatically detects Function Set Switcher and Flow Sensor when the system connects to the power supply: (1) Picture 1: No.1 and No.2 turns closed,the controller is water filter valve. Picture 2: No.1 and No.2 turns ON, the controller is water softener valve. (2) Picture 3: No.3 turns ON, the system program language is CHINESE; No.3 turns closed, the system program language is ENGLISH.? (3) When there is no flow sensor, default set for regeneration is meter delay mode. User can set other modes: meter immediate mode or time mode. - 6 -

When there is flow sensor, default set for regeneration is time mode. There is no display of other two modes in the menu. ON ON ON 1 23 1 23 1 23 Picture 图 1 1 Picture 图 2 2 Picture 图 3 3 2. System initialization The controller will enter the initialization status when it turns on. During initialization process, controller displays: System Initializing Please Wait 3. Stand-by status Under stand-by status,the controller displays: Time mode displays: Current Day/Time: xx-xx-xxxx xx:xx:xx Time of Next Regen: xx-xx-xxxx xx:xx:xx Meter mode display (for meter immediate and meter delayed): Current Day / Time is: xx-xx-xxxx xx:xx:xx Residual / Total Water xx.xxm3 / xxxx.xxm3 The accumulated water usage automatically goes back to zero when user restores defaults 4. Parameter Settings Under stand-by status,press MENU to enter menu setting interface. The menu display differently for 3 different regeneration modes, more details see menu demonstration. Selects the current setting category, the display will appears shadowed, press SET enters this setting. 1 Current Time setting Screen display: xx- xx xx xx:xx - 7 -

Press MENU to Return Press SET to Confirm The current setting appears shadowed, then press SET and enter next setting. Press MENU to cancel and return to the upper menu. Press SET to complete and save the setting. It will display: Setting Completed Press MENU to Return Now press MENU and returns to the upper menu. System will automatically exit and return to the stand-by status if there is no operations in one minute. And system will automatically resume the previous setting if there is no pressing "SET" to save the new setting. 2 Regeneration time setting Screen display: xx::xx Press MENU to Return Press SET to Confirm Default time of the regeneration is 2 A.M. For setting method, refer to 1 3 Regeneration cycle settings Screen display: xx days Press MENU to Return Press SET to Confirm Default regeneration cycle is 7 days For setting method, refer to 1 4 Regeneration meter setting Screen display: Capacity: xx:xxm^3 Press MENU to Return Press SET to Confirm Default meter standard is 06.00 m3 For setting method, refer to 1 5 Manual Stepwise Regeneration Screen display: Backwash Remarks: Filter valve only has backwash and rinse settings Brine Draw Rinse Refill The operating procedure is as follows: Select the item using key, the selected item displays shadowed. Press "SET" to confirm. - 8 -

Under backwash status it displays: Backwashing Any key to cancel Under this condition, press any key to stop backwashing, and system returns to the upper menu. If this condition stays 30 minutes without pressing any key, backwash will stop automatically and system returns to the stand-by status. Other status operation is as before. Under regenerations status (including manual stepwise regeneration, manual regeneration and system automatic regeneration), press any key can stop the process. When the system is returning to stand-by status, no key can be operated during this time and displays: Back to Service Please Wait 6 Manual Sequence Regeneration Screen displays: Regeneration Any key to cancel XX% Regeneration process is as follows: Backwash: System backwash duration according to the settings. (default setting is 20 minutes), enter the next process after finished. System Brine Draw: System brine draws duration according to the settings. (default setting is 50 minutes), enter the next process after finished. Rinse: System rinse duration according to the settings. (default setting is 15 minutes), enter the next process after finished. Refill: System refills according to the expected time. (default setting is 10 minutes), enter the next process after finished. Service: System returns to the service when the entire regeneration process completes. In the regeneration process, press and hold any key for 3 seconds to stop regeneration and system goes back to service status. 7 Advanced Settings Backwash Duration Brine Draw Duration (filter valve does not have this option) Rinse Duration Refill Duration (filter valve does not have this option) Regeneration Mode Load Default - 9 -

Operating procedure is as follows: Select the item using key, the selected item displays shadowed. Press "SET" to confirm, press Menu to back to upper menu. Choose the backwash duration, it displays: xx Minutes Press MENU to Return Press SET to Confirm The minutes glittering and shadowed display previous setting time, use key to change the setting, press "SET" to save and confirm, it will display: Setting is Completed Press [MENU] to Return Press MENU to exit and go back to the upper menu. System will automatically exit and return to the stand-by status if there is no operations in one minute. And system will automatically resume the previous setting if there is no pressing "SET" to save the new setting. Other duration setting is same. When it comes to the setting time for regeneration, the system will run according to setting time by Advanced Settings and steps by Manual Sequence Regeneration. The programmable regeneration time and regeneration cycle start to run, the system will generate according to both duration setting and manual regeneration procedure from advanced settings. Press any key to stop regeneration and the system goes back to stand-by status. 8 Regeneration mode time meter immediate meter delayed Operating procedure is as follows: Select the item using key, the selected item displays shadowed. Press "SET" to confirm press Menu to back to upper menu. After Choosing meter immediate mode, when water consumption reaches the setting amount (default value is 06.00tons), the system will execute a circle according to manual sequence regeneration setting. Press any key for 3 seconds to cancel regeneration, the system will return to stand-by condition. Choosing meter delayed mode, after water consumption reaches the setting amount (default - 10 -

value is 06.00tons),and when it reaches the setting time for regeneration, the system will execute a circle according to manual sequence regeneration setting. When the circle ended, the residual water under stand-by status will be initialized automatically (restore user s set-up of water volume for regeneration cycle, default setting is 06.00 tons). Press any key for 3 seconds to cancel regeneration, system will back to stand-by status and returns to the normal service. 9 Reset Default The factory default value will be restored if Load Default was chosen Resume the default Press [MENU] to cancel Press [SET] to confirm The factory default value is: Regeneration time: 2 a.m; Regeneration cycle: 7 days Regeneration duration: Backwash: 20minutes Brine Draw: 50mintues Rinse: 15minutes Refill: 10minutes For meter immediate and meter delayed mode, the default meter is 6.00 tons. SIMPLE TROUBLESHOOTING Xsential Products are efficient and durable. In case of failure during use, the following simple troubleshooting list can work as a reference. Before repairing, the water and pressure inside the system have to be discharged firstly. Problems Analysis Solution A. Power shut-off or the power A. check power supply to ensure the adapter dis-connect stable power supply No display on controller B. Power adapter failure B. contact distributor to replace adapter C. Circuit board of controller failure C. contact distributor to replace Circuit board A. controller internal is clogged A. disconnect the power adapter and Controller valve display B. software failure connect again "system under maintenance" C. controller valve failure B. same as above C. contact distributor A. controller valve restoration failure A. disconnect the power adapter and Water drains cannot be B. Power shut-off when the system connect again stopped is under regeneration B. switch the bypass valve to bypass or C. controller valve failure close the controller valve inflow water C. contact distributor Water refill cannot stop A. refill time setting is too long A. Reset refill time - 11 -

The output water is salty The output water after treatment is still hard B. Power shut-off during water refilling C. controller valve failure A. Regeneration time setting unreasonable B. Timer does not work normally C. the brine valve is clogged D. the water pressure is too low A. The inlet water quality exceeded the specification of which the softener can handle B. the controller timer does not set properly C. pressure in the water supply system is too high or too low D. the bypass valve does not set correctly E. Short of salt in the tank F. controller valve failure B. switch the bypass valve to bypass or close the controller valve inflow water C. contact distributor A. increase rinse time and manually operate rinse once B. change timer C. clean up or replace brine valve D. pump up the water pressure A. contact local authority for detail of water quality B. shorten the re-generation cycle time or manually operate the sequence regeneration procedure C. add appliance to stabilize the pressure D. close the bypass valve E. fill up salt F. contact distributor - 12 -