Installation. S19-300T (top supply) S19-300B (bottom supply)

Similar documents
Installation. Heat Trace Combination Drench Shower and Eyewash Unit (includes 120 V and 208/240 V versions) S19-304GA

Installation S Gallon Tank (ASME rated) with Eyewash and Hose Spray

Installation S S19-788LHS

PEDESTAL MOUNTED EMERGENCY EYE & EYE/FACE WASH

Model PSI Compressor with 3-Gallon Air Tank 12VDC

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

WALL MOUNTED EMERGENCY EYE & EYE/FACE WASH HAND OPERATED

Halsey Taylor Owners Manual STOP!

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

100C Air Compressor Kit

Emergency Shower & Eyewash. Training Guide

V43 Pressure Actuated Water Regulating Valve

200 PSI COMPRESSORS - MODEL NUMBERS

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Booster Pump PB4-60 Replacement Kits

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

IMPORTANT SAFETY INSTRUCTIONS

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Installation Instructions

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

Combination Air Valve

8320 AXION MSR COMBINATION EYE / FACE WASH & DRENCH SHOWER

Emergency Eyewash & Shower Testing Program

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

1.0 PURPOSE 2.0 SCOPE 3.0 DEFINITIONS. ANSI: American National Standards Institute. CCC: Chemical Control Centre

SPECIFICATIONS ATTENTION

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Scald Protection Three-Way Thermostatic Mixing Valve

EMERGENCY EYEWASH & SHOWERS

O&M Receiving and Inspection. Storage of Water Treatment Media

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM

ANSI / ISEA Z Compliance Checklist

444C DUAL PERFORMANCE VALUE PACK

Model Portable Eyewash

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

PAGE (Rev. A - 06/17)

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

Operating Instructions

Geotech 1.66 Auto-Reclaimer

BPB26-1 AND SSPB26-1 PATIO BASE INSTALLATION INSTRUCTIONS

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE

Standards of Practice Emergency Shower/Eyewash Installation, Use, Testing & Maintenance

Laboratory Safety Guideline Emergency Eyewash and Safety Showers

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Speed control assembly model A-1

Aquor House Hydrant V2

ANSI / ISEA Z Compliance Checklist

CO2 Tank Conversion Kit P.N , P.N , and P.N

TECHNICAL INSTRUCTIONS

SWIRLFLO Refrigerated fountains with FLEXI-GUARD

Model TWBS.SH Tempered Water Blending System

Geotech 1.66 Reclaimer Installation and Operation Manual

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

36H SERIES Combination Gas Valve

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

Shut-Off Valves and Valve Boxes

Geotech 1.66 Reclaimer

400C & 450C DUAL PERFORMANCE VALUE PACKS

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Constant Pressure Crude Oil Container Model CPCCP

453 Series Steam Heated Vaporizing Regulator

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

Model 9201E Tempered Water Blending System

Scald Protection 3-Way Thermostatic Mixing Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Geotech 1.66 Auto-Reclaimer Installation and Operation

Geotech 3.5 Reclaimer Installation and Operation Manual

Steel Spring Driven Reel Instruction Manual

Related Products: Auto Drain Valve. Model/Specifications. Model

Installation, Operation and Maintenance Manual for Back Pressure Regulator

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

Design Requirements for Eyewash and Safety Shower Units

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Model Series 62 Constant Differential Relay

Instruction Manual Updated 7/26/2011 Ver. 2.2

DUAL 444C ONBOARD AIR SYSTEM

G96 Series BASOTROL Dual Operator Valve

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

Carter Option X Valve connector assembly. Maintenance manual

BP48-1 AND SSP48-1 IN-GROUND POST INSTALLATION INSTRUCTIONS

UltRo Dual Flow Reverse Osmosis Water System

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Installation and commissioning instructions 255 series and 256 series

BGA158 Series CE Approved Class A Shutoff Gas Valve

ANSI Z Compliance Checklist

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

DS05C,D,G Dial Set Pressure Regulating Valves

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

Pure Water Power Purification System 4-Stage RODI Operations Manual

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE. 4. TECHNICAL DATA Approvals:

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

Installation Troubleshooting Maintenance Instructions Installation / Start-up

Transcription:

Installation S19-300T (top supply) S19-300B (bottom supply) Heat Trace Combination Drench Shower and Eyewash Unit Class 1, Div. 1, Groups C & D (includes 120 V and 220/240 V versions) Table of Contents Pre-Installation Information... 2-3 Assembly of Components... 4 Installation... 5 6 Repair Parts List... 6 7 Troubleshooting... 8 2-1308 Rev. F; ECN 17-05-045 2017 Bradley Page 1 of 8 6/5/2017 P.O. Box 309 Menomonee Falls, WI 53052 USA 800 BRADLEY (800 272 3539) +1 262 251 6000 bradleycorp.com

S19-300T, S19-300B Class 1, Div. 1, Groups C & D Installation WARNING Flush the water supply lines before beginning installation and after installation is complete. Test the unit for leaks and adequate water flow. Main water supply to the unit should be "ON" at all times unless system is being serviced. Provisions shall be made to prevent unauthorized shutoff. Power supplied to the unit should be 120VAC or 220-240VAC, 50-60 Hz, amp branch circuit with a dedicated circuit breaker or fuse and should not supply power to any other device. Compliance and conformity to local codes and ordinances is the responsibility of the installer. Do not use this safety equipment in a location that does not match its hazardous location rating. Verify the appropriate ratings prior to installation. When making electrical connections be sure to follow all lockout-tagout safety procedures. CAUTION Emergency equipment must be supplied with tepid water (60-100 F/.6-37.8 C). Any prolonged exposure to near freezing water affects the body's ability to maintain body temperature, increasing the risk of hypothermia. The unit must be supplied with clean, potable water. NOTICE Before installing this product ensure that there are adequate clearances around the product and activation of the product does not interfere with other products or obstructions. It is recommended that all water supply and electrical connections be made at temperatures above freezing. Failure to do so may result in major product and/or property damage. Constant power supply to the safety equipment is necessary for it to function. Avoid cleaners containing organic solvents, alcohols and hydrocarbons. Rinse with potable water after cleaning. 2 6/5/2017 Bradley 2-1308 Rev. F; ECN 17-05-045

Installation S19-300T, S19-300B Class 1, Div. 1, Groups C & D IMPORTANT The installation and location of all safety drench showers, eye and eye/face washes must comply with the requirements of ANSI/ISEA Z358.1. Read this installation manual completely to ensure proper installation, then file it with the owner or maintenance department. Compliance and conformity to local codes and ordinances is the responsibility of the installer. Separate parts from packaging and make sure all parts are accounted for before discarding any packaging material. If any parts are missing, do not begin installation until you obtain the missing parts. Installation and maintenance of this system must be completed by a qualified plumber and electrician according to the information contained in this installation manual and in compliance with all national and local codes. The ANSI/ISEA Z358.1 standard requires an uninterrupted supply of flushing fluid. Bradley plumbed emergency fixtures require a minimum of 30 PSI (0.21MPa) flowing pressure. Flushing should be tepid per ANSI Z358.1 Weekly activation must be conducted on all plumbed emergency equipment to ensure a suitable flushing fluid supply is present and any sediment build up in the supply line is cleared. Inspect safety equipment monthly to address any maintenance issues ensuring the equipment is in good operating condition and that there are no signs of wear. Perform functional test upon relocation of safety equipment. The inspection and testing results of this equipment should be recorded weekly to verify proper operation. This equipment should be inspected annually to enure compliance with ANSI Z358.1. Workers who may come in contact with potentially hazardous materials should be trained regarding the placement and proper operation of emergency equipment per ANSI/ISEA Z358.1. For questions regarding the operation or installation of this product, visit www.bradleycorp.com or call 800-BRADLEY (272.3539). Product warranties and parts information may also be found under Products on our web site at bradleycorp.com. Bradley 2-1308 Rev. F; ECN 17-05-045 6/5/2017 3

P.O. BOX 309, MENOMONEE FALLS, WI 53052-0309 USA TEL: 1-800-BRADLEY FAX: (262-251-5817) http://www.bradleycorp.com 114-052 Date Datum Date R P.O. Box 309, Menomonee Falls, WI 53051 TEST THIS UNIT EACH WEEK DIESES GERÄT 1ST WÖCHENTLICH ZU PRÜFEN. ESSAI HEBDOMADAIRE Test-operate valve(s) each week and sign below. Report any malfunctions immediately. Ventil(e) wöchentlich im Testbetrieb prüfen, bestätigt durch Unterschrift. Jegliche Störung sofort melden. Test le fonctionnement des valves chaque semaine et signe en bas. S'il y à quelque chose qui ne va pas fait un rapport immédiatement. Signed Date Unterschrift Date Signe Date Signed Signed Signed S19-300T, S19-300B Class 1, Div. 1, Groups C & D Installation Components 11.11 11.12 11.1 Eyewash Assembly S05-171 11 Plastic Showerhead 12 Stainless Steel Showerhead Prepack S45-35 Eye/Face Wash Assembly S05-3 Heat Trace Unit Class 1, Div. 1, Groups C & D S19-300T (top supply) S19-300B (bottom supply) Pull Rod 128-6G Safety Sign 114-052 (qty. 2) Hex Nut #10-24 1-001 (qty. 2) Emergency Tag 204-421 Hook 1-001 (qty. 2) Screw #10-24 x 1/2" 160-245 (qty. 2) 4 6/5/2017 Bradley 2-1308 Rev. F; ECN 17-05-045

Installation S19-300T, S19-300B Class 1, Div. 1, Groups C & D Supplies Required (3) 3 8" floor anchors and bolts Teflon tape and pipe sealant Piping to 1¼" NPT water supply inlet on unit with adequate supply pipe supports Minimum 4" drain to accommodate 30 gallons per minute discharge for drench shower waste Electrical supplies to connect to unit junction box NOTICE! Bottom supply units have provisions for supporting the top of the unit. The 1-1/4" NPT solid pipe protruding from the shell must be used to support the unit. Junction Box ¾" NPT Hub 37¾" (959mm) 25¾" (654mm) Top Supply 1¼" NPT Secure unit to floor 1. Install three suitable anchors (supplied by installer) for 3 8" bolts in the floor. 2. Bolt the base to the floor anchors using 3 8" bolts (supplied by installer). 3. Install the pull rod to the unit as shown. 101 7 8" (2588mm) NOTICE! Do not rely on unit to support supply piping. WARNING! Unit requires a minimum 30 GPM to operate and a minimum 30 PSI of flowing water pressure. Preferred flowing water pressure is 40 60 PSI. Water supply to the unit must be freeze-protected (by others). NOTICE! Pipe size should be no smaller than 1¼" (supplied by installer). Connect water supply 19¼" (489mm) 60¾" (43mm) 85¼" (2165mm) 68" (1724mm) 92" (2337mm) 1. Connect the water supply piping to the 1¼" NPT inlet on the unit (piping by installer). Use pipe hangers or other means to provide adequate supports for the supply pipe (supports by installer). 2 Open water supply lines and test for leaks and adequate water flow. 43" (1089mm) 39½" (1004mm) 35½" (900mm) 9¾" (245mm) 6" (2mm) Assemble components 1. Install the showerhead to the unit as shown. The bottom edge of the showerhead should be 85¼" (2165mm) from the floor. 2. Mount the safety signs to the wall or to the unit if desired. Use the screws, nuts and hooks provided to hang the signs back-to-back on the unit. Ø 9" (229mm) Flange with (3) Ø 3 8" (10mm) Holes on a Ø 8" (203mm) Bolt Circle Bottom supply units must use this pipe for supporting unit. Bottom Supply 1¼" NPT Connect electrical supply 1. Connect the power to the junction box on the unit as shown in the schematic on page 4 (junction box accepts ¾" NPT conduit fittings). 2. Connect the optional alarm system and indicator light as shown. NOTE: Average power consumption of the unit is.7 amp/80 watts at 120VAC (.35 amp/80 watts at 220/240 vac) at 50 F (10 C) internal unit temperature. Refer to the installation instructions provided with the alarm system for more information. CAUTION Any electrical components supplied by installer must match the rating of the fixture to maintain its integrity. Unit is provided with sealing compound and conduit seals. Seals must be filled by installer prior to powering the unit per seal manufacturer's instructions. Use teflon tape only with plastic showerheads. Safety signs shown mounted back-to-back. ¾" NPT Junction Box opening Bradley 2-1308 Rev. F; ECN 17-05-045 6/5/2017 5

S19-300T, S19-300B Class 1, Div. 1, Groups C & D Installation al Alarm System Amber Lamp = Heater ON Green Lamp = Power TO UNIT Black Green White Black Alarm System Green White White A G Indicator Light Red Black Green Green Ground Screw-in Junction Box Power Supply Terminal Block Black Red Butt Splice Thermostat Heat Trace Cable Item Part No. Qty. Description 1 131-059 1 Base 2 219-040 1 Shell - Lower Left 3 219-030 1 Shell - Lower Right 4 219-027 1 Shell - Upper Left 5 219-041 1 Shell - Upper Right 6 269-1292 as req d. Edge Trim 9 269-51 1 Thermostat 10 S45-35 1 Hardware Prepack Plastic Showerhead (refer to page 2) 11 S24-188 1 Plastic Showerhead 11.1 S24-193 1 Shroud Assembly 11.11 187-053 1 Showerhead Shell 11.12 4-147 1 Ring Stainless Steel Showerhead (refer to page 2) 12 S24-191 1 Stainless Steel Showerhead Assy. 13 S27-301 1 Ball Valve, 1" with Nut (frost-proof) 13.1 110-214 1 Nut only 14 3-489 1 Adapter 161-036 6 Hex Nut, 5 16"-18 16 128-200 1 Handle 17 S21-068 3 Operating Stem 18 128-0 1 Handle 19 142-002DC 3 Lockwasher 20 128-6G 1 Pull Rod, 26" Item Part No. Qty. Description 21 S05-3 1 Eye/Face Wash Assembly 21.1 S05-2 1 Yoke, Drilled 21.2 S05-135 2 Eyewash Head 21.3 S53-063 2 Dust Cover, Tethered 21.4 113-1191 1 Stem 21.5 169-1069 1 Elbow ½" x 3 8" 21 S05-171 1 Eyewash Assembly 21.1 S05-170 1 Yoke, Drilled 21.2 107-371 2 Dust Cover, Tethered 21.3 S21-077 1 Stem 21.4 169-1069 1 Elbow Reducing ½" x 3 8" 22 S27-329 2 Ball Valve, ½" with Nut (frost-proof) 22.1 110-2 2 Nut only 23 3-372R 2 Ball Valve Adapter - R. H. 24 128-1 2 Handle Adapter 25 S08-383 2 Flag Handle - R.H. Assembly 25.1 114-049 2 Handle Label 26 269-1296 2 Hose Barb 27 S89-025 1 Hose 28 S45-1703 1 Valve, Freeze-Protect 29 S45-1702 1 Valve, Scald-Protect 30 269-1285 as req d. Rubber Tubing 31 124-048 1 Washer 6 6/5/2017 Bradley 2-1308 Rev. F; ECN 17-05-045

Installation S19-300T, S19-300B Class 1, Div. 1, Groups C & D 9 Junction Box and Thermostat (Item 9) apply to both top and bottom supplies. 13 31 14 13.1 Pull Rod Assembly 16 20 17 19 18 7 al Freeze and Scald Valve (for bottom supply) NOTE: Specify required length for Item 30 when ordering. 28 21.2 Eyewash 29 21.1 21.3 Flow control this end 4 11 10 5 30 26 21.4 6 Specify required length when ordering 21.3 21.2 22 22.1 21.1 21.4 21.5 Eye/Face Wash 2 3 1 23 24 27 17 25, 25.1 al Drench Hose 19 29 22.1 23 24 17 25, 25.1 Flag Handle 19 26 30 28 26 30 Freeze and al Scald Valve (for top supply) NOTE: Specify required length for Item 30 when ordering. Bradley 2-1308 Rev. F; ECN 17-05-045 6/5/2017 7

S19-300T, S19-300B Class 1, Div. 1, Groups C & D Installation Problem Cause Solution Low water flow at drench shower and eyewash Insufficient pressure Undersized supply piping Minimum 30 GPM required Increase pressure/pipe size Low water flow at drench shower or eye wash Freeze-protection valve is flowing water Debris in system Power supply is off [if the water temperature from the valve is below 45 F (7 C)] Water supply is too cold Disassemble the showerhead, clean and reassemble Unscrew the eyewash heads from the yoke, clean and reassemble. If still clogged, replace the heads. Turn the power on. Make sure the unit is supplied with tempered water. Defective thermostat [if the water temperature from the valve is below 45 F (7 C)] Defective freeze valve [if the water temperature from the valve is above 45 F (7 C)] Check continuity and replace if check fails activates at 50 F (10 C) (factory-set). Replace the freeze valve NOTE: A water supply that is at least 45 F (7 C) or colder will hold the freeze bleed valve open. To close the valve: 1. turn the water off temporarily or plug the valve until the heat trace unit s heat warms the valve 2. increase the surface temperature of the valve to above 45 F (7 C) by immersing the valve in hot water IMPORTANT: Make sure that the heat trace unit is operating properly before plugging the freeze bleed valve. A plugged valve will not provide backup freeze protection should the heat trace unit fail. Scald-protection valve is flowing water Defective scald valve [if the water temperature from the valve is below 80 F (27 C)] Direct sunlight or high ambient temperature Replace the scald valve. Cool the unit. Defective thermostat Check continuity and replace if check fails activates at 50 F (10 C) (factory-set). 8 6/5/2017 Bradley 2-1308 Rev. F; ECN 17-05-045