Amphenol. PowerLink Solar Cables. Amphenol 97 Series Connectors are UL recognized and CSA recognized.

Similar documents
Pro-Tekt European Cable System. Technical Catalog

INSTALLATION INFORMATION

Flex Cable Portfolio

MV-105 MEDIUM VOLTAGE CABLE. 5kV, 8kV, 15kV, 25kV & 35kV

Type MMV Medium Power Cable

PUR cable. PUR cable. The harmonised version H05BQ-F/H07BQ-F can be used at building construction areas and where HAR-approval is required in Europe.

Comtran Cable. Commercial Premise & Specialty Datacom Products. Cat 5e - Cat 6A. LSZH & Industrial Ethernet. Indoor/Outdoor & Outside Plant

TECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS

Electrical Tapes Selection Guide. 3Innovation

GENERAL APPLICATION NOTES

POWR-BLOKS Distribution/Splicer Blocks and Covers

SMARTen STP Patch Cords Features

PRODUCT INFORMATION ÖLFLEX ROBUST 215 C

YSLY-JZ YSLY-OZ. Low voltage - Energy, cabling, signalling and control

PRODUCT SPECIFICATION

Electronic Instrumentation

Baseline Two-Wire Technology

Halogen free cable. Halogen free cable

will not support combustion

Quick Reference Guide Power Series Switches

CABLE PULLING GUIDELINES

ENERGYPETROL S.A. Calle José Puerta N y Av. Eloy Alfaro - Quito - Ecuador Telf: (593)

COOPER POWER SERIES. 200 A 15/25 kv class elbow installation instructions. Deadbreak Apparatus Connectors MN650042EN

LECTRAFLEX CABLE AND WIRE. 46 Concentric jacketing provides consistent abrasion resistance

CY LSOH Screened Halogen Free Control Cables with improved fire performance

EPIC Rectangular Connector Inserts. HBE Series. Technical Data Number of Contacts:

Deep Submersible Level Transducer Series 300DS

Norrsken Family Booklet

ARMOR RODS Series 10000

COOPER POWER SERIES. 200 A 15/25 kv class deadbreak straight connector installation instructions. Deadbreak Apparatus Connectors MN650043EN

ibridge and ibridge Ultra

ASIC-Based Small Bore Submersible Level Transducer

SADACHAIN CY PUR 1000 V

SPECIFICATION FOR APPROVAL

APPENDIX D HYDRO-VAC

Type 715P/717P, Orange Drop, High Voltage, Polypropylene Film/Foil

WIREMOLD. Steel Raceway Systems. Low Profile, Single & Dual Channel Steel Raceway. Now compatiple with A/V Devices!

Pegasus Series Amphenol Pcd

SOLAR ENERGY. solutions. adhesives, sealants, and Potting encapsulants For solar energy applications

Portable Cordage. Table of Contents

Socket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11

Innovative Solutions for Building Safety & Security

powr-bloks POWR-GARD Fuseblocks Distribution/Splicer Blocks and Covers Applications Connectors Description Ampere Ratings Specifications

XIAMETER RSN-0997 Resin

Conductors. By far the largest and most important component of any earthing or structural lightning protection system is the actual conductor.

RTD Temperature sensor TH11

C-Line Electrical Connectors

Tolerance code. Lead space

Semoflex Roboschlepp The PUR cable for cable chains

Operating Instructions

DT400/436 Tee Connector Installation Instructions

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Instruction Manual for Intrinsically Safe - Reed Switches

CATALOGUE EXTRACT SIRCO PV. Disconnect switches for photovoltaic applications From 100 to 2000 A, up to 1500 VDC UL 98B & IEC

Modbus Submersible Level Transducer

COOPER POWER SERIES. 600 A, 15, 25, and 35 kv Class Cleer Grounding Elbow Installation Instructions. Loadbreak Apparatus Connectors MN650056EN

PANDUIT Copper Compression Metric Lugs and Splices

REMKE STYLE PowR-TECK CONNECTORS

Definitions for swimming pools, fountains, and similar installations in article 680

The easy, economical solution for Making wide-format Industrial Labels and Heat Shrink Tube Identification

$ Plan Review Fee when Permit Application is submitted HOT TUBS AND SPAS BUILDING PERMIT APPLICATION. COST: $80.

F series Foot Switches

Datasheet ANSI Standard Duplex Thermocouple Connector Sockets Types K, J, T, E, N, R/S & B (ANSI Colour Code)

ENGLISH Datasheet IEC Miniature Thermocouple Connector Socket with Stainless Steel mounting bracket Types K, J, T, E, N, B & Copper (IEC Colour Code)

Luminus Series Amphenol Pcd

FEATURES & BENEFITS. Prewired Raceway is prewired and packed to the job specifications at the factory before shipping to the jobsite.

200 A, 15 and 25 kv class loadbreak bushing insert installation instructions

Prewired position switches FA series

PSR-4000 HFX Series (UL Name: PSR-4000DE / CA-40HF)

Electrical Sensing Edges

Pegasus Series Amphenol Pcd

Diaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860

Table of Contents. Version 5.1. Mounting Hardware 9-10 Aluminum 9 Plastic 9 Plastic & Aluminum 10

COOPER POWER SERIES. DS250 deadbreak straight connector installation instructions interface A. Connectors MN650027EN

METROSIL CURRENT TRANSFORMER PROTECTION UNIT (CTPU) ENCLOSURES IEC COMPLIANT

RoHS. WS Series Snap Action Switch. Specifications. Part Number Configurator

Wet Tantalum Capacitors Tantalum Case with Glass-to-Tantalum Hermetic Seal CECC Approved

Synflex. Hydraulic Hose Quick Reference Guide

DESIGN CRITERIA DIVISION 4900 TRAFFIC SIGNALS

How to terminate an F/UTP CAT 6 cable with the LP-LRJ458P8CC6FS21 Plug.

Datasheet IEC & ANSI Miniature or Standard Quick Wire Thermocouple Connector Plug & Socket Type K in IEC or ANSI Colour code

LED Modules. Fortimo LED Line High Flux PR. 2ft 4000lm 1R NA

Position switches FP series

EASIDEW TRANSMITTER with Current Source Output

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Your Hot Tub Pre-Delivery Guide

Smart JVA Module WARNING. For use with AquaLink RS systems with rev R firmware or newer.

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

THE BEST SELECTION OF QUALITY TWIST-ON WIRE CONNECTORS UNDER ONE BRAND

Nottingham Township 909 Sugar Run Road Eighty Four PA (724) Fax (724)

MODELS (2 foot Version) (4 foot Version)

XMPA12B2142 pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type

Type 160 Metallized Polyester Radial Lead Capacitors

INDEX OF REVISIONS DESCRIPTION AND/OR AFFECTED SHEETS

EPIC Rectangular Connectors HBE Series

Datasheet ANSI Type K & T Exposed Welded Tip Thermocouples (ANSI Colour Code)

OTL Universal terminals

Outside Plant Fiber Cables. CommScope delivers proven innovation, inside and out

Plastic tubing, standard O.D.

S Surge Arresters

Transcription:

Amphenol PowerLink Solar Cables www.amphenol-industrial.com Amphenol 97 Series Connectors are UL recognized and CSA recognized.

PowerLink Solar Cables Amphenol s single conductor PowerLink Solar Cables are designed to be highly efficient, reliable, cost effective solutions for applications in harsh environments with extreme temperatures and rated for direct burial. PV, USE-2, and Thermoset cables are constructed with XLPE (cross-linked polyethylene) insulation and a tough abrasion-resistant jacket that resists sunlight, ozone, and UV radiation. Our PowerLink cables are proven solutions for any solar farm requiring reliable design and superior material construction. Conductors: Bare copper, tinned copper, or aluminum Certified UL 4703, TUV and dual rated UV/Ozone resistant Flexibility at low temperatures Thermoset-insulated conductor Long-term insulation resistant to moisture Voltage rating 600V, 1000V-2000V Temp rating (wet or dry) -40 C to +90 C Flammability VW-1, FT1 (UL1581, UL44)

PowerLink Single Jacket PV Cable The PowerLink Single Jacket PV Cable is designed for interconnection wiring of grounded or ungrounded photovoltaic power systems as described in section 690.31 (A) and other applicable parts of the National Electric Code, NEC, NFPA70, and RoHS compliant. Our superior single jacket design allows the outside of the cable to be smaller than a standard dual jacket PV cable. By using only one jacket the cable is narrower making the termination of a connector much easier. PowerLink Dual Jacket PV Cable The PowerLink Dual Jacket PV Cable is designed for interconnection wiring of grounded or ungrounded photovoltaic power systems as described in section 690.31 (A) and other applicable parts of the National Electric Code, NEC, NFPA70, RoHS compliant. Conductors: Bare copper, tinned copper, aluminum Sizes: 18AWG - 6AWG Stranding: 7 or 19 Insulation: XLPE (ASTM D2863) Colors: Black, white, red, blue, green, yellow, orange Voltage rating 600V 2000V Spark test 1500V 5kV Cold bend -40 C -40 C Flammability VW-1 VW-1 UL4703 rated, file #E327886 Conductors: Bare copper, tinned copper, aluminum Sizes: 18AWG - 6AWG Stranding: 7 or 19 Insulation: XLPE (ASTM D2863) white or black Jacket: PVC (ASTM D2863) black Voltage rating 600V 2000V Spark test 1500V 5kV Cold bend -40 C -40 C Flammability VW-1 VW-1 UL4703 type PV wire, file #E3227886 PowerLink USE-2 and Thermoset Cable The PowerLink USE-2 and Thermoset Cable is a single jacket cable used for lighting and power applications and may be installed in raceway, duct, direct burial, and aerial installations. The cable meets National Electric Code and other general purpose wiring applications. Satisfies USE-2, RHH, RHW-2 XHH, XHHW, XHHW- 2, RHW, RHW-2, RHH, R90, RW75, RW90, RWU75, RWU90. (UL), (cul), (culus). PowerLink Dual Rated Cable The PowerLink Dual Rated Halogen free photovoltaic cables are used as interconnecting wiring for photovoltaic power systems. This one cable is UL/ TUV rated. UL1581, IEC60332-1, IEC61034, IEC60754, EN- ISO4892, IEC60811-2-1, UL Sub 1703, UL4703 Type PV, 2PfG1169/08.2007, IEC61215, RoHS 2002/95/EC. Conductors: Bare copper, tinned copper, aluminum Sizes: 14AWG - 6AWG Stranding: 7 or 19 Insulation: XLPE (ASTM D2863) Voltage rating 600V 1000V Spark test 1500V 5kV Cold bend -40 C -40 C Flammability VW-1 FT-1 2000V also available Sizes: 8AWG - 14AWG Conductors: Tinned copper Stranding: Per TUV requirements Insulation: XLPE Jacket: XLPE Voltage rating PowerLink Dual Rated Cable Part Number AWG Voltage/Certification HCPBH2D1 14AWG 1000v TUV/1000v UL HCPBH4D1 12AWG 1000v TUV/1000v UL HCPBH6D1 10AWG 1000v TUV/1000v UL HCPBH8D1 8AWG 1000v TUV/1000v UL Call your local rep for additional PowerLink dual rated cable part numbers 1000V (TUV) / 600V (UL) 1000V (TUV) / 1000V (UL) Spark test 6,000 VAC 10,000 VAC Flammability VW-1, (UL1581, UL44)

UL File Number - Type - Voltage Chart Product line Type UL File No. Sub Type Testing Mark Standard(s) Ins. mils* Jacket mils Colorable 600V 1kV 2kV PV2 PV E327886 N/A ZKLA UL 4703/854/44 XLPE 45/60 PVC 30 Black only x PV2 PV E327886 N/A ZKLA UL 4703/854/44 XLPE 60/70 PVC 30 Black only x x PV PV E327886 N/A ZKLA UL 4703/854/44 XLPE 60/75 N/A N/A Y x PV PV E327886 N/A ZKLA UL 4703/854/44 XLPE 75/85 N/A N/A Y x x SE USE/USE-2 E338780 N/A TYLZ UL 854/44 XLPE 30/45 N/A N/A Y x SE USE/USE-2 E338780 N/A TYLZ UL 854/44 XLPE 45/60 N/A N/A Y x SE USE/USE-2 E338780 N/A TYLZ UL 854/44 XLPE 60/70 N/A N/A Y x TH Thermoset E349360 XHH ZKST UL 854/44 XLPE 30/45 N/A N/A Y x TH Thermoset E349360 XHHW ZKST UL 854/44 XLPE 30/45 N/A N/A Y x TH Thermoset E349360 XHHW-2 ZKST UL 854/44 XLPE 30/45 N/A N/A Y x TH Thermoset E349360 RHW ZKST UL 854/44 XLPE 45/60 N/A N/A Y x TH RHW ZKST UL 854/44 XLPE 60/70 N/A N/A Y x TH Thermoset E349360 RHW-2 ZKST UL 854/44 XLPE 45/60 N/A N/A Y x TH RHW-2 ZKST UL 854/44 XLPE 60/70 N/A N/A Y x TH Thermoset E349360 RHH ZKST UL 854/44 XLPE 45/60 N/A N/A Y x TH RHH ZKST UL 854/44 XLPE 60/70 N/A N/A Y x TH Thermoset E349360 R90 ZKST cul 854/44 XLPE 30/45 N/A N/A Y x TH R90 ZKST cul 854/44 XLPE 45/60 N/A N/A Y x TH R90 ZKST cul 854/44 XLPE 60/70 N/A N/A Y x TH Thermoset E349360 RW75 ZKST cul 854/44 XLPE 30/45 N/A N/A Y x TH RW75 ZKST cul 854/44 XLPE 45/60 N/A N/A Y x TH RW75 ZKST cul 854/44 XLPE 60/70 N/A N/A Y x TH Thermoset E349360 RW90 ZKST cul 854/44 XLPE 30/45 N/A N/A Y x TH RW90 ZKST cul 854/44 XLPE 45/60 N/A N/A Y x TH RW90 ZKST cul 854/44 XLPE 60/70 N/A N/A Y x RWU Thermoset E349360 RWU75 ZKST cul 854/44 XLPE 60/80 N/A N/A Y x RWU Thermoset E349360 RWU90 ZKST cul 854/44 XLPE 60/80 N/A N/A Y x * denotes / which is a change in insulation thickness for larger AWG wire PV, 18-6AWG, Others 14-6AWG White = Standard dual pass PV with XLPE insulation and PVC Jacket-scheduled for phase out Red = Wire that will satisfy all red, orange, yellow, green and blue rows. Could be Marked UL, cul, or culus Orange = Wire that will satisfy all orange, yellow, green and blue rows. Could be Marked UL, cul, or culus Yellow = Wire that will satisfy all yellow, green and blue rows. Could be Marked UL, cul, or culus Blue = Wire that willl satisfy all blue and green rows. Could be Marked UL, cul, or culus Green = Wire that will satisfy all green rows. Could be Marked UL, cul, or culus How to order 1 2 3 4 5 6 7 SE S B 10 7 600 A Product line Cable Type Jacket Color AWG Stranding Voltage Composition SE USE/USE-2 600V S Standard W White 18 18AWG (PV & PV2 Only 7 600 600 A Aluminum TH USE/USE-2 1000V AND 2000V B Black 16 16AWG (PV & PV2 Only) 19 1kV 1000 B Bare CU RWU RWU(75) / RWU(90) R RED 14 14AWG 2kv 2000 T Tinned CU PV Solar Single Jacket G Green 12 12AWG PV2 Solar Dual Jacket Y Yellow 10 10AWG BL Blue 8 8AWG 6 6AWG Note: Product lines PV and PV2 are available in 18 to 6AWG, all other product lines are available in 14 to 6 AWG

AMPHENOL CORPORATION Amphenol Industrial Phone: 607-563-5011 40-60 Delaware Avenue Sidney, NY 13838-1395 www.amphenol-industrial.com IB-2 Notice: Specifications are subject to change without notice. Contact your nearest Amphenol Corporation Sales Office for the latest specifications. All statements, information and data given herein are believed to be accurate and reliable but are presented without guarantee, warranty, or responsibility of any kind expressed or implied. Statements or suggestions concerning possible use of our products are made without representation or warranty that any such use is free of patent infringement and are not recommendations to infringe any patent. The user should not assume that all safety measures are indicated or that other measures may not be required. Specifications are typical and may not apply to all connectors. HKA -2012

Amphenol s Solar Market Solutions Amphenol Industrial Global Operations is a leader in the design and manufacturing of products and solutions for all segments of the solar electric system industry. At AIGO, we understand the need for efficient (low loss) power transfer systems that are highly reliable and competitive, cost effective solutions. We provide panel manufacturers, installers, and OEM s with wire, connectivity, and grounding products for both thin film and crystalline silicon technologies. All AIGO products meet the National Electric Code specifications. Our Single Conductor PV, USE-2, and Thermoset cables are designed for any solar application PowerLink cables are manufactured to handle all kinds of harsh environments XLPE (cross linked polyethylene) insulation provides a tough abrasion-resistant jacket that resists sunlight, ozone, and UV radiation