DEPARTMENT OF CHEMICAL ENGINEERING INDIAN INSTITUTE OF TECHNOLOGY MADRAS CHENNAI , INDIA

Similar documents
NATIONAL CENTER FOR COMBUSTION RESEARCH AND DEVELOPMENT (NCCRD) INDIAN INSTITUTE OF TECHNOLOGY MADRAS CHENNAI , INDIA

INVITATION FOR QUOTATION. TEQIP-III/2019/mmug/Shopping/51

BHEL/Trichy-14 CCDP SYSTEM DESCRIPTION FOR DOME VALVE:

Chlorinator MODEL MK-I

Chlorinator. MODEL C-731 (Floor Mounted)

Tank Blanketing Regulators

Inert Air (N2) Systems Manual

Tank Blanketing Regulators

CAPITAL CONTROLS SERIES NXT3000

Description Advanced Features Typical Applications

NIT LIMITED NO. NC-105-P-SCS-NOCB CYLINDERS & REGULATORS

Indian Institute of Technology Kanpur Samtel Centre for Display Technologies

Schedule of Requirements THERMODYNAMICS LABORATORY- CHEMICAL ENGINEERING DEPARTMENT

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

HUMIDITY CONTROLLED PROBE STATION (Total Budget: 0.55 crores INR) S.No. Item Unit Qty Make

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

Stirred Reactors and Pressure Vessels

ENERGY BLADE 3K4. Energy Blade Installation Instructions

Air Operated Hydraulic Pumping Systems to 50,000 psi

OVERVIEW METCELL SPECIFICATIONS. Lab scale nanofiltration equipment The METcell Range

Installation and commissioning instructions 255 series and 256 series

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Expert Hydrostatic Level Transmitters

Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Pneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar)

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

Operational Settings:

Smart Water Application Technologies (SWAT) TM

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

3/8" Dr. Air Butterfly Impact Wrench

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Technical Specifications of Hydrogen Isotope Handling and Recovery System

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

FOAM TANK (1/2) DATA SHEET

CSIR-NATIONAL GEOPHYSICAL RESEARCH INSTITUTE (COUNCIL OF SCIENTIFIC & INDUSTRIAL RESEARCH) Uppal Road, Hyderabad (Telangana.

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

KFI Approved. High Pressure CO2 System Technical Datasheets

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

HIGH-PRESSURE HIGH-FLOW PUMP UNITS TYPE BMS

DBML-60/80 Squeeze Tool

Breather Control V1.4. Installation Manual

Specifications of Cryogenic vacuum jacketed valves

Neotecha Tank Sampling Sapro

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

TECHNICAL ACCESSORIES

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

INSTRUCTION MANUAL. Thanks for purchasing our airbrush compressor and please read this

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

Air Amplifiers & SYSTEMS

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

High Pressure Breathing Air Compressors

Models: C62/63/64-A/D

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Filter Integrity Testers for the Pharmaceutical Industry

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

Chemical Injection Technologies Installation/Service Bulletin

LGSS Liquefied Gas & VSS Vapor (Gas) LGSS VSS LGSS. Features and Benefits

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Installation restrictions for length of sections should also be noted.

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

v. Size shall be specified on drawings.

Instructions for SILEX 1C Mixed bed cartridge filter

NIT LIMITED NO. RD-NC-40-SPS-PH

OPERATING INSTRUCTIONS

Siphon vessel / Priming aid

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

DETERMINING OPTIMUM RESIDUAL ASPHALT CONTENT (RAC) FOR POLYMER-MODIFIED SLURRY SEAL (MICROSURFACING) MIXTURES

Pressure calibration equipment

OPERATION MANUAL NTF-15

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Installation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels

from Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010

IMPORTANT SAFETY INSTRUCTIONS

Horizontal Bladder Tanks

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

OPTIPOW 105 OPTIPOW 105 ; MAIN PARTS. Our Ref: PSE, Bernt Andersson

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

INSTALLATION INSTRUCTIONS

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

Vertical Bladder Tanks

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

For Department of CSSD

Neotecha Tank Sampling Sapro

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

VACCUPERM Vacuum chlorine gas dosing systems

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Float Operated Level Controllers

Transcription:

DEPARTMENT OF CHEMICAL ENGINEERING INDIAN INSTITUTE OF TECHNOLOGY MADRAS CHENNAI 600036, INDIA Ref. No. CHE/17-18/CHE/006/GAIM/RAJN Date: 25 APRIL, 2018 Due date: 9 MAY, 2018 Item: High Pressure Gas Hydrate Exploitation Setup with Injection and Production Wells 1. Two bid quotations (technical and commercial separately) are invited in duplicate for the item shown overleaf (in Annexure I). The quotations duly sealed and superscribed on the envelope with reference no. and due date, should be addressed to the undersigned so as to reach on or before the due date mentioned above 2. Quotations are only invited from firms who have at least five years of experience in fabricating customized lab and bench scale equipment for gas hydrate studies and applications. 3. The quotations should be valid for sixty days from the due date and the period of delivery required should also be clearly indicated. 4. The total cost of the equipment in terms of CIP Chennai should be clearly mentioned. 5. Terms of warranty and guarantee should be explicitly mentioned. 6. Packing and delivery charges, customs and clearance duty should be clearly stated. 7. Goods shall not be supplied without an official supply order. 8. Local firms: Quotations should be for free delivery to this institute. If quotations are for exgodown, delivery charges should be indicated separately. 9. Firms outside Chennai: Quotations should be for F.O.R. Chennai. If quotations are F.O.R. consignor station, freight charges by passenger train / lorry transport must be indicated. If quotation is for ex-godown, packing, forwarding and freight charges must be indicated. 10. The rate of sales / general taxes and the percentage of such other taxes legally leviable and intended to be claimed should be distinctly shown along with the price quoted. Where this is not done, no claim for sales / general taxes will be admitted at any stage and on any ground whatsoever. The taxes leviable should take into consideration that we are entitled to have Concessional GST applicable to non-government educational institutions run with no profit

motive for which a concession sales tax certificate will be issued at the time of final settlement of the bill. 10. Payment: Specify the mode of payment and if advanced payment has to be made. Every attempt will be made to make payment within 30 days from the date of receipt of bill / acceptance of goods, whichever is later. 11. IIT Madras is exempt from payment of excise duty and is eligible for concessional rate of customs duty. Necessary certificate will be issued on demand. 12. IIT Madras has the right to accept the whole or any part of the tender or portion of the quantity offered or reject it in full without assigning any reason. 13. In case of any queries/clarifications, please contact Dr. Rajnish Kumar, Chemical Engineering, IIT Madras, Chennai, E-mail: rajnish@iitm.ac.in. 14. The sealed quotation may be sent to Dr. Rajnish Kumar Dept. of Chemical Engineering, IIT Madras Chennai 600036 (P) +91-44-22574180 rajnish@iitm.ac.in

DEPARTMENT OF CHEMICAL ENGINEERING INDIAN INSTITUTE OF TECHNOLOGY MADRAS CHENNAI 600036, INDIA ANNEXURE I Technical Specifications for High Pressure Gas Hydrate Exploitation Setup with Injection and Production Wells Scope/Application: A highly customized pressure and temperature controlled SS-316 setup is required for gas hydrate studies (please refer the process flow diagram and other details attached with this document). Setup would be operated at sub-zero temperature and up to 200 bar pressure to study synthesis and dissociation of methane hydrate. The temperature and pressure conditions would simulate marine environment. The setup includes high pressure injection well and low pressure production wells to study formation and dissociation kinetics of hydrate growth / decomposition with complete control and real time data acquisition on computer hard drive / flash drive. The study involves exploitation of natural gas hydrate in bench / pilot scale laboratory setup. Technical Specifications of the Setup: a) Volume & M.O.C Approximately 10L net filling capacity with head made from SS-316 Bar stock & body fabricated from SS 316 plates & all wetted parts of SS 316. With fixed head design & pneumatic raising /, lowering and tilting arrangement of the vessel or pulley based raising and lowering arrangement of the vessel. (Note: The internal diameter of the reactor shall be ~240 mm and the length of the reactor shall be ~200 mm) b) Design Pressure 200 Bar c) Maximum working Temp. -30 Deg. C to 100 Deg. C d) Nozzles & Fittings i) External Fittings: Pressure gauge, SS316 Pressure Transmitter, vent valve connected to vacuum pump, safety rupture disc, gas inlet- valve, Pressure relief valve of MOC SS- 316, Water inlet valve, 1 nos. spare nozzle with needle valve, vacuum gauge. Note: All valves end connection shall be ¼ NPT (M). ii) Internal Fittings: 8 nos. Thermowells from bottom at different levels (with RTD PT-100 temp. sensor), 1no. ½ Injection well & 1no. ½ Vertical production well from bottom, 1 no. ½ horizontal production well from side. e) Body & Head Sealing PTFE Gasket / chemical resistant gasket with split clamp type quick opening system with clamp bolts or C-clamp type opening system. f) Heating & Cooling Through SS 304 jacket with insulation and cladding & M24(M) threads at inlet & outlet. g) High pressure metering For pumping water at a Flowrate of 100ml/min piston pump with a max. discharge pressure of pump with VFD 100 bar, into the reactor through the water inlet valve. Pump should also be capable of working at a back pressure of 100 bar. h) Vacuum pump Oil free pump for 10mbar vacuum inside the reactor. i) Detachable Wells The wells shall be ½ size tubes with perforations to allow flow of solvent. Size of pores: 2mm dia.

Distance between pores : 1 cm Length of wells: 16 cm for Vertical Wells & 20 cm for horizontal well. MOC: SS 316 (Note: All 3 wells shall be covered with SS mesh of 125 micron & can be detached from the system for cleaning purpose.) j) CO2 solvent charging system It consists of a CO2 gas cylinder mounted on a weighing scale of 0-50kg capacity and accuracy of 1gm. The liquid from the cylinder along with some additives (which shall be added in the line using a small hopper) shall pass through a heat exchanger & SS static mixer of ½ diameter, 100-150mm long and enter the reactor through the injection well. k) Moisture Trap Connected to the outlet of Vertical production well and horizontal production well with inline filter. It consists of 1Ltr SS316 vessel (designed for ~150 bar with L/D of ~10), Pressure gauge, gas / water inlet valve & vent valve. Mounted on a weighing scale of 0-25kg capacity and accuracy of 1 gm. Moisture trap should have some kind of a molecular sieve/packing material to trap the moisture and separate the gas. l) Back Pressure Regulator Pneumatically / electrically operated manual / digital back pressure regulator for 200bar of MOC SS-316 to maintain constant pressure inside the autoclave by venting excess pressure with suitable N2 / O2 gas cylinder, manual regulator and hose pipe m) Gas Reservoir/Solvent Reservoir ~1.5 Ltr SS316 vessel designed for ~150 bar with inlet valve, outlet valve, pressure relief valve, pressure transmitter & thermocouple. n) Control Panel SS control Panel with 9 nos. temperature indicator, 5 nos. digital pressure indicator with high pressure alarm. o) Data Logger 24 channel data logger capable of storing at least up to 50,00,000 records and records automatically readable in Microsoft Excel. p) Piping & Valves All interconnecting piping & valves. q) Mounting Mounted on Aluminum / SS 304 skid with polishing of complete reactor. r) Torque wrench For uniform tightening, easy operation & ensuring leak tightness. The drawings for this system have been attached below:

*ER-1 and ER-2 are in customer scope. Dr. Rajnish Kumar Dept. of Chemical Engineering, IIT Madras Chennai 600036 Phone: +91-44-22574180 Email: rajnish@iitm.ac.in