T-937 lead-free reflow oven user manual

Similar documents
Reflow Oven HHL3000 INSTRUCTION MANUAL POHUA - jedyny autoryzowany przedstawiciel w Polsce

Diver-Office. Getting Started Guide. 2007, Schlumberger Water Services

AIR FLOW ANEMOMETER INSTRUCTION MANUAL

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com

Oxygen Meter User Manual

CONSUMER MODEL INSTALLATION GUIDE

ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11

ALGE DIVE! ALGE. ALGE-TIMING GmbH & Co

DDR Dive Data Recorder Manual - Rel /12

Thermal Profiling the Reflow Process

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Instruction Manual. BZ7002 Calibration Software BE

XC2 Client/Server Installation & Configuration

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

SHIMADZU LC-10/20 PUMP

5890II GC Standard Operating Procedure 9/2/2005

Mapping a Magnetic Field. Evaluation copy. Figure 1: Detecting the magnetic field around a bar magnet

Respiration. Exercise 1A: Breathing in Resting Volunteers Aim: To measure breathing parameters in a resting individual.

Evaluation copy. Vapor Pressure of Liquids. computer OBJECTIVES MATERIALS

uemis CONNECT: Synchronisation of the SDA with myuemis

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

iworx Sample Lab Experiment HE-4: Respiratory Exchange Ratio (RER)

Combination Analysis Tutorial

TR Electronic Pressure Regulator. User s Manual

Tournament Manager: Running a VEX IQ Event - Beginner

Swing Labs Training Guide

Trion PECVD SOP IMPORTANT: NO PLASTIC, TAPE, RESISTS, OR THERMAL PASTE ARE ALLOWED IN THE CHAMBER

TOMI PRO MODEL PERSONAL MODEL

In addition to reading this assignment, also read Appendices A and B.

HyperSecureLink V6.0x User Guide

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

TESLAGON. ShotHelper Manual. How to install and use the Program. Version /30/2014

Gas Analyzer for TC Sensors (CO2, H2, N2) Series 62101, 64101, Operating Manual

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

iworx Sample Lab Experiment HE-5: Resting Metabolic Rate (RMR)

Operating Manual. BACVis. Manual BACVis. for. Sensors and MilliGascounter. Rev

Biology 347 General Physiology Lab Basic Pulmonary Functions: Respirometry and Factors that Effect Respiration

Experiment HS-2: Breathing and Gravity

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

Using the Lego NXT with Labview.

RM-80 respiration monitor

Stirring Water Bath. Instruction Manual

Wire Buddy Manual IOpath Software

OC508 Programmable mv Calibrator

AX5000 Operational Manual

DeeterFlow Automatic Liquid Dispenser

DIVE MEET SCORING INSTRUCTIONS. Day before meet

Setting up the Ingenico isc250 Pinpad via USB in Windows 8

Standard Operating Manual

Getting Started with the LabVIEW Toolkit for LEGO MINDSTORMS NXT

ACI_Release_Notes.txt VERSION Fixed Tank info for ELITE in Dive section 2. Fixed USB port initializing for old DC VERSION

Diver-Pocket Diver-Pocket Premium

iworx Sample Lab Experiment HE-5: Resting Metabolic Rate (RMR)

1001ICT Introduction To Programming Lecture Notes

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Contents. Page. Page. System Settings 10. Components 3. Basic Operation 4. Brightness. Volume (for use with sat nav software only) Play Golf

Chapter 6. Gas Analyser Interface. Hanatech Co., Ltd.

Setting Up the Ingenico isc250 Pinpad via USB

Pressure Calibrators. Series PC..., PM...

Restrictive and Obstructive Airway Diseases

Revision: 23 March 2008 (nk)

Quick Start Guide. A. Hardware installation B. Software installation C. Start the software for the first time D. Do your first measurement

Experiment HE-9: Resting, Active, and Exercising Metabolic Rates

Experiment HE-9: Resting, Active, and Exercising Metabolic Rates

Figure SM1: Front panel of the multipatcher software graphic user interface (GUI) at the beginning of multipatcher operation.

Vapor Pressure of Liquids

1. Software Installation Please make sure to install software before connecting the PC Interface Unit to your Computer.

Panther 5 Acute Care Ventilator

Microfluidic Demonstration

Manual of SF6 Comprehensive Tester

Feasibility of Using the Wiimote Multi-point Interactive Whiteboard in School

Tennis...32 Stay above...34 Decimal...36 Bundesliga simulator...38 Shooter management...41 Installation...43 Registration...45 Where do I get the

SmartMan Code User Manual Section 5.0 Results

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

Boyle s Law: Pressure-Volume Relationship in Gases

MP15 Jockey Pump Controller

Temperature Controller CC24-7 ULTRA USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

We Warm Animals. User Manual For. Darvall Heated Smooth-Wall Circuits. Darvall Heated ZDS Qubes

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

Pneumatic high-pressure controller Model CPC7000

Vapor Pressure of Liquids

Evaluation copy. Wind Chill. computer OBJECTIVES MATERIALS

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

HumiSys HF High Flow RH Generator

Pneumatic high-pressure controller Model CPC7000

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

Chromat Calibration Updated October 27th, 2017

For The First Time Quad Doppler Radar and Dual Photometric Cameras in One Launch Monitor.» User Manual

Respiratory Response to Physiologic Challenges. Evaluation copy

Quadruple mass spectrometers (transducer type)

AKTA pure 25 New Owner s Intro

Tutorial 2 Time-Dependent Consolidation. Staging Groundwater Time-dependent consolidation Point query Line query Graph Query

DRS25 PROCESS DEVELOPMENT GUIDE.

JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012

VROC (Viscometer/ Rheometer-on-a-Chip) User s Manual 1

Rimage Everest 600 Thermal Retransfer Printer

Transcription:

+. T-97 lead-free reflow oven user manual Taian Puhui Electric Technology Co., Ltd Http://www.tech68.cn

User Manual. Parameters.... Configuration.... Main parts.... Installation... 5. Software Interface... 6. Manual Instruction... 6 7. Attention... 9 8. Warranty... 9 Declaration... 9 Http://www.tech68.cn / 9

. Parameters. Configuration T-97 lead-free reflow oven user manual Soldering area 06mmXmm Dimension 0mmX7mmX80mm N. Weight 5.5kg Voltage/Frequency AC0~0V/50~60Hz Power rating 00W Cycle time ~6 min Temp rage Room temp~50 Name Q ty T-97 lead-free reflow oven Power line fuse CD COM communication line. Main parts Mainbody Operation Panel Operation panel Drawer Switch Plug base Indicator light Display Key Http://www.tech68.cn / 9

Others Exhaust COM. Installation i. Please put this reflow oven on the flat tabletop. ii. Please put this reflow oven in safe environment, not flammable or combustible. iii. Please leave 0mm around the machine, for heat dissipation. iv. The machine must be connected with Earth wire. 5. Software Interface Main Interface 9 8 7 6 5 :Menu bar :Shortcut bar :client drawing area :display setting area 5:operation tip area 6:T-t data wave 7:control point 8:control point line 9:toolbar Http://www.tech68.cn / 9

The client drawing area 7 5 6 :temp axis :cursor :solder paste character wave :coordinate display 5:time axis 6:effected wave7: wave graph Shortcut bar 5 6 7 :check machine memory wave :run the machine memory wave :solder paste brand :solder paste model 5:re-set viewport 6:set cycle time 7:current oven temp Display setting area 5 6 :control points moving direction :partially/completely move the control point :change to set control point cursor :save pic in client drawing area 5:show topics 6:wave line width 7 7: paste 8 9 8:smooth wave 9:temp setting range Http://www.tech68.cn5 / 9

6. Manual Instruction i. Install RS driver Please see the CD- usb driverv. ii. Install the software Open the CD, find the T-97 回流焊控制系统.exe(T-97 Reflow Soldering Control System.exe), double-click, start to install. iii. Software Operation ) Viewport setting After open the software, you will see the viewport setting, in order to get good visual effect, please set the time parameter of viewport to reflow target time +0S, set the temp parameter to target peak temp+0, press confirm ) Operation with PC Please use the communication line to connect with computer. Open T-97 software, press menu bar-other function-system parameter, open the setting window. Select USB-SERIAL CH0 (COM**), press confirm and return to main interface, you will see like this in the shortcut bar, then press F on the reflow oven, T-97 reflow oven LCD displayer will show connected with PC, also you will see in the software, connect successfully. ) Make the wave Set the solder paste character click Display setting area -7 paste, the wave will display in the client drawing area. Click display setting area paste user, it will show the user-defined paste character, or the the paste character from the paste database. a) Use the paste database from software Select the paste model from the shortcut bar, the paste wave will display in client drawing area. b) User define paste data Click others user defined solder paste, it will show user defined paste window, fill in the paste parameters you use, click save. This wave will display in the client draw area. Set up the wave a) open the wave from machine memory Click menu open recipe, select the wave you want to use. Tips:this machine is with 8 waves inside, if these 8 waves can not match your solder paste, please adjust the wave in order to match with your solder paste, get good reflow effect. b) Set up wave Under place control points state, the mouse cursor will change to (click the right mouse button to switch place/check control points state ), then click in the client draw area, place the control point, set up new wave. Adjust the wave a) Under check control points state, double click the client draw area, it will show many control points on the wave, use the mouse to move the control points, the wave will change. b) also you can use to adjust the wave in different direction, it can change the wave fastly. Tips:the paste character wave show the theoretical wave, in fact, due to the influence of various factors such as heat conduction rate, so please adjust the wave according to the actually reflow effect, in order to get perfect soldering effect. Preview the wave Please click operation profile preview to check the wave which the user made if it meets Http://www.tech68.cn6 / 9

request, if the temps are over the T Limit (in the display setting area, No.9), this software will set these temps to 5 automatically. 5 Set the wave heating time Please set the heating time in the shortcut bar 6 Save the wave Click menu - save recipe, fill in the wave name, press save. 7 Manager the wave Click database management recipe management, will display the wave management window. ) Send the wave to T-97 reflow oven T-97reflow oven has 8 file areas for saving the waves, if not connect with PC, T-97 reflow oven can perform the wave independently. After making the wave in the computer side, click operation send to device, select the profile No. to send. 5) View the waves in machine Click the view, select the profile No, this wave will display in the client drawing area, then you can adjust the wave here, and save it. 6) Run the wave in machine Click the run in the shortcut bar, select the profile No, it will show wave running window, start soldering. iv. Independent Operation Panel Displayer heating Fan cooling F F F return Interface Independent operation interface Chinese/English Main interface Connection interface Http://www.tech68.cn7 / 9

Wave running interface Independent operation interface Select wave interface Thermostatic timer interface The main interface performing the wave interface running time set temp current temp Selecting wave interface wave number operation tips(f/select next wave ; F/select last wave; F:switch last/next 8 mins wave) Thermostatic timer interface 5 Set temp set time(--:-- is untimed model) operation tips(f/ up,f/ down,f/switch set temp or set time current temp 5 current running time Http://www.tech68.cn8 / 9

Operation )Enter the software interface Press F, will come to the independent operation interface )Select the wave Under the independent operation interface, press F to select wave, press F and F to select the wave you need, then press return key to independent operation interface. )Run the wave Under the independent operation interface, press F, it will run the wave you selected. )Thermostatic timer function Under the independent operation interface, press F, start the thermostatic timer function. Thermostatic timer function means the machine can keep thermostatic temp if you set time, once time over, the machine stop heating. Press F change set temp / set time, press F/F to adjust the numerical value, the time is--:-- is untimed model, means the machine is keeping thermostatic heating, not stop automatically. 5)Change language Under the main interface, press F to change the language. 7. Attention i. If not use this machine for long time, please unplug the power line plug. ii. The machine should be connected to the exhaust passage within the outdoor ventilation or exhaust recovery, prevent solder paste volatiles poisoning. iii. This machine is with strict protective insulation materials, please don t open the machine casually. 8. Warranty The warranty for mainbody is one year, for parts is three months, provide lifetime technical guide. Declaration If there is inconsistency between this user manual and the actual product, the actual product shall govern. Http://www.tech68.cn9 / 9