Sanitary RTD Temperature sensor TH17. Measuring System Sanitary RTD assembly with connection head TH17 for food and dairy applications.

Similar documents
RTD Temperature sensor TH11

Operating Instructions

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

MODELS (2 foot Version) (4 foot Version)

Operating Instructions

INSTRUCTION MANUAL Pressure Relief Device LPT

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

L3 Pressure and Level transmitter

DTG - LCD Digital Temperature Gauge USER MANUAL

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Electro-Pneumatic Converter YT-940 SERIES

Pressure Measurement Single-range transmitters for general applications

Norrsken Family Booklet

Pressure Independent Control Series

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

Position switches FP series

Arran LED Floodlight Luminaire

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Technical Information Conducal CLY421

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

NEW TYPE M PRESSURE RELIEF DEVICE

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Automatic extractor outlet

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

VG5 Supplementary instructions

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

Further technical information is available on

RTD temperature probes

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

High-performance submersible pressure transmitter For level measurement Model LH-10

GEMS SENSORS & CONTROLS

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Part I - Installation

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

SDX Submersible Depth Transmitter User Manual

CP10 Sensor Installation and Maintenance Instructions

G96 Series BASOTROL Dual Operator Valve

CFSW. Hinges with built-in safety multiple switch

Electronic gas volume corrector model DGVC-04

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15

MODEL 154XST INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL 154XST STROBE LIGHT FOR USE IN HARSH ENVIRONMENTS/ HAZARDOUS LOCATIONS

JUMO dtrans p30 Pressure Transmitter

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

2-1- Shipping Receiving Lifting Location on Site Installation Stages 6

Socket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD

INSTALLATION MANUAL JAPANESE ENGLISH GERMAN FRENCH ITALIAN SPANISH. Before installation. Installation INSTALLATION MANUAL: B700

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

120 Series Explosion-Proof Pressure and Differential Pressure Switches

IP65 Air Differential Pressure Switch

How to specify a product. Process Sensors and Mechanical Instruments

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

LED 14W POLO BULKHEAD WITH MICROWAVE SENSOR

! Warning, refer to accompanying documents.

DK48 - DK800. Quick Start. Variable area flowmeter

Pressure Measurement Single-range transmitters for general applications

PRO-50 Instrument Supply Regulator

Instrument Operating Manual

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

INSTALLATION PROCEDURE FOR OPGW FIBER OPTIC CABLES

A17W23_MASE_MUS_EN MANUAL

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

XMPA12B2142 pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type

200 PSI COMPRESSORS - MODEL NUMBERS

SEMEM3-65 Servicing anaesthetic and ventilation equipment

CCSSL35 Carry out the wiring and testing of electrical circuits and equipment

Installation and Operation Manual

IMPORTANT SAFETY INSTRUCTIONS

100C Air Compressor Kit

SPECIFICATIONS ATTENTION

sitrans p Operating Instructions (de/en) Edition 03/2004

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Operating Instructions Rope Pull Switches RPS...

Monitoring device NTS 30

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Pressure Dump Valve Service Kit for Series 2300 Units

T EK-SUB 4800C 19 mm Submersible Level Transmitter

Pressure Transmitter P41

INSTALLATION & OPERATION MANUAL. Dual Duct VAV Terminals. Redefine your comfort zone.

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

BGA158 Series CE Approved Class A Shutoff Gas Valve

Operation Manual Air Saver Unit ASV5000 Series

SDX Submersible Depth Transmitter User Manual

Zelio Relays RSL Slim Interface Plug-In Relays

OC Panel High Limit Aquastat Kit, Manual Reset p/n

USER MANUAL. JET TST and JET TST S.

Sunbrite LTC Large Underwater Pool Lights

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

Two-stage valve type NE

Electromechanical pressure switches

COOPER POWER SERIES. Under-oil arrester disconnector installation/operation instructions. OEM Equipment MN800010EN

Transcription:

Sanitary RTD Temperature sensor TH17 Compact Instructions Measuring System Sanitary RTD assembly with connection head TH17 for food and dairy applications. The single element RTD is specifi cally designed for use in process temperature range -58 F to 392 F (-50 to 200 C). Meets 3-A sanitary standards. 574-02 KA180R/24/ae/06.05 51008425

Important Notice # Warning" Electrical shock could cause death or serious injury. If the sensor is installed in a high voltage environment and a fault or installation error occurs, high voltage may be present on the connection terminals or the probe itself. Safe and secure operation of the temperature sensor can only be guaranteed if the operating instructions of the used transmitters and all included safety notes are read, understood and followed. For Endress+Hauser temperature transmitters see enclosed CD ROM. Correct use The manufacturer cannot be held responsible for damage caused by misuse of the unit. The installation conditions and connection values indicated in the operating instructions must be followed" Installation Guidelines and Safety instructions 1. Install the unit according to the relevant NEC Code and local sanitary regulations. 2. Avoid any spark due to impact, friction and installation. Anti-sparking wrenches should be utilized. 3. The temperature sensor should be connected to the power supply or other external circuit using the appropriate cable glands and wire entries. 4. For ambient temperature higher than 158 F, suitable cables, conduit and conductors must be used. Only use approved wire entries. 5. When utilized in dust atmospheres, the connection between the housing,! ttings and thermowell should provide a minimum degree of Ingress Protection. Liquid/gas sealants should be used. Local regulations need to be respected. 6. Installation procedures relating to integrity of sanitary processes should be followed to prevent any contamination. # Warning" Do not disconnect equipment unless power has been switched off or the area is not hazardous.

The accessories for pipe connections and the appropriate gaskets and sealing rings are not supplied with the sensors. These are the customer s responsibility. Depending on temperature and pressure operating conditions, the gaskets, the sealing and clamping rings and the applicable torques must be selected by the user. For further information regarding connections, please refer to the corresponding Standards. Installation and operation The unit is constructed using the most up to date production equipment and complies with the safety requirements of the local guidelines. However, if it is installed incorrectly or misused, certain application dangers can occur. Installation, wiring and maintenance of the unit must only be completed by trained, skilled personnel who are authorized to do so by the plant operator. The plant operator must make sure that the measurement system has been correctly wired to the connection schematics. Procedures indicated in these instructions must be followed. Returns Please follow the Return Authorization Policy which is attached with this manual. Safety pictograms and symbols! Note" Notes draw attention to activities or procedures that can have a direct in# uence on operation or trigger an unforeseen device reaction if they are not carried out properly. J Caution" Cautions draw attention to activities or procedures that can lead to persons being injured or to incorrect device operation if they are not carried out properly. # Warning" Warnings draw attention to activities or procedures that can lead to persons being seriously injured, to safety risks or to the destruction of the device if they are not carried out properly. Though the information provided herein is believed to be accurate, be advised that the information contained herein is NOT a guarantee of satisfactory results. Speci!cally, this information is neither a warranty nor guarantee, expressed or implied, regarding performance; merchantability,!tness, or other matter with respect to the products; and recommendation for the use of the product/process information in con"ict with any patent. Please note that Endress+Hauser reserves the right to change and/or improve the product design and speci!cations without notice.

Installation Installation locations a: At angle sections, against the direction of # ow b: Perpendicular to the direction of # ow For installation proceed as follows: 1. Make sure that the hygienic process! tting and the clamp assembly match the maximum speci! ed process pressure. 2. Install and tighten the RTD sensor before applying process pressure.! Note" Minimum immersion is 1¼ as per ASTM E644.

Electrical connection-wiring diagrams Head transmitter mounted Terminal block mounted! Note! The blocks and transmitters are shown as they will sit inside the heads in reference to the conduit opening. ALWAYS terminate leads to the outside screw!

Dimensions Immersion length L All dimensions in inches 2, 4, 6 speci! ed length 2 to 30 in ½ increments

Technical data Weight From 1 to 5.5 lbs Material Wetted parts 316L SS Shock and vibration resistance 4g/2 to 150 Hz as per IEC 60 068-2-6 Ambient temperature limits Housing without head-mounted transmitter Aluminium pressure die-cast -40 to 302 F (-40 to 150 C) housing Plastic housing -40 to 185 F (-40 to 85 C) Housing with head-mounted transmitter All types of housing -40 to 185 F (-40 to 85 C) Performance Characteristics Response time 63% response time per ASTM E644 Construction Ø ¼ Ø 3/8 red. 3/16 4 s 3 s Maximum measured error Class max. Tolerances ( C) A ± (0.15 + 0.002 t *) * t = absolute value C. For measurement errors in F, calculate using equation above in C, then multiply the outcome by 1.8. Insulation resistance Insulation resistance between terminals and probe sheath, test voltage 250 V. 100 MW at 77 F (25 C) 10 MW at 572 F (300 C)

Supplementary documentation TMT180 Pt temperature head transmitter TMT181 PCP temperature head transmitter TMT182 HART temperature head transmitter TMT162 HART temperature fi eld transmitter BA163r24ae fi nd on CD-ROM BA100r24ae fi nd on CD-ROM BA105r24ae fi nd on CD-ROM BA132r24ae fi nd on CD-ROM All Temperature Operating Instructions are available on CD ROM, fi nd enclosed or order by order number: SONDTT AG. r (Mexico) S.A. de C.V. Calle de Gustavo Baz No. 43 Fraccionamiento Bosques de Echegaray CP 53310 Naucalpan de Juárez éxico +52 55 5371 1110 +52 55 5371 1128 80 6 5 425