Effect of clothing ventilation on thermal insulation and vapor resistance

Similar documents
Required clothing ventilation for different body regions in relation to local sweat rates

KATEDRA MATERIÁLOVÉHO INŽENÝRSTVÍ A CHEMIE. 123MEAN water vapor transport

Comparison of two tracer gas dilution methods for the determination of clothing ventilation and of vapour resistance

Frostbite in Ski Boots for Marines

Bubble Elimination Device in Hydraulic Systems

ANALYSIS OF HEAT TRANSFER THROUGH EXTERNAL FINS USING CFD TOOL

WHAT WILL YOU WEAR THIS SEASON?

Effect of airflow direction on human perception of draught

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

H. Laamanen(l), H. Meinander(1) and Ingvar Holmer(2)

Strategies to Reduce the Heat Stress of Wearing New Biological and Chemical Protective Combat Uniforms in MOPP 1

The Air-Sea Interaction. Masanori Konda Kyoto University

Understanding Swimming Pool Ventilation. Presented by Tom Sands Mobile: CPD003/v03tcs2016

Available online at ScienceDirect. Procedia Engineering 112 (2015 )

Frostbite in Ski Boots for Marines

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

- Introduction: a) Metallized Paper & Film :The market Outlook The following diagram shows the estimated usage of the main metallized materials

Change of Footwear Insulation at Various Sweating Rates

Cooling performance of Persian wind towers

Thermal Conditions in a Simulated Office Environment with Convective and Radiant Cooling Systems

Defense Technical Information Center Compilation Part Notice

Development of an artificial human for clothing research

Adiabatic Lapse Rates and Atmospheric Stability

ABSTRACT. are due to heat stress and cardiovascular strain. Protection requirements often contradict the

UNDERWEAR TECHNICAL T-SHIRT AVALANCHE / LINEA SKIN THERMAL LEGGINGS BLIZZARD / LINEA SKIN WATERPROOF JACKET WRC / LINEA IMPACT - 34

C I R E D 18 th International Conference on Electricity Distribution Turin, 6 th to 9 th June 2005

Controlling Cabin and Envelope Air Flows & Pressure Differentials

GEMINI 8-M Telescopes Project

Contact person: Aitor Coca address:

Effect of Moderate Altitude Exposure on Human Thermal Physiological Parameters and Heat Losses in different activities

The norm for High Visibility, EN 471, is one of the most widely known and used norms under the PPE directive.

Measurement of water vapour transport through a porous non-hygroscopic material in a temperature gradient

PROTEK HTING GARMENT FIREFIGHTING GARMENT FIREF EFIGHTING GARMENT FIREFIGHTING GARMENT FIREFIGHTING G. Firestar PROTEK

Thermal stress on firefighters in extreme heat exposure

Microclimate Control in the Foot-Stocking-Shoe System

Aalborg Universitet. Published in: EERB-BEPH Publication date: Document Version Publisher's PDF, also known as Version of record

TECHNICAL BULLETIN CRYOGENIC APPLICATION SERVICES. website:

COATINGS SPRAY GUIDE Acrylics (210, 211, 211HT, and 212)

Test of Firefighter s Turnout Gear in Hot and Humid Air Exposure

Purdue e-pubs. Purdue University. Stephan Lehr Technische Universitaet Dresden. Follow this and additional works at:

CLOSED LOOP SOLVENT EMISSIONS CONTROL. David C.H. Grant

Improving the Effectiveness of LEV A HSL perspective

Ventilation of Small Multispan Greenhouse in Relation to the Window Openings Calculated with CFD

Water on Earth. How do oceans relate to weather and the atmosphere? Solar Radiation and Convection Currents

A Study on the Effects of Wind on the Drift Loss of a Cooling Tower

ANNUAL GROUND TEMPERATURE MEASUREMENTS AT VARIOUS DEPTHS

Experimental Analysis of Inclined Narrow Plate-Fins Heat Sink under Natural Convection

Test Report No Insulguard Fire Resistance Enclosure. Insulguard Australia Bentleigh, Victoria

The Influence of Community Planning on Urban Thermal Environment

ENVIRONMENTAL PHYSICS

Application Performance and Numerical Analysis of Phase Change Diving Suit Ting Wei1,a, Zhilin Ye1,b, Baicun Zheng1,c

Macro-scale Mathematical Model for Hydration and TEWL in intact Stratum Corneum

HumiSys HF High Flow RH Generator

CFD Modeling of Thermal Manikin Heat Loss in a Comfort Evaluation Benchmark Test

The United States National Weather Service and

SENTINEL DRY SUIT LINER MSL600 MSL601

2. Practical way of realization of adiabatic process 2.1 Introduction

Users Guide for the Vertical Bunsen Burner Test for Cabin and Cargo Compartment Materials FAA Handbook Chapter 2

WP2 Fire test for toxicity of fire effluents

ADVANCES in NATURAL and APPLIED SCIENCES

AN IMPROVED CROSS VENTILATION MODEL IN WINDY REGIONS

HELLO ADVEN TURE. Starboard is all about Innovation and Quality.

Vertical Motion and Atmospheric Stability

Monitoring Gas Pressure in Vacuum Insulation Panels

Generating Calibration Gas Standards

Fire and Safety for Offshore drilling and production Ajey Walavalkar ANSYS Inc.

NUMERICAL INVESTIGATION OF THE FLOW BEHAVIOUR IN A MODERN TRAFFIC TUNNEL IN CASE OF FIRE INCIDENT

The future of multi-protective workwear is a unique combination of the highest safety, the best features and outstanding comfort.

Report No. 371/ This report consists of 6 pages

How To Use Getters and Getter Pumps

Selection, Care and Use of Chemical Protective Clothing. Jason Cole Director of R&D Kappler, Inc.

COATINGS SPRAY GUIDE Urethane 520

GACOFLEX TWO-COMPONENT LIQUID POLYURETHANE SPRAY GUIDE UA-60, U-64, UB-64, UA-7090, U-66

ALICE SPD cooling system

Chapter 4: Moisture and Atmospheric Stability The hydrologic cycle

Science 14: Chapter #5 - Heat & Heat Transfer. Baier's Science 14

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

Lab Orientation and the Surface to volume ratio in animals

Influence of Heat Transport by Sea Breezes on Inland Temperature in the Osaka Area

THERMAL COMFORT 3.1. INTRODUCTION.

Enter your parameter set number (1-27)

ZEFIRO series NITROGEN GENERATORS. The constant and completely autonomous supply of nitrogen flux DESIGN AND PRODUCTION OF LABORATORY GAS GENERATORS

UK Military Experience of Rotary Aircraft Fires and Equipment Provided to Mitigate this Risk

Defense Technical Information Center Compilation Part Notice

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events

AIRFLOW AROUND CONIC TENSILE MEMBRANE STRUCTURES

Variability in the tropical oceans - Monitoring and prediction of El Niño and La Niña -

Oil-Lubricated Compressors for Regenerative Cryocoolers Using an Elastic Membrane

Bio-Effluents Tracing in Ventilated Aircraft Cabins

COATINGS SPRAY GUIDE Fast Set Urethane 530

EFFECT OF INCORPORATED LUBRICATION ON THE TRIBOLOGICAL PROPERTIES OF POLYAMIDES

CONSIDERATION OF DENSITY VARIATIONS IN THE DESIGN OF A VENTILATION SYSTEM FOR ROAD TUNNELS

CHAPTER 3 RESULTS AND DISCUSSION

Manufacturer s Information

A07 Surfactant Induced Solubilization and Transfer Resistance in Gas-Water and Gas-Oil Systems

Physics Workbook WALCH PUBLISHING

Automatic Permeability Testing: The Challenges and Solutions Author: Alyce Hartvigsen, PBI-Dansensor A/S, Ringsted, Denmark

Trifecta Systems. Cryogenic Equipment for High Performance Gas Supply. Trifecta Product Catalog

Hydrostatic Head, Spray Rating and Shower Room

Evaluation of n-situ easurement ethods for ir ermeability of indows

Transcription:

Effect of clothing ventilation on thermal insulation and vapor resistance Xiaoqun Dai 1 and George Havenith 2 1 Soochow University, College of Textile and Clothing Engineering, Suzhou, 2156, P. R. China 2 Loughborough University, Human Thermal Environments Laboratory, Department of Human Sciences, Loughborough, LE11 3TU, UK Contact person: daixqsz@suda.edu.cn Abstract: In this study, ventilation of clothing microenvironment, thermal insulation and vapor resistance of two jackets made of different materials were measured locally at front, back, side and arm by using an articulated thermal manikin in a controlled climate chamber (29±1 C, 4±1%RH). The various conditions of microenvironment ventilation were created by making the manikin stand and walk, combined with three wind speeds of <.15,.4 and 2.m/s respectively. The analysis of the measurement results showed that clothing ventilation affected vapor resistance more than it did thermal insulation. The effects of ventilation also varied because of different ways of ventilation arising: penetration through the fabric was proven to be the most effective way in vapor diffusion although it does not seem helpful for heat diffusion. Keywords: clothing ventilation, heat transfer coefficient, vapor diffusion INTRODUCTION Clothing ventilation has been considered as a major pathway for heat and vapor transfer. Clothing materials, body posture, movement and wind are all influential on the ventilation of the microenvironment. Some study was carried to investigate the effect of material air permeability on ventilation (Ueda and Havenith 22). Many efforts were made to predicting convective heat transfer coefficient from change of posture, movement and wind, based on the data in a reference condition like standing with no wind. The evaporative heat transfer coefficient or permeability index was then obtained through Lewis relation. However, the Lewis relation was proven not to be correct for many windy conditions. Since heat diffusion is the combination of convection and radiation, Havenith et al. tried to separate the convective and radiative heat resistance, and proposed a new vapor permeability index based on the convective heat resistance (Havenith, Heus et al. 199), which was said to remain constant as the ventilation changed with movement and wind. However, as reported, the predicted values of i m were lower than actual values. Some recent study showed that Lewis relation may not hold in low wind situation(qian and Fan 26). Here, the difference of the effect of penetration through fabric on heat and vapor transfer may need to be taken into consideration. To investigate the effect of clothing ventilation (arising in different ways) on heat and vapor transfer, in this study, the local ventilation of the clothing microenvironment, thermal insulation and vapor resistance were measured by using an articulated thermal manikin. The various conditions of microenvironment ventilation were created by choosing garments of different materials, making the manikin stand and walk, combined with change of ambient air movement respectively. METHODS

Clothing ensembles Tops: To investigate the effect of materials on ventilation, two jackets of same style but made of different materials were used for the study. Jacket A was made of a waterproof and air impermeable material and jacket B was made of a normal textile material and thus air permeable. A long sleeve T-shirt and a jean were used as underwear and bottom for the two jackets. Measurement of clothing microenvironment ventilation Trace gas diffusion method was used to measure the ventilation on the body surface and argon was used as the trace gas (Lotens and Havenith 1988). A distribution tubing system was placed underneath the T-shirt to obtain as even as possible distribution of argon over the upper body surface, the sampling tubing system was placed similarly to the distribution one. To measure the local ventilation, additional single sampling tubes were also placed on the torso front, back, side and arm respectively. Measurement of clothing thermal insulation and vapor resistance The whole thermal insulation I t and vapor resistance R e, and the local ones at torso, front, back and arm for the two jackets were obtained by using an articulated thermal manikin, Newton (Measurement Technology Northwest) according to ISO 992:27. The manikin skin temperature was set as 35 C. The ambient temperature and relative humidity were set as 29±1ºC and 4±1%. Body movement and wind To investigate the influence of movement of the body and the surrounding air, the manikin was set into two states: standing still and walking at a speed of 45±1steps/min. A wind channel was used to create the forward wind and the wind speed was set as.4, and 2.m/s respectively. Together with the no wind (<.2m/s), there were three conditions of air movement. RESULTS In Fig. 2, where 1 through 6 denote the conditions of standing and walking without wind, in wind of.4 and 2.m/s respectively, the ventilation (V A and V B ), heat transfer coefficients(h ta, and h tb ), and the evaporative heat transfer coefficients(h ea and h eb ) for jackets A and B are shown. The increases of V, h t, and h e due to walking, wind and material difference are listed in Table 1. Microenvironment ventilation V The clothing ventilation usually arises in three ways: by permeation through fabric, by natural convection through openings, or by the pumping or bellow effects resulting from body movements forcing air around clothing in or out through openings such as collars, cuffs, bottoms and other vents. Fig. 2(a) and (b) show the whole ventilation and the local ventilation at the side, front torso, back and arm. Obviously, the ventilation at each local place is different, maybe

because of the different local air pressure fluctuations due to differences in thickness of the gap between the manikin surface and the clothing. When there is no wind, the manikin stands still, the ventilation is the lowest among all the tests for the two jackets because only permeation through the fabric and natural convection take place. Since the two jackets are of same style, there should be little difference in natural convection through openings. Therefore, the big difference of ventilation (up to 76%) between the two jackets must result from the different air permeability of the two materials. However, as ventilation increases with walking and wind, this difference decreases. 22 2 18 16 Whole Side Front 22 2 18 16 Whole Side Front 14 12 1 8 6 4 2 14 12 1 8 6 4 2 (a) V A (l/min) (b) V B (l/min) 6 6 5 4 5 4 3 3 2 2 1 1.55.5.45.4.35.3.25.2.15.1.5 (c) h ta (W/m 2 K) (d) h tb (W/m 2 K).55.5.45.4.35.3.25.2.15.1.5 (e) h ea (W/m 2 K) (f) h eb (W/m 2 K) Figure 2 Ventilation, heat and evaporative heat transfer coefficients of two jackets

Table 1 Increase of V, h t, and h e due to walking, wind and material difference(%) 1:Stand/no wind 2:Walk/no wind 3:Stand /.4m/s 4:Walk /.4m/s 5:Stand /2.m/s 6:Walk /2.m/s V A 172.7 53.2 232.4 827.8 878.3 h ta 39.3 15 53.3 1 119 h ea 9.1 8.9 12.2 236.1 27.8 V B 147.7 29.2 14.8 297.2 338.8 h tb 37.5 12.8 41.9 83.3 91.3 h eb 56.5 37.4 78.2 131.5 146.7 (V B -V A )/V A 75.7 73.3 71.2 66.5 43.4 45.9 (h tb -h ta )/ h ta 4.3 3 2.5-3.3-4.3-9.5 (h eb -h ea )/h ea 7.8 64.5 61.6 66.9 57.6 56.1 For the manikin walking without wind, the ventilation increased by 173% for A and 148% for B, confirming the strong effect of pumping. For the lower wind of.4m/s, ventilation for the standing manikin increased by 53%(A) (29%, B) from the no wind condition, which was not comparable with the increase resulting from walking at all. However, when the wind speed was as high as 2.m/s, the ventilation increased up to 828% for jacket A (132%, B) from the no wind condition, and the ventilation increase due to walking was small. This indicated that the forced convection by the high wind was the major way of ventilation while the pumping effect of movement seemed no longer to have significant effect on ventilation. So, an interaction of these two effects was present. Moreover, for both jackets, the side and front ventilation of standing were obviously higher than the respective ones of walking although the whole ventilation of standing was lower than that of walking as expected. This could be considered that as the forward wind blowing air to the back, the arms swing may break the blowing and reduce the forced ventilation. Heat transfer coefficient h t As shown in Fig. 2(c) and (d), the heat transfer coefficient h t (the inverse of the total thermal insulation I t ) increased as the wind speed increasing and body walking. However, compared with the high speed wind of 2.m/s, the effect of natural convection and pumping was less. Moreover, values of h t shown in Fig. 2(c) were close to the respective ones in Fig. 2(d), indicating that the different air permeability of the jacket materials had no significant effect on heat loss. Usually, there are three ways for manikin s heat loss: radiation, convection and conduction. When the manikin stands still without wind, the major way of heat loss is radiation, heat loss of natural convection and conduction through fabric is very little. The increases of h t due to wind 15% for A and 13% for B were lower than those resulting from pumping effect. However, when the wind speed is very high, heat diffusion due to the forced convection comes to be as much as that of radiation because the increase was up to 132%. In addition, for two jackets, the value of the heat transfer coefficient at front of manikin standing in the wind of 2.m/s was higher than that when walking in the same wind. This was consistent with the ventilation results, confirming further that the ventilation resulting from forced convection is another major way for heat loss. Evaporative heat transfer coefficient h e

Fig. 2(e) and (f) show the evaporative heat transfer coefficient h e (the inverse of the vapor resistance). For jacket A, which was made of waterproof material and was supposed to be poor of vapor permeability, h e of the manikin standing without wind was very low because vapor diffusion occurred only through the natural convection through openings. On the contrary, h e for jacket B under the same situation was more than three times higher, showing that vapor penetration through fabrics in this condition played a far greater role in vapor transfer than natural convection (Havenith, Heus et al. 199). For both jackets, both walking and low wind enhanced vapor diffusion to similar extent, the increases agreed with the respective ventilation increases, proving the effect of pumping and enhanced surrounding convection in vapor diffusion. As the wind speed increasing, the pumping effect on vapor diffusion reduced. As shown in Table 1, the increase of h e was up to 27%, far higher than that of h t which was up to 119% although the increase of h e was not proportional to the increase of V either. In general, difference of h e between two jackets, which was up to 71%(stand without wind), was much greater than that of h t, which was lower than 1%. It confirmed that ventilation from penetration through fabrics plays a main role in vapor diffusion than it does in heat loss. Moreover, as show in Table 1, the difference of V between the two jackets under same condition was consistent with that of h e indicating that no matter how the movement and wind change the ventilation and vapor resistance, the penetration through fabric and its effect on vapor transfer seems to keep constant. CONCLUSIONS In this study, to investigate the effect of clothing ventilation on heat and vapor diffusion, ventilation of clothing microenvironment, thermal insulation and vapor resistance were measured on two jackets made of different materials worn on an articulated thermal manikin respectively. It was confirmed that clothing ventilation affects more on vapor resistance than it does on thermal insulation. Moreover, the effects of ventilation on heat and vapor diffusion varied because of different ways of ventilation arising, penetration through fabric was proved to be the most effective way in vapor diffusion although it seemed not helpful for heat diffusion. REFERENCES Havenith, G., R. Heus, et al. (199). Clothing ventilation, vapour resistence and permeability index: changes due to porture, movement and wind. Ergonomics 33(8): 989-15. Havenith, G., R. Heus, et al. (199). Resultant clothing insulation: a function of body movement, posture, wind, clothing fit and ensemble thickness. Ergonomics 33(1): 67-84. Lotens, W. A. and G. Havenith (1988). Ventilation of rainwear determined by a trace gas method. Environmental Ergonomics. I. B. Mekjavic, E. W. Banister and J. B. Morison. New York, Taylor & Francis: 162-176. Qian, X. M. and J. T. Fan (26). Interactions of the surface heat and moisture transfer from the human body under varying climatic condisitons and walking speeds. Applied Ergonomics 37: 685-693. Ueda, H. and G. Havenith (22). The effect of fabric air permeability on clothing ventilation. Environmental Ergonomics X, Fukuoka, Japan.