TP Description to be used for Customer Technical Specifications

Similar documents
TP Description to be used for Customer Technical Specifications

BPZM-MRD Nitrogen Injection System

Internal Arc Simulation in MV/LV Substations. Charles BESNARD 8 11 June 2009

Sizing, Selection, and Installation of Pressure-relieving Devices in Refineries

TECHNICAL SPECIFICATION

Infrared Thermography Inspection Guidelines. Date Issued:

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid

INF.41/Add.1/Rev.1. Economic Commission for Europe Inland Transport Committee

Analysis of Pressure Rise During Internal Arc Faults in Switchgear

SLOP RECEPTION AND PROCESSING FACILITIES

TP1 and TP2 Temporary Cone Shaped Strainers

ISO 4081 INTERNATIONAL STANDARD. Rubber hoses and tubing for cooling systems for internal-combustion engines Specification

Title: Pressure Relieving and Venting Devices Function: Ecology & Safety No.: BC Page: 1 of 7 Reviewed: 6/30/12 Effective: 7/1/12 (Rev.

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

MSC Guidelines for Pressure Vessels

C645A-E Pressure Switches

ISO INTERNATIONAL STANDARD. Cryogenic vessels Pressure-relief accessories for cryogenic service Part 1: Reclosable pressure-relief valves

RULES PUBLICATION NO. 119/P

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Manual Actuated Boiler Blowdown Valves

Computer Simulation Helps Improve Vertical Column Induced Gas Flotation (IGF) System

General Precautions for handling compressed gases

CP10 Sensor Installation and Maintenance Instructions

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

QUANTIFYING THE TOLERABILITY OF POTENTIAL IGNITION SOURCES FROM UNCERTIFIED MECHANICAL EQUIPMENT INSTALLED IN HAZARDOUS AREAS

Laboratory Safety Committee

Technical Data Sheet MF010-O-LC

ISO INTERNATIONAL STANDARD. Natural gas Measurement of properties Volumetric properties: density, pressure, temperature and compression factor

DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers

SAFETY FEATURES OF PORTABLE CRYOGENIC LIQUID CONTAINERS FOR INDUSTRIAL AND MEDICAL GASES

The API states the following about tube rupture for a shell-and-tube heat exchangers:

Installation Operation Maintenance

CAST IRON SAFETY VALVE TYPE 6301

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

AMT-Ex Dewpoint Transmitter

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

IEC April Authorized Sole Agent : PT. Wisma Niagatama Perkasa. Phone : (031) Fax. : (031)

i) Filtration machine, measuring equipment and other related machinery

Portable Oil Lube Air Compressors

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events

You Just Experienced an Electrical Failure, What Should You Do Next? By Don Genutis Hampton Tedder Technical Services

A new concept in the storage of liquefied chemical and petrochemical gases Zero leakage Zero fugitive emissions

Dry Gas Seal Rack CH-3185 Schmitten Tel Mail:

Relief Systems. 11/6/ Fall

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant

Wireless I/O, Connecting Remote Sensors in a Wide Range of Environments

Jupiter Type 4 Tube Owner s Manual

Intrinsic safety 101 hazardous locations

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

Steam generator tube rupture analysis using dynamic simulation

PV4 and PV6 Piston Valves

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Periodic Survey of Fuel Installations on Ships other than Liquefied Gas Carriers utilizing gas or other low flash point fuels

Safety instructions and operating manual

BGA244 Binary Gas Analyzer

1 SE/P-02. Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER

44 (0) E:

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

ISO INTERNATIONAL STANDARD. Gas cylinders Safe handling. Bouteilles à gaz Sécurité de manutention. Second edition

Organisation Internationale de Métrologie Légale. Direct mass flow measuring systems for quantities of liquids Annex C: Test report format

Electro-Pneumatic Converter YT-940 SERIES

Leader s Guide ERI Safety Videos

TECHNICAL DATA. Trimpac 257a. September 16, 2013

ISO INTERNATIONAL STANDARD

Guidelines for Clean Agent Fire Suppression Systems

Gas Lift Valve Testing

IMPLEMENTATION OF EIGA CARBON DIOXIDE STANDARDS

Hazard Operability Analysis

MODELING&SIMULATION EXTRAPOLATED INTERNAL ARC TEST RESULTS: A COUPLED FLUID-STRUCTURAL TRANSIENT METHODOLOGY

Power Transformer Maintenance. Maintenance Practices & Procedures for Substation Class Distribution Power Transformers

Mathieu Guertin. Morgan Schaffer Inc. Canada. Director Europe, Russia and Africa. A cost effective strategy for smart grid technology adoption

DF1 and DF2 Diffusers

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Fluid-Structure Interaction Analysis of a Flow Control Device

HYDROVEX TTT Membrane Flow Regulator

Improve Process Reliability

A guide to Part 10 of the

Standard Pneumatic Test Procedure Requirements for Piping Systems

ISO INTERNATIONAL STANDARD. Plain bearings Appearance and characterization of damage to metallic hydrodynamic bearings Part 1: General

USE OF RESIDUAL PRESSURE VALVES

SAFETY POLICY AND PROCEDURE MANUAL All Euramax Subsidiaries. Number K-3.0 Welding Safety Procedures

Pressure Piping Code-Industrial Piping. Part 6: Safeguarding

T e l N o : F a x N o : E m a i l : a i s h c m c - m e. c o m w w w. c m c - m e.

ISO INTERNATIONAL STANDARD. Small craft Liquefied petroleum gas (LPG) systems

ASME and PED Requirements for Drum Level Instrumentation. Presented by: Amir Hedayatnia Clark-Reliance Corp.

Description. Chassis. Cabinet. Long chassis - Type: Dimensions (mm): 2700 x 1200 x 1678

BERMAD Fire Protection Hydraulic Control Valves

Tube rupture in a natural gas heater

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

GUIDELINES. Systems. Pressure. Guidelines Acceptance of equipment, establishment of safe operating limits and fitness for service

23.1 Functions, Basic Configuration, and Interfaces

Master Control Systems, Inc. Variable Speed Fire Pump Controllers

Explosion Isolation. No matter what happens - nothing happens. / RICO Slide Valve RSV-D, RSV-G, RSV-P

SAFETY TRAINING LEAFLET 06 CARBON DIOXIDE

SIL Safety Manual. ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases. Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6

PREVENTION OF EXCESSIVE PRESSURE DURING FILLING OF CRYOGENIC VESSELS

Effective protection thanks to the latest technology

Transcription:

TP Description to be used for Customer Technical Specifications Transformer, On Load Tap Changer, Oil Cable Boxes Explosion and Fire Prevention, from 0.1 MVA

TP Description to be used for Customer Technical Specifications Document revisions Rev Ref. Date Done Checked Approved Revision Subject 1 ftpd01e 24/09/01 DS FM PM Creation Check revision 33 for revision history 12 ATPdd12e 19/07/07 DB ES PM Document general update 13 StTPdb13e 13/09/07 DB ES PM Drawings Legend Update 14 StTPdb14e 05/17/09 PFT FrCa PhMa TP evolution Revision not issued for coherency with other TP documentation 31 StTPdb31e 02/15/11 BrOB PFTa Amcc110516PhMa1 TP Evolution 32 StTPdb32e 06/12/12 PFTa FrCa Amcc120616PhMa16 Template and content update 33 StTPdb33e 005/06/14 FrCa AnMa Amcc140506PhMa15 Inclusion of NFPA Codes 34 StTPdb34e 08/31/15 OmAh,AnGo PhMa Amcc150901PhMa12 Content update 35 StTPdba35e 04/11/15 MeMe PhMa Amcc151104PhMa8 Text modification and annex Model reference: Fmpxgd33e Copyright STP 2016, Reference: AtTPga1509274Fe - TP Descrip for Client TS.docx, Dated January 12, 2017 Page 2 of 15

REFERENCED DOCUMENTS AVAILABLE ON REQUEST FROM SERGI TP No. Reference Marketing Documents [1] AtTPga TP description to be used for customers Technical Specifications [2] AtTPgfa TRANSFORMER PROTECTOR (TP) Brochure [3] AtTPgda World Reference [4] AtTPgg TP Presentation Outline No. Reference Technical Documents [5] AtTPpa Adaptation on New Transformers [6] AtTPpb Adaptation on Existing Transformers [7] AtTPpc On Site Installation, Commissioning, and Testing [8] AtTPpd Operation, Maintenance, and Periodical Test No. Reference TP Qualifications [9] AtTPrtfa Attestation from CEPEL Laboratory [10] AtTPrdab Recommended Practice for Fire Protection for Electric Generating Plants and High Voltage Direct Current Converter Stations, NFPA 850, 2015 edition Note* AtTPrdab document can be requested ONLY from www.nfpa.org No. Reference Scientific Publications [11] Amrpip2001.3e Transformer Relief Valves efficiency calculations by comparison to the TRANSFORMER PROTECTOR during short-circuits [12] Amrpip2004.2e Transformer Explosion and Fire Incidents. Guideline for Damage Cost Evaluation. Transformer Protector Financial Benefit [13] Amrpip2008.8e PWG Europe 2008, An Answer to Prevent Transformer Explosion and Fire, Live Test and Stimulations [14] Amrpip2013.1a Development of Two-Way Fluid Structure Coupling for Studying Power Transformers Subjected to Internal Dynamic Over-Pressure [15] Amrpip2015.1a Case Study on Mechanical Depressurization of Live Transformer Subject to Internal Arc [16] Amrpip2015.4ae Transformer Fast Tank Depressurization with Oil Bushing Cable Box Protections Disclaimer SERGI TP makes no express representation or warranty regarding the contents of this manual. We reserve the right to amend the manual or revise the product specifications described. The information contained in this manual is intended solely for the general use by our customers. Customers should be aware that the Transformer Protection field is subject to many patents. All of our customers should ensure their use of product does not infringe upon any patents. Contact Information SERGI TRANSFORMER PROTECTOR 186 Avenue du Général de Gaulle P.O. Box 90 78260 Achères France Tel: (+33) 1 39 22 48 40 Fax: (+33) 1 39 22 11 11 Web site: http://www.sergi-tp.com E-mail addresses: sergi@sergi-tp.com project@sergi-tp.com sales@sergi-tp.com quality@sergi-tp.com marketing@sergi-tp.com research@sergi-tp.com development@sergi-tp.com after.sales@sergi-tp.com administration@sergi-tp.com Copyright STP 2016, Reference: AtTPga1509274Fe - TP Descrip for Client TS.docx, Dated January 12, 2017 Page 3 of 15

TABLE OF CONTENTS SUMMARY... 5 1 COMPLETE TECHNICAL SPECIFICATION... 6 1.1 TRANSFORMER OR REACTOR EXPLOSION AND FIRE, ORIGINS, CAUSES AND CONSEQUENCES... 6 1.2 EQUIPMENT DESCRIPTION... 6 1.3 SIZING... 7 1.3.1 PRESSURE RISE CALCULATIONS... 7 1.3.2 DEPRESSURIZATION CALCULATIONS... 8 1.4 TESTS AND EXPERIENCE... 8 1.5 NFPA CODE... 8 1.6 TECHNICAL SPECIFICATION VERIFICATIONS... 9 2 SIMPLIFIED TECHNICAL SPECIFICATION... 9 2.1 EQUIPMENT DESCRIPTION... 10 2.2 SIZING... 10 2.2.1 PRESSURE RISE CALCULATIONS... 10 2.2.2 DEPRESSURIZATION CALCULATIONS... 10 2.3 TESTS AND EXPERIENCE... 10 2.4 NFPA CODE... 10 2.5 TECHNICAL SPECIFICATION VERIFICATIONS... 10 3 CONCISE TECHNICAL SPECIFICATION... 11 3.1 EQUIPMENT DESCRIPTION... 11 3.2 SIZING... 11 3.3 TESTS, EXPERIENCE, AND NFPA CODE... 11 3.4 TECHNICAL SPECIFICATION VERIFICATIONS... 12 4 SHORT TECHNICAL SPECIFICATION... 13 4.1 EQUIPMENT DESCRIPTION... 13 4.2 SIZING, TESTS, EXPERIENCE AND NFPA CODE... 13 4.3 TECHNICAL SPECIFICATION VERIFICATIONS... 13 5 APPENDIX... 14 5.1 FAST DEPRESSURIZATION SYSTEM TABLE FOR TECHNICAL SPECIFICATION VERIFICATIONS... 14 Copyright STP 2016, Reference: AtTPga1509274Fe - TP Descrip for Client TS.docx, Dated January 12, 2017 Page 4 of 15

SUMMARY The objective of this document is to help the electrical authorities, industries, consultants and engineering companies to include the TRANSFORMER PROTECTOR (TP) in their Technical Specifications. This technology of Transformers or Reactors Explosion and Fire Prevention complies with the 2015 edition of NFPA 850 norm. Four kinds of Technical Specifications are proposed: complete, simplified, concise, and short versions. In the proposed Technical Specifications, the wording «Transformer or Reactor, On Load Tap Changer (OLTC), and Oil Cable Box (OCB) / Oil Bushing Cable Box (OBCB) or Bushing Turrets (BT) Explosion and Fire Prevention» is being replaced by the term «Fast Depressurization System». As tests and sizing computation are the Fast Depressurization System cornerstone, gas generation during shortcircuit, the resulting dynamic pressure peak, pressure gradient and depressurization calculations are highlighted. Also, the Fast Depressurization System must comply with NFPA Code, the Fast Depressurization System must be passive - mechanical and must be activated without sensors or electrical actuators. The Appendix Table shall be used to evaluate each transformer and reactor, and depending on its components, must be adapted to points B2 and B3 of section B, Depressurization Set (DS) with Rupture Disk (RD) for all transformer and reactor elements. This table shall guarantee that the explosion and fire prevention system complies with the Technical Specification of the Fast Depressurization System. Copyright STP 2016, Reference: AtTPga1509274Fe - TP Descrip for Client TS.docx, Dated January 12, 2017 Page 5 of 15

1 COMPLETE TECHNICAL SPECIFICATION 1.1 TRANSFORMER OR REACTOR EXPLOSION AND FIRE, ORIGINS, CAUSES AND CONSEQUENCES Power transformers or reactors are among the most expensive equipment located in power plants and substations. They contain a large quantity of combustible substance, which can spray fire to nearby installations. Special attention should therefore be given to their protection. Transformer or reactor explosion and fire generally result from a fault inside the tank. This may be caused by overloads, short-circuits, or failure of the associated equipment such as On Load Tap Changer (OLTC), and Oil Cable Box (OCB) / Oil Bushing Cable Box (OBCB) or Bushing Turrets (BT). For an electrical arc, a huge volume of explosive gas is created during the first millisecond, 2.3 m³ (81.2 ft³) for the first mega joule. This gas generation creates one dynamic pressure peak and the transformer or reactor tank is violently shaken by accelerations reaching 400 g. This shockwave is travelling in the tank at a speed of the sound inside oil, 1,200 m/s (3937 ft/s). The first pressure peak of the resulting shockwave, initial amplitude greater than 10 bars, activates the Depressurization Set (DS) of the Transformer or Reactor, of the On Load Tap Changer (OLTC), and Oil Cable Box (OCB) / Oil Bushing Cable Box (OBCB) or Bushing Turrets (BT) before static pressure increases inside the tank and provokes tank explosion. Transformers and reactors are exploding because they are not protected against fast static pressure increase. The Pressure Relief Valve (PRV) is ineffective during short-circuit as every destroyed transformer or reactor tank is equipped with. In addition as transformer or reactors tanks do not comply with the ASME Codes, modifications of tank structure such as Local Tank Reinforcement or relying on tank elasticity are not likely to be effective explosion prevention solutions. Mechanical tank resistance versus time has never is been studied, and adopting such solutions is therefore very risky. The Fast Depressurization System shall comply with the NFPA 850 Code. The Fast Depressurization System shall allow the depressurization of the transformer or reactor after a few milliseconds from the time the electric fault has occurred. In order to avoid delays that will caused a transformer or reactor explosion, the Fast Depressurization System shall not depend on any sensor or electrical actuators coming from other protection. 1.2 EQUIPMENT DESCRIPTION The Fast Depressurization System shall be made of several sets, each playing a different role: The Depressurization Set (DS) with Rupture Disk (RD) shall prevent Transformer or Reactor, On Load Tap Changer (OLTC), and Oil Cable Box (OCB) / Oil Bushing Cable Box (OBCB) or Bushing Turrets (BT) explosion following a short circuit. Each Depressurization Set (DS) shall relieve the dynamic pressure within milliseconds and a Decompression Chamber (DC) favors high-speed depressurization. The depressurization time is the critical parameter. Therefore, the Depressurization Set (DS) diameter shall be calculated individually for each Transformer or Reactor type. The Inert Gas Injection Set (IGIS) is required for personal safety to avoid the bazooka effect caused by the explosive gas in contact with air (oxygen) when the tank is opened after the incident. The IGIS creates a safe environment in the Transformer or Reactor and the On Load Tap Changer (OLTC) after the depressurization process by injecting an inert gas flow, which also cools the tank. An Oil-Gas Separation Tank (OGST) shall collect the depressurized oil and explosive flammable gas to separate oil from gases. The Explosive Gas Evacuation Pipe (EGEP) shall then channel the gas to a safe and remote area. The efficiency and reliability of the Fast Depressurization System shall be ensured by the Depressurization Set (DS), which shall be opened by the first dynamic pressure peak of the pressure wave, avoiding transformer explosions before static pressure build-up. Copyright STP 2016, Reference: AtTPga1509274Fe - TP Descrip for Client TS.docx, Dated January 12, 2017 Page 6 of 15

No sensors and no electrical actuators shall be involved in the depressurization process because they add unacceptable operating delays. It is possible to separate the OGST from the transformer or reactor but the installation cost will be higher because: When the OGST function is integrated with the conservator there is no need for local installation; When independent from the transformer conservator, an additional tank and piping are necessary. The Transformer or Reactor, On Load Tap Changer (OLTC), and Oil Cable Box (OCB) / Oil Bushing Cable Box (OBCB) or Bushing Turrets (BT) Explosion Prevention Depressurization Set (DS) shall preferably be type Vertical (VDS) and located on the tank cover. If problems with high voltage clearances render impossible to fit the VDS on the tank cover, then a 45 degrees Depressurization Set (45 DS) or a Horizontal Depressurization Set (HDS) shall be installed. For smaller transformers, typically below 6 MVA such as bunker transformers, the TP can be installed without problem. The transformer manufacturer shall integrate the OGST in the conservator; the transformer conservator partition devoted to the OGST should have a volume of 0.5 m³ - 17.6 ft 3. If such configuration cannot be offered, the OGST can be remote but in this case the top of the OGST shall always be located 10 cm - 4 inches above the top of the transformer conservator. Several OGST arrangements are possible: SOGST, Sliced OGST, recommended and located in a slice of the conservator. WOGST, Wall mounted OGST, attached to the transformer or reactor firewalls. EOGST, Elevated OGST, elevated above the transformer conservator. Two types of injection of inert gas are possible, manual injection or automatic injection, depending on customer choice: The manual injection can be triggered from: o The control room. However, alarms should remind operators of the necessity to inject inert gas before a maintenance team starts working (bazooka effect). o The Inert Gas Injection Set (IGIS), close to the transformer or reactor in a safe area. Upon request, the Inert Gas Injection Quick Connector (option) can be provided to completely disconnect and cancel all risk of spurious injection into the transformer or reactor. For the automatic injection, two signals shall be required simultaneously to start up the Inert Gas Injection: o The integrated Rupture Disk Burst Indicator confirming the dynamic pressure and the beginning of the depressurization process; o One of the electrical protection signals, confirming the electrical fault of the protected Transformer or Reactor, of the On Load Tap Changer (OLTC), of the Oil Cable Box (OCB) / Oil Bushing Cable Box (OBCB) or Bushing Turrets (BT). The inert gas flow shall prevent air (oxygen) to be in contact with the explosive gases and shall further cool down the Transformer or Reactor, the On Load Tap Changer (OLTC), and the Oil Cable Box (OCB) / Oil Bushing Cable Box (OBCB) or Bushing Turrets (BT) as inert gas injection should run for 45 minutes. As a result, no more explosive gases remain when the inert gas injection is over. Then, maintenance teams can start working. The oil fire extinguishing system Inert Gas Drain and Stir shall back up the explosion and fire prevention for transformers with power range starting at 6MVA. The fire extinction backup Inert Gas Drain and Stir shall be activated by other signals than those used for the prevention method, except for the electrical protections: One from the Linear Heat Detector located on the transformer or reactor; One of the transformer or reactor electrical protections. 1.1 SIZING 1.1.1 PRESSURE RISE CALCULATIONS To avoid Transformer or Reactor, On Load Tap Changer (OLTC), and Oil Cable Box (OCB) / Oil Bushing Cable Box (OBCB) or Bushing Turrets (BT) explosion and fire, the supplier shall have specified likely locations of dielectric failure and subsequent arcing events within the oil-filled tank. These locations should be compared to Depressurization Set (DS) position and sizing to maximize the efficiency of depressurization. Copyright STP 2016, Reference: AtTPga1509274Fe - TP Descrip for Client TS.docx, Dated January 12, 2017 Page 7 of 15

Using a physical model capable of describing a multi-phase compressible fluid, quantitative predictions should be made for the following: The creation of high-pressure explosive and flammable gas within the tank during a low-impedance fault; The resultant pressure waves speed and amplitude; The subsequent increase in static, or average, pressure throughout the tank prior to the activation of the Fast Depressurization System. 1.1.2 DEPRESSURIZATION CALCULATIONS The physical model should accurately represent the following in order to properly simulate the Fast Depressurization System: The temporal and pressure gradient dependence of the opening of the Rupture Disks (RD); Transformer tank pressures as a function of time, taking into account relevant energy sinks such as thermal diffusion, viscosity, tank deformation, etc.; Resultant stresses and deformations on the transformer tank during the pressure drop; Oil-gas mixture volume to be evacuated to avoid transformer explosion and fire as a function of time. The Fast Depressurization System supplier shall provide Computerized Fluid Dynamic (CFD) and Fluid Structure Interactions (FSI) simulations for the transformer most probable low impedance energy fault (Mega Joule). 1.2 TESTS AND EXPERIENCE The supplier shall prove that the Fast Depressurization System: 10 years of experience with increased sales to 1,000 units. Certify that the Fast Depressurization System is activated with the first dynamic pressure peak before the static pressure rises and the transformer or reactor tank explode. A Test Certificate showing a campaign of at least 25 successful live tests of electric arcs events inside the transformer or reactor tank closed and full with oil, from which at least 5 have been done with arcs of more than 1 Mega Joule. This Test Certificate must be granted by a recognized and independent high voltage laboratory from a country different than the country of manufacture of the explosion and fire prevention system. Evidence that the explosion and fire prevention system has prevented the explosion of at least 8 transformers or reactors over 60MVA in 6 different countries with 8 Certificates of Successful Activation signed by the transformer or reactor owner. Insurance Policy over USD 10 million dollars to cover damages in case of transformer or reactor explosion with the Fast Depressurization System installed. 1.3 NFPA CODE The Fast Depressurization System must comply with the description for all Power Plants and Substations of the National Fire Protection Association, Code NFPA 850, 2015 edition. Therefore, the Fast Depressurization System must be passive mechanical and activated without sensors or electrical actuator. 1.4 TECHNICAL SPECIFICATION VERIFICATIONS The Appended Table should be used to evaluate each transformer or reactor and depending on its components it will be adapted as per B2 and B3 of Section B, "Depressurization Set (DS) with Rupture Disc (RD) for all elements of the transformer or reactor". This ensures that the explosion and fire prevention system complies with the Technical Specifications of the Fast Depressurization System. Copyright STP 2016, Reference: AtTPga1509274Fe - TP Descrip for Client TS.docx, Dated January 12, 2017 Page 8 of 15

2 SIMPLIFIED TECHNICAL SPECIFICATION 2.1 EQUIPMENT DESCRIPTION The Fast Depressurization System shall be made of several sets, each playing a different role: The Depressurization Set (DS) with Rupture Disk (RD) shall prevent a Transformer or Reactor, an On Load Tap Changer (OLTC), and Oil Cable Box (OCB) / Oil Bushing Cable Box (OBCB) or Bushing Turrets (BT) explosion following a short circuit. Each Depressurization Set (DS) shall relieve the dynamic pressure within milliseconds and a Decompression Chamber (DC) favors high-speed depressurization. The depressurization time is the critical parameter. Therefore, the Depressurization Set (DS) diameter shall be calculated individually for each Transformer or Reactor type. The Inert Gas Injection Set (IGIS) is required for personal safety to avoid the bazooka effect caused by the explosive gas in contact with air (oxygen) when the tank is opened after the incident. The IGIS creates a safe environment in the Transformer or Reactor, and the On Load Tap Changer (OLTC) after the depressurization process by injecting an inert gas flow, which also cools the tank. An Oil-Gas Separation Tank (OGST) shall collect the depressurized oil and explosive flammable gas to separate oil from gases. The Explosive Gas Evacuation Pipe (EGEP) shall then channel the gas to a safe, remote area. It is possible to separate the OGST from the transformer, but the installation costs are higher because: When the OGST function is integrated with the conservator there is no need for local installation; When independent from the transformer conservator, an additional tank and piping are necessary. The Transformer or Reactor, On Load Tap Changer (OLTC), and Oil Cable Box (OCB) / Oil Bushing Cable Box (OBCB) or Bushing Turrets (BT), explosion prevention Depressurization Set (DS) shall preferably be type Vertical (VDS) and located on the tank cover. If problems with high voltage clearances render it impossible to fit the VDS on the tank cover, then a 45 degrees Depressurization Set (45 DS) or a Horizontal Depressurization Set (HDS) shall be installed. For smaller transformers, typically below 6 MVA (such as bunker transformers), the TP can be installed. The transformer manufacturer shall integrate the OGST in the conservator; the transformer conservator slice devoted to the OGST should have a volume of 0.5 m³ - 17.6 ft 3. If such configuration cannot be offered, the OGST can be remote but in this case the top of the OGST shall always be located 10 cm - 4 in above the top of the conservator. Several OGST arrangements are possible: SOGST, Sliced OGST, recommended and located in a slice of the conservator. WOGST, Wall mounted OGST, attached to the transformer or reactor firewalls. EOGST, Elevated OGST, elevated above the transformer conservator. Two types of Inert Gas Injection are possible, manual injection which can be provided upon request with the Inert Gas Injection Quick Connector to completely cancel spurious injection into the transformer or automatic injection, depending on customer choice. The inert gas flow shall prevent air (oxygen) to be in contact with the explosive gases and shall further cool down the Transformer or Reactor, the On Load Tap Changer (OLTC), and the Oil Cable Box (OCB) / Oil Bushing Cable Box (OBCB) or Bushing Turrets (BT) as inert gas injection should run for 45 minutes. As a result, no more explosive gases remain when the inert gas injection is over. Then, maintenance teams can start working. The oil fire extinguishing system Inert gas Drain and Stir shall back up the explosion and fire prevention for transformers with power range starting at 6 MVA. Copyright STP 2016, Reference: AtTPga1509274Fe - TP Descrip for Client TS.docx, Dated January 12, 2017 Page 9 of 15

2.2 SIZING 2.2.1 PRESSURE RISE CALCULATIONS To avoid Transformer or Reactor, On Load Tap Changer (OLTC), and Oil Cable Box (OCB) / Oil Bushing Cable Box (OBCB) or Bushing Turrets (BT) explosion and fire, the supplier shall have specified likely locations of dielectric failure and subsequent arcing events inside the oil-filled tank. Using a physical model capable of modeling a multi-phase compressible fluid, quantitative predictions should be made for the gas volume generation as a function of arc energy, the resultant pressure wave speed and amplitude, and the subsequent increase in static, or average, pressure throughout the tank prior to the activation of the Fast Depressurization System. 2.2.2 DEPRESSURIZATION CALCULATIONS The physical model should accurately represent the following in order to simulate the Fast Depressurization System: The creation of explosive and flammable gas within the tank during a low-impedance fault; The temporal and pressure gradient dependence of the opening of the Rupture Disks (RD); Transformer or reactor tank pressures as a function of time, taking into account relevant energy sinks such as thermal diffusion, viscosity, tank deformation, etc.; Resultant stresses and deformations on the transformer tank during the pressure drop; Oil-gas mixture volume evacuated to avoid transformer explosion and fire as a function of time. The Fast Depressurization System supplier shall provide Computerized Fluid Dynamic (CFD) and Fluid Structure Interactions (FSI) simulations for the transformer most probable low impedance energy fault (Mega Joule). 2.3 TESTS AND EXPERIENCE The supplier shall prove that the Fast Depressurization System: 10 years of experience with increased sales to 1,000 units. A Test Certificate showing a campaign of at least 25 successful live tests before electric arcs events inside the transformer or reactor tank closed and full with oil, from which at least 5 have been done with arcs of more than 1 Mega Joule. This Test Certificate must be granted by a recognized and independent high voltage laboratory from a country different than the country of manufacture of the explosion and fire prevention system. Evidence that the explosion and fire prevention system has prevented the explosion of at least 8 transformers or reactors over 60MVA in 6 different countries with 8 Certificates of Successful Activation signed by the transformer or reactor owner. Insurance Policy over USD 10 million dollars to cover damages in case of transformer or reactor explosion with the Fast Depressurization System installed. 2.4 NFPA CODE The Fast Depressurization System must comply with the description for all Power Plants and Substations of the National Fire Protection Association, Code NFPA 850, 2015 edition. Therefore, the Fast Depressurization System must be passive mechanical and activated without sensors or electrical actuator. 2.5 TECHNICAL SPECIFICATION VERIFICATIONS The Appended Table should be used to evaluate each transformer or reactor and depending on its components it will be adapted as per B2 and B3 of Section B, "Depressurization Set (DS) with Rupture Disc (RD) for all elements of the transformer or reactor". This ensures that the explosion and fire prevention system complies with the Technical Specifications of the Fast Depressurization System. Copyright STP 2016, Reference: AtTPga1509274Fe - TP Descrip for Client TS.docx, Dated January 12, 2017Page 10 of 15

3 CONCISE TECHNICAL SPECIFICATION 3.1 EQUIPMENT DESCRIPTION The Fast Depressurization System shall be made of several sets, each playing a different role: The Depressurization Set (DS) with Rupture Disk (RD) shall prevent a Transformer or Reactor, On Load Tap Changer (OLTC), and Oil Cable Box (OCB) / Oil Bushing Cable Box (OBCB) or Bushing Turrets (BT) explosion following a short circuit. Each Depressurization Set (DS) shall relieve the dynamic pressure within milliseconds and a Decompression Chamber (DC) favors high-speed depressurization. The Inert Gas Injection Set (IGIS) is required for personal safety to avoid the bazooka effect caused by the explosive gas in contact with air (oxygen) when the tank is opened after the incident. The IGIS creates a safe environment in the Transformer or Reactor and the On Load Tap Changer (OLTC) after the depressurization process by injecting an inert gas flow, which also cools the tank. An Oil-Gas Separation Tank (OGST) shall collect the depressurized oil and explosive flammable gas to dissociate oil from gases. It is recommended to locate the OGST in the transformer or reactor conservator where a slice shall then be devoted for the OGST as often done for the On Load Tap Changer (OLTC) oil conservator. This transformer conservator slice shall have a volume of 0.5 m³ - 17.6 ft 3. The Explosive Gas Evacuation Pipe (EGEP) shall then channel the gas to a safe and remote area. It is possible to separate the OGST from the transformer. In this case, the top of the OGST must always be located 10 cm - 4 inches above the top of the conservator. The Inert Gas Injection can be manual, and including as an option the Inert Gas Injection Quick Connector, or automatic, depending on customer choice. 3.2 SIZING To avoid Transformer or Reactor, On Load Tap Changer (OLTC), and Oil Cable Box (OCB) / Oil Bushing Cable Box (OBCB) or Bushing Turrets (BT) explosion and fire, the supplier shall have specified likely locations of dielectric failure and subsequent arcing events inside the oil-filled tank. Using a physical model capable of describing a multi-phase compressible fluid, quantitative predictions should be made for the gas volume generation as a function of arc energy, the resultant pressure waves speed and amplitude, and the subsequent increase in static, or average, pressure throughout the tank prior to the activation of the Fast Depressurization System. The physical model should accurately model the opening of the Rupture Disks (RD), the oil-gas mixture outflow, the time-dependent transformer tank pressure drop, and the resultant stresses and deformations on the transformer tank. The Fast Depressurization System supplier shall provide Computerized Fluid Dynamic (CFD) and Fluid Structure Interactions (FSI) simulations for the transformer most probable low impedance energy fault (Mega Joule). 3.3 TESTS, EXPERIENCE, AND NFPA CODE The supplier shall prove that the Fast Depressurization System: 10 years of experience with increased sales to 1,000 units. A Test Certificate showing a campaign of at least 25 successful live tests of electric arcs events inside the transformer or reactor tank closed and full with oil, from which at least 5 have been done with arcs of more than 1 Mega Joule. This Test Certificate must be granted by a recognized and independent high voltage laboratory from a country different than the country of manufacture of the explosion and fire prevention system. Evidence that the explosion and fire prevention system has prevented the explosion of at least 8 transformers or reactors over 60MVA in 6 different countries with 8 Certificates of Successful Activation signed by the transformer or reactor owner. Copyright STP 2016, Reference: AtTPga1509274Fe - TP Descrip for Client TS.docx, Dated January 12, 2017Page 11 of 15

Complies with the description for all Power Plants and Substations of the National Fire Protection Association, Code NFPA 850, 2015 edition. This norm requires that the Fast Depressurization System must be passive mechanical and activated without sensors or electrical actuator. Insurance Policy over USD 10 million dollars to cover damages in case of transformer or reactor explosion with the Fast Depressurization System installed. 3.4 TECHNICAL SPECIFICATION VERIFICATIONS The Appended Table should be used to evaluate each transformer or reactor and depending on its components it will be adapted as per B2 and B3 of Section B, "Depressurization Set (DS) with Rupture Disc (RD) for all elements of the transformer or reactor". This ensures that the explosion and fire prevention system complies with the Technical Specifications of the Fast Depressurization System. Copyright STP 2016, Reference: AtTPga1509274Fe - TP Descrip for Client TS.docx, Dated January 12, 2017Page 12 of 15

4 SHORT TECHNICAL SPECIFICATION 4.1 EQUIPMENT DESCRIPTION The Fast Depressurization System shall be made of several sets, each playing a different role. The Depressurization Set (DS) shall prevent a Transformer or Reactor, On Load Tap Changer (OLTC), and Oil Cable Box (OCB) / Oil Bushing Cable Box (OBCB) or Bushing Turrets (BT) explosion following a short circuit. The Inert Gas Injection Set (IGIS) is required for personal safety to avoid the bazooka effect caused by the explosive gas in contact with air (oxygen) when the tank is opened after the incident. An Oil-Gas Separation Tank (OGST) shall collect the depressurized oil and explosive flammable gas to separate the two. The recommended OGST location is a partition of the transformer conservator, as is often done for the OLTC oil conservator. The Explosive Gas Evacuation Pipe (EGEP) shall then channel the gas to a safe, remote area. 4.2 SIZING, TESTS, EXPERIENCE AND NFPA CODE To avoid Transformer or Reactor, On Load Tap Changer (OLTC), and Oil Cable Box (OCB) / Oil Bushing Cable Box (OBCB) or Bushing Turrets (BT) explosion and fire, the supplier shall have specified likely locations of dielectric failure and arcing inside the oil-filled tank. A physical model describing a multi-phase compressible fluid should predict the gas generated by the arc, the resultant pressure waves speed and amplitude, and the subsequent increase in static, or average, pressure throughout the tank prior to the activation of the Fast Depressurization System. The model should describe the opening of the Rupture Disks (RD), the oil-gas mixture outflow, the timedependent transformer tank pressure drop, and the resultant stresses and deformations on the transformer or reactor tank. The Fast Depressurization System supplier shall provide Computerized Fluid Dynamic (CFD) and Fluid Structure Interactions (FSI) simulations for the transformer most probable low impedance energy fault (Mega Joule). The supplier shall prove that the Fast Depressurization System: 10 years of experience with increased sales to 1,000 units. A Test Certificate showing a campaign of at least 25 successful live tests of electric arcs events inside the transformer or reactor tank closed and full with oil, from which at least 5 have been done with arcs of more than 1 Mega Joule. This Test Certificate must be granted by a recognized and independent high voltage laboratory from a country different than the country of manufacture of the explosion and fire prevention system. Evidence that the explosion and fire prevention system has prevented the explosion of at least 8 transformers or reactors over 60MVA in 6 different countries with 8 Certificates of Successful Activation signed by the transformer or reactor owner. Complies with the description for all Power Plants and Substations of the National Fire Protection Association, Code NFPA 850, 2015 edition. This norm requires that the Fast Depressurization System must be passive mechanical and activated without sensors or electrical actuator. Insurance Policy over USD 10 million dollars to cover damages in case of transformer or reactor explosion with the Fast Depressurization System installed. 4.3 TECHNICAL SPECIFICATION VERIFICATIONS The Appended Table should be used to evaluate each transformer or reactor and depending on its components it will be adapted as per B2 and B3 of Section B, "Depressurization Set (DS) with Rupture Disc (RD) for all elements of the transformer or reactor". This ensures that the explosion and fire prevention system complies with the Technical Specifications of the Fast Depressurization System. Copyright STP 2016, Reference: AtTPga1509274Fe - TP Descrip for Client TS.docx, Dated January 12, 2017Page 13 of 15

5 APPENDIX 5.1 FAST DEPRESSURIZATION SYSTEM TABLE FOR TECHNICAL SPECIFICATION VERIFICATIONS N DESCRIPTION REQUIERED GUARANTEE EXPLOSION AND FIRE PREVENTION SYSTEM ON TRANSFORMER AND REACTOR A. Fast Depressurization System Yes A.1 Complies with NFPA 850, 2015 Edition Yes A.2 "Passive - Mechanical" activated without sensors or electrical actuators Yes B. Depressurization Set (DS) with Rupture Disk (RD) for all transformer or reactor elements Yes B.1 Tank Yes B.2 On Load Tap Changer (OLTC) Yes B.3 Oil Cable Box (OCB) / Oil Bushing Cable Box (OBCB) or Bushing Turrets (BT) Yes C. Additional depressurization functions to avoid the bazooka effect Yes C.1 Inert Gas Injection Set (IGIS) Yes C.2 Oil-Gas Separation Tank (OGST) Yes C.3 Explosive Gas Evacuation Pipe (EGEP) Yes D. For physic and mathematic investigations A multi-physic model must calculate the depressurization based on time and energy Yes D.1 Fluid Structure Interaction (FSI) Simulations Yes D.2 Computerized Fluid Dynamic (CFD) Simulations Yes E. Test Certificate for electrical arcs inside a transformer or reactor tank closed full of oil granted by a recognized and independent High Voltage Laboratory from a country different than the country of manufacture Yes E.1 Twenty - Five (25) Succesful Live Tests Yes E.2 Five (5) Tests with electrical arcs of more than 1 Mega Joule Yes F. Sucessful Activations during the transformer or reactor operation Successful Activation Certificates signed by the owner of the transformer or reactor Yes F.1 Eight (8) Certificates of six (6) different countries Yes G. Insurance Policy Yes Insurance Policy for more than USD ten (10) million american dollars covering damages in case of transformer or reactor G.1 Yes explosion equipped with the Fast Depressurization System. AFFIDAVIT The company and its legal representative guarantees and certifies that the explosion and fire prevention system for the transformers/reactors complies with what it is s in the table above, assuming the responsibility of the legal and economic consequences for declaring false data. Company Name: Legal Representative Name: Identification Card Number: Signature of the Company Legal Representative: Yes Copyright STP 2016, Reference: AtTPga1509274Fe - TP Descrip for Client TS.docx, Dated January 12, 2017Page 14 of 15

SERGI TRANSFORMER PROTECTOR 186 Avenue du Général de Gaulle P.O. Box 90 78260 Achères France Tel: (+33) 1 39 22 48 40 Fax: (+33) 1 39 22 11 11 Copyright STP 2016, Reference: AtTPga1509274Fe - TP Descrip for Client TS.docx, Dated January 12, 2017Page 15 of 15