Swim Spa Pre-delivery Guide

Similar documents
SPA WORLD. Pre- delivery Guide

You are now the proud new owner of an Alpine Swim Spa!

Step-by-Step Planning Guide

Blue Whale Spa :- Site Preparation and Delivery

Hot Tub Pre-Delivery Guide

LoneStar Fiberglass Pools. Do-It-Yourself. Installation Manual

ARCHITECT INSTALLATION GUIDELINES FOR RESIDENTIAL TRITON INSTALLATIONS

ARCHITECT GUIDELINES 1000 T

ARCHITECTURAL GUIDELINES FOUR-PIECE COMMERCIAL

ARCHITECTURAL GUIDELINES FOUR-PIECE RESIDENTIAL

ARCHITECTURAL GUIDELINES ONE-PIECE COMMERCIAL

ARCHITECTURAL GUIDELINES 1000 S

RESIDENTIAL SWIMMING POOLS AND SPAS A GUIDE FOR HOMEOWNERS

Delivery Step by Step Call now for expert advice: Lines open:

D E L U X E S E R I E S. Your Hot Tub Pre-Delivery Guide D E L U X E

Step 1. PLANNING FOR THE INSTALLATION TOOLS REQUIRED

Your Hot Tub Pre-Delivery Guide

PRE-PURCHASE DECISIONS...1 BEFORE DELIVERY...1

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

Bulletin Swimming pool, hot tub and spa installations Rules , , , , , and

HOA Specifications and User Guidelines for Hot Tubs at WW3HOA

In Vessel Composter Installation & Commissioning Manual

LUX3 INSTALLATION & SETUP GUIDE INSTALLATION & SETUP GUIDE

Swimming Pools, Hot Tubs and Spas

FINDLAY TOWNSHIP BUILDING INSPECTION DEPT

The purpose of this brochure is to explain to owners and contractors the City of Burnaby s requirements for private swimming pools.

RESIDENTIAL SWIMMING POOL REQUIREMENTS

Swimming Pool Requirements

AMITY TWP POOL REQUIREMENTS

CHAPTER 8 STAKING SIGNALS AND LIGHTING FIELD GUIDE. 8.1 Staking Traffic Control Signal Systems

O r i g i n a l. E n d l e s s P o o l. P l a n n i n g G u i d e

STAKING TRAFFIC CONTROL SIGNAL SYSTEMS

LAZY RIVER 3 3 PUMP LOCATION

TOWN of CHEEKTOWAGA Permit Application for Swimming Pools, Hot Tubs, or Personal Spas

Siting and Installation Manual

RESIDENTIAL SWIMMING POOL

Cool Springs and Clarksville store call Cookeville store call Bowling Green store call

Hot Tub Buyer s Guide: Questions for First-Time Shoppers. A complete resource every hot tub shopper needs!

Life Smart Spas Frequently Asked Questions

City of Cerritos SWIMMING POOL, SPA AND EQUIPMENT APPLICATION. (Please print or type) Name: Phone: ( )

22. Specialty Valves.

SWIMMING POOLS/SPAS/HOT TUBS PLAN REVIEW GUIDE SHEET

Swimming Pool Requirements Packet

New AQF Filter Polymer Filtration System

NICROS-GRANITPANELS INSTALLATION MANUAL

Swimming Pool Requirements

Village of Lombard. Building Division/Community Development Department 255 E. Wilson Avenue Lombard, IL Tel: Fax:

2018 MODEL. SwimFit / SwimExpert INSTALLATION GUIDE

Check with local zoning official for property line distance requirements.

2005 Spa Pre-Delivery Guide

Original. Planning Guide

Waterblade Installation Manual

COMPLIANCE WITH STANDARDS, REGULATIONS AND ORDINANCES

Life Smart Spas Frequently Asked Questions LS600DX

POOL AND SPA REPLASTERING AND/OR REMODELING REQUIREMENTS

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

help make your spa installation a success Commissioned by Caldera Spas

Swimming Pools, Spas & Hot Tubs Construction requirements for outdoor private swimming pools (in-ground and above-ground), spas and hot tubs

RESIDENTIAL SWIMMING POOLS, SPAS and HOT TUBS PERMITTING and INSPECTIONS GUIDE

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

GENERAL NOTES FOR SWIMMING POOLS AND SPAS

Permit and Inspection Requirements for Swimming Pools

It features some design elements and details that you should consider and include on your completed swimming pool plan.

SWIMMING POOL REQUIREMENTS

150 X 93 / 381 cm x cm* / cm* 1,489 US gallons / 5,635 Liters. 14,403lbs / 6,535 Kg lbs / 900 Kg. * +/- tolerance of 1/4

Acknowledgement must be given for the assistance provided by Barry Hutchens, Kenji Iwanaga, and AJ Murguia in preparing this booklet.

THE ULTIMATE HOT TUB BUYERS GUIDE WORK HARD, PLAY HARD, REJUVENATE HARD.

Fencing your spa or swimming pool

CONFER ABOVE GROUND CURVE STEP / ABOVE GROUND CURVE STEP SYSTEM ASSEMBLY AND INSTALLATION MANUAL

Solus Spa Solus Spa Solus Spa

THE HOME OF BEAUTIFUL POOL DESIGN

174 x 93 / cm x cm / cm US gallons / 6563 L. 16,766 lbs / 7,607 Kg. 2,302 lbs / 1,044 Kg

City of Lockport Above Ground Pool Regulations

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

2018 MODEL. SwimFit / SwimExpert INSTALLATION GUIDE

Environmental Services Buller District Council 4-6 Brougham Street PO Box 21, Westport 7866 Telephone

Fencing your spa or swimming pool

List all key terms and acronyms used in the procedure, and their definitions.

Heat pumps for swimming pools

CITY OF TORONTO. BY-LAW No

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Spas Hotels/Resorts Apartments & Condominiums Campgrounds Health Clubs Medical Clinics Waterparks

220 / 93 / 558 / 236 cm / cm US gallons / 9038 L. 22,948 lbs / 10,412 Kg lbs / 1374 Kg

POOL FENCING A Guide to the Fencing of Swimming Pools Act 1987

$ Plan Review Fee when Permit Application is submitted HOT TUBS AND SPAS BUILDING PERMIT APPLICATION. COST: $80.

186 x 93 / 473 cm x cm / cm. 1,944 US gallons / 7,358 L. 18,677 lbs / 8,474 Kg. 2,460 lbs / 1,116 Kg

Visit:

CUSTOMER ASSISTANCE GUIDE BUILDING PERMIT APPLICATION SUBMITTAL REQUIREMENTS

Private Swimming Pool Permit Application

brings water to life innovative design, precision engineering and quality production Coverstar Automatic safety cover

SWIMMING POOL & SPA DOCUMENT SUBMITTAL LIST

Swimming Pool Installation

Fence and Swimming Pool Permit Guidelines

MODEL CCX-AG CURVE STEP / CURVE STEP SYSTEM

Treated w/ mildew and UV inhibitors to keep its beauty through all seasons

CONFER IN-GROUND CURVE STEP / IN-GROUND CURVE STEP SYSTEM ASSEMBLY AND INSTALLATION MANUAL

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS CMP SERIES. Brilliant Wonders LED BUBBLERS

Transcription:

Swim Spa Pre-delivery Guide

Hello! This document is designed to provide all the information you need to ensure the smooth delivery and installation of your spa or swim spa. Please read it carefully and talk to your sales person immediately if you require any further clarification. Free phone 0800 400 772 for all enquiries.

Contents Site selection Power requirements Electrical Installation Wire placement Concrete slab Fencing requirements Cover lifters Delivery of your swim spa - Cranes and hiabs Above ground installations Installing your swim spa into the ground Heat pump placement and installation Before your spa is delivered _01

Site selection. When finding the best location for your swim spa, think safety first: Never position a spa, swim spa, or any other type of pool near overhead cables or power lines. Make sure that if the swim spa is to be positioned near a slope, dip, trough or below ground level, there is adequate drainage for any ground water to run off. Damage caused by flooding is not covered under warranty. If you are building a deck around the swim spa, sinking it slightly, or placing it against a wall, ensure easy access is provided to the service panel. This is almost always on the same side of the swim spa as the touch pad. You must ensure that it is possible to access all sides of the swim spa for maintenance if required. At least is required on all sides. Proper planning will enhance the enjoyment of your spa experience and protect your privacy. Do you need quick and easy access? If so, placing swim spas close to the house or changing room is ideal. Do you have a view to admire from the swim spa? If so; consider how the swim spa can be best rotated so the seating faces the view without obstructing the service panel. Swim spas should also be 200mm proud of the top of any deck to allow for the cover to be clipped to the side of the spa. 50mm 200mm 50mm NOTE: Any exceptions to the above should be approved by Vortex Spas. _02 _03

Power requirements. For most, the reason for buying a swim spa is to be able to swim in it! Beside is a table outlining the maximum and minimum power requirements for each model of swim spa. Model Maximum Required Minimum Required Total Required As such, swim spas have 2 or more large pumps, that drive the swim stream. When not in use, swim spas use surprisingly little power, however with the swim pumps on, this power draw increases and so adequate power supply is crucial to get the most from your swim spa. Please note that if you do not have the maximum power requirement available, the swim spa will be set up so that the heater will turn down when one or more of the swim pumps are activated. Within Australia and New Zealand, these will be single-phase power supplies, however, the swim spa can be configured to use either 2 or 3 phases if required. Single zone Plunge models Single zone Pro models Single zone Extreme models 15 amps 32 amps 45 amps 15 amps 32 amps 45 amps 15 amps 32 amps 45 amps Hydrozone Pro models 32 amps + 15 amps 32 amps + 15 amps 45 amps Hydrozone Extreme models 45 amps + 15 amp 45 amps + 15 amp 60 amps NOTE: The above assumes that a heat pump is fitted. All Dual Zone have 2 separate controllers and require individual electrical connections. _04 _05

Electrical installation. Please use a qualified electrician. In the comments section of your invoice, the salesperson should have noted the amount of amps that your spa requires to operate. If you cannot see this note, please call your salesperson as soon as possible. This information is what you need to provide to your electrician for them to quote correctly. Please only use a qualified electrician who will be able to recommend the safest and most efficient installation method. 10 and 15 amp spas. Spas that are listed as 10 or 15 amps will require an outdoor waterproof power point with an earth leakage protection device (unless there is one already fitted to your switch board). There is a power lead on these spas that is approximately 3 metres long and located under the touch pad. This means for the cord to reach the power point you need to position the touch pad side of the spa to within 2m of the power point. (Please check with your electrician but in most cases you cannot have the power point closer than 1m to the spa for safety reasons). Spas requiring 32 amps or more. 2m If your spa is 32 amps or more, it will need to be hard wired by your electrician. This typically means that your electrician is required to make two trips: the first to do initial connection work and the second to connect the wires after delivery and before handover. VIP deliveries require the electrician on site on the day of delivery before filling and handover can commence. _06 _07

Wire placement. If you are preparing a new base for your spa or installing onto a deck and would like to conceal the power please follow these instructions: Valid on all swim spas made after 7th February 2018: Mark out where your spa will sit on the base using the provided dimensions. Measure 1000mm from the touchpad end of the swim spa and 400mm in from the right side of the spa (while facing the key pad end of the swim spa). You can have your electrician run the conduit and cable before the concrete is poured so that it can enter through the base of the swim spa at the noted location which will conceal the power entrance. NOTE: The conduit should not stick above the concrete more than 150mm. When the swim spa arrives, you will see the 200mm hole in the base of the swim spa which will be covered by insulation. The insulation has a slot in it and the conduit can be pushed up through the insulation as the swim spa is placed. NOTE: Most local authorities insist that your swim spa is separated from it s isolation switch by at least 1 metre. Your electrician should be aware of this and should be consulted prior to settling on the exact position of your swim spa. 400mm 1000mm O200mm Concrete Slab Swim End Key-Pad Spa End WIRE PLACEMENT _08 _09

Concrete slab. When a swim spa is full, it often weighs more than 9 tonnes. As such, it needs a very firm base. We recommend 150mm of reinforced concrete. In terms of the overall dimension, we recommend at least 600mm extra on each side of the swim spa meaning that the minimum pad size should be 1200mm larger than the swim spa itself. This extra is not necessarily required if the swim spa is being decked around or sunken below ground level. If you wish to use swim spa steps to access the spa, these should be placed at the spa end so that you can step onto the spa seating to make access and egress easy. The swim spa steps measure 1200mm wide, 730mm deep and 795mm high so take this into account when planning your pad. Fencing requirements. Whilst there is some variation from councils regarding fencing requirement or spas, you should assume that the council will want to see a fence of 1.2M around the swim spa. This can often be avoided if the swim spa is installed above ground, as swim spas are generally more than 1.2m high. However if this is done, the council will require that the steps are removable and there are not other items around the spa that can be used as a step. This includes heat pumps and heat pump plumbing. As such, if you wish to avoid fencing your swim spa by leaving it completely above ground, the heat pump will need to be installed at least 1.2m away from the side of the swim spa. Fencing requirements are the responsibility of the home owner. Cover lifters. If a cover lifter is to be fitted, allow for the lifter to fold back out of the way and 150mm each side for the lifter arms. Steps 730mm Swim End 1200mm Spa End 1000mm 150mm 150mm 1200mm Typical concrete pad layout Heat Pump _10 _11

Delivery of your swim spa - Cranes and hiabs. Due to the weight of your swim spa, it will be delivered using a hiab crane, mounted on the delivery truck, or a larger separate crane. The maximum reach of a truck mounted hiab crane is usually no more than 12 metres but this will depend on where the swim spa is positioned in relation to the orientation of the truck. I.e. a hiab crane may be able to place the swim spa 12m from the rear of the truck, but not necessarily off the side. Bare in mind that trucks with hiab cranes are usually quite large and so consideration needs to be made as to whether they will fit up a normal driveway. Stand alone, truck mounted cranes will have a much larger reach up to 44m. However these cranes are often very wide and very heavy with many not being able to drive on a domestic driveway. If they need to be positioned at the street, then often a traffic control plan will be required. It is very unlikely that a crane of this type will be able to operate from grass or off road, but some all terrain cranes are available. Whilist Spas can often be lifted without spreader bars, this is at the discretion of the crane company. We insist that these are used for lifting swim spas. It is the sole responsibility of the crane company to ensure that the spa is moved without damage, and it is your responsibility to ensure that they are suitably insured for any damage occuring to either your spa or property. Vortex Spas or employees are not responsible for any damage to persons or owners while the spa is in the air or while the crane is operating. Please note that it is virtually impossible to move a swim spa by hand. Once in position, it is there to stay and so it is vital that it is placed in it s final position whilst the crane or hiab truck is on site. _12 _13

Above ground installations. Installing your swim spa into the ground. This is the most common and certainly the easiest method of installing a swim spa. You simply lay a concrete pad as described above and crane the swim spa onto it. You then have a choice of either using the removable steps for access, thereby potentially eliminating the need for fencing, or building decking up to the swim spa as seen to the right. NOTE: If you are decking up to the swim spa, the sides of the swim spa must still be accessible and most importantly, there must be access to the equipment bay at the spa seating end of the swim spa. This can be achieved using removable decking sections. When excavating your hole, ensure that you allow an extra from each side of the swim spa and an extra 1000mm at the spa end for access to the equipment bay. If a heat pump or pit drain is being installed below ground level, sufficient room must also be allowed for these items.as such, a swim spa measuring 4m x 2.3m would require a hole that is 5.5m x 3.3m. The lockable hard cover requires a 200mm clearance from the top of the spa to the lock fittings on the spa for correct locking. 1000mm Spa End Spa End Heat Pump Typical below ground layout for a swim spa _14 _15

Installing your swim spa into the ground. 1. The walls then have to be retained, this can be done with timber, bricks or concrete. 2. Drainage of the pit needs to be fitted. A full length drain should be used that either gravity drains to the outside of the pit, or drains into a sump with a automatic submersible pump fitted. 5. If you do not have the option of gravity draining the pit, a sump pump should be installed. These are a very reliable and relatively inexpensive solution. Your pit is now ready for the swim spa to be installed. 6. Your swim spa can now be craned into position. 7. Once the swim spa is in position, you can complete the decking up to the spa. NOTE: It is important that access is available to all sides and most importantly, the equipment bay of your swim spa. This can be achieved using removable decking panels. Failure to take this into account could lead to significant costs if your swim spa needs to be serviced in the future. For the lockable hard cover to be locked correctly a 100mm clearance from the top of the spa to the lock fittings is required. 3. The base needs to be concreted make sure of your heights and what height you want the swim spa to finish so as to sit flush in relation to any decking. 4. (Optional) Using a liquid filler, fill all the gaps in between the timbers and then paint using a black seal waterproof paint.this will stop any see page from the dirt in to the pit. _16 _17

Heat pump placement and installation. Heat pumps are a fantastic method of reducing the heating cost of your swim spa. Separate detailed installation instructions are available for your swim spa if you have chosen this option, but following are a few considerations when selecting the placement of your heat pump: The 8.8kW heat pump measures 955mm wide x 305mm wide x 550mm high. The heat pump is connected to your swim spa with 2 x 40mm plumbing pipes, a power supply (the heat pump takes its power from the spa s controller) and a data cable. These enter the side of the swim spa via holes that are cut in the swim spa s cabinet by the installer The heat pump must be at least 1.2m from the edge of the swim spa but no more than 3m away The heat pump should be installed at the same level as the base of the swim spa. If your swim spa is being sunk into a pit, then the heat pump should be installed in the pit with its back side 300mm off the edge of the pit, and the front side facing across the front side of the swim spa to ensure it has adequate air flow. The heat pump must sit on either a concrete base, or well laid concrete paving stones. The most common solution is to pour a pad extension for the heat pump when the main pad is poured The heat pump moves a lot of air and so both the back and front of the heat pump must be completely unobstructed. The manufacturer recommends 300mm at the back, each side and 2.5m to the front of the unit. The heat pump is very quiet (49dB), but you should avoid placing your heat pump outside a bedroom window for example. If you wish to avoid fencing you spa, the heat pumps plumbing should be fitted low to the ground so as not to be used as a step. Heat pumps should be secured to the concrete pad using dynabolts or similar. 300mm 2 _18 _19

Notes Notes _20 _21

Free phone 0800 400 772 Information included in this document is to be used as a guide only. It is the owners responsibility to check that all local building, electrical and government guidelines are complied with. Vortex Spas New Zealand accepts no responsibility or liability for non-compliance with any government or local body requirements. 07/02/18 V2