Workshop 302-compressor-anti-surge

Similar documents
Dynamic Simulation for T-9 Storage Tank (Holding Case)

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

Dynamics and Control of Chemical Processes Solution to Lab #8 Shutdown of C4-C5 separation section

Separation of Acetone-Water with Aspen HYSYS V8.0

Ammonia Synthesis with Aspen Plus V8.0

Operators of petroleum plants

1 PIPESYS Application

NORDCALC Introduction... 2 Registration... 2 Flow Calculations tab Torque Calculation & Actuator Mounting Data tab... 21

DSTWU A Shortcut Distillation Model in Aspen Plus V8.0

Benefits of Detailed Compressor Modeling in Optimizing Production from Gas-Lifted Fields. Manickam S. Nadar Greg Stephenson

How to Combat Process Disturbances and Interactions

Heat of Vaporization with Aspen Plus V8.0

Start up XXX from normal shutdown Introduction

A NEW PROCESS FOR IMPROVED LIQUEFACTION EFFICIENCY

Dynamic Analysis of a Multi-Stage Compressor Train. Augusto Garcia-Hernandez, Jeffrey A. Bennett, and Dr. Klaus Brun

UNIVERSITY OF WATERLOO

CENTER PIVOT EVALUATION AND DESIGN

Constant pressure air charging cascade control system based on fuzzy PID controller. Jun Zhao & Zheng Zhang

Pressure Control. where: p is the pressure F is the normal component of the force A is the area

DISTILLATION PRESSURE CONTROL TROUBLESHOOTING THE HIDDEN PITTFALLS OF OVERDESIGN

S-CO 2 Brayton Recompression Loop Design and Control

2. Determine how the mass transfer rate is affected by gas flow rate and liquid flow rate.

Recovery from a Process Saturation Condition. Benefits of Using DeltaV PIDPlus

14 April 2016 Dr. John Hedengren 350 CB Brigham Young University Provo, UT 84606

CONTROL VALVE WHAT YOU NEED TO LEARN?

Manual for continuous distillation

Tutorial. BOSfluids. Relief valve

Aspen HYSYS. Dynamic Modeling Guide

LABORATORY EXERCISE 1 CONTROL VALVE CHARACTERISTICS

USER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

Valve Sizing Considerations. Steven Hocurscak Metso Automation

NATIONAL UNIVERSITY OF SINGAPORE. EE3302/EE3302E Industrial Control Systems E1: ADVANCED CONTROL SYSTEMS

INTEROFFICE MEMORANDUM MODIFICATIONS TO DEW POINT CONTROL PROCESS

PRESSURE SURGES IN PIPELINES

Acoustical Modeling of Reciprocating Compressors With Stepless Valve Unloaders

ACV-10 Automatic Control Valve

The Discussion of this exercise covers the following points:

Removing nitrogen. Nitrogen rejection applications can be divided into two categories

COMPRESSORS WITH SIDE STREAM

By: Eng. Ahmed Deyab Fares - Mobile:

Characterizers for control loops

PIG MOTION AND DYNAMICS IN COMPLEX GAS NETWORKS. Dr Aidan O Donoghue, Pipeline Research Limited, Glasgow

Transient Analyses In Relief Systems

DP Ice Model Test of Arctic Drillship

1.2 Example 1: A simple hydraulic system

Using the CONVAL software for the petrochemical plant control valves checking. Case study

Fundamentals of Turboexpanders Basic Theory and Design

Start-up of the Three-shaft Closed Loop

CHE 306 Stagewise Operations

Implementing Mid Ranging in a DCS Environment

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

Industrial Compressor Controls Standard Custom

RICK FAUSEL, BUSINESS DEVELOPMENT ENGINEER TURBOMACHINERY CONTROL SYSTEM DESIGN OBJECTIVES

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

Flotation Control & Optimisation

Gerald D. Anderson. Education Technical Specialist

Understanding Centrifugal Compressor Capacity Controls:

Exercise 4-2. Centrifugal Pumps EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Pumps

GeQuip Joule Thomson Plant. Process Description (see Figure 1) Standard Control Instrumentation

Fit for Purpose Compositional Input for Allocation Using Equations of State Thomas Hurstell, Letton Hall Group

EXPERIMENT 1 AIR PRESSURE CONTROL SYSTEM

Technical Information Conducal CLY421

Cover Page for Lab Report Group Portion. Head Losses in Pipes

FIG: 27.1 Tool String

16. Studio ScaleChem Calculations

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Process Modeling using UniSim Design

Heat Pump Connections and Interior Piping

CCT-7320/ROC-2313 Reverse Osmosis Controller

UNIQUE ADVANTAGES OF PIPENET

Controlling the prefeeder

Pump-Fan-Compressor Sizing

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING

Chapter 14 Coal Boiler Flue Gas Scrubber II

Anti Surge Control of Centrifugal Compressor at PT. Pertamina EP Asset 2 Field Pendopo

Ingersoll Rand. X-Series System Automation

Boyle s Law: Pressure-Volume Relationship in Gases

Pressure on Demand. Air Pressure Amplifiers

( ) ( ) *( A ) APPLICATION DATA. Procidia Control Solutions Coarse/Fine Control. Split-Range Control. AD Rev 2 April 2012

FAULT DIAGNOSIS IN DEAERATOR USING FUZZY LOGIC

Application of CHE100 in Frequency Conversion Alteration of Air Compressor System

SUPERSONIC GAS TECHNOLOGIES

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

Multiphase MixMeter. MixMeter specification. System Specification. Introduction

Process Simulator Evaluates Blower and Valve Control Strategies for WWTP Aeration

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

Lab Procedure. PumpLab TM Centrifugal Flow/ Process Control System

ENSURING AN ACCURATE RESULT IN AN ANALYTICAL INSTRUMENTATION SYSTEM PART 1: UNDERSTANDING AND MEASURING TIME DELAY

Diagnosis of Fuel Evaporative System

ROSE-HULMAN INSTITUTE OF TECHNOLOGY Department of Mechanical Engineering. Mini-project 3 Tennis ball launcher

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

Process Dynamics, Operations, and Control Lecture Notes - 20

Quiz #1 Thermodynamics Spring, 2018 Closed Book, Open Appendices, Closed Notes, CLOSED CALCULATORS

Instructions for SMV 3000 Multivariable Configuration (MC) Data Sheets

These variables can be accessed by holding the UP button for 5 seconds.

FlashCO2, CO2 at 23 $/ton

ERTC PETROCHEMICAL Conference 20 st -22 nd February 2002, Amsterdam, The Netherlands

Schedule of Requirements THERMODYNAMICS LABORATORY- CHEMICAL ENGINEERING DEPARTMENT

Transcription:

Workshop Objectives Workshop 302-compressor-anti-surge Illustrate how to create a simple anti-surge control on a compressor Workshop Description Flowsheeet: A feed stream at 1 bar with methane, ethane and propane is compressed to 2 bar. Step 1 Open the file compr3.bkp in Aspen Plus. Run the simulation Export as pressure driven. Notes about the simulation D101 is the knockout drum, to prevent any liquid to enter the compressor. Note that at the initial conditions there are no liquid, which is causing some warnings during the export. The valve FV105 is specified with a valve coefficient, to allow the export. The volume of the D101 including the volume of piping for the lowpressure side of the compressor. K101 is the compressor, specified with a performance curve giving the head as a function of flowrate, and efficiency as a function of flowrate. The compressor is specified as dynamic, i.e., we give the moment of inertia. In the dynamic simulation, the speed will be free, and the mechanical power will be fixed. A controller will be added to manipulate the power and control the speed.

E101 is a cooler. It is specified with constant medium temperature, as to mimic an air cooler. (Avoid the constant duty option, unless you add a temperature controller, as the flowrate may vary dramatically) L101 and DP101 represent the volume and pressure drop of the piping on the high-pressure side. ZV101 and ZV107 are the isolation valves. M-DOWN and V-DOWN represent the volume and pressure drop of the process downstream. Finally, FV1-3 is the recycle valve, which will be used to prevent the compressor to go into surge. Step 2 Open the file in Aspen Dynamics. Change the run mode to initialization. Do a run. Note: It is difficult to trace the source of this type of error. One can look in the group demonstration as the message above is triggered by equations from group 104 to 118. It is actually the group 118: Having found the equation, one would then have to know why this is causing a flash error: the saturation pressure is needed for chocking and cavitation calculations. pvap_pressure is the procedure that returns the saturation pressure for given temperature and composition. As the temperature is above the critical point, there is no saturation pressure, hence the problem. The solution is to avoid chocking and cavitation calculation, which is done by switching the valve in Simple mode. Step 3 Open the Configure form for the valve FV105. Change the presmode to Simple. Step 4 As the time constants in the process are very short, we will change the units for time to minutes, instead of hours Open the Run Options window. Change the units of time to Minutes for both model and plot. Open the Global table. Change the parameter GlobalTimeScaler to 60 (this means 60 seconds in one minute). Run the simulation in Initialization run mode.

Step 5 (1) Specify the control system. Remove the controller PC2 and the connected control signal. Remove the controller PC3 and the connected control signals. Create a PID block, name it speed_control. Connect as PV the compressor speed (ActShaftSpeed) Connect as OP the compressor power (Bpower). Open the Configure form for the PID. - Click on the Initialize Values button and set as follows: 1. Gain = 4 2. Integral time = 0.5 min 3. Controller action = Reverse Create a PID controller, name it FC. Connect as PV the compressor approach to surge (perf_curve(1).avgsrg) Connect as OP the valve FV103 position (Pos). Open the Configure form for the PID. - Click on the Initialize Values button and set as follows: 1. Set point = 15% 2. Bias = 1 3. Gain = 1 4. Integra time = 60000 min 5. Controller action = Reverse On the Range sheet, set the following: - Process variable range minimum = 10 - Process variable range maximum = 20 - Output variable range minimum = 1e-4 - Output variable range maximum = 100

Step 6 Valves typically have a short time constant. However, the time contant may be important to consider for this type of study. Restart the simulation. Create a Lag_1 block. Reconnect the signal the output of the Lag_1 block to the valve position. Open the Configure form for the Lag_1 block and set the time constant to 5 seconds. Restart the run. If you close the valve ZV107 faster (i.e., in 6 seconds or 0.1 minute), you will observe that with a time constant of 5 seconds, the compressor goes into surge. The simulation will then fail to converge. Dynamic Simulation We want to know recycle stream flowrate to prevent surge circumstance when the feed flowrate abruptly is reduced due to the sudden close of ZV 101 valve. Initialize the dynamic run. Do a dynamic simulation during 2 minutes. Change the ZV 101 valve opening percent to 10% from full open. Note: Assumptions used in Aspen Dynamics compressor model are not meant to be valid in the surge region.

Fig: Feed stream flow valve out stream flowrate change when the valve opening percent abruptly is changed to 10%. Fig: Compressor speed-controller control action change versus time

Fig: Recycle stream flowrate change which prevent compressor from surge when the valve opening percent abruptly is changed to 10%. Fig: Outlet stream flow valve out stream flowrate change when the valve opening percent abruptly is changed to 10%.