Operation & Maintenance instructions for the Söll Vi-Go type fall protection system with guided type fall arrester

Similar documents
Operation & Maintenance instructions. for the Söll Vi-Go type fall arrest system with guided type fall arrester

Assembly, Installation and operating. instructions for. Söll-Xenon anchorage device

Usage and maintenance manual for the fall arrester system of the Söll GlideLoc type with a guided type fall arrester. Söll Comfort 2. Order No.

Manual for the. Installation. Use and Maintenance. "Söll-GlideLoc" fall arrest system. Ho-Ver turn table

Instructions for use / test book

Manual. for the Installation, Use and Maintenance. Söll-GlideLoc fall arrest system. Rotary-Exit-Section

Instruction Manual AC350 GUIDED-TYPE FALL ARRESTER ON RIGID ANCHORAGE LINE EN 353-1:2002

Operating manual for descender and rescue lifting devicesafescape

Söll MultiRail Aluminium horizontal anchor device system

User Instruction Manual Fixed Beam Anchor

Manual. for Installation. and Maintenance. of Vertical Guide-Rails. Söll-GlideLoc fall arrest system

SpanSet Gotcha CRD User Instructions. SpanSet Certified Safety

Installation, Operating, Inspection and Maintenance Instructions Ladder Climber s Safety System. Warning

User Instruction Manual Fixed Beam Anchor

User Instructions 1789 Parapet Wall Anchor

Operating instructions. Skyline Beam Clamp

Söll GlideLoc vertical rail system

PHOENIX, ARIZONA USA

Operating manual Mobile Man Anchor IM-200 Reference No. IM 200

ATOM-X 2. User Manual

LAD-SAF LAD-SAF VERTICAL SAFETY SYSTEM THE ULTIMATE IN FALL PROTECTION

GM-121: Container End Lock Anchor Wand Page 1 WINSAFE CORP. GM 121 CONTAINER END LOCK ANCHOR WAND OPERATING INSTRUCTIONS AND MAINTENANCE

Product Numbers & Ordering Information

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

User Manual 1792 Standing Seam Metal Roof Retractable Swivel Anchor

1.2 LIMITATIONS: Consider the following application limitations before using this equipment:

GOTCHA CRD. Rescue, hoisting and abseiling equipment EN341 / EN1496 CE0158 TECHNICAL DATA

Figure 1 - Parts Identification. Copyright 2002, DB Industries, Inc.

USER MANUAL Do not throw away these instructions. Read and understand these instructions prior to use of the Lad Grab Safety System.

AVANTI ANCHOR SAFETY POINT User s, Maintenance and Installation Manual

Installation & User Manual

Figure 1 - Cable Grip Horizontal Lifeline Termination ZORBIT ENERGY ABSORBER RELEASE TAB

??????? is committed to providing a safe work environment for its employees and preventing occupational injuries due to falls.

User Instructions 1790 Rail Anchor

User Instruction Manual. Fixed Beam Anchor

MSA Latchways Ladder System

KRATOS - HARNESS INSTRUCTIONS

1.3 LIMITATIONS: The following application limitations must be recognized and considered before using this product:

User Instruction Manual

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

Operating instructions. Bolt-on Bar Joist Anchorage

RESCUE LIFTING DEVICE RUP 503-[...] AT 053-[...] xx

Installation Drawings & Instructions Fall Protection Systems

H-50.2 Fall Arrest System EN 353-1:2014

BRAKE WINCH RUP 503-[T/BT] EQUIPMENT FOR LIFTING LOADS. AT 053-[T/BT] xx

IMPORTANT: Record the product identification information from the ID label in the inspection and maintenance log in section 9.0 of this manual.

INSTRUCTIONS FOR USE

Figure 1 - Parts Identification

Height Safety Lifting Load Control Safety Management GOTCHA Rescue Range TECHNICAL DATA

Compliance Is the First Step on the Safety Ladder Understanding the final walking-working surface rule from OSHA and how Honeywell ladder solutions

Product Name: 2-Way Standing Seam Roof Clamp

Operations and Instruction Manual Might Swivel Model # Concrete and Steel Anchorage Connector ANSI Z ,000 lbs / 44kn

AS/NZS 1801 USE AND CARE BOOKLET OCCUPATIONAL PROTECTIVE HELMET

Reliance Industries, LLC Operating instructions for the / Bolt-on D-Ring Anchorage. Model # 3071

ROOF ANCHOR / D-RING ANCHOR PLATE

Table of Contents Beam Trolley

Vertical Lifeline. Ladder Climb. User Instructions. 3M Occupational Health and Environmental Safety. Fall Protection Equipment

SUPER SLIDER BEAM ANCHOR ADJUSTABLE FROM Model # BWA030N

Personal Protective Equipment

11.4 FALL-ARREST SYSTEM AND EQUIPMENT CHECKLIST (Must answer yes to all applicable questions)

OWNER'S MANUAL. Turnbuckle. Stanchions. Warning

HELM Hinging facility according to EN 795:2012 Typ D. Sliding hardware

Fall Protection Checklist. Guardrail System

XTS-Impact. XTS-Terminal (hold)

SECURITY AND CONFIDENCE AT HEIGHT

Fall Control User Instructions

H-50 Fall Arrest System EN 353-1:2014

Instructions for assembly and use ZAP telescopic platform ladder Z600

IMPORTANT: If you have questions on the use, care, or suitability of this equipment for your application, contact DBI/SALA.

3-WAY FALL ARREST AND RECOVERY SRL USER MANUAL

Product Name: 2-Way Standing Seam Roof Clamp. Instruction Manual. Part #: 10600

Technical Briefing Note

Personal Fall Arrest System. User s. Manual. Part Number January 2014 (Replaces July 2013)

You may order this publication from WCB Publications and Videos, Please quote ordering number BK60.

ROLLGLISS TOP/R350. Safety and rescue system. Operating and Maintenance Instructions

GM-120: Container Top Lock Anchor Wand Page 1 WINSAFE CORP. GM 120 CONTAINER TOP LOCK ANCHOR WAND OPERATING INSTRUCTIONS AND MAINTENANCE

Product Name: Bull Ring Anchor

FAILURE TO COMPLY WITH THE MANUFACTURER S INSTRUCTIONS CAN LEAD TO SERIOUS INJURY OR DEATH OF THE PASSENGER/RIDER!

Instructions for the following series products:

Know Your ABCs FALL PROTECTION GUIDE

Rescue Slider - RS02. User & Installation Manual

Product Name: Beamer Trolley Anchor

LOAD-BEARING SHEETS SAFETY ANCHOR SA

Operator's Manual Supplement

FIXED LADDERS ALO 60 & ALO 72

Safewaze FS983 Cable Safety Climb System Ladder Mount Instructions

P+P Retractable Type Fall Arrester PK6S

PERSONAL FALL PROTECTION

PF30 Inspection & Maintenance Manual

INSTALLATION AND USAGE HANDBOOK

GEMTOR. ... when your life is on the line OWNER'S MANUAL. FLW Series Self-Retracting Lanyard/Fall Limiter

Product Name: Hold Me Rope Anchor

DREW UNIVERSITY FALL PROTECTION PROCEDURE (DRAFT 12/11)

VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # VBC014N

Product Name: O-Torque Beamer

Rope Grab Operation & Maintenance Manual

INSTRUCTIONS FOR USE

Security and confidence at height.

CLIMA Vertical Line Instructions

Product Name: Concrete Anchor Strap

Transcription:

Operation & Maintenance instructions for the Söll Vi-Go type fall protection system with guided type fall arrester Söll Vi-Go is personal protective equipment against falls from a height: Guided type fall arrester including a rigid anchor line, that complies with EN 353 - Part 1:2002 Serial number: Year of manufacture: (Initial testing had been done by the manufacturer. Therefore a handwritten approval is not necessary.) (The following must be completed by the operator in permanent waterproof ink.) Date of initial operation: Operator/ user: Street: Place: Phone: Fax: Date of Issue: 04.02.2014 SE 70 Technical modifications reserved!

Contents A Safety precautions 4 B Installation 6 C Use 10 D Anchor device platform support 14 E Maintenance 17 F Regular inspections and repairs 21 G Checklist for acceptance 22 These instructions are protected by copyright! They may not be reproduced and distributed in any ways/ by any means without prior written consent of the author according to Articles 16 and 17 of the German Copyright Act. HONEYWELL FALL PROTECTION Deutschland GmbH & Co. KG will prosecute any violations against this under Article 106 of the German Copyright Act. Notice! In this issue the following has been changed: Fig. D3, E5, Fig. E3 page 2 of 24 www.honeywellsafety.com

Explanations of symbols Danger! Improper or careless handling could cause accidents leading to falls or even death. Warning! Non-observance could result in serious injury. Important! Useful information and user tips are given here. General information These installation and usage instructions are applicable for the safety-related components of the product. The delivered product can differ from the version described here due to accessories that may be added to the product. www.honeywellsafety.com page 3 of 24

A Safety precautions A1. Anyone working with or on the Söll Vi-Go fall protection system must be familiarized with these instructions prior to using the system. Use which is not in accordance with these instructions constitutes a risk to human life. Operatives must be given training covering these instructions and the user information before starting work and at regular intervals thereafter, but at least once a year. A2. The operator of the Vi-Go fall protection system as well as the user of the fall arrester must properly ensure that this manual is always stored in a dry place together with the appropriate fall arrester and is available for consultation at all times. A3. The operating company must present this instruction manual at the request of the manufacturer (HONEYWELL FALL PROTECTION Deutschland GmbH & Co. KG or one of its authorized dealers). A4. National regulations on accident prevention and use of safety equipment for construction work must be adhered to. A5. The guided type fall arrester that comes with the Söll Vi-Go system is an integral part of the safe-climbing system in compliance with EN 353-1 and is designed for use as personal safety equipment. To ensure proper use of the Söll fall protection system, the operator must ensure that the full body harness and the fall arrester are used according to these instructions. After use, the fall arrester must not be left connected to the safe climbing system. The fall arrester that comes with the Vi-Go system must be operated only in original Söll Vi-Go safe climbing systems. Use with systems from other manufacturers can interfere with the function of the fall arrester. In such cases, Honeywell Fall Protection Deutschland GmbH & Co. KG and its authorized dealers do not assume liability for the product. As a result, the complete liability is transferred to the operator. A6. The safe climbing system must be used only in conjunction with full body harnesses that have been checked and approved in accordance with EN 361 and are equipped with a front attachment point. A7. The conjunction between fall arrestor and full body harness is effected through connecting the karabiner hook of the fall arrester with a certified anchorage ring (marked with A ) at the front of the full body harness. The distance between the fall arrester and fully body harness must not be minimized and enlarged (e.g. by adding or removing a connector). A8. A maximum of eight users may simultaneously protect themselves against falling from a height using the Vi-Go safe climbing system. The distance between the users must not be less than3,0 m. The actual number of users depends on the load-bearing capacity of the base structure. Maximum 4 persons can use the Vi-Go fall protection system with platform support. If the Vi-Go platform support is used as anchor device maximal 2 persons are allowed. page 4 of 24 www.honeywellsafety.com

A9. The minimal and maximal load of the user is 50 and 140 kg. The maximal load of the user (incl. clothes & equipment) must not be exceeded. A10. The guided type fall arrester that comes with the Vi-Go system must always be directly attached to the front attachment point of the full body harness. A11. To ensure the safety of the user in case of a fall, fall arrester must not be used by hand but it has to move freely on the guided type fall arrester. A12. The fall arrester should always be handled in a manner that will protect it from damage or corrosion. A13. The fixation-points for the cable of the Vi-Go system must not be used for securing loads. A14. Before and during the use of the installed fall protection system, the system must be visibly inspected to ensure that it is operating properly. A15. The operator of the safe climbing system must ensure that a rescue measures plan is available that takes into account all possible emergencies that may occur when working. A16. Working temperature 40 C to +100 C; here, ensure that the system is free of grease, oil and ice. A17. The operator must be in good health and must not be under the influence of alcohol, drugs or medicines. A18. In case of the use of further personal protective equipment, relevant instructions must be followed. A19. The check list (see Section G) must be fully and correctly compiled by the senior engineer of the installing company using of an indelible pen. A20. With a weight of 100 kg and fall factor 2 situation (worst-case scenario) the height required under the feet of the user is at least 2 m. A21. Note The user may be not be sufficiently protected against hitting the ground or obstacles if at a height of less than 2 m. A22. Important! Before using the safe-climbing system, ensure that there is the required free space of 2.0 m under the user s feet. A23. The system has been tested and approved by the testing institute 0158: DEKRA EXAM GmbH Dinnendahlstraße 9 44809 Bochum www.honeywellsafety.com page 5 of 24

B Installation B1. Important Before installation, check whether the component on which the Söll Vi-Go system is to be fixed is capable of withstanding loads resulting from a fall (certificate for stability). A qualified engineer must certify this. The maximum length of the cable may not exceed 200 m. The following characteristic loads form the basis of the certificate of stability: loads resulting from dynamic loads due to fall, user loads and the individual weight of the system components. For fastening the upper end of the cable, acting vertically downward: number of simultaneous users Characteristic vertical load Fc1 [kn] 2 9,0 3 10,0 4 11,0 5 12,0 6 13,0 7 14,0 8 15,0 For fastening the intermediate bracket and the lower end of the cable, independent of the number of users, effective in each direction: Fc2 = 1.5 kn page 6 of 24 www.honeywellsafety.com

Fig. B1 1. Guided type fall arrester (24836 / 1017271) (24837/ 1017681) 2. Cable tensioner (24798 / 1017380) (24799 / 1017381) 3. Steel cable 4. Universal beam bracket (24815 / 1017382) (24814 / 1017383) 5. Rung clamp (24807 / 1017384) (24806 / 1017385) 6. Manual intermediate (24838 / 1017370) (24839 / 1017373) 7. Automatic intermediate (24840 / 1017375) 8.Cable end piece B2. Warning! The cable end attachments must always be fastened to suitablysized substructures. B3. The upper cable anchor point most always be above the user. B4. Warning! The cable must be sufficiently tensioned. The tension reading on the cable tensioner must be between the minimum and the maximum marking. B5. The maximum distance between two intermediate brackets is 10 meter. The intermediate brackets reduce and limit the deflections of the steel cable. The deflection of the system depends on the total length and the wind speed. The intermediates must avoid that the cable is touching the construction and can get damaged. For longer systems and in regions with high wind speed, we recommend shorter distances between the intermediate brackets. - Systems length up to 55 m, 4 m between the intermediate brackets. - Systems length more than 55 m, 3 m between the intermediate brackets. - If the wind speed is more than 130 km/h, 3 m between the intermediate brackets. www.honeywellsafety.com page 7 of 24

These are recommendations. If it is secured, that the cable will not touch the steel structure, the maximum distance between the intermediates can be used. B6. At least the following components must be used when installing the Söll Vi-Go system: 1. Cable tensioner (2) 2. Cable 7 x 19 (8 mm / 10 mm / 3/8 ) (3) B7. Installing the Söll Vi-Go system: 1. Fasten the steel Cable (3) at the upper attachment point. 2. Install the cable tensioner (2) at the lower attachment point. Fig. B2 A: Tensioning element B: Tension reading C: Rope attachment point D: Lock nuts 3. Hang the cable (3) at the cable attachment point (C) of the cable tensioner (2). 4. Turn the tensioning element (A) counter clockwise until the tension reading (B) is between the minimum and the maximum marking. At 500 N the cable is sufficiently pre-tensioned. 5. Secure the tensioning element (A) against twisting using the two locking nuts (D). B8. Note The cable of the Vi-Go system must be pre-tensioned to ensure the correct functioning of the shuttle. The required pre-tension is 500 N (+/- 100 N). page 8 of 24 www.honeywellsafety.com

B9. For installation of the swageless terminal cable end part an acid free gasket material e.g. Silkaflex 221 should be used. It has to be put in the body of the cable end part. Therefore the swageless end terminal has to be screwed on and the gasket material has to be put in the clamp jaw body and also in the gaps of the clamp jaws. After that the swageless end terminal has to be screwed together. This act has to be retried till the gasket material discharge out of the opening where the rope has to be inserted. Then the swageless end terminal has to be cleaned. The clamp jaws must not use again. www.honeywellsafety.com page 9 of 24

C Use C1. Important! Inspection before climbing: Before each use, inspect the cable, the cable tension, the fall arrester, the intermediate fixings and the karabiners for usability. The fall arrest system must not be used if defects have been noted or in case of doubts as to its proper function. Before further use an inspection by a competent person is needed or the defective parts have to be replaced. Before and during use it should be planned how to effect a rescue safely and effectively. C2. Each user must secure themselves to a separate fall arrester. C3. The fall arrester, properly used in connection with a full body harness, protects its user during ascent and descent against falls. C4. When working in or next to the ascent route and during jobs and actions that are not a part of the usual ascent and descent movements, the climber must additionally secure themselves with a lanyard in accordance with EN 354 or a lanyard for safety harness in accordance with EN 358. (Securing with an anchor device). This is also applicable for idle positions that are intended to be a break on the fall arrest ladder. Only suitable anchor devices must be used for this. In all these situations, the lanyard must be held tight in order to prevent a fall. C5. Important! A fall arrester according to EN 353-1 shall be used only by persons who: have been trained or are otherwise competent are supervised directly by a trained or competent person. C6. Connection to the system: The guided type fall arrester that comes with the Söll Vi-Go system is a cable -guided fall arrester with an integrated shock absorber, which permits use without opening the fall protection system. The unique design allows one-handed fixing on an 8 mm, 10 mm or 3/8" strong steel cable. The fall arrester has an anti-inversion mechanism, which prevents the fall arrester from being incorrectly attached to the cable. page 10 of 24 www.honeywellsafety.com

C7. Connecting the fall arrester to the full body harness: 1. Pull-down the knurled bushing (4.1) of the karabiner. 2. Then turn the knurled bushing and press it inwards. 3. Attach it directly in the attachment point of the full body harness. 4. Release the knurled bushing, it locks automatically. Fig. C1 front D-ring of harness harness C8. Danger! An unsecured karabiner (open knurled bushing) is dangerous to human life. C9. The abdominal or thoracic strap of the full body harness must fit the body tightly (see Fig. C1). Fig. C2 correct body incorrect Fall arrester D-ring attachment element attachment element C10. Danger! The karabiner of the fall arrester must be directly inserted into the front attachment point of the full body harness. The length of the intermediate joint (length between the cable and the inner curve of the eye on the harness) must not exceed 200 mm. www.honeywellsafety.com page 11 of 24

C11. Inserting in the guiding cable: Fig. C3 1: Lock knob 2: Slider 3: Latch Fig. C4 1. Press the lock knob (1). 2. With the lock knob pressed (2) push slider 2 into the casing. 3. Through the now-open gap in the casing of the shuttle, place the shuttle on the cable such that the arrow on the casing points upward. 4. Release the slider (2) and the lock knob (1). 5. The shuttle for the Vi-Go system is now connected to the guide cable. 6. Check whether the shuttle can freely slide vertically on the guide cable. 7. Check the functioning of the locking and catch mechanism by moving the latch (3). page 12 of 24 www.honeywellsafety.com

C12. Danger! Fall protection must be ensured in another way before removing the fall arrester from the guide cable Removing from the guide cable: 1. Press the lock knob (1). 2. Press the lock knob (1) and push slider (2) into the casing. 3. Through the now-open gap in the casing of the shuttle, remove the shuttle. 4. Release the slider (2) and the lock knob (1). www.honeywellsafety.com page 13 of 24

D Anchor device Extension post D1. The Söll Vi-Go extension post is a certified anchor point for fall protection for 2 persons in accordance to EN 795. The eye of the anchor steel plate (pos. 1) serves as anchor point. Therefore is it possible when you are changing from vertical to horizontal to protect you against falling. Fig. D1 page 14 of 24 www.honeywellsafety.com

D2. The characteristic load affecting the extension post must not exceed 22 kn under any circumstances. D3. At working in falling off dangerous areas it has to pay attention to the safe standing of the user. Tripping points in the entrance and working area have to be avoided. D4. Functional capability of the system has to be inspected visually before and while using.the installed fall protection system. D5. Warning! The anchor device must not used anymore if the anchor eye was charged by a fall. In this case the anchor device has to be checked by a competent person and if necessary changed. D6. The anchor device Söll Vi-Go extension post may only be used in combination with the following safety equipment: - at working with falling hazard fall arrest system in accordance to EN 363 and energy absorber EN 355 - rescue systems in accordance to EN 1496, 1479 and 1498 D7. The system of the personal protective equipment against falling (only with energy absorber) or rescue system has to be chosen that a collision of the user with the ground or collision with other bars can be avoided. For that the information for use of the manufacturer has to be checked. D8. In order to secure against fall from a height the karabiner hook (pos. 1) of the lanyard has to be installed on the eye of the anchor steel plate (pos. 2) and locked to avoid unintended disconnecting. Fig. D2 D9. Danger! The karabiner hook of the lanyard must not disconnect from the anchor device before the user is protect by another solution against a fall. www.honeywellsafety.com page 15 of 24

D10. Labeling of the anchor device: - Manufacturer of the anchor device - Identification of the type - European standard EN 795:1996 - Pictogram with an advice that the user has to read the instruction for use - Maximal allowed load - Maximal number of users - The anchor device may only used with PPE in accordance to EN 355 or 360 Fig. D3 page 16 of 24 www.honeywellsafety.com

E Maintenance E1. A fall arrester which has arrested a person's fall from a height must not be used again until a competent person has agreed on its further use. If no competent person is available, the fall arrester must be returned to the manufacturer or authorized dealer for inspection together with these instructions. E2. Depending on use requirements and operational conditions, the fall arrester must be inspected by a competent person for unimpaired condition to ensure it is in perfect working condition as required, but at least once a year. For reasons of safety the fall arrester may only be repaired by the manufacturer. Competent person is a: person who due to his training and experience in the field of personal protective equipment against falls from height has sufficient knowledge about applicable state and local safety regulations, applicable standards (e.g. EN-standards) and is thus capable and thus authorized by Söll of judging the correct status and use of systems and products against falls from height. E3. Warning! The gap between the slider (2) and the shuttle casing must not be more than 6 mm. If this value is exceeded, the fall arrester must be sent back to the manufacturer for revision. Fig. E1 www.honeywellsafety.com page 17 of 24

E4. Labeling of the fall arrester: Söll Vi-Go - type denomination of the guided type fall arrester EN 353-1:2002 - European standard issued 2002 Use only with Ø 8mm, 10mm - Information about permitted cables or 3/8 approved cable V JJ - Product code - construction year 0001 - serial number CE0158 - monitoring testing institute DEKRA Exam Arrow - advice to read the maintenance - direction for usage/ climbing Fig. E2 page 18 of 24 www.honeywellsafety.com

E5. Labeling of the system: Söll Vi-Go - type designation of the system EN 353-1:2002 - European standard issued 2002 CE0158 - monitoring testing institute DEKRA EXAM - Pictogram advising to read the instructions Fig. E3 - Pictogram advising to wear fall protection equipment To be filled by the installer: - date of installation - maximum number of users - installation number E6. The guided type fall arrester that comes with the Söll Vi-Go system should be washed with water and must be dried using a cloth. Do not wash it with a quick cleaner, thinner or degreaser containing trichloroethane. Do not use grease. E7. The guided type fall arrester that comes with the Söll Vi-Go system should be clean and as dry and dust-free as possible, and should be stored in a cool place. www.honeywellsafety.com page 19 of 24

Further Remarks: page 20 of 24 www.honeywellsafety.com

F Regular inspections and repairs Year of manufacture: Date of purchase: Serial number: Date when used the first time: Date Reason for working on the system Damage determined, repairs carried out and other important details Name and signature of the expert Date of the next regular inspection www.honeywellsafety.com page 21 of 24

G Checklist for acceptance Fall protection system type Söll Vi-Go acc. EN 353-Teil 1:2002 Both sides of this check list must be filled in by the site manager of the installation company, using an indelible pen. The installation company site manager is responsible for the accuracy of the statements. If a checkpoint is answered with no, the same must be explained in the Space for comments list on page 22. Control activity The fall arrester has been checked for perfect functioning. Remarks (please cross) yes no The gap of the fall arrester is within the permissible range (see Fig. D1) The upper cable anchor point is always above the person to be secured. All screws on the Vi-Go system have been tightened firmly. All screws of the ladder are firm. All fasteners on the ladder have been tightened firmly. Only anti-corrosive bolt connections have been used. The cable is sufficiently pre-tensioned. (see the cable tensioner) Identification label in place A test run has been carried out. These instruction have been handed over to the operator. Only HONEYWELL FALL PROTECTION Deutschland GmbH & Co. KG fall arrest technology components have been used. page 1/2 page 22 of 24 www.honeywellsafety.com

Object: Operator: Street: Town/Code: Phone: Fax: Installer: Street: Town/Code: Phone: Fax: Handed over to: Operating company or its representative) Name Signature Site manager oft he installation company: Name Signature Location: Date: Next verification on: in 1year Defects, irregularities and deviations from the checklist must be entered here. Space for comments Expert Signature Date page 2/2 www.honeywellsafety.com page 23 of 24

Honeywell Fall Protection Deutschland GmbH & Co. KG Seligenweg 10 D-95028 Hof SE 70 +49 (0) 9281 83 02 0 February 2014 +49 (0) 9281 36 26 2014 Honeywell International Inc. page 24 of 24 www.honeywellsafety.com