Online DGA-monitoring of power transformers

Similar documents
A Revised Framework for the Transformer DGA Guide

MODERN APPROACH FOR CONDITION MONITORING OF POWER TRANSFORMERS USING DISSOLVED GAS ANALYSIS

Understanding Dissolved Gas Analysis (DGA) Techniques and Interpretations

A REVIEW OF DISSOLVED GAS ANALYSIS AND TRANSFORMER HEALTH CONDITION

DISSOLVED GAS ANALYSIS OF NATURAL ESTER FLUIDS UNDER ELECTRICAL AND THERMAL STRESS

TRANSFORMER SERVICE. Dissolved gas analysis and oil condition testing

Comparison of Different DGA (Dissolved Gas Analysis) Methods for the Condition Assessment of Power Transformers

Categorizing Faults via DGA. GE Grid Solutions M&D

Since the beginning of production of oil for transformers

Dissolved Gas Analysis An Early Identification of Faults in High Voltage Power Equipment using MATLAB GUI

Dissolved Gas Analysis - Past, Present and Future

Improved Monitoring of Dissolved Transformer Gases on the Basis of a Natural Internal Standard (NIS)

DGA Tools: Duval Triangles and Pentagons

Power Transformer Maintenance. Maintenance Practices & Procedures for Substation Class Distribution Power Transformers

Mathieu Guertin. Morgan Schaffer Inc. Canada. Director Europe, Russia and Africa. A cost effective strategy for smart grid technology adoption

Dynamic Behaviour of Fault Gases and Online Gas Sensors. Germany

Transformer fault diagnosis using Dissolved Gas Analysis technology and Bayesian networks

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

DISSOLVED GAS ANALYSIS OF POWER TRANSFORMERS

EXPERIENCES WITH APPLICATION, DIAGNOSTIC VALUE AND IMPACT ON ASSET MANAGEMENT OF INSULATION OIL ANALYSIS

SF 6 Product Guide. Gas Analysis Instruments and Accessories

Advanced Test Equipment Rentals ATEC (2832) OMS 600

Research Article. Fault diagnosis of power transformer based on chemical properties of insulation oil

Nandkumar Wagh, D.M. Deshpande

Online Publication Date: 19 January, 2012 Publisher: Asian Economic and Social Society

INTERNATIONAL STANDARD

Neil Kane Managing Director EMT UK

* Analysis of TCG ( Total Combustible Gas ) and 6 kinds of Gases * High Sensitivity for C 2

Draft Guide for the Interpretation of Gases in Oil Immersed Transformers

Real-time Analysis of Industrial Gases with Online Near- Infrared Spectroscopy

Alphasense Application Note AAN NDIR: Gas Concentration Calculation Overview

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Columbus Instruments

Diagnostics of HV bushings through oil sampling and analysis. Experience with GSU transformers

ASTM 3612/TOGA/Dissolved Gas GC Revised October 2013

Laser Spectrometers for Online Moisture Measurement in Natural Gas. Ken Soleyn GE M&C

TRANSFORMER RELIABILITY AND DISSOLVED-GAS ANALYSIS. Delta-X Research Inc, Victoria BC, and 2 IREQ, Varennes QC CANADA

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Instruments for Measurement of Dissolved CO 2 and O 2 in Beverages

Session Number: 3 High Voltage Power Transformer Dissolved Gas Analysis, Measurement and Interpretation Techniques

HIGH ACCURACY MULTI-GAS MONITORING USING AUTOMATED SELF- CALIBRATION

Ultima. X Series Gas Monitor

Describe Flammable Gas Measurement

Dr. Thiedig DIGOX 5 CO 2. In-line measurement of CO 2 for constant product quality. Anlagen- und Analysentechnik

EasyLine Continuous Gas Analyzers. So smart, they re simple

AUK Environmental Sensor. Determining the refractive index of the air. AUK Environmental Sensor

A New Approach for Transformer Incipient Fault Diagnosis Based on Dissolved Gas Analysis (DGA)

Applications Note: Use of "pentane equivalent" calibration gas mixtures

Level MEASUREMENT 1/2016

Protective Atmospheres, Measurement Technologies and Troubleshooting Tools

On-Stream Tightness Testing of Vacuum Process Installations

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

" High Voltage Switch Yards & How Safe are these really" <Peter Rhodes> <Principal and High Voltage Solution. Com Ltd>

CALCULATING THE SPEED OF SOUND IN NATURAL GAS USING AGA REPORT NO Walnut Lake Rd th Street Houston TX Garner, IA 50438

Applications of a Magnetic Sector Process Mass Spectrometer to the Analysis of Variable Vacuum Samples

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

What I have learned about SF 6 gas testing.a Practical explanation

The Role of Gas Monitoring in the Prevention and Treatment of Mine Fires

Power Transformer Fault Diagnosis Based on Dissolved Gas Analysis Using a Fuzzy Neural Network Approach in a Real Data Base

The Helium Leak Detector

HCL MONITORING. ICAC MARAMA WORKSHOP May 18-19th, Presented by: Ty Smith. CEMTEK

Improve Reliability of Turbomachinery Lubrication and Sealing Systems

Flammability Chart. Gas Formula Ignition

Degassing ERC KK Saitama, Japan

ENVIRONMENTAL AND POLLUTANTS GAS ANALYZERS

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

Simple, Robust, Reliable Measures ph Doses either acid (lower) or alkali (raise) Displays ph, Total Dose Count (DCT) and Dose Count per hour (DC/h)

Oxygen Measurement in Natural Gas

GasSense NDIR User Manual

Pressure Sensitive Paint (PSP) / Temperature Sensitive Paint (TSP) Part 1

Experiment 18 Properties of Gases

It is essential that the maintenance staff is qualified for electrical works and follows safety procedures.

LUMAZOTE T ECHNICAL BRO CHU RE

PROPOSAL FOR AN IMPROVEMENT IN TRANSFORMER DIAGNOSIS BY DGA USING EXPERT SYSTEM.

Condition Monitoring of Power Transformer Using Dissolved Gas Analysis of Mineral Oil: A Review

IRwin Methane Leak Detector. Innovation makes the difference

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

DSC 204 HP Phoenix. High-Pressure Differential Scanning Calorimetry up to 15 MPa Method, Technique and Applications

COAL MINES TECHNICAL SERVICES, GAS DETECTION RELATED SERVICES FOR MINES RESCUE

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Dissolved Oxygen and measurement possibilities. Berno Lüpkes, 15 th March 2017

SUBSTATION MAINTENANCE ELECTRICAL OPERATING PROCEDURE

Low gas volume & flow measurements made easier Gas Endeavour

The FLUX-METER: implementation of a portable integrated instrumentation for the measurement of CO 2 and CH 4 diffuse flux from landfill soil cover.

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

Applied Technology and Best Practices in CEE. Conference

FOURIER TRANSFORM INFRARED SPECTROSCOPY

S on equipment and pipelines along with the constant threat to personnel safety justify major investment in H 2

acrolein, acetaldehyde and acetone( cm -1 ); methanol (1306 cm -1 ); ethylene (949 cm -1 ); and isoprene (893 cm -1 ).

CALIBRATION. empanelled laboratories following standard procedures and using certified reference standards.

FCTechnik. flox[control] Gas Control Units for Aluminium Production. for aluminium production flox[control] flox[on] FC Technik 1

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

Calibration and Bump Test Requirements for Direct Reading Portable Gas Monitors

Manual of SF6 Comprehensive Tester

Acoustic Pulse Reflectometry Brings an End to Tube Inspection Sampling By Dr. Noam Amir, Chief Technology Officer, AcousticEye

Level, Pressure, and Density Instrumentation for the Petrochemical Industry

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Transcription:

Online DGA-monitoring of power transformers Senior Industry Expert, Vaisala Finland Member of CIGRE A2/D1.47 and D1.52 WGs April 2018 Vaisala

Webinar content 1. Dissolved gases why and which gases 2. Fault types 3. Online monitoring why 4. Things to consider when choosing a monitor 5. IR technology in online DGA Vaisala Optimus DGA monitor 6. How to define limit values and interpret the data 7. How to utilize the online data examples 8. Comparing online data to laboratory results 2018-04-03 Vaisala 2

Dissolved Gas Analysis DGA is a comprehensive transformer condition assessment tool It can detect multiple fault types inside a transformer. 2018-04-03 Vaisala 3

Why gases form in a transformer? Chemical reactions happen when conditions favor them e.g. in presence of fuel, oxygen, heat and catalysts. In case of a fault, temperature increase at fault location. WHY GASES: oil and/or paper decomposition due to thermal stresses gases form WHICH GASES : Type and amount of gases depends on occurring fault and its energy intensity and area. More intensive faults give higher gas production rate. Larger fault area give higher gas production rate. Paper Oil Heat Copper Uncontrolled chemical reactor 2018-04-03 Vaisala 4

Which gases? 7 formed gases are commonly considered as key fault gases. Mathane, ethane, ethylene, acetylene, carbon monoxide, carbon dioxide and hydrogen (CH 4, C 2 H 6, C 2 H 4, C 2 H 2, CO, CO 2 and H 2) Which gases form depends on temperature at fault location materials in contact with the fault area 2018-04-03 Vaisala 5

Fault types PD partial discharge T1 thermal fault <300 C T2 thermal fault 300-700 C T3 thermal fault >700 C D1 Low energy discharge (sparking) D2 High energy discharge (arching) S Stray gassing of oil < 200 C O Overheating < 250 C C Carbonization of paper > 300 C Most severe thermal faults when also paper is involved! 2018-04-03 Vaisala 6

Why online monitoring Vaisala

Why online DGA monitoring? 1. Online monitoring detects faults at their early phase Enables corrective actions before severe transformer failure. Cost reduction in maintenance and repair Avoid consequential costs of catastrophic failures. 2. Enables safe use of a transformer at its end-of-life phase 3. In new transformers, reveals faults originated from manufacturing, transportation or installation 4. Majority internal faults can be detected with online DGA DGA is only online method that can detect various fault types. 5. Following rate of change of gases with online monitoring is more reliable than with laboratory samples. (ref. CIGRE TB409, D1.01 TF 15) 6. Detects faults which might otherwise go unnoticed between regular oil sampling intervals. 2018-04-03 Vaisala 8

Why online DGA monitoring? On-line monitors are particularly useful for applications where gas formation in electrical equipment must be followed at frequent time intervals (e.g., in strategic or expensive equipment, or where significant faults have already been detected). / Cigre TB409 WG D1.01 (TF 15) 2018-04-03 Vaisala 9

Why multi-gas online monitoring Worldwide experiences using on-line DGA increasingly show that all types of faults thermal, low-energy discharge, high-energy discharge, and partial discharge can be identified at an early stage. Identifying type and severity of a developing fault makes timely decisions possible for critical installations. /IEEE Std C57.143-2012 2018-04-03 Vaisala 10

Why multi-gas online monitoring Often hydrogen monitors are used as early warning devices. However, not all faults produce significant amount of hydrogen. PD partial discharge, corona type T1 thermal fault <300 C T2 thermal fault 300-700 C T3 thermal fault >700 C D1 Low energy discharge (sparking) D2 High energy discharge (arching) S Stray gassing of oil < 200 C O Overheating < 250 C C Carbonization of paper > 300 C Temperature at fault location Ref. Dr. Michel Duval 2018-04-03 Vaisala 11

Why multi-gas online monitoring Continuous monitoring of key fault gases gives early and immediate notification of developing faults that may lead to transformer failure. Many failures can be prevented through real-time correlation of DGA data to e.g. load and oil/winding temperature. Only comprehensive online DGA monitoring can provide information that enables automatic condition assessment. Use of diagnostics tools for rapid warning and diagnosis of developing faults. Comprehensive online DGA monitoring recommended for critical and/or heavily loaded power transformers transformers having a gassing pattern. 2018-04-03 Vaisala 12

Things to consider when choosing a monitor Vaisala

DGA monitors - what is relevant for the user? Maintenance needs. Stable long-term measurement for gas trending. No monitoring of monitors! No false alarms. No leaks. Robust design. Easy to install. Tolerates all climate conditions. 2018-04-03 Vaisala 14

Lifetime costs Concerning the overall costs of a monitor, it s not only the price of the instrument to be considered, but also the costs associated with the installation and operation in service over its whole lifetime. +20% Total cost of ownership to be considered when selecting a monitor. 2018-04-03 Vaisala 15

IR technology in online DGA - Vaisala Optimus DGA monitor Vaisala

Infrared absorption (IR) IR is a fundamental analysis method, where light is absorbed by gas molecules. Gases have a unique absorption fingerprint which is used to identify gases present. Absorbed light intensity is proportional to number of gas molecules present in known gas volume. Gas specific absorption wave length does not change over time enabling long-term calibration free operation. 2018-04-03 Vaisala 17

Infrared (IR) absorption by different DGA gases 2018-04-03 Vaisala 18

Infrared technology, operating principle Gas molecules absorb infrared light when exposed to it. More molecules in the gas volume stronger absorption. Measured gas can be selected by changing the wavelength of the light with band-pass filters(s). IR cannot be used to measure gases like H 2, N 2, O 2 2018-04-03 Vaisala 19

Difference in NDIR Technologies (NDIR = non-dispersive infra red) 2018-04-03 Vaisala 20

Gas solubility vs gas extraction How well a gas dissolves into oil depends on: Oil type Temperature Total gas pressure in oil Gas composition in oil Gas solubility in oil is defined as Ostwald. Higher value more difficult to extract the gas from oil. Lower value the easier gas escapes from oil sample. Affects on gas extraction efficiency. 2018-04-03 Vaisala 21

Gas extraction methods Methods to extract gas from oil** Toppler ~100% efficiency Partial vacuum, 90-99% efficiency Head space <30% efficiency Varies by gas type due to Ostwald coefficients and gas to liquid volume ratio Coefficients needed to calculate gas-in-oil concentrations from measured gas-in-gas concentrations C oil = K x C gas **New Techniques for Dissolved Gas-in-Oil Analysis, IEEE Electrical Insulation Magazine, March/April 2003 Vol. 19, No. 2 G-i-G G-i-O Naphthenic Paraffinic Oil density 0.864 0.849 H2 0.074 0.036 O2 0.17 0.18 N2 0.11 0.12 CH4 0.44 0.37 CO 0.12 0.073 CO2 1.02 0.64 C2H2 0.93 0.89 C2H4 1.47 1.27 C2H6 2.09 1.73 IEC60567:2005 2018-04-03 Vaisala 22

Partial vacuum gas extraction Vaisala s monitor uses unique vacuum extraction of gases. No vacuum pump used, oil column as piston. Magnetic gear pump Can extract >95% of the gases in oil. less dependent on gas gas solubility values Magnetic gear pump 2018-04-03 Vaisala 23

Vaisala solutions to prevent long-term drift Drift mechanism Tunable filter Vacuum IRreference Autocalibration Optics vacuum clean + temperature Hermetic Structure Light source Ѵ Filter transmission Ѵ Detector Ѵ Contamination Ѵ Ѵ Ѵ Cross-sensitivity Ѵ Ѵ Ѵ 2018-04-03 Vaisala 24

How to define limit values and interpret the data Vaisala

How to define alarm limits? 1. Comparing to values from standards If no other reference is available. 2. Gas trending and gas ratios. 3. Using specific typical values per transformer family. 2018-04-03 Vaisala 26

Comparing values to standards Typical gas concentration values (ppm) observed in power transformers. Data collected from about 25 electrical networks worldwide and including more than 20 000 transformers (IEC60599 Ed. 2.1 2007): Typical rate of gas increase (ppm/year): 2018-04-03 Vaisala 27

Comparing to values from standards Four-Condition DGA Guide (IEEE C57-104) 2018-04-03 Vaisala 28

Gas trending 2011-2015 2018-04-03 Vaisala 29

Duval triangles H2 CO CO2 CH4 C2H4 C2H6 C2H2 216 237 3657 336 372 100 1.5 PD T1 T3 C T3 Triangle 1 Triangle 5 2018-04-03 Vaisala 30

Duval triangles PD T1 High temperature fault T3, with possible carbonization of paper. T3 C T3 Triangle 1 Triangle 5 2018-04-03 Vaisala 31

PD T1 T3 C T3 2018-04-03 Vaisala 32

Using typical values per transformer family Using typical values per transformer family/design of utility s own fleet. Comparing gas levels and gas RoC of those transformers. Useful especially when transformers of same design have similar loading pattern. This is recommended when sufficiently large transformer fleet is available. Transformer H2 CO CO2 CH4 C2H4 C2H6 C2H2 GSU1 23.9 260 1752 16.5 1.8 4.2 0 GSU2 23.3 301 1854 165.5 228.8 97.1 0 GSU3 16.1 357 2316 21.9 8.7 6.1 0 GSU4 28.2 238 1636 18.7 2.5 5.7 0 GSU5 27 499 2845 18.4 2.5 6.1 0 GSU6 42.3 739 3431 19 2.5 4.7 0 2018-04-03 Vaisala 33

Using typical values per transformer family Transformer H2 CO CO2 CH4 C2H4 C2H6 C2H2 GSU1 23.9 260 1752 16.5 1.8 4.2 0 GSU2 23.3 301 1854 165.5 228.8 97.1 0 GSU3 16.1 357 2316 21.9 8.7 6.1 0 GSU4 28.2 238 1636 18.7 2.5 5.7 0 GSU5 27 499 2845 18.4 2.5 6.1 0 GSU6 42.3 739 3431 19 2.5 4.7 0 2018-04-03 Vaisala 34

Utilizing online DGA data - examples Vaisala

Review data against transformer temperature 2018-04-03 Vaisala 36

Review data against transformer loading 2018-04-03 Vaisala 37

Use of information If transformer generates gases only during loading peaks or exceptionally high temperature, this information can be used in local loading guidance or as input to more efficient cooling. If gas formation does not indicate severe fault, maintenance actions can be scheduled further. If gases indicate critical fault (e.g. acetylene) more immediate actions may be needed to avoid catastrophic failure.? 2018-04-03 Vaisala 38

How to compare online data and laboratory results Vaisala

Accuracy considerations For all methods operating on the headspace principle, a good knowledge of Ostwald or solubility coefficients K is required at all temperatures of gas extraction, in order to calculate gas concentrations in oil (monitor readings) from gas concentrations in the gas phase (actually measured by the monitor) *. Vacuum extraction significantly less dependent on K values. When comparing gas monitor readings to laboratory results, it should be noted that laboratories may have significant uncertainties as well For example the accuracy for a sample with 100 ppm H2 varied between -29% and +22% within the 16 participating laboratories.* * Cigre TB409, WG D1.01 (TF 15) 2018-04-03 Vaisala 40

Laboratory accuracy, in percentage of the nominal value Extraction procedure Medium concentration Low concentration Toepler 13 35 Partial degassing 13 30 Stripping 18 23 Headspace 18 37 Mercury-free Toepler 15* 14* Mercury-free partial degassing 11* Shake test 15 44 * Based on a limited number of analyses. Ref. IEC 60567 Ed 4.0 2011 2018-04-03 Vaisala 41

Laboratory points with ±15% uncertainty bars. Vaisala OPT100 graph ±10%. Laboratory: Located at power plant. Oil analysis within hours. Lab technician takes oil samples. 2018-04-03 Vaisala 42

Laboratory points with ±15% uncertainty bars. Vaisala OPT100 graph ±10%. 2018-04-03 Vaisala 43

Thank you for joining the webinar. 2018-04-03 Vaisala 44