LUMAZOTE T ECHNICAL BRO CHU RE

Similar documents
Thermo Scientific Model 146i Principle of Operation

Application Note AN-107

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

DELTI. Vac. DELTI-Vac MIL. Application. Principle. Characteristic

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Code Basic module and level control complete with optionals code

PRC CO ² -LASER PRESENTATION

CORESTA RECOMMENDED METHOD Nº 67

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

THE PMI AUTOMATED GAS/HELIUM PYCNOMETER PYC-G100A

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

490 Micro GC Site Preparation Checklist

Title: Standard Operating Procedure for Sabio 2010 and 4010 Dilution Calibrator

APPLICATION NOTE. GC Integrated Permeation Device

Svensk läkemedelsstandard

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

Standard Operating Procedure for H 2 S and SO 2 Converter

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Complete Range of Force Tensiometers

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

6890 GC Site Preparation

Customer Responsibilities

Optical Dissolved Oxygen Meter

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Oxidation Stability of Gasoline and Aviation Fuels

LFE OEM TCD - Thermal Conductivity Detector

Vehicle-mounted meters, pump supplied

HumiSys HF High Flow RH Generator

2/2-Way Proportional Valve (motor-driven)

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Discovery HP-TGA 75/750. Site Preparation Guide

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Markes Thermal Desorption Systems Site Preparation Page 1 of 8

High Automation of Thermo Scientific FlashSmart CHNS/O Analyzer using the MultiValve Control (MVC) Module

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

Mass Flow Controller (MFC) for Gases

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

Generating Calibration Gas Standards

Standard Operating Procedure

GAS SUPPLY SYSTEMS. for the flat glass industry

NGN Series nitrogen generator

Customer Responsibilities

Blood Parameter Monitoring System 550

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Electrochemical Sensor

Customer Responsibilities

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

780S Ultra High Purity Series

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

ME3-HCL Electrochemical sensor

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Setting a New Standard in Flash Chromatography Performance

Electrochemical Carbon Monoxide Gas Sensor (Model:ME3-CO) Manual. Version 1.2 Valid from May 1 st 2014

AUTOMATIC HOSE TEST UNIT, TYPE SPU

ON736 Series: Oxygen/Nitrogen by Inert Gas Fusion

This test shall be carried out on all vehicles equipped with open type traction batteries.

User s Booklet for the Wyatt minidawn Light Scattering Instrumentation

Calibration of a GC955

Specifications for the CMI 2409 Magnetocardiograph

HIGH ACCURACY MULTI-GAS MONITORING USING AUTOMATED SELF- CALIBRATION

Boyle s Law: Pressure-Volume Relationship in Gases

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

FTC130 Transmitter. Operating Manual

Gas delivery systems. How to ensure uninterrupted high quality gas delivery from the source to the apparatus? Dr. Gastons Vereskuns Trakai,Lithuania

AIR-X COMPACT AIR-X ON-LINE LUBRICANT AERATION MEASUREMENT. Technical Brochure ON RUNNING ENGINES

FAST EVAPORATION AT NORMAL PRESSURE

FLUORESCENCE DETERMINATION OF OXYGEN

Electrochemical Sensor

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

RM-80 respiration monitor

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Customer Responsibilities

Application Note 268 Metabolic Analysis Systems and Propane-based Verification

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

8.1 Calibration of gas sensors

Mass Flow Controller (MFC) for Gases

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

Optimizing Gas Supply for Industrial Lasers

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

EasyLine Continuous Gas Analyzers. So smart, they re simple

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

Oil Diagnostic Systems. Online and bottle measurement Mobile and stationary operation Lab quality accuracy e

Customer Responsibilities

DOS in Food Science & Nutrition, Manasagangotri, Mysore

MODEL 400 CLD INSTRUCTION MANUAL

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 7820MSD Series G3175A (G7020A), G3176A (G7021A)

The Univentor 1250 Anaesthesia Unit

Vehicle- or rack-mounted liquefied gas meters, pump supplied

Datasheet: K-30 ASCII Sensor

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

Transcription:

by Chemiluminescence Standards AST D4629 / ASTM D6069 / ASTM D 5176 / ASTM D 5762 / NF EN 12260 / NF M 07-058 Licence TOTAL LUMAZOTE T ECHNICAL BRO CHU RE ERALY & Associés Phone: +33 (0) 1 77 04 80 97 4 rue Georges Besse Fax : +33 (0) 1 77 04 80 96 F-78330 FONTENAY LE FLEURY contact@eraly.com

2 1 Summary 1) RESUMED GENERAL CHARACTERISTICS... 4 1.1) Range of application... 4 1.2) Principle of the method... 4 1.3) Detection of NO by Chemiluminescence... 5 1.4) Gas flow sheet... 6 1.5) Mineralization system... 7 1.6) Integrator and calculator... 7 2) CALIBRATION AND MEASURE... 8 2.1) Choice of calibration mode... 9 2.2) Choice of the analysis mode... 10 2.3) Choice of the measurement ranges...10 2.4) Parameters choice...10 3) INSTRUCTIONS OF INSTALLATION...11 3.1) Mechanic...11 3.2) Electric...11 3.3) Gas... 11 3.4) Nature of inert gas...12 3.5) Environment... 12 3.6) The computer... 12 4) FRONT FACE OF ANALYSER...13

3 The CENTRE DE RECHERCHES TOTAL (Research Center of TOTAL) developed this apparatus to answer a major problem of oil industry: To measure automatically and rapidly the very low contents of nitrogen in petroleum products (to 20 ppb) in routine analysis, And in the best conditions possible regarding: Accuracy. Rapidity. Implementation. Comfort of using. LUMAZOTE is the result of this research, and appears to answer to these requirements. In some particular conditions of using, obtained performances may be notably better than those given.

4 1) RESUMED GENERAL CHARACTERISTICS 1.1) Range of application Its overriding range of application concerns the liquid petroleum products (NF M07058 and ASTMD 4629). It can be enlarged to all organic substances compatible with the method requirements. Solvents. Oils. Synthesis products.... 1.2) Principle of the method The analysis goes on in three phases: Destruction of the sample by pyrolysis Mineralisation system and oxidation of the obtained gases N NO Detection of NO formed. Chemiluminescent detector Measurement, signal treatment, calculation. Integrator and calculator

5 1.3) Detection of NO by Chemiluminescence Luminescence is the capacity of lot of substances to emit light when excited. This phenomenon (produces with good energy efficiency) is called chemiluminescence when it is provoked by a chemical reaction. In our precise case, the principle is to detect photons emitted during reaction between nitrogen monoxide NO and ozone O 3. NO + O 3. NO 2 *+ O 2 NO 2 * NO 2 + hv (photon) * excited form The quantity of light with determined wavelength, filtered (in order to eliminate interference with other substances which also generates chemiluminescent phenomenon) and measured by a photomultiplier tube. The signal detected and amplified gives the instantaneous NO concentration.

6 1.4) Gas flow sheet

7 1.5) Mineralization system It is composed with a quartz tube which contains another small quartz tube filled by copper oxide, and one furnace F2: F2 furnace under oxygen at 1050 C for oxidation of the sample. 1.6) Integrator and calculator NO carried in the measurement chamber of the detector provokes the apparition of a NO peak whose surface is proportional to the content of Nitrogen in the sample. An electronic integrator of high precision, associated with a computer, insures the control of the analysis and the calculations to express the results. The computer permits the keyboarding of the sample characteristics (volume, density, weight, reference ). It reads the integrator value, calculates the result and displays it in real time, as well as the concentration graph according to time. Depending on the type of trial requested, the result can be a calibration coefficient, a blank value, a drift measurement or an analysis. At the end of trial, the result and all the analysis parameters are saved on hard disk, and an analysis bulletin is printed.

8 The computer also manages: The syringe pusher process. Some alarms. The saving of the results, measurement parameters, preferences, and so on. Maintenance tools. Three levels of protection by passwords. The possibilities to exploit the results file with a spreadsheet. And so on... 2) CALIBRATION AND MEASURE The proposed method is a comparative method. So it is necessary to make a preliminary calibration. This calibration has to be made with a known product, and considered as a reliable standard or reference. The precision of the results is directly linked to the precision of the calibration products. Standards and customs recommend choosing calibration products as close as possible of the products to analyze, regarding content and nature. The apparatus calculates automatically the mean value of calibrations, as well as repeatability from 5 trials.

9 The validation criterions of good working are the following ones: In liquid mode / calibration: - Stable calibration coefficient at long term ( 5 % of initial calibration values), own for each apparatus (generally near of 1e-008 in range 1) and proportional for the other ranges. - Repeatability near of the following values, depending on contents : - 10 % for 0.05 ppm level - 5% for 0.1ppm level - 1 % for 5 ppm level - ± 1 to 2 % for more than 20ppm level The calibration must be made for each analysis mode and each range. It is recommended to verify it daily, depending on the results precision to be reached. The experience will show that the middle term drifts are very low and that there is a good coherence of coefficients ratios between ranges and modes. Knowing the experimental approximations, it is always possible (for a range and / or a mode) to force an arbitrary coefficient calculated from a calibration made on another range. 2.1) Choice of calibration mode Response of the detector is linear for each selected range or measure scale. So, calibration on one point is enough. However, MIPO 5 software offers possibility to make multipoint calibration for determination of calibration curve. This calibration mode is significant only if made on at least 3 points (down, middle and up of range). Generally, it confirms the effective linearity of detector response, and the passage to zero (or very near). Note: the announced characteristics are verified and apply to current petroleum products at the condition the analysis are normally conducted, in cleanness conditions and with the recommended adjustments. It is possible to gain more sensitivity when working the nearest possible of the inferior limit, with more precautions than standard conditions: - Careful supervision of the cleanness of the tube, connectors and gases circuit. - Preliminary trials to determine the optimum conditions of mineralization. - Establish the coefficient on a 5 trials mean. - Make 2 trials (or more) per determination.

10 2.2) Choice of the analysis mode Liquid mode is used for products which can be sampled and injected directly with a micro syringe (50µl). The sampling volume is measured on the syringe scale (known in lump with the density of product). Gas mode is used for gaseous products, with a gas syringe (5 to 25 ml), sampling volume measured on the syringe scale. Its implementation is the same than with liquid mode. Remark : A solid product can also be diluted for analysis in liquid mode. The user can chose the analysis mode depending on the means of its laboratory and on the researched results. 2.3) Choice of the measurement ranges To be realized on the detector depending on the Nitrogen contents to reach. - liquid mode (50 µl syringe) Recommended ranges, with large possible covering: - range 0,5 : < 1 ppm - range 1 : 0.5 to 10 ppm - range 10 : 5 to 100 ppm - range 50 : > 50 ppm 2.4) Parameters choice The apparatus is delivered with stored parameters automatically called by default. Without other appreciative elements, we recommend to use these parameters by default, or to research and call the parameters of a previous comparable trial in the stored trials file. It is interesting for certain products to optimize the analysis parameters in order to: - reduce the analysis duration - increase eventually the sensitivity and the repeatability of responses - facilitate and secure a using procedure These new chosen parameters can be stored as the new parameters by default.

11 3) INSTRUCTIONS OF INSTALLATION 3.1) Mechanic The apparatus must be set on a laboratory bench top able to receive it in good conditions of safety and access: Support the weight of the analyzer ( kg) and associated computer and printer ( kg) make the following spaces: - length : Apparatus ( 81 cm) + 60 cm space on left side (UV detector rack for maintenance) associated informatics: about 500 to 600 mm for computer + about 500 mm for printer. Total length: about 2.8 m - depth : Apparatus 55 cm + back space for ventilation ( 10 cm) Total depth about 65 cm - height : Apparatus cm (31 + 17) - As the furnaces are placed on the top of the analyzer, it is preferable to allow the above space free (if not, allow at least 50 cm) 3.2) Electric The apparatus has to be connected to the 220 V network 50 Hz single phased, with a 2 poles tap + ground 10/16 A. - Consumption of energy on Analysis mode 1100 W (about 600 when stand by) - The quality of the network must be compatible with a good working of informatics systems. 3.3) Gas The apparatus needs 2 gas supplies: - Oxygen (N48 quality purity 99.998 %) - Inert gas (Argon recommended) (N55 quality purity 99.9995 %) Supply pressures must be comprised between 2 bars minimum and 3 bars maximum. Consumption in analysis mode about 12 l/h (no consumption when awake) Fittings on the apparatus are insured by 2 double ring connectors (type Swagelok) for external 1/8 (3.17 mm) tube. About 2 m of tube are provided with the apparatus. (fittings can be rigid: copper or stainless steel tube in same dimensions). Even if purity of gases is normally guaranteed, it is also essential to verify that lines which carry gases to the analyzer are perfectly clean and tight.

12 3.4) Nature of inert gas - We recommend using Argon. - Helium can be used as inert gas (same purity). However, its viscosity being different, it is necessary to make corresponding corrections on marks of flowmeters balls. - Do not use NITROGEN. 3.5) Environment We recommend to stabilize the working ambient temperature between 15 and 25 C in any case, never more than 30 C (if risks of working in 25 / 30 C conditions, inform us for implementation of eventual particular disposal). Avoid exposing the analyzer in a too hot or too cold place (e.g.: sun behind a window or ventilation of an air conditioner). 3.6) The computer The software insuring the management of SULF UV SL and its options works under Windows XP environment. Minimal configuration required: PC compatible Windows XP, Vista, Windows 7. Processor 1GHz (or more) RAM Memory: 512 Mo. (or more) Hard disk: 10 Go. (or more) Available serial port (COM1 à COM4) allowing a transfer speed of 28800 bauds. Screen SVGA (800 x 600). Colour printer.

13 4) FRONT FACE OF ANALYSER (1) Front face detector (1-1) detector keyboard (1-2) detector indicator (2-2) Interfaces rack (access reserved to or allowed ERALY maintenance) (6) Syringe pusher (6-1) syringe support (8) Combustion tube (8-2) Output joining piece (8-4) Teflon tube 1/8 PFA for joining tube detector (10) Furnace

14 SULPHUR Analyzer by UV fluorescence FRONT FACE OF ANALYSER 8-4 8-2 10 8 6-1 6 2-2 1 1-2 1-1