SERIES 3000 BLANKET GAS REGULATORS

Similar documents
BLANKET GAS REGULATORS

SERIES 3000 BLANKET GAS REGULATORS FEATURES. 3011H cutaway shown Patented US 5,238,021 and 5,931,188

VALVE & FLAME ARRESTER

RCS Rupture Disc Assembly

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

INDUSTRIAL PRODUCT SELECTION GUIDE

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

SERIES 10. Pilot Operated Tank Blanketing Valve, 2" PROTECTOSEAL.

ANDERSON GREENWOOD TANK BLANKETING REGULATORS

Model TB 3-16 TECHNICAL BULLETIN. Secure-Gard Pilot Operated Vent Valve (POVV) BENEFITS TYPICAL APPLICATIONS FEATURES

Mark 958 Series Sanitary Gas Back Pressure Regulators

Types ACE95 and ACE95Sr Tank Blanketing Valves

PILOT OPERATED RELIEF VALVE SAFETY PRODUCTS THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT

N2 Blanketing Valve DST100 / DST200 TYPE INSTRUCTION MANUAL CONTENTS K.S.P.C. General Description Operation. Installation Maintenance

Types ACE95 and ACE95Sr Tank Blanketing Valves

Type ACE95jr Tank Blanketing Valve

Types ACE95 and ACE95Sr Tank Blanketing Valves

PILOT OPERATED PRESSURE VACUUM RELIEF VALVE MODEL 1660

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Mark 958 Series (3/4" - 1") Sanitary Gas Back Pressure Regulators

Tank Blanketing Pressure Regulators RHPS Series

INDEX. Table of Contents. Warranty. ISO 9001 Certificate. Product Selection Guide

CAL-VAC POS-A-SET R U PT URE

PRODUCT SELECTION GUIDE

Model PRS-07i. Stainless Steel Low Pressure, In-Line Pressure Regulator (Reducing Valve)

Type 1190 Low-Pressure Gas Blanketing Regulator

WASTEWATER SAFETY DEVICES THAT PROTECT BIOGAS CATALOG EQUIPMENT, LIVES & THE ENVIRONMENT SMART RELIEF...SAFE SOLUTIONS SM

Self-operated Pressure Regulators for special applications

Type Y692 Gas Blanketing Regulator System

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

94060 FRP Conservation Vent. Features. FRP Conservation Vent. One piece construction prevents product leakage

94060 FRP Conservation Vent. Features. FRP Conservation Vent. One piece construction prevents product leakage

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

MODELS 1500, 1520, 1530, 1560

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

Tank Blanketing Regulators

Installation, Operation and Maintenance

Tank Blanketing. Application Jordan Valve Product Offering Competition

Type EZH Relief or Backpressure Regulator

Model Secure-Gard Pilot Operated Vent Valve SECTION II. Remove all packing material inside and outside of the valve prior to installation.

T208VR Series Tank Blanketing Vacuum Regulator

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes

Model 8800A. Pressure Relief and Vacuum Breaker Valve with Flame Arrester

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Pressure Reducing Valves Pressure Reducing with. Broady Flow Control. C Series Range. Pressure Reducing Valves. Broady Flow Control

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

Models 1720A / 1760A

Tank Blanketing Regulators

Y692VB Series Vacuum Breaker

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Mark 695 Series . JORDANVALVE. Piloted Tank Blanketing Regulator 3/4"- 1"

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

CP200 Series Commercial / Industrial Pressure- Loaded Pressure Reducing Regulator

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Maximum Pressure Differential and Maximum Inlet Pressure for Various Soft-Seated Valve Materials* Introduction. Body Pressure Ratings

PROTEGO Pressure and Vacuum Relief Valves. Volume 6. in-line. Volume 6. for safety and environment

VAPOR CONTROL SYSTEMS QUALITY, DEPENDABILITY, SERVICE. REPUTATION BUILT ON. Valve Concepts, Inc. com. A Cashco, Inc.

Pressure Sensing Valve - Model 4023

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Model Application TECHNICAL BULLETIN TB Vacu-Gard Tank Blanketing Valve 1/2 (DN15) FEATURES. Valve Concepts, Inc.

Welcome to the LESER Seminar, Taipei 28. June Design_of_safety_relief_valves_250804_Cal

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

S300 Series. Valve Link. Features. Fisher Controls

Precision and Instrument Regulators 1/4" port size

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

Specialty Gas Equipment Catalogue

V DGX Series. Direct-Operated Regulators Manual D103834X012

V DFX Series. Direct-Operated Tank Blanketing Regulator Manual D103808X012

299H Series Pressure Reducing Regulators

1200 Series Pressure Regulators

Model 1800 PFM Series Regulator. Technical Bulletin

Anderson Greenwood Type 4142 piped away pressure relief valves

PROTECTOSEAL V A P O R & F L A M E C O N T R O L E Q U I P M E N T

Full Range Pressure Compensating Variable Flow Control

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

Safety Shut-off Valve SSV

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

FLAME ARRESTOR MODEL L76C-UF

PROTEGO Braunschweiger Flammenfilter GmbH

Model Application TECHNICAL BULLETIN TB Vacu-Gard Tank Blanketing Valve 1 & 2 (DN25 & DN50) FEATURES

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Pressure Regulator 133 / 233

Blanketing Valve ZM-R. low pressure reducing valve

MEGR-1627 Instruction Manual

RR 16 Commercial & Industrial Regulator

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

MODEL 240 GAS PRESSURE REGULATOR

JSRH Series. Sanitary Valves JSRH Series High Flow Pressure Reducing Valves. High Flow Bio-Pharma Clean Gas Pressure Reducing Valves

MODEL 273PL GAS PRESSURE REGULATOR

BACK PRESSURE / SUSTAINING

VRD Series VRD40.xxxUx Double Valves for use with SKP... electro-hydraulic actuators

ZUERCHER BR Series LOW PRESSURE IN-LINE & ANGLE-PATTERN TANK PRESSURE REDUCING REGULATORS

GAS PRESSURE REGULATORS AP

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Transcription:

SERIES 000 BLANKET GAS REGULATORS Numbers:,, P, 00A, 00, 01L, 01H, 01HP WHAT IS A BLANKET GAS REGULATOR? A blanket gas regular supplies an inert gas prevent a vacuum from developing when liquid is removed from a tank, maintain the desired blanket pressure when the temperature drops, and prevent outside air from contaminating the tank or creating a flammable or explosive environment. Features Simple operation, spring-loaded push-push balanced pisn design Bubble-tight shut-off Variable orifice, field-adjustable flow capacity Single stage regular ranges from 0. 1 Set pressure is field adjustable Modulating opening imal lockup and droop Benefits Low maintenance cost Provides optimum gas blanketing of tank and product being sred Prevents evaporation of product and reduces corrosion of tank by providing blanketing gas in vapor space Prevents a flammable or explosive environment in the tank vapor space Ensures pressure is maintained in the vapor space of a srage tank cutaway shown Eliminates the need for a multiple regular system or for complicated pilot operated blanketing Materials Available in 1 stainless steel or other material by request

Why Gas Blanketing? Blanket gas regulars from Groth Corporation ensure that a constant gas pressure is maintained in the Emergency Relief Valve +0.8 +1 A, A, 0A, 00A Pressure/Vacuum Relief Valve 0.8 +1 / -0.8-1 1A, A, 10, 10A, 8800A, 880A Blanket Gas Regular From 0. w/one regular,, P, 00A, 00, 01L, 01H, 01HP OPTIONS To complete your blanket gas system, Groth Corporation can provide a vapor space of a srage tank. A blanket gas regular supplies an inert gas prevent a vacuum from variety of additional devices developing when liquid is removed from a tank, maintain the desired blanket pressure when the temperature drops, and prevent outside air from contaminating the tank or creating a flammable or explosive environment. A blanket gas pressure as low as 0. prevents outside air and moisture from entering the srage vessel and reduces evaporation of the sred product a negligible amount. The end result: product conservation and significant reduction in tank emissions. The simple design of a Groth blanket gas regular eliminates the need for a multiple regular system or complicated pilot operated blanketing valves. Groth units have tally balanced chambers offer high accuracy and reliability, and ensure a leak-tight design without the need for a pilot valve operate the unit, thus reducing maintenance costs. Not all models may be set the complete range. Optimum Protection for measuring, managing, and maintaining the cleanliness of your srage system: Gauges Purges Filters Contact Groth Corporation or your local representative for more information. Groth blanket gas regulars provide a controlled gas environment in srage tanks for the following applications: Refineries Chemical & Petrochemical Plants Liquid Bulk Srage Terminals Pulp & Paper Plants Food & Beverage Srage For optimum protection of a tank and meet all regulary requirements, each tank should be protected by 1) a properly-sized blanket gas regular, maintain the vapor pressure in the tank, ) a properly-sized pressure/vacuum relief valve or pilot operated valve, release the vapor during pump-in or thermal expansion, and ) a properly-sized emergency relief valve protect against pressure rise due external fire. Tank protection systems can be combined across multiple tanks, but careful consideration must be given provide adequate relief and input capacity and prevent fouling or clogging of system piping. Consult the facry for assistance in these situations. A Groth blanket gas regular will prevent evaporation or contamination of product by maintaining the proper atmosphere and pressure on the product sred in a tank. A Groth pressure/vacuum relief valve or pilot operated valve with vacuum relief will prevent vapor from escaping in the atmosphere until the set pressure is exceeded, and provide vacuum protection in case of a gas supply failure. The emergency relief valve will provide vessel protection under control system failure or external fire conditions. The complete system can be provided by Groth Corporation. Benefits of srage tank blanketing are recognized by the following government regulations and industrial standards: API Standard 0 ISO 800 EPA Publication AP- NFPA 9 - Standard on Explosion Prevention Systems OSHA Part 19.1

OPERATION & FLOW CAPACITY MODEL SELECTION Flow Capacity Required flow capacity should be determined by using API 0 ISO 800 or the relevant sizing standard. To find the rated capacity for your application, please refer Table 1, Flow Capacity. Capacity is listed as a function of supply pressure for three typical blanket gases: CO, nitrogen, and natural gas. The flow capacities in the table are achieved with the 0% orifice selection. For reduced capacity, multiply the table values by the reduced percentage. Operation The Groth blanket gas regular maintains vapor pressure in a tank by opening the supply gas valve when tank pressure (through a sense port) falls below the specified set pressure. When tank pressure is at or above the set pressure, the plate diaphragm is held up by tank pressure. Through the force-multiplying actuar arms, the pisn is held up against the spring pressure, and the supply valve is closed bubble-tight. When the tank pressure falls below the set pressure, the spring force overcomes the pressure. The pisn moves down, and supply gas is released in the tank. The actuating pisn has identical effective areas on the lower pisn seal and the o-ring. This balances the opening and closing forces caused by supply pressure; variable gas supply pressure will not have an effect on regular operation, which eliminates the need for an external pilot control. Pressure against the diaphragm provides direct action against the spring. This push-push design provides maximum force operate the regular and provide a bubble-tight seal. The flow capacity can be limited by the rotatable orifice selecr sleeve. Reducing the blanket gas flow capacity may reduce the need for excessive pressure relieving capacity on smaller tanks. The sleeve is field adjustable from 0% % capacity, and can be locked down prevent tampering. Table 1 Flow Capacity (Applies s, P, 00A, 01L, 01H, and 01HP. Consult facry for 00) Flow Capacity 1/ Flow Capacity 1 Pressure Natural GAS Natural GAS Carbon Dioxide Nitrogen Carbon Dioxide Nitrogen 0. SG 0. SG SCFH NCMH SCFH NCMH SCFH NCMH SCFH NCMH SCFH NCMH SCFH NCMH 0. 10 1 8 80 0 00 800 1 00 09 0.9 0 9 0 90 1 0 01 8800 9 10 0 1 1.0 0 1 90 90 09 9 0 10 100 1 0 1.8 1 80 189 880 1 00 9 1900 0 0.0 0 188 80 1 10 18900 0 9 0. 8 0 90 00 10 89 18800 00 8 0000 89 0. 90 10 10 8 98 800 1 0.1 10 1 1880 000 00 9 0 80. 80 01 180 90 8 000 9 0 9 00 189 0.89 1 8 0 900 8 0000 00 8 00 180 8. 0 90 9 000 8800 1 800 9. 0 00 8 90 900 1 00 19 8900 1 10.0 0 9 0 1 0900 1 00 19 9000 180 1. 90 88 800 90 199 900 19 8000 0 80 09 80 91 1990 88 0 1 900 900 9 Note: Unless otherwise specified, the orifice selecr sleeve is facry set at 0% capacity. Table Positive Pressure Selection Guides 1/ BGR Pressure / 0. 0.99 1.. 1.0 1.9.. 1. 1.99..0.0.0 0 0. 0.99 1.. 1.0 1.9.. 1. 1.99..0 mbar.0.0 1. 1.99 1.0 1 0.1 1.0 OUTLET 1 0.. >1 1. >1.0. >. 1 BGR Pressure / 1 0.. >1 1. >1.0. P 00A OPEN INLET >. REMOTE SENSE PORT ½ FNPT Table Negative Pressure Selection Guides 1/ BGR Pressure / -0. -0.99-1. -. -1.0-1.9 -. -. -1. -1.99 -. -.0 -.0 - -.0-0 -0. -0.99-1. -. -1.0-1.9 -. -. -1. -1.99 -. -.0 -.0 - -.0-1 -. -1.99 1 OUTLET 1 0.. >1 1. 01H >1.0. >. 01L 1 BGR Pressure / 1 0.. >1 1. 01H >1.0. 01HP CLOSED INLET 01L >.

SPECIFICATIONS SPRING RANGES Table / Pressures Table s Notes: Number 01L 01H imum 0. 1. -0. -1. 0. 1. 0. 1. -0. -1. -0. -1. 1.0. -1.0 -. 0. 1. 0-0. -1. - -0 1/ Blanket Gas Regular Allowable Working Pressure (MAWP).0 0.1.0 0.1 0. 0. 0. 0. imum set pressure for with supply pressure is 1. Pressure (MSP) 0. 0. Shipping Weight lb kg 1.9 1.9.... No. / (01L) / (01H) 1/ Blanket Gas Regular 0. 0.9 1. 1.9 0.8 1.0.0. 0 0. 0.9. 1. 1. 0. 1.9 1..1 1..99...0.9. 1.. 0.0 When spring ranges overlap, select the lighter spring / setting applicable both pressure and vacuum (vacuum model when used) Consult the facry for regulars with settings less than - Number P 00A 00 01L 01H 01HP imum 0. 1. 0. 1.. 1.0 0.1 0. 1. -0. -1. mbar -0. -1. mbar -. 1.0. 1.0 0,1 0.8 1 1.0 -.0 - -. -1 -.0-0.1 1 Blanket Gas Regular Allowable Working Pressure (MAWP) 0.1 8 0. 1..1 0.1 8 0. 1. NOTE: When spring ranges overlap, select the lighter spring. Consult the facry. Pressure (MSP) Shipping Weight Lb (kg) 1 1 1 9 1 No. / (01L) / (01H) 1 Blanket Gas Regular No. 0. 0.9. 1. 1.9 1.. 0.8 0.99.1 18. 1..9..1 1.0 1.99 P/ 18....0 (01HP). 8. 0 0. 0.99 1.0 1. 1. 1..9 9.0 9. 0 1.0 1.9 1.8.0..9 9. 18 1. 1.99.0....99 18 1.0.9..0.0 8.9 8 00A..1. 8. 1.19 9.. 1.0 1. 0.0 0

HOW TO ORDER How Order Standard BGRs For easy ordering, select proper model number MODEL # Using Table or 01L 01H P 01HP 00A 1" Regulars 1/" Regulars EXAMPLE INLET MATERIAL SOFT ORIFICE Selecr SPRING OPTIONS OUTLET GOODS Position RANGE Inlet Outlet E = 1/" # ANSI RF Flange O = 1/" NPT F = DN1 PN /1 DIN RF Flange S = 1/" Sanitary Connections Q = 1/" Quick Couplings A = 1" # ANSI RF Flange N = 1" NPT C = DN PN /1 DIN RF Flange R = 1" Sanitary Connections Body Material = 1 SS B = Buna-N C = CHEMRAZ E = EPDM V = VITON Z = Special Orifice Selecr Position 1 = 0% = % = 0% = % = 0% = 1% = % 8 = % Not available for 1/" size. Select from Table Options O = No Options Z = Special Options 0 1 1 H N V 1 0 Indicates a Regular with 1" NPT body connections, 1 SS construction, VITON elasmers, full capacity orifice, set pressure range from 1.0 1. and no special requirements. Notes: Include model number when ordering For special options, consult facry See flow table for available sizes Consult the facry for regulars with settings less than - Actuar diaphragm is only available in TEFLON PFA Pressure Equipment Directive Available When Specified GROTH CORPORATION 10 N. Promenade Blvd. Stafford, TX USA Phone: (81) 9-800 Toll Free: (800) -8 Fax: (81) 9-999 E-mail: sales@grothcorp.com Website: www.grothcorp.com CORPORATE HEADQUARTERS 10 W. Heartland Drive Liberty, MO 08-8 USA Phone: (81) 9-0 FAX: (81) 9- / E-mail: pressure@contdisc.com Website: www.contdisc.com THE NETHERLANDS Energieweg 0 8 NJ Zoeterwoude-Rijndijk The Netherlands Phone: + (1) 1- FAX: + (1) 1- E-mail: cdcnl@contdisc.com CHINA Room 9, Tower B, COFCO Plaza No. 8 JianGuoMenNei Avenue Beijing (000), P.R. China Phone: + (8) --88 Fax: + (8) --88 Mobile: + (8) 1-0-881 E-mail: cdcchina@contdisc.com INDIA Groth Continental Mfg. Pvt. Ltd. /P/, Mahagujarat Industrial Estate, Moraiya, Sarkhej-Bavla Road, Ahmedabad (GJ) 81, INDIA Phone: +91 1 19 Fax: +91 1 19 E-mail: gcmpl@contdisc.com CHEMRAZ is a registered trademark of Greene, Tweed & Co VITON is a registered trademark of DuPont Performance Elasmers TEFLON is a registered trademark of DuPont and used under license by Groth Corporation reserves the right alter the information in this publication without notice. Printed in U.S.A. Reproduction without written permission prohibited. 0 Groth Corporation LIT0 0