L15 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE TAKE CONTROL Take control with Muncie Power Products L15 directional control valve. The L15 is constructed with high-grade, iron castings and nickel-plated spools for use in high pressure applications and can be configured with many different spool, control and positioner options. The L15 is designed for flow rates up to 4 GPM (15 LPM), and offers superior performance in a compact package. Muncie Power Products takes pride in supplying the highest quality products along with outstanding service and support. KEY FEATURES High-grade iron castings allow for high pressure capabilities for the most extreme applications Nickel-plated spools resist wear allowing for long life under high pressure conditions TECH SPECS DESIGN TYPE Maximum Work Sections Circuit Types Flow Capacity SECTIONAL 1 Closed center load sense post compensation Nominal: 33 GPM (15 LPM) Maximum: 4 GPM (15 LPM) Tight tolerances and precision machining keep internal spool leakages low Internal oil core design allows for higher flow rates and low pressure drops Load-checks on work sections and inlet relief valves are standard Versatile design can be configured with different spool, control, positioner and accessory options Work sections are pre-assembled and 1% tested prior to shipping Additional options available, lead times may apply. Maximum Pressure Maximum Back Pressure Stand by Pressure Recommended Filtration Oil Viscosity Range Oil Temperature Range Recommended Oil Temperature Approximate Weights (Standard Options) 5,75 PSI (35 BAR) 145 PSI (1 BAR) PSI (14 BAR) /18/15 (ISO 446:1999) 6 to 1,36 SUS (1 to 3 cst) -4 to 185 F (-4 to 85 C) -4 to 14 F (-4 to 6 C) Inlet: 13.8 lbs. (6.6 kg) Outlet: 8.3 lbs (3.74 kg) Work Section: 8.8 lbs (4. kg) (Manual Control) 1.8 lbs (4.9 kg) (Electrohydraulic Control)
PERFORMANCE CURVES FIXED DISPLACEMENT SYSTEMS Post Compensated Spool Flow Characteristics Flow (GPM) Stroke (mm) -7-6 -5-4 -3 - -1 1 3 4 5 6 7 1 5. 95 9.5 85 1.3 Spool 8. 75.6 Spool 7 17.5 4. Spool 65 6 15. 6.6 Spool 55 9. Spool 5 1.5 45 13. Spool 4 1. 17. Spool 35 7.5 1 Spool 3 5 5. 6.4 Spool 15.5 1 5. -.7 -. -.17 -.1 -.7 -..3.8.13.18.3 Stroke (Inches) Flow (LPM) 14 Spool Travel with Electric Current or Hydraulic Pressure Stroke (mm) 1 3 4 5 6 7 8 3 1 5 1 Current (ma) 8 6 15 Hyd. Pressure (PSI) 4 1 5 1V Current (ma) 4V Current (ma) Pressure (PSI)..5.1.15..5.3 Stroke (in)
Inlet Compensator Pressure Drop for Fixed Displacement Pumps (P-T) Flow (lpm) 4 6 8 1 1 14 19.3 7 18.3 5 17.3 16.3 Pressure (psi) 3 1 15.3 14.3 Pressure (bar) 19 13.3 1.3 17 11.3 15 5 1 15 5 3 35 Flow (gpm) 1.3 VARIABLE DISPLACEMENT SYSTEMS Post Compensated Spool Flow Characteristics as a Function of Pump P Setting Pump ΔPressure (BAR) 1 14 16 18 4 6 14 35 1 3 1 5 Flow (GPM) 15 8 6 Flow (LPM) 1 4 5 174 199 4 49 74 99 34 349 374 Flow ΔPressure (PSI) 1.3 Spool.6 Spool 4. Spool 6.6 Spool 9. Spool 13. Spool 17. Spool 1. Spool 6.4 Spool
DIMENSIONS MANUAL CONTROL VERSION Port Size and Type Inlet Ports = -1 SAE Work Ports = -1 SAE T1 Outlet = -1 SAE T & T3 = -6 SAE 1. 3.5 6.5 165. 4.37 111. Spool Travel Total.55 14..4 6. 3.48 88.5. 56..31 8. 3.33 84.5 1.4 36. 4.96 16. 1.54 39..73 18.66. 56..61 15.5. 5.84 T Port B Port A Port 1.18 3..75 19. 1.38 35. T3 Port 3.54 [9.1] + # of WS x 1.5 [38] 1.5 38.1 1.5 38.1 1.93 49.1 1.18 3..36 6.1 1.18 3..96 4.5.18 4.5 LS Signal Port -6 SAE P Port. 55.96 1.81 46. T1 Port 3.11 79. 1.61 41. 16 16.59 15..31 8. Gauge Port -6 SAE Position Positon 1 Position.4 [56.9] + # of WS x 1.5 [38] 4.39 111.5.71 18. 6.4 163. M1 (3 Places) 1.69 43. Main RV Standard Setting 3,65 PSI (5 BAR) LS RV Standard Setting,9 PSI ( BAR) Position Position 1 Position Pressure N/A A Port B Port Handle Neutral Pulled Out Pushed In
ELECTROHYDRAULIC CONTROL VERSION Port Size and Type Inlet Ports = -1 SAE Work Ports = -1 SAE T1 Outlet = -1 SAE T & T3 = -6 SAE 1. 3.5 6.5 165. 4.37 111. T3 19. 3.96 1.5 3.48 88.5 19. 1.73 44..43 11. 3.17 8.5.6 66.5.61 15.5 B Port. 56.4.1 51.1 A Port T 1.18 3. 1.93 49. 3.54 [9.1] + # of WS x 1.5 [38] 1.5 38. 1.5 38. 1.93 49..36 6. 1.18 3. 1.18 3..96 4.5 LS Signal Port -6 SAE.18 4.5 P Port. 56. 1.81 46. T1 Port 3.11 79. 1.61 41..59 15..4 [56.9] + # of WS x 1.5 [38] Gauge Port -6 SAE 1.7 [43.] 4.39 111.5.63 16..71 18. 6.4 163. M1 (3 Places) 1.69 43. Main RV Standard Setting 3,65 PSI (5 BAR) LS RV Standard Setting,9 PSI ( BAR)
BACK-CAP OPTIONS Manual Control Options CONTROL OPTIONS L15-BC-1 Standard 3 Position, Spring Center 1 1.59 4.5 L15-CT-AA Standard Lever Cap *(Note: Handle Lever Not Included) P/N VLVH-1-B-18) M8 1 L15-BC-6 6 Detent Spool IN, Spring Spool Out 1 L15-BC-8 3 Position Dentent (Detemnt in A and B Only, Spring Return to Neutral) 1 1.93 74.5.93 74.5 L15-CT-AB Lever Cap for Float Spool *(Note: Handle Lever Not Included) P/N VLVH-1-B-18) M8 3.16 8.3 3.16 8.3 1 L15-BC-1 3 Position Spring Return With 4th Position Dentent 1 3.93 74.5 L15-CT-AJ Spool Eye Only for Direct Connection 3 1.8 7. L15-BC-33 Pneumatic Air Shift, On/Off or Proportional (Use w/control Type AA, AE or AJ 1 4.6 13. L15-CT-AK Spool Eye Only for Direct Connection.5 1.7 Electrohydraulic Options (Must be used together) L15-BC-49 3 Position Electrohydraulic Control, Proportional 1 VDC (Deutsch) 5.7 144.7 L15-CT-BV 1VDC Electrohydraulic Proportional Control With Lever Connection and Stroke Limiters 5.7 144.7 M8.68 68. 3.7 83.
INLET SECTIONS L15-A-QK-J-5--X MPP Valve Series L15 = 33 GPM Nominal LS Valve Section Type: A = Inlet Port Type: QK = -1 SAE by -1 SAE w/-6 SAE LS Port Inlet Options: K = Inlet for Fixed Displacement Pumps Has Main RV and LS RV J = Inlet for Variable Displacement Pumps Has Main RV and LS RV Special Features: X = Standard LS Relief Valve Setting*: 13 = 1,815 PSI (15 BAR) 15 =,175 PSI (15 BAR) =,9 PSI ( BAR) Standard Main RV Setting*: 17 =,4 PSI (165 BAR) =,9 PSI ( BAR) 5 = 3,65 PSI (5 BAR) Standard *LS Relief must be, at minimum, 58 PSI (4 BAR) less than the Main RV INLET RELIEF VALVES (Main & Load Sense) L15-AB- L- - LS L15 Valve Series L15 = 33 GPM Nominal LS Valve Section Type: AB = Used with Inlet Relief Valve Adjustment Range: Main RV Options: N = 58-,9 PSI (4- BAR) R =,915-6,9 PSI (1-4 BAR) Load Sense RV Options: L = 75-3,65 PSI (5-5 BAR) M = 3,64-5,75 PSI (51-65 BAR) Relief Valve Use: Leave Blank for Main Relief Valve LS = Load Sense Relief Valve Relief Valve Setting in BAR: Main RV Options: 165 =,4 PSI =,9 PSI 5 = 3,65 PSI Load Sense RV Options: 15 = 1,185 PSI 15 =,175 PSI =,9 PSI END PLATES L15 Valve Series L15 = 33 GPM Nominal LS Valve L15- C-ER-1MI-XXX Additional Outlet Options: XXX = No options Section Type: C = End Plate Port Size & Type: ER = -6 SAE by -6 SAE LS Drain Ports Outlet Type: 1MI = End Plate for Manual Controls EH = End Plate for Electro-Hydraulic Controls STUD KITS L15-T- 1 L15 Valve Series T = Tie Rod Number of Work Sections 1-1 (1-1 Work Sections) "L" M1 M1 No. of Work Sections 1 3 4 5 6 7 8 9 1 L (in/mm) 3.74 / 95 5.4 / 133 6.77 / 17 8.7 / 1 9.76 / 48 11.3 / 87 1.76 / 34 14.1 / 361 15.75 / 4 17.4 / 438
MODEL NUMBER CONSTRUCTION WORK SECTIONS L15-ZR-AA-1 FM--X L15 Valve Series L15 = 33 GPM Nominal LS Valve Spool Type: Spool Code Max Flow Cylinder Motor 4th Pos. GPM LPM ZC YE -- 1.3 5. ZD YF XH.6 1. ZE YG -- 4. 15. ZF YH -- 6.6 5. ZG YJ XM 9. 35. ZJ YM -- 13. 5. ZM YP XS 17. 65. ZN YR XT 1. 8. ZR YT -- 6.4 1. Control Type: AA = Handle Control Actuator (handle not included) (See note 1) AB = Handle Control Actuator for 4th Pos. Spools ( handle not included, see Note 1) AJ = Spool Eye Only for Direct Connection AK = Spool Eye Only for Direct Connection (for 4th pos. spools) BV = A Side Electrohydraulic Control w/stroke Limiter and Connection for Backup Lever (1V Deutsch) (See notes 1 & ) Back-cap Positioners & Controls: 1 = 3 Position, Spring Return 6 = Detent Spool IN, Spring Spool OUT 8 = 3 Position Detent 1 = 3 Position, Spring Return with 4th Position Detent 33 = Pneumatic Positioning (On/Off or Proportional) 49 = B Side Electrohydraulic Shifter (1V Deutsch) (See Note ) WORK PORT OPTIONS L15-W33-Z-13 L15 Valve Series Work Port Option: W33 = Work Port RV + Anti-Cav WCX = Blanking Plug Setting Range: Z = No Range, Used with W33 X = Used with WCX Special Features: X = No Option (Standard) Work Port Options: = Machined w/steel Plugs (Standard) Combined Relief & Anticavitation Valve Options RV+AC Set @ 75 PSI (5 BAR) NOT ADJUSTABLE 5 = RV+AC on A Port, Set at 75 PSI (5 BAR) 51 = RV+AC on B Port, Set at 75 PSI (5 BAR) 5 = RV+AC on A & B Port, Set at 75 PSI (5 BAR) RV+AC Set @ 1, PSI (8 BAR) NOT ADJUSTABLE 47 = RV+AC on A Port, Set at 1, PSI (8BAR) 48 = RV+AC on B Port, Set at 1, PSI (8 BAR) 49 = RV+AC on A & B Port, Set at 1, PSI (8 BAR) RV+AC Set @ 1,9 PSI (13 BAR) NOT ADJUSTABLE 53 = RV+AC on A Port, Set at 1,9 PSI (13 BAR) 54 = RV+AC on B Port, Set at 1,9 PSI (13 BAR) 55 = RV+AC on A & B Port, Set at 1,9 PSI (13 BAR) Steel Plug to create P-T for Single Acting Function 56 = Steel Plug on A Port for Single Acting Function on B 57 = Steel Plug on B Port for Single Acting Function on A Port Type FM = -1 SAE Notes: 1. Standard Handle Kit P/N: VLVH-1-B-18 (Length: 7" (18mm)). Control BV and Back-cap 49 must be used together RV Setting (in Bar): Standard Settings: 5 = 75 PSI (5 BAR) 8 = 1, PSI (8 BAR) 13 = 1,9 PSI (13 BAR) XXX = No Setting ORDER EXAMPLE Part Number Qty. Description If you would like to order an assembled valve, you will need to order each item separately. The order in which parts are entered is how the valve will be built from left to right. On the right is an example of a 3 work section valve order: L15-A-QK-J-5--X 1 Inlet with relief valve & LS Relief L15-ZR-AA-1-FM--X Work section 1 & L15-YH-AJ-1-FM-5-X 1 Work section 3 VLVH-1-B-18 7." (18mm) handle kits for WS 1 & L15-C-ER-1MI-XXX 1 Standard outlet L15-T3 1 Stud kit for 3 section assembly Member of the Interpump Group MP17-1 (7-17) 1 East Jackson Street Muncie, Indiana 4735 8-367-7867 Fax 765-84-6991 info@munciepower.com www.munciepower.com Specifications are subject to change without notice. Visit www.munciepower.com for warranties and literature. All rights reserved. Muncie Power Products, Inc. (17)