Installation Instructions

Similar documents
Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

This parts list is current as of the above revision date. See for the current revision.

RPLA. Heat Pumps. Parts List 19-July-2011

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

This parts list is current as of the above revision date. See for the current revision.

Tru Trak Sulky Proline Mid Size Mower Attachment

INSTALLATION INSTRUCTIONS A-Arm Guards, Rear Part Number: Application: Kawasaki Brute Force 750 4x4i

MODEL SWH10 1,000 LB CAPACITY SWIVEL HOIST

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3

RPNK. Heat Pumps. Parts List 25-July-2011

709 and 710 Stud Punches

Installation Instructions

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Tube-Line Accelerator Spinner Kit

VL 2K LIFT D-L WINCH INSTRUCTIONS (Applies to P/Ns , , , , , )

This parts list is current as of the above revision date. See for the current revision.

RPKA. Heat Pumps. Parts List 07-May-2014

Installation and Service Manual

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

AE R1 February 2015

Owner s Manual High Density Sports Storage Partial End Closure Accessory 32-inch Partial End Closure 48-inch Partial End Closure

Air Intake Snorkel Kit

60 farm jack. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

35 TON HYDRAULIC PUNCH WARNING

Model # MHVSS Vertical Sausage Stuffer INSTRUCTION MANUAL

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Nordic Model CCM0330, 0430, 0530, 0630 Service Parts Manual (Includes 50Hz. Units)

INSTALLATION & OPERATION MANUAL. Dual Duct VAV Terminals. Redefine your comfort zone.

COOPER POWER SERIES. D-73P3 bypass switches installation instructions. Switches MN008005EN. Effective April 2016 Supersedes S June 2013

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

User s Information Manual

30T A/Manual Hydraulic Shop Press

MAINLINE MLA14 AIR CONDITIONERS

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A4-T4-W4, ICE0400A3-T3-W3 MODEL - ICE0500A3-T3-W3-R4, ICE0606A3-T3-W3-R4 Includes 50Hz.

Operating Instructions Part No

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Arbor Terminator Press Operation Manual For IDT Connectors Order No Engineering No: AM

Installation Instructions For Propane Gas Conversion (Kit Part No ) This kit is designed for conversion to Propane Gas

444C DUAL PERFORMANCE VALUE PACK

ACCESSORY KIT INSTALLATION MANUAL

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

Effective March 2015 Supersedes S August 2002

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

Manual: GPK1 - Gin Pole Kit Accessory for the ARRS1-AMKUS Rope Rescue System

Installation Instructions For Natural Gas Conversion

Installation Instructions

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A5-T5-W5, ICE0400A4-T4-W4 MODEL - ICE0500A4-T4-W4-R5, ICE0606A4-T4-W4-R5 Includes 50Hz.

NGP-250/500 Nitrogen Generator Quick Start Guide

IMPORTANT SAFETY INSTRUCTIONS

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

MODEL 300 BACKLAPPER OWNERS MANUAL

NOTE: Parts are no longer available for this tool. The manual will continue on the next page.

ACCESSORY KIT INSTALLATION INSTRUCTIONS

200 PSI COMPRESSORS - MODEL NUMBERS

Specifications Testing & Adjusting Disassembly & Assembly

COOPER POWER SERIES. UltraSIL Polymer-Housed Distribution-Class MOV Surge Arrester Installation Instructions. Surge Arresters MN235006EN

VL PONTOON/TRITOON DECK BRACKET 13 INSTRUCTIONS

DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers

Installation Instructions for the Walking Beam Interlock for Eaton EHD, FDB, FD, HFD, FDC, FW, HFW, FWC, Circuit Breakers and Molded Case Switches

This parts list is current as of the above revision date. See for the current revision.

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

Operator s Manual. with Maintenance Schedule. Fourth Edition Second Printing Part No

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Installation Instructions

OPERATOR S MANUAL SPREADER. CSS, VNQ [For Combine Harvester AW82V] Original instructions

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

SM6. instructions for use. connection with compartment for incoming cable from the top. MV distribution factory built assemblies at your service

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in

100C Air Compressor Kit

2000 lb manual winch

Peak Pressure Indicator MSI-3

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Portable Oil Lube Air Compressors

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

VERTICAL SURFBOARD CARRIER READ ME! IMPORTANT WARNING!

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 6K Puller (M6K-M)

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Further technical information is available on

COOPER POWER SERIES. Under-oil arrester disconnector installation/operation instructions. OEM Equipment MN800010EN

Budget Range Operators Handbook

AIR CONDITIONERS WA14**W SERIES

G96 Series BASOTROL Dual Operator Valve

Operating Instructions Part No

ATS430 turbidity sensor Retractable insertion assembly

Safety Powder Spray Systems

400C & 450C DUAL PERFORMANCE VALUE PACKS

Instruction Manual. Digital Thermocouple Gauge Control Units Models DTC & DTC Models DTC-06M-115 & DTC-06M-230

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

Pressure Dump Valve Service Kit for Series 2300 Units

Pressure Relief Valve Instruction Manual

S Surge Arresters

Transcription:

32LT900301 32LT900611 32LT901247 32LT901647 SMALL ROOFTOP S ACCESSORY MOTORMASTERR I HEAD PRESSURE CONTROLLER 3to10TONS Installation Instructions TABLE OF CONTENTS PACKAGE CONTENTS... 1 PACKAGE USAGE- CARRIER AND BRYANT... 1 SAFETY CONSIDERATIONS... 2 GENERAL... 2 INSTALLATION... 2 CONTROLLER MOUNTING TEMPLATE... 17 ICP SPECIFIC MODELS... 18 IMPORTANT: Read these instructions completely before attempting to install this accessory. PACKAGE CONTENTS QTY CONTENTS 1 Motormaster I Controller 4 No. 10 Sheet metal screws 4 Star lockwashers 2 3/4- in. Lg 4-40 screws 2 Plate washers 2 4-40 Nuts 2 Wirenuts 1 Sensor Assembly NOTE: The 32LT900301 Motormaster I device is rated at 8 amps, and the 32LT900611 Motormaster I device is rated 4 amps. Table 2 Package Usage S VOLTAGE MOTOR CAPACITOR MM CONTROLLER 48/50HC*04, 50HCQ04, 48/50KC04, 50KCQA04, 581J/551J04, 549J04, 559J04, 582J04, 547J*04 48/50HC*05-06, 50HCQ05-06, 48/50KC05-06, 50KCQA05-06, 50TCQA05-06, 04-06 547J*05*- 06, 559J*05-06,, 582J*05-06, 04-06 50TCQA07, 07, 07, 548J07 50TCQA07,07, 07, 548J07 50TCQA07, 07, 07, 548J07 48/50HC*07-09, 50HCQ07-09, 50TCQD08-09 548J08-09, 549J07-09, 581J/551J- 07-09 08-12,08-12 (Single Compressor Units) 08-12,08-12 (Dual Compressor Units with Novation coil) 208/230-1- 60 208/230-3- 60 575-3- 60* HC38GE231 Keep Factory Installed 32LT900301 460-3-60 HC36GE461 Keep Factory Installed 32LT900611 208/230-1- 60 HC40GE233 See Table 2 32LT900301 208/230-3- 60 575-3- 60* HC40GE233 Replace with HC91CL010 32LT900301 460-3-60 HC40GE463 Replace with HC91CL010 32LT900611 208/230-3- 60 HC40GE233 Keep Factory Installed 32LT900301 460-3-60 HC40GE463 Replace with HC91CL010 32LT900611 575-3- 60* HC40GE233 Replace with HC91CL010 32LT900301 208/230-3- 60 (2) HC40GE233 Keep Factory Installed 32LT900301 460-3-60 (2) HC40GE463 Keep Factory Installed 32LT900611 575-3- 60** (2) HC40GE233 Replace with HC93CA013 32LT900301 208/230-3- 60 575-3- 60** (2) HC40GE233 Replace with HC93CA013 32LT900301 460-3-60 (2) HC40GE463 Replace with HC93CA013 32LT900611 208/230-3- 60 575-3- 60** (2) HC40GE233 Keep Factory Installed 32LT901247 460-3-60 (2) HC40GE463 Keep Factory Installed 32LT901647 The capacitor straps in the unit can be reused. If needed part numbers are as follows: HC91CL005 and HC91CL010 use HC98ZY071, and HC93CA013 uses 50DK507522 * Transformer HT01AH856 (0.75kva, 575v to 230v) and transformer bracket 50DK502263 are recommended. ** Transformer HT01AH859 (1kva, 575v to 230v) and transformer bracket 50DK502263 are recommended. *** Relay HN61KK066 is recommended to bypass Motormaster in Heat mode.

S 48/50HC*04-09, 50HCQ04-09, 48/50KC04, 581J/551J04-09, 548J04-09, 582J/559J04 48/50HC*04-09, 50HCQ04-09, 581J/551J04-09, 548J04-09 48/50KC04, 50KCQA04, 04 559J, 582J, 547J*04,,04 48/50KC05, 05, 50TCQA05 559J, 582J, 547J*05,, 05 48/50KC06, 06, 50TCQA06 559J, 582J, 547J*06,, 06 Table 1 - Package Usage(Cont) Unit Capacitor Replacement DUAL MFD* PART 10 HC91CL010 10 + 10 HC93CA013 45 + 10 HC98JA048 70 + 10 HC98JA073 80 + 10 HC98JA083 *Compressor shares capacitor with the OD motor. The first number is for compressors and the second number is for OD motors. SAFETY CONSIDERATIONS Installation and servicing of air- conditioning equipment can be hazardous due to system pressure and electrical components. Only trained and qualified service personnel should install, repair, or service air-conditioning equipment. Untrained personnel can perform the basic maintenance functions. All other operations should be performed by trained service personnel. When working on air-conditioning equipment, observe precautions in the literature, tags and labels attached to the unit, and other safety precautions that may apply. Follow all safety codes. Wear safety glasses and work gloves. Recognize safety information. This is the safety-alert symbol. When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING, and CAUTION. These words are used with the safety- alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies a hazard which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation. GENERAL Motormaster I solid- state head pressure control regulates fan speed. A temperature sensor, mounted on a return bend of the condenser (outdoor) coil, activates the device. The Motormaster I controller controls the speed of approved condenser (outdoor) fan motors in order to maintain a constant head pressure in the condenser (outdoor) coil. When properly installed, the control will maintain the appropriate head pressure at low ambient temperatures down to - 20_F. Usage is shown in Package Usage table. 2 INSTALLATION 1. Disconnect power to the unit. 2. Disconnect condenser (outdoor) fan motor (OFM) wires at the contactor and capacitor. Note position offanbladesinrelationtofanorifice. 3. Remove OFM(s) from the unit. 4. Remove fan blade(s) from motor(s). 5. Mount Motormaster I controller on the unit. (See Fig. 1.) The controller must be mounted vertically with leads at the bottom. Using the template supplied with the controller, drill 4 mounting holes. To ensure electrical ground, insert star lockwashers (supplied with the controller) under the heads of the sheet metal screws. 6. Route sensor wire from bottom of Motormaster I control to sensor location as specified in Fig. 2-5. Fasten sensor with 3/4-in. 4-40 screws, plate washers, and 4-40 nuts provided.! CAUTION PERSONAL INJURY HAZARD Failure to follow this caution may result in personal injury. Sensor assembly is delicate. Handle with care. 7. Replace the OFM(s), if required, with the motor(s) shown in Table 1. Rewire the motor connections as shown in Fig. 7-17. Two wirenuts are included in package, if needed. NOTE: In some cases the OFM change out also requires the capacitor it uses to change. Refer to PACKAGE USAGE tables to determine if the capacitor needs to be changed and what one is needed. The capacitor straps in the unit can be reused. If needed though, the part numbers are as follows: HC91CL005 and HC91CL010 use HC98ZY071, and HC93CA013 uses 50DK507522. Some single phase units have dual capacitors used for the OFM and the compressors. The Package Usage table specifically covers this. 8. Disconnect the wires at the capacitor making sure to note where each one was connected. Unscrew the capacitor strap carefully so it can be reused. Remove the capacitor and store in a safe place or discard properly. Using the capacitor strap, safely secure the new correct capacitor in the same location the old one was. Connect the wires the same way they were disconnected. 9. Coil up all excess wire and secure it next to the controller.

10. Winter start control a. R- 410A Units A winter start kit is required for R- 410A air conditioning units when using accessory Motormaster. 11. Wind baffles are required to prevent wind cross currents from causing abnormally low condensing temperatures. Fabricate sheet metal baffles as shown in Fig. 18-19. Use 20- gauge sheet metal. 12. Re- install fan blade. Ensure that fan blade is properly located in the orifice. Refer to the base unit installation instructions for further details. 13. Reconnect power to the unit. CONDENSER OIL BULKHEAD COMPRESSORS MOTORMASTER I CONTROLLER 7.5-10 Ton Electric Heat and Heat Pump Units without Single Point Box C08424 CONDENSER OIL 7.5-10 Ton Gas Units C08421 3-6 Ton Electric Heat and Heat Pump Units without Single Point Box C08425 MOTORMASTER I CONTROLLER BULKHEAD COMPRESSORS SINGLE POINT BOX 7.5-10 Ton Electric Heat and Heat Pump Units with Single Point Box C08422 3-6 Ton Electric Heat and Heat Pump Units with Single Point Box C08586 3-6 Ton Gas Units C08423 Fig. 1 - Motormasterr I Controller Locations 3

48/50KC04, 04 580/04, 582/559J04 48/50HC04 581/551J04 48/50KC05, 05 and 06, 582/559J05 /05 and 06 48/50HC05 and 06 48/50KC06 581/551J05 and 06, 582/559J06 07 /07 Fig. 2 - Motormaster I Sensor Mounting Locations 3-6 Ton Gas and Electric Heat Units 4

08 580/08 09-12 580/09-12 (Single Compressor Units) Fig. 3 - Motormaster I Sensor Mounting Locations 7.5-10 Ton Gas and Electric Heat Units 5

Sensor Location 50HCQ04, 50KCQ04 547J04, 549J04 50TCQ04, 548J04 50HCQ05 and 06, 50KCQ05 and 06 547J05 and 06, 549J05 and 06 Fig. 4 - Motormaster I Sensor Mounting Locations 3-6 Ton Heat Pump Units 6

Sensor Location Sensor Location Sensor Location 50TCQ05, 548J05 50TCQ06, 548J06 50TCQ07, 548J06 Sensor Location 50TCQ08 and 09, 548J08 and 09 Fig. 5 - Motormaster I Sensor Mounting Locations 7.5-10 Ton Heat Pump Units 7

-D08 and 580/08 -D12 and 580/12 Fig. 6 - *D08- D12 Outdoor Circuiting (Novation) MCHX C09567 8

Fig. 7 - Wiring Details - 208/230v Single Phase 3 to 5 Ton Gas and Electric Heat Units C08372 Fig. 10 - Wiring Details - 208/230v Three Phase 3to6TonHeatPumpUnits C08375 Fig. 8 - Wiring Details - 208/230v Single Phase 3to5TonHeatPumpUnits C08373 Fig. 9 - Wiring Details - 208/230v and 460v Three Phase 3 to 6 Ton Gas and Electric Heat Units C08374 Fig. 11 - Wiring Details - 460v Three Phase 3to6TonHeatPumpUnits C08377 Fig. 12 - Wiring Details - 575v Three Phase 3 to 6 Ton Gas and Electric Heat Units C08380 9

Fig. 13 - Wiring Details - 575v Three Phase 3to6TonHeatPumpUnits C08618 Fig. 16 - Wiring Details - 575v Three Phase 7.5 to 10 Ton Gas and Electric Heat Units C08381 C08378 Fig. 14 - Wiring Details - 208/230/460v Three Phase 7.5 to 10 Ton Gas and Electric Heat Units Fig. 17 - Wiring Details - 575v Three Phase 7.5to10TonHeatPumpUnits C08382 C08379 Fig. 15 - Wiring Details - 208/230/460v Three Phase 7.5to10TonHeatPumpUnits 10

Fig. 18 - Wind Baffles - 3 to 6 Ton Units C08601 Table 2 Wind Baffle Details - 3 to 6 Ton Unit DIMENSIONS (IN.) FRONT BAFFLE (IN.) 04 25 25 1/ 2 26 27 1/4 4 1/4 11 1/4 18 1/4 25 1/4 N/A 05 28 5 /8 29 1/8 29 5/8 27 1/4 4 1/4 11 1/4 18 1/4 25 1/4 N/A 06 28 5/ 8 29 1/8 29 5/8 27 1/4 4 1/4 11 1/4 18 1/4 25 1/4 N/A 07 28 5 / 8 29 1/8 29 5/8 35 3/8 4 1/4 11 1/4 18 1/4 25 1/4 32 1/4 SIDE BAFFLE (IN.) 04 20 7/8 21 3/8 21 7/8 27 1/4 4 1/4 11 1/4 18 1/4 25 1/4 N/A 05 20 7/8 21 3/8 21 7/8 27 1/4 4 1/4 11 1/4 18 1/4 25 1/4 N/A 06 20 7/8 21 3/8 21 7/8 27 1/4 4 1/4 11 1/4 18 1/4 25 1/4 N/A 07 20 7/8 21 3/8 21 7/8 35 3/8 4 1/4 11 1/4 18 1/4 25 1/4 32 1/4 11

Table 2 Wind Baffle Details - 3 to 6 Ton Unit (Continued) DIMENSIONS (IN.) FRONT BAFFLE (IN.) 48/50KC, 582J, 559J 04 28 5/8 29 1/8 29 5/8 27 1/4 41/4 11 1/4 18 1/4 25 1/4 N/A 05 48/50KC, 582J, 559J 3Phase 28 5/8 29 1/8 29 5/8 27 1/4 41/4 11 1/4 18 1/4 25 1/4 N/A 05 48/50KC, 582J, 559J 1Phase 25 25 1/2 26 27 1/4 41/4 11 1/4 18 1/4 25 1/4 N/A 06 48/50KC, 582J, 559J 3Phase 25 25 1/2 26 35 3/8 41/4 11 1/4 18 1/4 25 1/4 32 1/4 06 48/50KC, 582J, 559J 1Phase 28 5/8 29 1/8 29 5/8 35 3/8 41/4 11 1/4 18 1/4 25 1/4 32 1/4 SIDE BAFFLE (IN.) 48/50KC, 582J, 559J 04 20 7/8 21 3/8 21 7/8 27 1/4 41/4 11 1/4 18 1/4 25 1/4 N/A 05 48/50KC, 582J, 559J 3Phase 20 7/8 21 3/8 21 7/8 27 1/4 41/4 11 1/4 18 1/4 25 1/4 N/A 05 48/50KC, 582J, 559J 1Phase 20 7/8 21 3/8 21 7/8 27 1/4 41/4 11 1/4 18 1/4 25 1/4 N/A 06 48/50KC, 582J, 559J 3Phase 20 7/8 21 3/8 21 7/8 35 3/8 41/4 11 1/4 18 1/4 25 1/4 32 1/4 06 48/50KC, 582J, 559J 1Phase 20 7/8 21 3/8 21 7/8 35 3/8 41/4 11 1/4 18 1/4 25 1/4 32 1/4 BACK BAFFLE (IN.) 50KCQ 04 20 7/8 21 3/8 21 7/8 27 1/4 41/4 11 1/4 18 1/4 25 1/4 N/A 50KCQ 05 20 7/8 21 3/8 21 7/8 35 3/8 41/4 11 1/4 18 1/4 25 1/4 N/A 50KCQ 06 20 7/8 21 3/8 21 7/8 35 3/8 41/4 11 1/4 18 1/4 25 1/4 N/A LEFT BAFFLE (IN.) 50KCQ 04 28 5/8 29 1/8 29 5/8 27 1/4 41/4 11 1/4 18 1/4 25 1/4 N/A 50KCQ 05 28 5/8 29 1/8 29 5/8 35 3/8 41/4 11 1/4 18 1/4 25 1/4 32 1/4 50KCQ 06 28 5/8 29 1/8 29 5/8 35 3/8 41/4 11 1/4 18 1/4 25 1/4 32 1/4 BACK BAFFLE (IN.) K 04 N/A N/A N/A N/A N/A N/A N/A N/A 50TCQ 05 N/A N/A N/A N/A N/A N/A N/A N/A 06 N/A N/A N/A N/A N/A N/A N/A N/A 07 20 7/8 21 3/8 21 7/8 35 3/8 41/4 11 1/4 18 1/4 25 1/4 LEFT BAFFLE (IN.) K 04 25 25 1/2 26 27 1/4 41/4 11 1/4 18 1/4 25 1/4 50TCQ 05 28 5/8 29 1/8 29 5/8 27 1/4 41/4 11 1/4 18 1/4 25 1/4 06 25 25 1/2 26 35 3/8 41/4 11 1/4 18 1/4 25 1/4 32 1/4 07 28 5/8 29 1/8 29 5/8 35 3/8 41/4 11 1/4 18 1/4 25 1/4 32 1/4 12

Table 2 Wind Baffle Details - 3 to 6 Ton Unit (Continued) DIMENSIONS (mm) FRONT BAFFLE (mm) 04 635.0 647.7 660.4 108.0 108.0 285.8 463.6 641.4 N/A 05 727.1 739.8 752.5 108.0 108.0 285.8 463.6 641.4 N/A 06 727.1 739.8 752.5 108.0 108.0 285.8 463.6 641.4 N/A 07 727.1 739.8 752.5 904.9 108.0 285.8 463.6 641.4 819.2 SIDE BAFFLE (mm) 04 530.2 549.3 555.6 108.0 108.0 285.8 463.6 641.4 N/A 05 530.2 549.3 555.6 108.0 108.0 285.8 463.6 641.4 N/A 06 530.2 549.3 555.6 108.0 108.0 285.8 463.6 641.4 N/A 07 530.2 549.3 555.6 904.9 108.0 285.8 463.6 641.4 819.2 FRONT BAFFLE (mm) 48/50KC, 582J, 559J 04 727.1 739.8 752.5 692.2 108.0 285.8 463.6 641.4 N/A 05 48/50KC, 582J, 559J 3Phase 635.0 739.8 752.5 692.2 108.0 285.8 463.6 641.4 N/A 05 48/50KC, 582J, 559J 1Phase 635.0 647.7 660.4 692.2 108.0 285.8 463.6 641.4 N/A 06 48/50KC, 582J, 559J 3Phase 635.0 647.7 660.4 904.9 108.0 285.8 463.6 641.4 819.2 06 48/50KC, 582J, 559J 1Phase 635.0 739.8 752.5 904.9 108.0 285.8 463.6 641.4 819.2 SIDE BAFFLE (mm) 48/50KC, 582J, 559J 04 530.2 549.3 555.6 692.2 108.0 285.8 463.6 641.4 N/A 05 48/50KC, 582J, 559J 3Phase 530.2 549.3 555.6 692.2 108.0 285.8 463.6 641.4 N/A 05 48/50KC, 582J, 559J 1Phase 530.2 549.3 555.6 692.2 108.0 285.8 463.6 641.4 N/A 06 48/50KC, 582J, 559J 3Phase 530.2 549.3 555.6 904.9 108.0 285.8 463.6 641.4 819.2 06 48/50KC, 582J, 559J 1Phase 530.2 549.3 555.6 904.9 108.0 285.8 463.6 641.4 819.2 BACK BAFFLE (mm) 50KCQ 04 530.2 549.3 555.6 692.2 108.0 285.8 463.6 641.4 N/A 50KCQ 05 530.2 549.3 555.6 904.9 108.0 285.8 463.6 641.4 N/A 50KCQ 06 530.2 549.3 555.6 904.9 108.0 285.8 463.6 641.4 N/A LEFT BAFFLE (mm) 50KCQ 04 635.0 739.8 752.5 692.2 108.0 285.8 463.6 641.4 N/A 50KCQ 05 635.0 739.8 752.5 904.9 108.0 285.8 463.6 641.4 819.2 50KCQ 06 635.0 739.8 752.5 904.9 108.0 285.8 463.6 641.4 819.2 13

Table 2 Wind Baffle Details - 3 to 6 Ton Unit (Continued) DIMENSIONS (mm) BACK BAFFLE (mm) K 04 N/A N/A N/A N/A N/A N/A N/A N/A 50TCQ 05 N/A N/A N/A N/A N/A N/A N/A N/A 06 N/A N/A N/A N/A N/A N/A N/A N/A 07 530.2 549.3 555.6 904.9 108.0 285.8 463.6 641.4 LEFT BAFFLE (mm) K 04 635.0 647.7 660.4 692.2 108.0 285.8 463.6 641.4 50TCQ 05 727.1 739.8 752.5 692.2 108.0 285.8 463.6 641.4 06 635.0 647.7 660.4 904.9 108.0 285.8 463.6 641.4 819.2 07 727.1 739.8 752.5 904.9 108.0 285.8 463.6 641.4 819.2 14

Fig. 19 - Wind Baffles - 7.5 to 10 Ton Units C08602 Table 2 Wind Baffle Details - 7.5 to 10 Ton Units DIMENSIONS (IN.),,,,,,,,,,,, FRONT BAFFLE (IN.) K 08 40 5/8 41 1/8 41 5/8 35 3/8 1 1/4 9 1/4 17 1/4 25 1/4 33 1/4 N/A 09 28 5/8 29 1/8 29 5/8 43 3/8 1 1/4 9 1/4 17 1/4 25 1/4 33 1/4 41 1/4 12 40 5/8 41 1/8 41 5/8 43 3/8 1 1/4 9 1/4 17 1/4 25 1/4 33 1/4 41 1/4 SIDE BAFFLE (IN.) K 08 40 7/8 41 3/8 41 7/8 35 3/8 4 1/4 11 1/4 18 1/4 25 1/4 32 1/4 N/A 09 40 7/8 41 3/8 41 7/8 43 3/8 4 1/4 11 1/4 18 1/4 25 1/4 32 1/4 39 3/16 12 40 7/8 41 3/8 41 7/8 43 3/8 4 1/4 11 1/4 18 1/4 25 1/4 32 1/4 39 3/16 ) BACK BAFFLE (IN.) K 08 40 7/8 41 3/8 41 7/8 43 3/8 41/4 11 1/4 18 1/4 25 1/4 32 1/4 39 3/16 50TCQ 09 40 7/8 41 3/8 41 7/8 43 3/8 41/4 11 1/4 18 1/4 25 1/4 32 1/4 39 3/16 12 40 7/8 41 3/8 41 7/8 43 3/8 41/4 11 1/4 18 1/4 25 1/4 32 1/4 39 3/16 LEFT BAFFLE (IN.) K 08 40 5/8 41 1/8 41 5/8 43 3/8 11/4 91/4 17 1/4 25 1/4 33 1/4 41 1/4 50TCQ 09 40 5/8 41 1/8 41 5/8 43 3/8 11/4 91/4 17 1/4 25 1/4 33 1/4 41 1/4 12 40 5/8 41 1/8 41 5/8 43 3/8 11/4 91/4 17 1/4 25 1/4 33 1/4 41 1/4 15

Table 2 Wind Baffle Details - 7.5 to 10 Ton Units (Continued) DIMENSIONS (mm),,,,,,,,,, FRONT BAFFLE (mm) K 08 1031.9 1044.6 1057.3 904.9 31.8 235.0 438.2 641.4 844.6 N/A 09 727.1 739.8 752.5 1108.1 31.8 235.0 438.2 641.4 844.6 1047.8 12 1031.9 1044.6 1057.3 1108.1 31.8 235.0 438.2 641.4 844.6 1047.8 SIDE BAFFLE (mm) K 08 1038.2 1057.3 1063.6 904.9 108.0 285.8 463.6 641.4 819.2 N/A 09 1038.2 1057.3 1063.6 1108.1 108.0 285.8 463.6 641.4 819.2 995.4 12 1038.2 1057.3 1063.6 1108.1 108.0 285.8 463.6 641.4 819.2 995.4 BACK BAFFLE (mm) K 08 1038.2 1057.3 1063.6 1108.1 108.0 285.8 463.6 641.4 819.2 (995.4 50TCQ 09 1038.2 1057.3 1063.6 1108.1 108.0 285.8 463.6 641.4 819.2 995.4 12 1038.2 1057.3 1063.6 1108.1 108.0 285.8 463.6 641.4 819.2 995.4 LEFT BAFFLE (mm) K 08 1031.9 1044.6 1057.3 1108.1 31.8 235.0 438.2 641.4 844.6 1047.8 50TCQ 09 1031.9 1044.6 1057.3 1108.1 31.8 235.0 438.2 641.4 844.6 1047.8 12 1031.9 1044.6 1057.3 1108.1 31.8 235.0 438.2 641.4 844.6 1047.8 16

CONTROLLER MOUNTING TEMPLATE 17

ICP SPECIFIC MODELS PACKAGE USAGE- ICP S VOLTAGE MOTOR CAPACITOR MM CONTROLLER 208/230-1- 60 208/230-3- 60 HC38GE231 Keep Factory,, RHX036 575-3- 60* Installed 32LT900301 460-3-60 HC36GE461 Keep Factory Installed 32LT900611 208/230-1- 60 HC40GE233 See table 2 32LT900301 /036-060,,, RHX048,,, 208/230-3- 60 HC40GE233 Replace with 32LT900301 RHX060 575-3- 60* HC91CL010 460-3-60 HC40GE463 Replace with 32LT900611 HC91CL010 072, 072 208/230-3- 60 HC40GE233 Keep Factory Installed 32LT900301 072, 072 460-3-60 HC40GE463 Replace with HC91CL010 32LT900611 072, 072 575-3- 60* HC40GE233 Replace with HC91CL010 32LT900301 208/230-3- 60 (2) HC40GE233 Replace with 090-120, 090-120 575-3- 60** HC93CA013 32LT900301 (Single Compressor Units) 460-3-60 (2) HC40GE463 Replace with HC93CA013 32LT900611 The capacitor straps in the unit can be reused. If needed part numbers are as follows: HC91CL005 and HC91CL010 use HC98ZY071, and HC93CA013 uses 50DK507522 * Transformer HT01AH856 (0.75kva, 575v to 230v) and transformer bracket 50DK502263 are recommended. ** Transformer HT01AH859 (1kva, 575v to 230v) and transformer bracket 50DK502263 are recommended. *** Relay HN61KK066 is recommended to bypass Motormaster in Heat mode. Unit Capacitor Replacement S DUAL MFD* PART RGH/RAH036-102, RHH036-102, /036 10 HC91CL010 RGH/RAH036-102, RHH036-102 10 + 10 HC93CA013 /036, RHX036, /036 45 + 10 HC98JA048 /048, /048, RHS048 70 + 10 HC98JA073 /060, /060, RHS060 80 + 10 HC98JA083 *Compressor shares capacitor with the OD motor. The first number is for compressors and the second number is for OD motors. 18

/036, /036 /048 /048 & 060 /072 /060 Fig. 20 - Motormaster I Sensor Mounting Locations 3-6 Ton Gas and Electric Heat Units /091 /101-121 Fig. 21 - Motormaster I Sensor Mounting Locations 7.5-10 Ton Gas and Electric Heat Units 19

RHX036 RHX048, RHX060 Fig. 22 - Motormaster I Sensor Mounting Locations 2-6 Ton Heat Pump Units 20

Fig. 23 - Wind Baffles - 3 to 6 Ton Units C08601 Table 3 Wind Baffle Details - 3 to 6 Ton Unit DIMENSIONS (IN.) FRONT BAFFLE (IN.) 036 25 25 1/ 2 26 27 1/4 4 1/4 11 1/4 18 1/4 25 1/4 N/A 048 28 5 /8 29 1/8 29 5/8 27 1/4 4 1/4 11 1/4 18 1/4 25 1/4 N/A 060 28 5/ 8 29 1/8 29 5/8 27 1/4 4 1/4 11 1/4 18 1/4 25 1/4 N/A 072 28 5 / 8 29 1/8 29 5/8 35 3/8 4 1/4 11 1/4 18 1/4 25 1/4 32 1/4 SIDE BAFFLE (IN.) 036 20 7/8 21 3/8 21 7/8 27 1/4 4 1/4 11 1/4 18 1/4 25 1/4 N/A 048 20 7/8 21 3/8 21 7/8 27 1/4 4 1/4 11 1/4 18 1/4 25 1/4 N/A 060 20 7/8 21 3/8 21 7/8 27 1/4 4 1/4 11 1/4 18 1/4 25 1/4 N/A 072 20 7/8 21 3/8 21 7/8 35 3/8 4 1/4 11 1/4 18 1/4 25 1/4 32 1/4 21

Table 3 Wind Baffle Details - 2 to 6 Ton Unit (Continued) DIMENSIONS (IN.) FRONT BAFFLE (IN.) 036 28 5/8 29 1/8 29 5/8 27 1/4 4 1/4 11 1/4 18 1/4 25 1/4 N/A 048 3Phase 048 1Phase 060 3Phase 060 1Phase 28 5/8 29 1/8 29 5/8 27 1/4 41/4 11 1/4 18 1/4 25 1/4 N/A 25 25 1/2 26 27 1/4 4 1/4 11 1/4 18 1/4 25 1/4 N/A 25 25 1/2 26 35 3/8 4 1/4 11 1/4 18 1/4 25 1/4 32 1/4 28 5/8 29 1/8 29 5/8 35 3/8 41/4 11 1/4 18 1/4 25 1/4 32 1/4 SIDE BAFFLE (IN.) 036 20 7/8 21 3/8 21 7/8 27 1/4 4 1/4 11 1/4 18 1/4 25 1/4 N/A 048 3Phase 048 1Phase 060 3Phase 060 1Phase 20 7/8 21 3/8 21 7/8 27 1/4 41/4 11 1/4 18 1/4 25 1/4 N/A 20 7/8 21 3/8 21 7/8 27 1/4 41/4 11 1/4 18 1/4 25 1/4 N/A 20 7/8 21 3/8 21 7/8 35 3/8 41/4 11 1/4 18 1/4 25 1/4 32 1/4 20 7/8 21 3/8 21 7/8 35 3/8 41/4 11 1/4 18 1/4 25 1/4 32 1/4 22

Table 3 Wind Baffle Details - 3 to 6 Ton Unit (Continued) DIMENSIONS (mm) FRONT BAFFLE (mm) 036 635.0 647.7 660.4 108.0 108.0 285.8 463.6 641.4 N/A 048 727.1 739.8 752.5 108.0 108.0 285.8 463.6 641.4 N/A 060 727.1 739.8 752.5 108.0 108.0 285.8 463.6 641.4 N/A 072 727.1 739.8 752.5 904.9 108.0 285.8 463.6 641.4 819.2 SIDE BAFFLE (mm) 036 530.2 549.3 555.6 108.0 108.0 285.8 463.6 641.4 N/A 048 530.2 549.3 555.6 108.0 108.0 285.8 463.6 641.4 N/A 060 530.2 549.3 555.6 108.0 108.0 285.8 463.6 641.4 N/A 072 530.2 549.3 555.6 904.9 108.0 285.8 463.6 641.4 819.2 FRONT BAFFLE INCHES (mm) 036 727.1 739.8 752.5 692.2 108.0 285.8 463.6 641.4 N/A 048 3Phase 048 1Phase 060 3Phase 060 1Phase 635.0 739.8 752.5 692.2 108.0 285.8 463.6 641.4 N/A 635.0 647.7 660.4 692.2 108.0 285.8 463.6 641.4 N/A 635.0 647.7 660.4 904.9 108.0 285.8 463.6 641.4 819.2 635.0 739.8 752.5 904.9 108.0 285.8 463.6 641.4 819.2 SIDE BAFFLE INCHES (mm) 036 530.2 549.3 555.6 692.2 108.0 285.8 463.6 641.4 N/A 048 3Phase 048 1Phase 060 3Phase 060 1Phase 530.2 549.3 555.6 692.2 108.0 285.8 463.6 641.4 N/A 530.2 549.3 555.6 692.2 108.0 285.8 463.6 641.4 N/A 530.2 549.3 555.6 904.9 108.0 285.8 463.6 641.4 819.2 530.2 549.3 555.6 904.9 108.0 285.8 463.6 641.4 819.2 23

Fig. 24 - Wind Baffles - 7.5 to 10 Ton Units C08602 Table 4 Wind Baffle Details - 7.5 to 10 Ton Units DIMENSIONS (IN.) FRONT BAFFLE (IN.) K 091 40 5/8 41 1/8 41 5/8 35 3/8 1 1/4 9 1/4 17 1/4 25 1/4 33 1/4 N/A 101 28 5/8 29 1/8 29 5/8 43 3/8 1 1/4 9 1/4 17 1/4 25 1/4 33 1/4 41 1/4 121 40 5/8 41 1/8 41 5/8 43 3/8 1 1/4 9 1/4 17 1/4 25 1/4 33 1/4 41 1/4 SIDE BAFFLE (IN.) K 091 40 7/8 41 3/8 41 7/8 35 3/8 4 1/4 11 1/4 18 1/4 25 1/4 32 1/4 N/A 101 40 7/8 41 3/8 41 7/8 43 3/8 4 1/4 11 1/4 18 1/4 25 1/4 32 1/4 39 3/16 121 40 7/8 41 3/8 41 7/8 43 3/8 4 1/4 11 1/4 18 1/4 25 1/4 32 1/4 39 3/16 DIMENSIONS (mm) FRONT BAFFLE (mm) K 091 1031.9 1044.6 1057.3 904.9 31.8 235.0 438.2 641.4 844.6 N/A 101 727.1 739.8 752.5 1108.1 31.8 235.0 438.2 641.4 844.6 1047.8 121 1031.9 1044.6 1057.3 1108.1 31.8 235.0 438.2 641.4 844.6 1047.8 SIDE BAFFLE (mm) K 091 1038.2 1057.3 1063.6 904.9 108.0 285.8 463.6 641.4 819.2 N/A 101 1038.2 1057.3 1063.6 1108.1 108.0 285.8 463.6 641.4 819.2 995.4 121 1038.2 1057.3 1063.6 1108.1 108.0 285.8 463.6 641.4 819.2 995.4 24

CONTROLLER MOUNTING TEMPLATE 25

Copyright 2014 CAC / BDP D 7310 W. Morris St. D Indianapolis, IN 46231 Edition Date: 11/14 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No:IIK- 32LT903-03 Replaces: IIK- 32LT903-02 26