Qi Litre Ultrasonic Cleaner

Similar documents
Ultrasonic baths. XUB range of digital ultrasonic baths. XUBA range of analogue ultrasonic baths. Digitally controlled range with a choice of 5 baths

Picus NxT Electronic Pipettes Ergonomic, Efficient, & Safe

The pipettes cover a volume range from 0.1µl to 10ml.

RayPette Plus Autoclavable Pipette. User Manual

Picus NxT Electronic Pipettes Ergonomic, Efficient, & Safe

VIAFLO 96. Electronic 96 Channel Hand Held Pipettor

MULTICHANNEL. Labnet International, Inc.

DISCOVERY PRO - features

Transferpette. Lightweight precise rugged reliable!

Transferpette. Lightweight precise rugged reliable!

Proline Plus Mechanical Pipette

Pipettor. User Manual

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

Chapter 2. Pipetting techniques. Guide to Pipetting

Improving Pipetting Techniques

The Univentor 1250 Anaesthesia Unit

Standard Operating Procedure. Air Displacement Pipette Calibration

Improve pipetting results in pharmaceutical formulation by using MICROMAN E

Adjust the Volume Display

Minipuls evolution fitted with three 4-channel Medium Flow pump heads. one 4-channel Medium Flow pump head and one 2-channel High Flow pump head

THE UNIVENTOR 400 ANAESTHESIA UNIT

Laboratory #2 Pipetting Technique and Micropipette Calibration Skills=40 pts

Fisherbrand. Finnpipette INSTRUCTIONS FOR USE PARK LANE Pittsburgh PA

Operating Instructions METTLER TOLEDO Pipette Check Application for AX and MX/UMX Balances Version 1.xx

Eurosonic 4D - 3D - Micro ENGLISH

Air Displacement Pipetting Modules. Total Integrated Liquid Handling

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

UNCC Biotechnology and Bioinformatics Camp. Dr. Jennifer Weller Summer 2010

Performance Verification of BioTek s Precision 2000 using Artel s Multichannel Volume Verification (MVV ) System

Selecting the right pressure sensor for your application

American Weigh Scales, Inc. BLADE Series D i g i t a l P o c k e t S c a l e BLADE-550. User Manual BLADE-400 BLADE-1000

NGN Series nitrogen generator

Hygea Ultrasonic Validation Kit

High-performance submersible pressure transmitter For level measurement Model LH-20

II. MATERIALS REQUIRED FOR PERFORMANCE TESTING

SonoMeter 30 Energy Meters

Tips for Proper Pipette handling and Maintenance. D. Muruganand, Ph.D ILQA - Bangalore, Feb 2014

Pneumatic high-pressure controller Model CPC7000

25/04/56. LTC Carmen A. Bell Chief, Laboratory Operations USAMC-AFRIMS

StockWeigh 500 D3632 US-B

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

SAUTER FK Version /2016 GB

Rotary Viscometers Rotary viscosimeters ST-2020

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

ali-q TM Gravimetric Verification Procedure

VWR UHP j :01 Page 1. ENGLISH 1 22 DEUTSCH FRANÇAIS ESPAπOL ITALIANO

AUTOMATIC HOSE TEST UNIT, TYPE SPU

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

G4S G4A1KY RESIDENTIAL CONVERSION KIT LOW PRESSURE CONVERSION KIT MEDIUM PRESSURE CONVERSION KIT HIGH PRESSURE CONVERSION KIT ULTRASONIC GAS METER

Integral type Differential pressure flowmeter VNT Series

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

Eliminating Sources of Pipetting Error in the Forensic Laboratory David M. Epstein Director of Scientific Operations. Abstract.

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

Pneumatic high-pressure controller Model CPC7000

Accelerated Corrosion Test Chambers

[Instruments for vacuum measurement, checking and adjustment] 3

GAS FILLING MACHINES PROCESS MONITORING PRESSURE BALANCE

PMI ADVANCED AUTOMATED HYDRAULIC PRESSURE LEAK TESTER APCS-H-60K. Not just Products... Solutions!

PIPETMAN F ENGLISH. Other languages available on our website:

Transferpette -8/-12

WHEATON. Peristaltic Pumps. Advancing the Science of Liquid Handling

Product instruction manual Easymount Sign Laminators EM-S1400C, EM-S1600C, EM-S1400H, EM-S1600H

MICROMAN ENGLISH. Other languages can be consulted and downloaded on our website,

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Transferpette. Single and Multichannel Pipettes

TH-1800-T TRX-700-CNG Converter

water purification cylinders & accessories

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Pneumatic dead-weight tester Model CPB3500

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Project Title: Pneumatic Exercise Machine

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

Easy to operate even for biginners. Set up the number of test. Possible to select from 1 to times

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

High-performance submersible pressure transmitter For level measurement Model LH-20

User s Manual. Autoclavable & UV resistant. Multi-channel digital micro pipette. In Vitro Medical Diagnostic Devices (98/79/EC)

Anesthesia Workstation

Register your instrument! Eppendorf Xplorer / Eppendorf Xplorer plus. Adjustment

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

628 Differential Pressure Decay Leak Tester

Improve Process Reliability

Instruction Manual Contact Pressure Vacuum Gauge

RH800 & 2000 BASIC OPERATIONS

SEIKO MULTI TIMING SYSTEMS

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

High-performance submersible pressure transmitter For level measurement Model LH-10

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

A hose layline contains important information for specifying the replacement assembly: manufacturer, hose trade name, working pressure and hose ID.

Technical Information Conducal CLY421

Multi Fibres. MiniFant M99 insulation blowing MacHinE

EEF. Fatigue Testing Unit PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Engineering and Technical Teaching Equipment

High Pressure Breathing Air Compressors

HI 2314 HI 2315 HI 23151

Additel 761 Automated Pressure Calibrators Selection Guide

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

Risk Services Best Practices Bulletin Food Preparation Presented by Office of the President Risk Services May 2012

ACTUATORS AND INSTRUMENTS

Transcription:

Qi-300 17Litre Ultrasonic Cleaner Ultrawave s Qi-Series are robust and reliable, delivering outstanding cleaning performance in a wide range of industries. From precision, pharmaceutical and medical device manufacturing to heavy duty cleaning in automotive and engineering processing. The 2mm thick stainless steel tank provides longevity and durability whilst excellent ultrasonic activity is generated via Ultrawave s Frequency Leap technology. Frequency Leap technology reduces dead spots and promotes homogenous cavitational activity within the tank. This provides a more consistent scrubbing action for highly effective cleaning results. The Qi-300 is a 17Litre ultrasonic cleaner with a menu driven, LCD control panel. This allows simple adjustment of cycle time (0 to 99mins or infinity mode), temperature (ambient to 80 C), ultrasonic power and frequency mode for precise and accurate processing. Incorporating features such as degas mode and a fluid level sensor, the Qi-Series is reliable and durable, giving you consistent cleaning results every time. Eastgate Business Park Tel: +44 (0) 845 330 4236 Wentloog Avenue Fax: +44 (0) 845 330 4231 Cardiff CF3 2EY Email: admin@ultrawave.co.uk United Kingdom Web: www.ultrawave.co.uk

Qi-300 17Litre Ultrasonic Cleaner Construction Case Construction Tank Front Panel Control Overall Dimensions Tank Dimensions Basket Dimensions Capacity Ultrasonic Power Ultrasonic Power (per Litre) Operating Frequency 304 Stainless Steel 316 Stainless Steel 304 Stainless Steel Digital LCD 400 x 460 x 420mm (WxDxH) 305 x 275 x 200mm (WxDxH) 275 x 250 x 125mm (WxDxH) 17Litres 300W 17W/Litre 32-38KHz Frequency Leap Maximum Heating Capacity Ambient - 80 C Heater Power Timer Mains Connection Drain Outlet Lid Basket Gross Weight (inc. lid, basket & packaging) Net Weight Warranty 750W 0-99 minutes or Infinity mode 220-240V (50-60Hz) ½ BSP VALVE Stainless Steel Stainless Steel 17KGs 14KGs 3 Years Eastgate Business Park Tel: +44 (0) 845 330 4236 Wentloog Avenue Fax: +44 (0) 845 330 4231 Cardiff CF3 2EY Email: admin@ultrawave.co.uk United Kingdom Web: www.ultrawave.co.uk

Single Channel Electronic Pipettes MPA Series MPA-10 MPA-200 MPA-20 MPA-1200 Accurate pipetting for everyone

If you still think manual pipettes are good enough, it s time to THINK AGAIN Now take a moment to consider the facts presented here. You will then realize why A&D s new and original electronic pipettes, the MPA series, should be your future choice in pipettes! Advantages of Using an Electronic Pipette High precision assured for everyone at all times Unlike the manual pipette, dispensed quantities will not vary with each individual, which makes the results of analyses always reliable. If necessary, you can concentrate on other tasks while leaving pipetting work to others. Reduced physical strain with light and short key strokes Have you ever suffered a repetitive strain injury (RSI) on the thumb after long hours of work with a manual pipette? The key operation of an electronic pipette requires the minimum amount of force, and keeps strain on your hand to the lowest degree possible. Compared with the manual pipette, the level of fatigue will be less than 1/100. 1 You can therefore avoid a decrease in efficiency due to fatigue as well as workplace injuries. Various useful pipetting modes 1 Calculation based on the pushing force required and distance displaced. Apart from normal automatic aspirating and dispensing (AUTO mode), the following functions help greatly reduce time, stress and error associated with certain pipetting tasks: Multiple dispensing (MD) mode The MD mode lets you dispense one aspirated volume (e.g. 1200 µl) by multiple installments of a smaller volume (e.g. 100 µl 12 times), which greatly helps when you need to repeatedly deliver the same amount of sample into a microplate, etc. The MPA series can automatically correct error in the first installment that is inherent in electronic pipettes, and thereby realize highly precise multiple dispensing. Mixing (MIX) mode In MIX mode the pipette executes a set number of aspirating-dispensing cycles to mix and homogenize the solution in the receiving vessel. With a manual pipette the same task will be very tiresome and also difficult to perform correctly when the mixing volume is small.

Reverse operation If reverse operation is selected, the pipette first aspirates a volume larger than the set dispensing volume, and discards the excess volume after delivery. This function is recommended for a viscous sample liquid that tends to linger in the tip. Unique Features of the MPA Series Easy calibration (adjustment) by yourself User CAL function It would be expensive and difficult to use an outside calibration service frequently, wouldn t it. With the MPA series, you will be able to easily ensure your pipette accuracy (and consequently the precision of your analyses) by performing calibration at your own location whenever you want. 2 3 This function can also correct error due to differences in tip characteristics, therefore allowing accurate pipetting with tips manufactured by other companies. 4 2 For verification of dispensed volumes necessary for calibration, A&D s pipette accuracy testers are useful (see A&D s pipette inspection devices on the back page). 3 A calibration report is provided for each unit at the time of shipping as well. 4 A list of compatible tips is available. Calibration and display in a unit of weight (mg) The MPA series enables you to calibrate and display the pipetting amount based on weight (mg) as well as volume (µl). Weight calibration using a balance This will make it easier for you to handle liquids that need to be managed by weight, such as a diluted solution of a solid or powder; and control more precisely the dispensing amounts of high-viscosity liquids, which are prone to error with normal volume calibration. Increased resistance to impacts from falls Did you know that one of the most common repairs of electronic pipettes is for a broken LCD panel due to dropping? With padding set on the four corners of the head, the LCD panel of the MPA series is designed to be protected from impacts from falls as much as possible. Impact-absorbing pads Operation (plunger) key User-friendly industrial design The movement of the plunger can be controlled with the ball of the index finger instead of the thumb, while maintaining all fingers in a natural, effortless grip.

Specifications Model Capacity range Performance 5 6 Volume Accuracy Repeatability (CV) Operation mode Program memory Aspirating/dispensing speed Pipette drive method Power saving function Maximum number of pipetting cycles Charging time AC adapter Autoclave treatment Operating environment Battery Length Weight (including the battery) 5 In standard mode with maximum aspirating and dispensing speeds 6 For the MPA-10, specifications apply for volumes of 1.0 µl or above Accessories / disposables AX-BOX10/20/200 Tip box for the MPA-10/20/200 7 AX-BOX1200 Tip box for the MPA-1200 7 AX-CART-10/20 Tip cartrige for the MPA-10/20 (10 tip sets) 8 AX-CART-200 Tip cartrige for the MPA-200 (10 tip sets) 8 AX-CART-1200 Tip cartrige for the MPA-1200 (10 tip sets) 8 7 Tips are not included 8 One tip set includes 96 tips MPA-10 0.5 to 10.0 µl 1.0 µl ±4.0% 2.5% 10.0 µl ±1.0% 0.4% MPA-20 2.0 to 20.0 µl 2.0 µl ±4.0% 2.5% MPA-200 10 to 200 µl Approx. 160 g MPA-1200 100 to 1200 µl Standard mode (AUTO), Multiple dispensing mode (MD), Mixing mode (MIX), System setting mode (SYS) 9 programs 5 speeds High precision stepping motor Automatic power off after 10 minutes of inactivity 1,800 (on a full charge) 5 Approx. 5 hours / 100% Input: AC 100 to 240V, Output: DC 5V / 1A, Plug shape: selectable Possible for the lower part of the pipette (121 C, 2 atm, 20 minutes) 15 to 30 C (59 to 86 F), 85%RH or less Lithium-ion battery 3.7V / 920 mah Approx. 280 mm Approx. 150 g 20.0 µl ±1.0% 0.4% 10 µl ±2.5% 1.0% 200 µl ±0.6% 0.15% 100 µl ±2.5% 0.6% 1200 µl ±0.5% 0.15% Approx. 170 g

Wolf Laboratories Limited www.wolflabs.co.uk Tel: 01759 301142 Fax:01759 301143 sales@wolflabs.co.uk Use the above details to contact us if this literature doesn't answer all your questions. Pricing on any accessories shown can be found by keying the part number into the search box on our website. The specifications listed in this brochure are subject to change by the manufacturer and therefore cannot be guaranteed to be correct. If there are aspects of the specification that must be guaranteed, please provide these to our sales team so that details can be confirmed.