An Assessment of Quality in Underwater Archaeological Surveys Using Tape Measurements

Similar documents
An assessment of quality in underwater archaeological surveys using tape measurements

Stadium Project - DP-70 Atlanta, GA, 9/30/2014

Sparse LBL aided INS for Subsea Positioning

THE APPLICATION OF THE FUSION POSITIONING SYSTEM TO MARINE ARCHAEOLOGY

PUBLISHED PROJECT REPORT PPR850. Optimisation of water flow depth for SCRIM. S Brittain, P Sanders and H Viner

Tutorial for the. Total Vertical Uncertainty Analysis Tool in NaviModel3

INTERNATIONAL HYDROGRAPHIC SURVEY STANDARDS

Surveying shipwrecks and tracking ROVs with the High Precision Acoustic Surveying System (HPASS)

S-44 edition 5 The IHO s New Standard For Hydrographic Surveys Chris Howlett Head of Seabed Data Centre United Kingdom Hydrographic Office

DQM Annual Hopper QA Checks

Wade Reynolds 1 Frank Young 1,2 Peter Gibbings 1,2. University of Southern Queensland Toowoomba 4350 AUSTRALIA

River Bridge - Test Shaft-1 Clarke County, MS, 4/2/2012

Surveying Fundamentals and Practices, 5/e

Cove Point Beach Restoration: Utilization of a Spawning Habitat by Horseshoe Crabs (Limulus polyphemus)

ATION TITLE. Survey QC, Decision Making, and a Modest Proposal for Error Models. Marc Willerth, MagVAR

Chapter 12 Practice Test

ROUNDABOUT CAPACITY: THE UK EMPIRICAL METHODOLOGY

Denise L Seman City of Youngstown

Investigating the effects of interchanging components used to perform ripple assessments on calibrated vector network analysers

14/10/2013' Bathymetric Survey. egm502 seafloor mapping

Is lung capacity affected by smoking, sport, height or gender. Table of contents

Surveying & Measurement. Distance Measurement

Technical Report. 5th Round Robin Test for Multi-Capillary Ventilation Calibration Standards (2016/2017)

Walk - Run Activity --An S and P Wave Travel Time Simulation ( S minus P Earthquake Location Method)

BOTTOM MAPPING WITH EM1002 /EM300 /TOPAS Calibration of the Simrad EM300 and EM1002 Multibeam Echo Sounders in the Langryggene calibration area.

Everything you need to know about flatteners and levelers for coil processing

Spatial Methods for Road Course Measurement

A statistical model of Boy Scout disc golf skills by Steve West December 17, 2006

MEMORANDUM. Investigation of Variability of Bourdon Gauge Sets in the Chemical Engineering Transport Laboratory

Products and Services HR3D, AUV3D

FIG: 27.1 Tool String

METHODS EMPLOYED IN LOCATING SOUNDINGS

Wind Flow Validation Summary

EEC 686/785 Modeling & Performance Evaluation of Computer Systems. Lecture 6. Wenbing Zhao. Department of Electrical and Computer Engineering

Outline. Terminology. EEC 686/785 Modeling & Performance Evaluation of Computer Systems. Lecture 6. Steps in Capacity Planning and Management

What Length Paddle Should I Use!! Surf Life Saving Australia Level 3 Coaching Research Assignment. June By Richard Duncan

Minimum depth, mean depth or something in between?

Hydrographic Surveying Methods, Applications and Uses

Row / Distance from centerline, m. Fan side Distance behind spreader, m 0.5. Reference point. Center line

Palythoa Abundance and Coverage in Relation to Depth

from ocean to cloud HEAVY DUTY PLOUGH PERFORMANCE IN VERY SOFT COHESIVE SEDIMENTS

THE WAVE CLIMATE IN THE BELGIAN COASTAL ZONE

Precision Liquid Settlement Array Manual

Section I: Multiple Choice Select the best answer for each problem.

Copy of my report. Why am I giving this talk. Overview. State highway network

DUXBURY WAVE MODELING STUDY

Comparison of flow models

WHAT CAN WE LEARN FROM COMPETITION ANALYSIS AT THE 1999 PAN PACIFIC SWIMMING CHAMPIONSHIPS?

Improving the Bus Network through Traffic Signalling. Henry Axon Transport for London

WIND DATA REPORT. Paxton, MA

Practice Test Unit 6B/11A/11B: Probability and Logic

Module 8 Coils and Threads

Chapter 8 Manual Depth Measurement Techniques

Correlation analysis between UK onshore and offshore wind speeds

Reliable, accurate groundwater Diver dataloggers and software. Diver-Suite

Validation of Measurements from a ZephIR Lidar

Practice Test Unit 06B 11A: Probability, Permutations and Combinations. Practice Test Unit 11B: Data Analysis

AIS data analysis for vessel behavior during strong currents and during encounters in the Botlek area in the Port of Rotterdam

CORESTA RECOMMENDED METHOD N 6

7 th International Conference on Wind Turbine Noise Rotterdam 2 nd to 5 th May 2017

FULL SCALE MEASUREMENT OF DYNAMIC SHIP MOTIONS AND SQUAT

Calculation of Trail Usage from Counter Data

Calculating Total Uncertainty of Temperature Calibration with a Dry Block. Calibration White Paper. Beamex.

Reliable, accurate groundwater Diver dataloggers and software. Diver-Suite

Dynamic Positioning Control Augmentation for Jack-up Vessels

Building an NFL performance metric

Minimal influence of wind and tidal height on underwater noise in Haro Strait

DX2/DXX Operating Instructions

Stat 139 Homework 3 Solutions, Spring 2015

BASELINE SURVEY, VISUAL - SITE SPECIFIC

INTERMEDIATE CASING SELECTION FOR COLLAPSE, BURST AND AXIAL DESIGN FACTOR LOADS EXERCISE

Diver-Suite. Reliable, accurate groundwater Diver dataloggers and software

Data Set 7: Bioerosion by Parrotfish Background volume of bites The question:

A PRACTICAL APPROACH TO QUALITY CONTROL AND QUALITY ANALYSIS OF DEPTH DATA

Calibration and Validation of the Shell Fatigue Model Using AC10 and AC14 Dense Graded Hot Mix Asphalt Fatigue Laboratory Data

WORLD SCIENTIFIC CONGRESS OF GOLF. ST. ANDREWS, SCOTLAND TH JULY 2002 SCIENCE AND GOLF IV PROCEEDINGS OF THE WORLD SCIENTIFIC CONGRESS OF GOLF

MAHS Field School 2018 Pickles Reef Florida Keys National Marine Sanctuary

A differerential pressure anemometer

Evaluation of the Klein HydroChart 3500 Interferometric Bathymetry Sonar for NOAA Sea Floor Mapping

OPERATIONS SEAFARER CERTIFICATION GUIDANCE NOTE SA MARITIME QUALIFICATIONS CODE. Deck: Chart Work

5.1 Introduction. Learning Objectives

Engineering Surveying - II CE313. Hydrographic Survey Lecture 06 Muhammad Noman

Laboratory Activity Measurement and Density. Average deviation = Sum of absolute values of all deviations Number of trials

Orthometric Height Determination Using GPS in East Antarctica

The Reliability of Intrinsic Batted Ball Statistics Appendix

A Method Quantitatively Evaluating on Technical Progress of Students in Ship Handling Simulator Training ABSTRACT

DISTANCE MEASUREMENT

THERMALLING TECHNIQUES. Preface

Cover Page for Lab Report Group Portion. Head Losses in Pipes

QUESTIONS and ANSWERS WHY TEST KONGSBERGS

Understanding How the Appearance of Optical Fiber Splices Relates to Splice Quality

Application of a New Method for Monitoring Lake Trout Abundance in Yukon: Summer Profundal Index Netting (SPIN)

Sandvik TIM3D Locked to target. Advanced navigation system for surface top hammer drilling

Quantitative Literacy: Thinking Between the Lines

Measurement and simulation of the flow field around a triangular lattice meteorological mast

DOE Golfer Experiment

Data Collection and Processing: Elwha Estuary Survey, February 2013

Vibration and Pulsation Analysis and Solutions

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

Product highlights Variable frequency and thrust

Transcription:

An Assessment of Quality in Underwater Archaeological Surveys Using Tape Measurements Peter Holt 3H Consulting Ltd, 6 Honcray, Oreston, Plymouth, Devon, PL9 9XB The quality of a typical underwater archaeological survey using 3D trilateration with fibreglass tape measures was established on an underwater test site. A precision of 25mm was calculated for tape measurements giving a position accuracy of 43mm. Of the 304 measurements that were made during the tests, 20% were found to be in error. Key words: Survey, quality, accuracy, trilateration Introduction The aim of this work was to determine the quality of a typical underwater archaeological survey using 3D trilateration with fibreglass tape measures. To achieve this we need to determine the accuracy, precision and reliability of the position of any point in the survey. The assessment of quality measures the sizes and nature of undetected errors that exist in computed positions. Three-dimensional trilateration was chosen for this test as the required quality information is produced as a by-product of processing the measurements. This form of trilateration is often called the 'Direct Survey Method' and was popularised in marine archaeology by Rule (Rule 1989). The methods used for processing distance measurements is similar to that used by Global Positioning System receivers (UKOOA 1994) and underwater acoustic positioning systems (Kelland 1994). Terminology Accuracy is considered to be an overall estimate of the errors present in measurements including systematic errors. Accurate measurements are those that are close to the true value. Where systematic errors have been removed accuracy is the same as precision. Precision is a term used to describe the quality of a position with respect to random errors. Thus a very precise position fix is one where the random errors are small. As the random errors cannot be determined, precision is usually measured by means of a standard deviation (S.D.). Standard Deviation is a measure of the spread of the random errors in any measurement, so the larger the S.D. the larger the random errors. Reliability is used to describe the quality of a position with respect to outliers (mistakes or blunders), so in a highly reliable position fix even quite small outliers will be detected. Precision of a position is determined by assessing the standard deviations of measurements used to calculate that position and computing their propagation through a best-fit process. The standard best-fit process is called least squares, this gives the most desirable result (one with the highest precision) and is very simple. (Cross 1981, Atkinson et al 1988, Bannister 1994, Uren 1985) Method To calculate the quality metrics we needed a sample data set of multiple sets of tape measurements made between a number of fixed and rigid points on a typical site underwater. No corrections were applied to the measurements for temperature, sag or tension so the results would be close to those achieved on a typical underwater site.

As a suitable site was not available a test site was set up at the base of the Fort behind the Breakwater in Plymouth Sound. This site was used by the Fort Bovisand Underwater Centre as a training ground for commercial divers as it was sheltered, only 10 m deep, had minimal current and had underwater visibility between 2 m and 5 m. Figure 1. Three-dimensional model of the Breakwater Fort site The chosen site contained a number of fixed and rigid structures suitable for recording. These included two large concrete blocks, the wall of the Fort itself (Fig 1) and a 7 m long ex- Pilot cutter called Tavy. A network of 21 control points was installed on the structures (Fig 2), the shape was designed to give a large amount of redundancy and minimal sensitivity to depth errors. The control points installed on the structures were 5mm galvanised coach bolts cemented into pre-drilled holes. The diameter of the control point bolts was accounted for within the processing program. 2

Figure 2. Measurements between the 21 control points Over a period of a year many teams of divers had recorded to 1mm resolution a pre-defined set of measurements between the control points. The same set of tape measures was used for each exercise. As a check for systematic errors, all tape measures were calibrated against a steel tape measure at 5 m, 10 m and 20 m distances and any tape measures with more than 5 mm in error were not used. To minimise transcription errors, standard recording forms were used and the data was transferred from the form straight into a computer spreadsheet for analysis. Measurements were exported from the spreadsheet directly into the processing program. A set of tape measurements was made on a single baseline on land for comparison. Data from other sites was collected and compared with the results from the test site. Results The Data Set A total of 32 baselines with distances between 2 m and 13 m were measured more than 5 times, comprising a total of 178 measurements. Another 85 baselines that had less than 5 measurements each were included giving 304 measurements in total. Outliers in Repeat Measurements The majority of the baselines showed one or more gross errors even though some lengths were less than 3 m. Figure 3 shows the residuals for 12 measurements of a 1.7m long baseline where 11 of the measurements have residuals less than 20mm but one is in error by nearly 140mm. 3

Figure 3. Measurement residuals for baseline 5-6 Average Standard Deviation With the obvious outliers removed the mean and standard deviation of the measurements was calculated for each baseline. Together the baselines gave an average standard deviation of 25mm where the minimum was 8 mm and the maximum was 60 mm. This value for precision of 25 mm was used as the starting point for subsequent analysis. Adjustment The measurements were adjusted in one large least-squares network adjustment using the Site Surveyor computer program. The resulting computed positions of the points are the best estimate based on all of the measurements, giving the most likely positions. The program also computes the residual for each measurement, the difference between the measured value and the value computed from the positions of the points. Figure 4 shows the residuals plotted in size order with a vertical bar showing the approximate point of separation between valid measurements to the left and outliers to the right. Many large outliers existed in the data set however there was no clear distinction between a valid measurement and a small outlier. Figure 4. Measurement residuals in size order 4

Two methods were used to identify outliers, the first was to manually reject any measurements over a given limit. A rejection limit of 3 standard deviations (99.7%) was used with our previously computed precision of 25mm, so any outlier larger than 75 mm was rejected. The second method was to use an automatic rejection process based on the Delft method recommended for processing GPS measurements (Table 1). The automatic rejection method is an iterative process that rejects the measurement with the highest w-statistic or normalised residual after adjustment. The process stops when all remaining w-statistic values lie below 2.576 or 99%. The normalised residual is obtained by dividing a residual by its standard deviation so both the manual and automatic methods are driven by our estimate of precision. Table 1: Post adjustment results Rejection None 3 S.D. Automatic RMS of the residuals 143 mm 30 mm 27 mm Measurements 304 304 304 Measurements used 304 247 240 Measurements rejected 0 57 64 Measurements rejected 0 % 18.8% 21.0% Outliers Of the 304 observations, 168 (55%) were smaller than the defined measurement standard deviation and 57 were larger than 3 times the standard deviation. The Root-Mean-Square (RMS) of residuals gives an idea of how well all the measurements fit together. In the case where no outliers were rejected the RMS value was 143 mm showing that outliers existed in the data set. In the cases where outliers were rejected the RMS of residuals becomes close to the expected value of 25 mm, our nominated precision for the measurements. It was expected that longer measurements would be more likely to have larger residuals however the data shows that this is not the case. Interestingly, the set of residuals shows no correlation between measurement length and residual (Fig. 5). Figure 5. Measurements and residuals in residual size order 5

Typical point accuracy The accuracy of the position of a point is expressed as error ellipse based on both the precision of the associated distance measurements and the position of the point within the control network. The ellipse is an approximate graphical representation of the horizontal accuracy in all directions. Error ellipses are commonly shown at 2.447 times their 1 σ values and are then referred to as 95% confidence regions. The sizes of the error ellipses computed by the adjustment program are directly related to the size of the standard deviation defined for the tape measurements. The standard deviation also sets the maximum acceptable residual so a small standard deviation gives a small size of error ellipse but requires better quality measurements to achieve it. A simulated network of four fixed control points was set up with a test point in the centre, one on a baseline between two control points and a third outside the control network (Fig. 6). The accuracy of the position of a set of points was then calculated based on the given precision of 25 mm (Table 2). The position error ellipses are shown 20 times full scale. Figure 6. Position precision test Table 2: Point accuracy results Semi-Major (95%) Semi-Minor (95%) Note Test A 43 mm 43 mm Centre of the network Test B 48 mm 39 mm Between two control points Test C 56 mm 37 mm Outside the control points This assumes the fixed station positions to be perfectly known, if the co-ordinates are in error then the fix will be thought to be of better quality than it actually is. Other Sites Measurements from a number of other similar underwater sites were processed in order to obtain an estimate of the distance measurement precision and the percentage of outliers in the data set (Table 3). In each case the automatic rejection tool in Site Surveyor was used. Table 3: Residuals and outliers from other sites Control points RMS Residuals. Outliers Hazardous 12 8 mm 8 of 52 15% Boyne 21 15 mm 8 of 101 8% Resurgam 12 17 mm 5 of 45 11 % Coronation 12 8 mm 0 of 39 0% Colossus 18 23 mm 10 of 125 8% Alum Bay 14 10 mm 9 of 77 12% The RMS residual values of between 10 mm to 25 mm are typical for shallow water sites. 6

Measurements Made on Land A set of 12 measurements made on land over a 12.3 m baseline in sheltered conditions with the tape unsupported gave a standard deviation of 6 mm with no outliers. Conclusion Under the test conditions, a standard deviation of 25 mm is valid for measurements made using fibreglass tape measures over distances up to 20 m underwater. This value can be used as a typical figure for tape measurements under similar conditions. The single data set on land showed a standard deviation of 6 mm over a comparable length. The cause of the difference between land and underwater measurements is most likely to be a combination of the effects of any water current on the tape and inability to maintain the correct tension on the tape when underwater. Repeating the tests using a steel-cored tape rather than fibreglass would most likely show an increase in precision as the stretch is less so a higher tension can be used. The number of outliers in the test data set was approximately 20%, considerably larger than is usually assumed for survey work underwater. This high percentage of outliers emphasises the need for making extra redundant measurements and highlights the need for appropriate survey data processing techniques to identify and eliminate the outliers. The tests were done using 3D trilateration measurements however it is safe to assume that the same numbers of outliers will occur when positioning using offsets and ties as the same measurement procedures are used. There were outliers even in short baselines where the tape was supported along its whole length. It is unlikely that stretching in the tape caused these outliers, the more likely cause was mis-reading of the tape measure or transcription errors when transferring measurements to the recording forms or from the forms to the computer. There was no obvious correlation between size of outlier and measurement length so large outliers are as likely to appear in short measurements as long ones. This result was unexpected and hints that a significant proportion of the outliers came from mis-reading or transcription errors. These problems can be minimised with diver training and reducing the number of transcriptions. Where a diver is in voice communication to the surface, fewer mistakes will be made if the surface team rather than the diver record the measurements. The best method appears to be to process measurements on the computer as they are made allowing the immediate identification of outliers as this minimises the amount of re-work to be done. The post-computed position confidence regions for points inside the control network can be approximated to circles 40 mm in radius. This means a typical point positioned using 3D trilateration with tape measures will be accurate to ±40 mm at 95% confidence. This figure can be used as a baseline standard for comparison with other methods of positioning underwater such as acoustic or optical systems under similar conditions. These tests were done under almost ideal conditions for UK waters and the precision achieved is likely to be the highest achievable, so the next step would be to repeat the tests under more taxing conditions. Acknowledgements I am grateful to Paul Dart for getting the measurements made, POP Fort Bovisand and the Queen's Harbour master, Plymouth, for allowing us to sink the Tavy along with Nigel Boston for donating the Tavy and the use of his ship to put it on site. My thanks go to Garry Momber at the Hants and Wight Trust for Maritime Archaeology, Anthony Firth at Wessex Archaeology and Kevin Camidge for survey data from other sites. Thanks also go to Jeremy Green at the Western Australian Maritime Museum for his comments on this paper. 7

References Atkinson K., Duncan A., Green J., 1988, The application of a least squares adjustment program to underwater survey, IJNA 17.2: 119-131 Bannister A., Raymond S. and Baker R., 1994, Surveying ISBN 0470218452 Cross P.A., 1981, The Computation of Position at Sea. Hydrographic Journal 20 Kelland N., 1973, Assessment Trials of Underwater Acoustic Triangulation Equipment. IJNA 2.1 : 163-176 Kelland N., 1994, Developments in Integrated Underwater Acoustic Positioning. Hydrographic Journal 71 Rule N., 1989, The Direct Survey Method (DSM) of underwater survey, and its application underwater, IJNA 18.2: 157-162 UKOOA, 1994, The Use of Differential GPS in Offshore Surveying Uren J. & Price W., 1985, Surveying for Engineers Macmillan ISBN 0333577051 8