Key Features & Advantages of JEHA MK IV (5,000 PSI Hydraulic Test Stands)

Similar documents
Hydraulic Reliability & Preventive Maintenance Report

Pressure Automated Calibration Equipment

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

SINGLE VALVE WITH LOW-FLOW BYPASS

Aquavar SOLO 2 Frequently Asked Questions

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

AUTOMATIC HOSE TEST UNIT, TYPE SPU

SPECIFICATIONS ATTENTION

Copyright, 2005 GPM Hydraulic Consulting, Inc.


L3 Pressure and Level transmitter

Instructions for Use

TEST BENCH FOR SAFETY VALVES

Unit 24: Applications of Pneumatics and Hydraulics

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

Installing a Probe. Typical Installation

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

Pneumatic high-pressure controller Model CPC7000

TR Electronic Pressure Regulator. User s Manual

T EK-SUB 4800C 19 mm Submersible Level Transmitter

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

Air Amplifiers & SYSTEMS

WIDDER TOOLS. HPICAL Calibration Station 1 (203)

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

air driven Standard air gas liquid for high pressure: contents Chatsworth, California, USA

Pneumatic high-pressure controller Model CPC7000

Introduction. Part one: Identify the Hydraulic Trainer Components

Additel 780 Series Pressure Controller

Additel 780 Series Pressure Controller

GasSense NDIR User Manual

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

TECHNICAL MANUAL CALIBRATION INSTRUCTIONS FUEL PRESSURIZING & DUMP VALVE TEST STAND 1TL

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

P499 Heavy Duty Pressure Transducer

M-06 Nitrogen Generator (Nitrogen Making Machine)

Tech Tips. Service Call: Adjustable Hydraulic Valves Flow controls Pressure controls Sequence valves Holding valves

ATL R/V Atlantis AUXILIARY PLANT OPERATION APPENDIX OPERATING PROCEDURES

CHE Well Testing Package/Service:

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

FX134, FX1234, FX3030 Problem and Solutions

Additel 780 Series Pressure Controller

WORKHOLDING APPLICATION BOOKLET

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

Valve test benches. Systems overview

Constant and Particle Free Point-of-Use Water Pressure

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

Table of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2.

BUBBLER CONTROL SYSTEM

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

Fio 2.2 Smart add-on for gas pressure Regulators

LPG DRIVER ATTENDED TRANSPORT LOADING

Pressure Independent Control Valve (PICV) Fig DN15-32

Pressure calibration. 20

HYDRAULIC CYLINDER TEST

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Control Panels & Depth Gauges

Pressure calibration equipment

Autocalibration Systems For In Situ Oxygen Analyzers

Phuel Portable Control Units

Nitrogen Advantage. Better Tire Pressure Retention. Improved Fuel Economy. Extended Tread Life. Elimination of Oxidation. Reduction in Tire Failures

Selecting the right pressure sensor for your application

GMA FUNCTIONAL TEST SETTING & TESTING OF SPIN UP PARAMETERS. P0586 REV -- 20, June 2000 GPB SCIENCE MISSION PROCEDURE

PEAPOD. Pneumatically Energized Auto-throttled Pump Operated for a Developmental Upperstage. Test Readiness Review

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Supplementary Operator s Manual 42/24-14 EN Rev. 3

High Pressure Breathing Air Compressors

Malema Sensors M-2700 Integrated Ultrasonic Flow Meter

TRADITIONAL HIGH VIBRATION HOSE SYSTEM THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

Aespire 7100 Essential performance Compact design

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

HumiSys HF High Flow RH Generator

[Instruments for vacuum measurement, checking and adjustment] 3

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Digital Vacuum Regulator

ASSE International Product (Seal) Listing Program

THE DELIVERY OF GAS SUPPLY

The Ins and Outs of I/P Transducers

KGW - ISOTHERM. Operating Instructions. Level controlling device for liquid nitrogen LEVEL CONTROL LN2

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

TECHNICAL DATA Q= C. Table 1 - Specifications

The Faraday Test Centre Rochester

FILTER TYPE PRESSURE SNUBBER

TECHNICAL DATA. Q = C v P S

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

Truck-mounted Mass Flow Metering for LPG Delivery

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

AutoChanger Installation & User Guide Issue 2

Air Operated Hydraulic Pumping Systems to 50,000 psi

553 Series.

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Transcription:

Key Features & Advantages of JEHA MK IV (5,000 PSI Hydraulic Test Stands) The key reasons why MRO Facility now requires 5,000 PSI Hydraulic Test Stand are as follows: 1) New generation commercial aircraft like B787, A380, A350 etc. are fitted with better performance aircraft hydraulic components, which require higher test pressure and higher flow rate. 2) Each Hydraulic Independent System must be capable of delivering Flow rate of 25 GPM @ 5,000 PSI and 20 GPM @ 6,000 PSI or a combined of 50 gpm @ 5,000 psi and 40 gpm @ 6,000 psi respectively. 3) Dual Independent Hydraulic System will also be required as new generation aircraft component may require two independent hydraulic power supplies for its repair testing. Current 3,000 PSI Hydraulic Test Stands like our JEHA MK II or MK III are no longer capable to support new generation aircraft components; as such we are offering our JEHA MK IV. 5,000 PSI Hydraulic Test Stand from any OEM including HII can be used to carry out repair testing on any aircraft components whether fitted on commercial or military aircraft including helicopter. Operator Safety & Ease of Operation (See Photos below) Is the Test Sink Area for placing the UUT located on its Main Hydraulic Console (MHC) or located in a separate Area? The Test Sink Area for JEHA MK IV is located on its MHC to provide ease of Operator Testing. Where are the locations of all required Input & Output connections (hydraulic or pneumatic or electrical) or Sampling Ports for the UUT? *UUT: Unit Under Test As for JEHA MK IV, all its Input & Output connections (hydraulic or pneumatic or electrical) or Sampling Ports for the connecting to the UUT are located around the Test Sink Area providing ease of connection & repair testing by the Operator. JEHA MK IV is installed with a transparent Protective Cover for the Test Sink Area, which ensure Operator s safety as the UUT & all its required Input & Output connections (Sampling Ports) are also being enclosed too. If any of the 5,000 PSI Hose is burst during testing, the Operator will not be injured. Therefore the locations of Input & Output connections (Sampling Ports), Test Sink Area and UUT are extremely important safety consideration. Electrical Power Supply Cables for connection to UUT if too long or messy can cause electric shock to Operator as its can be easily damaged. Annual Calibration What are the components required to be removed from the 5,000 PSI Hydraulic Test Bench to be sent out for annual calibration? How many Gauges, Temperature Sensors, Pressure Sensors, Flow Transducers etc. are required to be removed? How long to remove them and how long to fit them back? What is the total down time for 5,000 PSI Hydraulic Test Bench for each annual calibration? As for JEHA MK IV, there are no Gauges fitted. No need to remove any component as JEHA MK IV is designed to provide for calibration of these components at location, without requiring for their removal for annual calibration by using our Instrument Verification Set (IVS). An experience Operator will need about 30 mins to verify acceptable accuracy of built in Instrument like Temperature or Pressure Sensors, Flow Transducers etc. without having to remove them for annual calibration.

Components What is the percentage of components built in house and how is obsolescence on critical components being taken care? How many years can Spares be guaranteed? More than 90% including critical components like Flowmeters, Valves, Pressure Control Devices, Air Driven Gas Boosters or Liquid Pumps used on JEHA MK IV are built in-house by our Pumps Division & Flowmetrics Inc. ensuring spares supportability for more than 20 years. Ease of Maintenance How long to replace Filter Elements or any consumable parts and where are their locations? As for JEHA MK IV, Filter Elements or any consumable parts are easily accessible and does not require disconnecting fittings and/or interconnecting hydraulic lines. Fault Diagnostic Is there any fault diagnostic? As for JEHA MK IV, if a fault exists before system operation or a fault occurs during system operation, fault conditions will immediately report to HMI message field and an audible warning horn HRN is activated. All fault conditions are permanently stored to retentive memory of HMI computer, up to 200 fault conditions Accuracy (see below photos of HMI Display Screen) Are the 5,000 PSI fitted with Gauges and what are their functions and accuracies? JEHA MK IV is not fitted with Gauges. Any critical reading of Pressure, Flow Rate or Temperature is very accurately and digitally displayed on the HMI Display Screen. Specifications Testing & Environmental Qualifications (see attached JEHA MK IV Specifications) Is the 5,000 PSI Hydraulic Test Stand built to any stringent specification requirement testing? JEHA MK IV has also been qualified to the most rigorous military requirement testing such as Environmental, Mobility, Electro Magnetic Interference, Reliability, Maintainability, Shock, Vibration, Sound Attenuation etc. as required by the US Government. Reliability Demonstration Test Has any Reliability Demonstration Test been carried out? What is its expected MTBF (Mean Time Between Failure)? As for JEHA MK IV, its reliability test has been performed on the full range & capabilities of the MHC Pilot Production Unit (PPU) in accordance with MIL HDBK 781A over 1000 hours (MTBF) without failures. Production (http://www.fbodaily.com/archive/2012/08-august/10-aug-2012/fbo-02831090.htm) Is there any production of 5,000 PSI Hydraulic Test Stand at their facility? How many Units are in current production? As for JEHA MK IV, HII is currently in production of 80 Units for US Government & export market. Spares can be guaranteed for more than 20 years.

OPERATOR SAFETY & EASE OF OPERTIONS JEHA MK IV All Displays, Mechanical / Touch Screen Controls, Test Sink Area, Sampling Ports (Hydraulic, Pneumatic & Electrical Power Supply) are located on Main Hydraulic Console (MHC). The Operator only has to look in front without having to move locations providing ease of Operation s operation. All Sampling Ports located inside Test Sink Area with transparent Protective Cover TEST SINK AREA No messy Hoses or Cables from Sampling Ports hanging from one place to another location. All Sampling Ports are located inside the transparent Protective Cover of Test Sink Area providing Operator s safety.

SAMPLING S Hydraulic, Pnuematic & Electrical Supply Located within Test Sink Area 120 VAC 400 HZ outlet 0 50 VDC outlet Test Sink Area 24

FIG. 1 INDEX NO. Table 2. MHC Controls and Indicators - Continued NOMENCLATURE INITIAL POS. 56 CIRCUIT 2 BYPASS VALVE SV5 57 CIRCUIT 2 CYCLING CIRCUIT SHUTOFF VALVE SV8 58 CIRCUIT 2 SUPPLY P2 SHUTOFF VALVE SV6 59 Reservoir Level Indicator 1/2 to 3/4 full 60 CIRCUIT 1 SAMPLING SUPPLY FILTER F1 valve 61 CIRCUIT 1 SAMPLING SUPPLY FILTER F1 port 62 CIRCUIT 1 SAMPLING SUPPLY FILTER F1 63 CIRCUIT 2 SAMPLING SUPPLY FILTER F2 valve 64 CIRCUIT 2 SAMPLING SUPPLY FILTER F2 port 65 CIRCUIT 2 SAMPLING SUPPLY FILTER F2 66 RETURN CIRCUIT SAMPLING RETURN FILTER F4 valve 67 RETURN CIRCUIT SAMPLING RETURN FILTER F4 port 68 RETURN CIRCUIT SAMPLING RETURN FILTER F4 69 LOW PRESS. CIRCUIT SAMPLING SUPPLY FILTER F3 valve 70 LOW PRESS. CIRCUIT SAMPLING SUPPLY FILTER F3 port 71 LOW PRESS. CIRCUIT SAMPLING SUPPLY FILTER F3 72 0 150 PSI AUXILIARY GAUGE PT12 73 0 150 PSI AUXILIARY GAUGE PT13 74 0 600 PSI AUXILIARY GAUGE PT14 SAMPLING S Hydraulic, Pnuematic & Electrical Supply Located within Test Sink Area REF DES SV5 FUNCTION Flow and pressure bypass valve. CW SV8 Cylinder cycling circuit shutoff. CW SV6 Supply port P2 shutoff. LI1 Indicates fluid level of 55 gallon hydraulic reservoir. CW NV1 Sampling port shutoff valve. Capped SP1 Sampling port, POD compatible. Capped SP1A Sampling port for collection bottle. CW NV2 Sampling port shutoff valve. Capped SP2 Sampling port, POD compatible. Capped SP2A Sampling port for collection bottle. CW NV3 Sampling port shutoff. Capped SP3 Sampling port, POD compatible. Capped SP3A Sampling port for collection bottle. CW NV4 Sampling port shutoff valve. Capped SP4 Sampling port, POD compatible. Capped SP4A Sampling port for collection bottle. Capped PT12 Auxiliary pressure transducer gauge inlet port, 0-150 PSI. Capped PT13 Auxiliary pressure transducer gauge inlet port, 0-150 PSI. Capped PT14 Auxiliary pressure transducer gauge inlet port, 0-600 PSI. 28

FIG. 1 INDEX NO. Table 2. MHC Controls and Indicators - Continued NOMENCLATURE 75 0 600 PSI AUXILIARY GAUGE PT15 76 0 6000 PSI AUXILIARY GAUGE PT16 77 0 6000 PSI AUXILIARY GAUGE PT17 INITIAL POS. REF DES FUNCTION Capped PT15 Auxiliary pressure transducer gauge inlet port, 0-600 PSI. Capped PT16 Auxiliary pressure transducer gauge inlet port, 0-6000 PSI. Capped PT17 Auxiliary pressure transducer gauge inlet port, 0-6000 PSI. 78 120 VAC 400 HZ outlet - CN7 Supplies AC voltage for testing of UUT. 79 0 50 VDC outlet - CN4 Supplies DC voltage for testing of UUT. 80 N2 SUPPLY P7 XDUCER PT11 CALIBRATION valve 81 N2 SUPPLY P7 XDUCER PT11 CALIBRATION NV15 Isolates gas booster N 2 supply pressure transducer PT11 for calibration. Capped CP11 Gas booster N 2 supply pressure transducer port for calibration. 82 PODS RETURN Capped - Quick Disconnect (QD), allows direct connection of the Portable Oil Diagnostic System (PODS) for sample analyzing. 83 CIRC 1 SUPPLY PRESS XDUCER PT1 CALIBRATION valve 84 CIRC 1 SUPPLY PRESS XDUCER PT1 CALIBRATION 85 CIRC 1 RETURN BACK PRESS XDUCER PT2 CALIBRATION valve 86 CIRC 1 RETURN BACK PRESS XDUCER PT2 CALIBRATION 87 CIRC 2 SUPPLY PRESS XDUCER PT3 CALIBRATION valve 88 CIRC 2 SUPPLY PRESS XDUCER PT3 CALIBRATION NV5 Isolation valve for supply pressure transducer PT1. Capped CP1 Supply pressure port for Circuit 1 supply calibration. NV6 Back pressure transducer PT2 isolation valve used during calibration. Capped CP2 Back pressure calibration port. NV7 Supply pressure transducer PT3 isolation valve used during calibration. Capped CP3 Supply pressure port for Circuit 2 supply calibration. 89 RETURN R1 Capped R1 Circuit 1 return port 90 91 CIRC 2 CYCLING BACK PRESS XDUCER PT4 CALIBRATION valve CIRC 2 CYCLING BACK PRESS XDUCER PT4 CALIBRATION Capped NV8 CP4 Cycling back pressure transducer PT4 isolation valve during calibration. Circuit 2 Cycling back pressure. 29

Table 2. MHC Controls and Indicators - Continued FIG. 1 INDEX NO. NOMENCLATURE INITIAL POS. REF DES FUNCTION 92 LOW PRESS CIRC PRESS XDUCER PT5 CALIBRATION valve 93 LOW PRESS CIRC PRESS XDUCER PT5 CALIBRATION NV9 Low pressure circuit supply pressure transducer PT5 isolation valve used during calibration. Circuit 2 Capped CP5 Low pressure circuit supply. 94 FREE RETURN R3 Capped R3 Allows return of hydraulic fluid to reservoir with less than 5 PSI drop. Port can be used to fill the reservoir from a hydraulic servicing unit. 95 TEST BENCH AIR INLET PRESS XDUCER PT6 CALIBRATION valve 96 TEST BENCH AIR INLET PRESS XDUCER PT6 CALIBRATION 97 TEST BENCH N2 INLET PRESS XDUCER PT7 CALIBRATION valve 98 TEST BENCH N2 INLET PRESS XDUCER PT7 CALIBRATION NV10 Shop air inlet pressure transducer PT6 isolation valve used during calibration. Capped CP6 Air inlet pressure. NV11 Nitrogen inlet pressure transducer PT7 isolation valve during calibration. Capped CP7 Nitrogen inlet pressure. 99 RETURN R2 Capped R2 Circuit 2 return port. 100 HYDROSTATIC PUMP AIR INLET XDUCER PT8 CALIBRATION shutoff valve 101 HYDROSTATIC PUMP AIR INLET XDUCER PT8 CALIBRATION 102 N2 BOOSTER AIR INLET XDUCER PT9 CALIBRATION shutoff valve 103 N2 BOOSTER AIR INLET XDUCER PT9 CALIBRATION 104 HYDROSTATIC SUPPLY P8 XDUCER PT10 CALIBRATION valve 105 HYDROSTATIC SUPPLY PXDUCER PT10 CALIBRATION NV12 Hydrostatic pump air inlet pressure transducer PT8 isolation valve during calibration. Capped CP8 Hydrostatic pump air inlet pressure. NV13 Gas booster air inlet pressure transducer PT9 isolation valve during calibration. Capped CP9 Gas booster air inlet pressure port. NV14 Hydrostatic pump supply pressure transducer PT10 isolation valve during calibration. Capped CP10 Hydrostatic supply pressure port. 30

FIG. 1 INDEX NO. Table 2. MHC Controls and Indicators - Continued NOMENCLATURE INITIAL POS. REF DES FUNCTION 106 CIRCUIT 2 SUPPLY P2 Capped P2 Supply ports for Circuit 2. 107 LOW PRESS. CIRCUIT SUPPLY P5 Capped P5 Supply port for low pressure circuit. 108 CIRCUIT 2 CYCLING P4 Capped P4 Supply port for cycling test. 109 CIRCUIT 2 CYCLING P3 Capped P3 Supply port for cycling test. 110 NITROGEN CIRCUIT SUPPLY P7 Capped P7 Supply port for pneumatic (N 2 ) circuit. 111 CIRCUIT 1 SUPPLY P1 Capped P1 Supply ports for Circuit 1. 112 HYDROSTATIC CIRCUIT SUPPLY P6 Capped P6 Supply port for hydrostatic circuit. 113 WASTE RESERVOIR LEVEL INDICATOR 1/2 or less LI2 Indicates fluid level of 10 gallon waste hydraulic reservoir. 114 WASTE RESERVOIR DRAIN VALVE BV10 Handle vertical BV10 Allows draining of 10 gallon waste hydraulic reservoir. 115 Main circuit breaker OFF CB1 Circuit breaker used for primary circuit protection. 116 Shield assembly - - Protects operator from pressurized UUTs during testing of pumps and motors. 117 Remote EMERGENCY STOP Out E/S2 Immediate shutdown of HCTS operations. 31

HMI DISPLAY SCREEN Pressure, Flowrate & Temperature etc Figure 2. HMI Display, Main Screen 12

Figure 3. HMI Display, Hydrostatic and Pneumatic Circuits Screen Figure 4. HMI Display, Info Screen 13

Hydraulics International, Inc. JEHA MK IV will have same Specifications as our military version HCT-12 HII HCT-12 has been qualified and approved for the following requirements: 1- Operating Temperature. The HCT-12 is able to operate in ambient conditions that range from 32 o F to 122 o F. 2- Storage Temperature. Will range from -60 o F to 160 o F. 3- Electromagnetic Interference. the HCT-12 is considered as equipment operating within a surface ship environment, below deck, of a metal-hulled vessel. Performed all tests in accordance with MIL-STD-461. The following tests of the standard are to be performed as a minimum: CE102, CS101, CS114, CS115, CS116, RE101, RE102, RS101 and RS103. 4- Voltage Spike. The HCT-12 meets the requirements MIL-STD 1399, Section 300A, paragraph 5.3.3. 5- Power Interruption. The HCT-12 meets the requirements MIL-STD 1399, Section 300A, paragraph 5.3.4. 6- Shock. The HCT-12 meets the requirements of MIL-S-901, Grade B, Type A, deck mounted equipment, with mounting orientation unrestricted. The MHC is operating during the test. 7- Shipboard Vibration. The HCT-12 meets the requirements as defined in MIL-STD-167, Type I and Type II while operating. 8- Transportation Vibration. The HCT-12 is able to withstand vibration as defined in MIL-STD-810, Method 514.5, Procedure I (General Vibration),Platform: Truck/Trailer Category: Restrained Cargo 9- Operation under Tilt. The HCT-12 is able to operate on a surface that is moving while being tilted 8.5º horizontally in any direction, regardless of fluid level. 10- Leakage. The HCT-12 does not leak if tilted in any direction up to 15 degrees from the horizontal in any direction regardless of fluid level. Unit lines, fittings, and components downstream of and including the pump shall not leak when exposed to 1.5 times expected delivery pressure. 11- Humidity. The HCT-12 meets the requirements of MIL-STD-810, Method 507. 12- Salt Fog. The MHC meets the requirements of MIL-STD-810, Method 509. 13- Sound Attenuation. Sound/noise levels created by the HCT-12 (exclusive of a UUT) does not more than 85 dba at the operator s location with the HCT-12 mounted two feet from the rear wall and operating both dynamic hydraulic circuits at their maximum capacity. The operator s location shall be designated as within 10 feet of the front of the HCT-12 and 5.5 feet above ground level.

Hydraulics International, Inc. JEHA MK IV will have same Specifications as our military version HCT-12 Maintainability Demonstration Test The HCT-12 meets all maintenance actions, corrective maintenance actions and required quantitative maintainability metrics in accordance with MIL-HDBK-470A. Mean Time Between Failure. The HCT-12 has a mean time between failure (MTBF) of no less than 390 hours. A failure is defined as the HCT-12 inability to perform all required functions to the full extent of this specification. The MTBF requirement is in accordance with the requirements and provisions of MIL-HDBK-470A. Mean Time to Repair. The HCT-12 has a mean time to repair (MTTR) of 4 hours or less. The MTTR is defined as the mean time required to perform any necessary corrective actions to recover from a failure. The MTTR requirement is in accordance with MIL-HDBK-470A. Reliability Demonstration Test The reliability test has been performed on the full range and capabilities of the MHC Pilot Production Unit (PPU) in accordance with MIL-HDBK-781A over 2000 hours without failures. The predicted MTBF for HCT-12 obtained from the reliability predictions are significantly higher than the demonstrated reliability. The predicted MTBF is provided in Table below. HCT-12 Predicted Failure Rates Module Predicted Failure Rate MTBF Required MTBF HCT-12 446.52 2240 390