Medical Gas Data Sheet (MGDS) Medical air

Similar documents
Medical Gas Data Sheet (MGDS) Medical air. BOC: Living healthcare

Medical Gas Data Sheet (MGDS) Medical helium. BOC: Living healthcare

Lung Function medical gas mixture 4.

Lung Function medical gas mixture 1.

Medical oxygen/carbon dioxide mixtures

Medical Gas Data Sheet (MGDS) Medical helium. BOC: Living healthcare

5% carbon dioxide/air medical gas mixture.

Synthetic medical air.

9% helium/35% oxygen/ nitrogen medical gas mixture.

10% carbon dioxide/oxygen medical gas mixture.

5% carbon dioxide/oxygen medical gas mixture.

Medical carbon dioxide

Medical oxygen. LIV IQ Digital therapy device.

Compressed medical oxygen.

Compressed medical oxygen.

SUMMARY OF PRODUCT CHARACTERISTICS

1. NAME OF THE MEDICINAL PRODUCT. Medicinal Air, Air Liquide 100%, medicinal gas, compressed. 2. QUALITATIVE AND QUANTITATIVE COMPOSITION

SUMMARY OF PRODUCT CHARACTERISTICS

Summary of Product Characteristics

Compressed Medical Oxygen Medicinal gas, compressed

BOC: Living healthcare. Manual. LIV IQ BOC Integrated Valve with digital display portable delivery system for Medical Oxygen. BOC: Living healthcare

User manual. ZX trolley.

BRITISH COMPRESSED GASES ASSOCIATION Registered office: 4a Mallard Way, Pride Park, Derby, UK. DE24 8GX Company Number: 71798, England

SUMMARY OF PRODUCT CHARACTERISTICS. 1 NAME OF THE MEDICINAL PRODUCT Lung test gas, CO/He AGA 0.28%, 9.3% medicinal gas, compressed

Dialflow Regulator. Instructions for Use

Medical Gas Data Sheet (MGDS) ENTONOX. Essential safety information. BOC: Living healthcare

Peninsula Dental Social Enterprise (PDSE)

Medical Gas Data Sheet (MGDS) ENTONOX. BOC: Living healthcare

Pressure Regulators. Instructions for Use

Liquid Medical Oxygen Medicinal gas, cryogenic Package Leaflet: Information for the User

Liquid medical oxygen.

Medical nitrous oxide.

3. COMPOSITION / INFORMATION ON INGREDIENTS 4. FIRST AID MEASURES 5. FIRE FIGHTING MEASURES

Oxygen Dialflow Meter. Instructions for Use

3. COMPOSITION / INFORMATION ON INGREDIENTS 4. FIRST AID MEASURES 5. FIRE FIGHTING MEASURES

3. COMPOSITION / INFORMATION ON INGREDIENTS 4. FIRST AID MEASURES 5. FIRE FIGHTING MEASURES

SAFETY DATA SHEET According to Regulation (EC) N 1907/2006

Safety information. Working safely with the GENIE hydrogen cylinder

SAFETY DATA SHEET. ón óñj. 2.2 : Non flammable, non 5.1 : Oxidizing. MœM« : Listed in Annex IV / V REACH, exempted from registration.

MATERIAL SAFETY DATA SHEET NITROGEN

SAFETY DATA SHEET. 2.2 : Non flammable, non toxic gas. : Listed in Annex IV / V REACH, exempted from registration. Use

Label 2.2: Non-flammable, Non-toxic gas 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING

BOC Healthcare training

Pressure Regulator. Instructions for Use

Safety information. Working safely with the GENIE hydrogen cylinder

DATA SHEET Revised edition no : : Non flammable, non toxic gas. : Listed in Annex IV / V REACH, exempted from registration.

BOC Healthcare Training

SAFETY DATA SHEET. 2.2 : Non flammable, non toxic gas. Westmorland Street, Hull HU2 0HX, United Kingdom

SAFETY DATA SHEET ARGON. : Argon in non-refillable gas cylinders. CAS-No.: EC no. : Index no.: --

MSDS Interspiro Spiroscape EEBD (compressed breathing air)

Globally Harmonized System of Classification and Labelling of Chemicals (GHS)

DATA SHEET Revised edition no : 0. o óm MÁM M« : Industrial and professional. Perform risk assessment prior to use. Company identification

Medical gas cylinder data chart. BOC: Living healthcare

SAFETY DATA SHEET ACETYLENE (DISSOLVED)

MATERIAL SAFETY DATA SHEET

Glasgow City Council EDUCATION SERVICES. Technician Support Service

DATA SHEET Revised edition no : : flammable gas. M M«

Safety Data Sheet. Chlorine trifluoride. Version : 1.05

Safety Data Sheet. Nitrous oxide. Version : see paragraph 16 "OTHER INFORMATION" see paragraph 16 "OTHER INFORMATION"

SAFETY DATA SHEET PRODUCT NAME Sulfur hexafluoride 1.2 RELEVANT IDENTIFIED USES OF THE SUBSTANCE OR MIXTURE AND USES ADVISED AGAINST :

Liquid Nitrogen for Medical Use (Medical Device). Instructions for use.

MATERIAL SAFETY DATA SHEET COMPRESSED LASER-GAS

Micro Dial-Flowmeter. Instructions for Use

SAFETY DATA SHEET GAS MIXTURES ARGON 75% CARBON DIOXIDE 25%

MATERIAL SAFETY DATA SHEET CARBON DIOXIDE

DATA SHEET Revised edition no : : Non flammable, non toxic gas. : Listed in Annex IV / V REACH, exempted from registration.

3. COMPOSITION / INFORMATION ON INGREDIENTS 4. FIRST AID MEASURES 5. FIRE FIGHTING MEASURES

MEDICAL REGULATOR RANGE (MEDIREG RANGE)

Safety data sheet Helium, compressed.

2.2 : Non-flammable, nontoxic

Components CAS Number Concentration (Volume) Nitrogen %

General Precautions for handling compressed gases

DATA SHEET Revised edition no : 0. o óm MÁM M« : Industrial and professional. Perform risk assessment prior to use. Company identification

MATERIAL SAFETY DATA SHEET COMPRESSED HELIOX

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET

PACKAGE LEAFLET: INFORMATION FOR THE USER. Medical Oxygen/Carbon Dioxide Mixtures Oxygen, Carbon Dioxide, Medicinal gas, compressed

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET. Oxygen, Refrigerated Liquid DOT Hazard Class: 2.2

Oxygen Dialflow Meter. Instructions for Use

Level 9 / 380 St. Kilda Road 3004 Melbourne VIC Australia

DATA SHEET Revised edition no : : Non flammable, non toxic gas.

SAFETY DATA SHEET. Non-toxic but may displace oxygen which can cause dizziness, unconsciousness and death by asphyxiation.

DATA SHEET Revised edition no : 0 MÁM M«MÅ. : Industrial and professional. Perform risk assessment prior to use. Company identification

Safety Data Sheet. Ammonia. Version : 1.03

Safety Data Sheet Nitrogen, compressed.

MEDICAL GASES Manufacture, Storage, Transport & Delivery B.KIRUTHIGA LECTURER DEPT OF PHARMACEUTICAL CHEMISTRY

SAFETY SHEET. (D.M. nr /01/92 - S.O.G.U. nr /02/92) Product: GAS CONTROL Sheet 4050 v. 0 Page

Material Safety Data Sheet

Safety Data Sheet. Version : 1.03

SAFETY DATA SHEET. CARBON DIOXIDE in non-refillable gas cylinders

Material Safety Data Sheet Argon, Compressed

Quebec Quebec Tel : Fax : MSDS: Argon Compressed PRODUCT INFORMATION

SAFETY PRINCIPLES FOR PRESSURE REGULATORS FOR MEDICAL OXYGEN CYLINDERS

Before using or working with the Grab n Go Heliox system, please read and understand the usage and safety instructions provided in this booklet.

MEDICAL GAS CYLINDERS SELECTION AND MAINTENANCE OF SEALS USED ON HIGH PRESSURE CYLINDERS

DATA SHEET Revised edition no : : flammable gas. M M«

SAFETY DATA SHEET according to Regulation (EU) 2015/830

Safety Data Sheet. R125 (Pentafluoroethane) Version : 1

Transcription:

Medical Gas Data Sheet (MGDS) Medical air Essential safety information Summary of Product Characteristics (SPC) pages 2-6 Additional Safety Information pages 7-8 BOC: Living healthcare

2 Medical air SPC 1. Name of the medicinal product Medical air. 2. Qualitative and quantitative composition Medical air specification. Medical air cylinders are supplied to the following specification: oxygen content 20.9% O2 ± 0.5% nitrogen balance. The medical air cylinder specification complies with the European Pharmacopoeia monograph (1238). 3. Pharmaceutical form Medicinal gas, compressed. 4. Clinical particulars 4.1 Therapeutic indications Medical air is used: as a replacement for atmospheric air when the atmosphere is contaminated by noxious fumes, vapours or gases in anaesthesia as a carrier gas for volatile anaesthetic agents as a power source for pneumatic equipment in ventilators and incubators to provide uncontaminated and controlled air flows. 4.2 Posology and method of administration For breathing purposes medical air is administered by various means, commonly by self contained or compressed air line breathing apparatus. In anaesthesia, medical air is administered via a cylinder and valve assembly through a face mask or endotracheal tube. 4.3 Contraindications Medical air is contraindicated where oxygen or other gaseous combinations would be indicated (airways obstruction, pneumonia, and a myriad of cardio-respiratory conditions). 4.4 Special warnings and precautions for use Medical air should never be administered to a patient if, when it is mixed with other gases, the oxygen content is less than 21%. Care is needed in the handling and use of medical air cylinders. 4.5 Interaction with other medicinal products and other forms of interaction None applicable. 4.6 Pregnancy and lactation Medical air does not adversely affect pregnancy and lactation. 4.7 Effects on ability to drive and use machines The use of medical air does not affect the ability to drive or use machinery. 4.8 Undesirable effects None applicable.

3 5. Pharmacological properties 4.9 Overdose None applicable. 5.1 Pharmacodynamic properties The characteristics of medical air are: odourless, colourless gas molecular weight 29.00 boiling point -194 C (at 1bar(g)) density 1.225kg/m 3 (at 15 C). Atmospheric air contains approximately 21% oxygen, 78% nitrogen and 1% Argon with trace contents of other inert gases (xenon, neon, krypton). The nitrogen is absolutely inert, but the oxygen in air is an absolute necessity for life for its cellular respiratory function. 5.2 Pharmacokinetic properties Under conditions of normal atmospheric pressure, the pharmacokinetic data on medical air are essentially those of respiration, oxygen carriage and cellular metabolism and are inapplicable. 5.3 Preclinical safety data None stated. 6. Pharmaceutical particulars 6.1 List of excipients None. 6.2 Incompatibilities Medical air is non-flammable but supports combustion. 6.3 Shelf life 36 months. 6.4 Special precautions for storage Medical air cylinders should be: 6.5 Nature and contents of container stored under cover, preferably inside, kept dry and clean, and not subjected to extremes of heat or cold and away from stocks of combustible material stored separately from industrial and other non-medical cylinders stored to maintain separation between full and empty cylinders used in strict rotation so that cylinders with the earliest filling date are used first stored separately from other medical cylinders within the store F size cylinders and larger should be stored vertically. E size cylinders and smaller should be stored horizontally. Warning notices prohibiting smoking and naked lights must be posted clearly in the cylinder storage area and the emergency services should be advised of the location of the cylinder store. Care is needed when handling and using medical air cylinders. Medical air cylinder and valve details Medical air is supplied as a compressed medical gas in high pressure gas cylinders. All cylinders used for the storage of medical air are manufactured from high tensile steel. The E, F, G and J size cylinders are designed with working pressure of at least 137bar(g) and the T4 and T7 size cylinders are designed for a maximum working pressure of 230bar(g). Medical air cylinders are supplied with two main types of cylinder valves, dependant upon the cylinder filling pressure and the type of application. Conventional cylinder valves are fitted to all cylinders which are designed to be used with a pressure regulator. All of these cylinders are fitted with valves with outlet connections that conform to either IS0 407 (pin index) or BS 341. (5/8" BSP F) and are filled to 137bar(g).

4 Other high pressure cylinders are fitted with valves that have an integral pressure regulator, with an outlet pressure of 4bar(g) or 7bar(g) dependant on their intended use. These regulated valves are fitted with an IS0 5145 product specific filling connection and a product specific BS 5682 Schrader outlet connection. A summary of medical air cylinders, their size and construction, type of valve fitted and valve outlet pressure is detailed below: Cylinder Gas content Cylinder Valve type Nominal size (litres) construction outlet valve outlet connections pressure bar (g) AZ 170 Aluminium Pin Index 137 E 680 Steel Pin Index 137 F 1360 Steel Thumbwheel valve 137 BS 341 No.3 G 3400 Steel Top outlet MPR valve 137 BS 341 No.3 Top J 6800 Steel Outlet MPR valve 137 Side spindle pin T4 4600 Steel Index valve 4 Variable demand (0-300 litres/min) Integral regulated Valve with ISO 5145 product specific filling port and BS Schrader outlet (air 4bar(g)) T7 4600 Steel Variable demand 7 (0-300 litres/min) Integral regulated valve with ISO 5145 product specific filling port and BS Schrader outlet (air 7bar(g)) The basic specification for the cylinder valves used in medical air cylinders are: Valve body High tensile brass Spindle Steel Spindle tip Nylon 6.6 Valve outlet 5/8 BSP (F) side outlet Valve operation Handwheel O rings (T4/T7 only) Sintered bronze 6.6 Special precautions for disposal and other handling All personnel handling medical air cylinders should have adequate knowledge of: properties of the gas correct operating procedures for the cylinder precautions and actions to be taken in the event of an emergency. Preperation for use: Cylinders used with a pressure regulator. Sizes E, F, G, J. To prepare the cylinder for use: remove the tamper evident seal and the valve outlet protection cap. Ensure the cap is retained so that it can be refitted after use do not remove and discard any batch labels fitted to the cylinder ensure that an appropriate medical air regulator is selected for connection to the cylinder

5 ensure the connecting face on the regulator is clean and the sealing washer fitted is in good condition connect the regulator, using moderate force only and connect the tubing to the regulator/flowmeter outlet. Only the appropriate regulator should be used for the particular gas concerned open the cylinder valve slowly and check for any leaks The cylinder valves and any associated equipment is not lubricated and kept free from oil and grease. Cylinders with an integral regulated valve. Sizes T4 and T7. To prepare the cylinder for use: check the cylinder contents gauge on the cylinder valve to ensure that there is sufficient gas contents in the cylinder remove the tamper evident seal and cover fitted over the valve outlets ensure that the correct equipment is selected for connection to the cylinder connect the air Schrader probe to the Schrader outlet open the cylinder valve slowly and check for any leaks the cylinder valves and any associated equipment is not lubricated and kept free from oil and grease. Leaks Cylinders used with a pressure regulator. Sizes E, F, G, J. Having connected the regulator or manifold yoke to the cylinder check the connections for leaks using the following procedure: should leaks occur this will usually be evident by a hissing noise should a leak occur between the valve outlet and the regulator or manifold yoke, depressurise and remove the fitting and fit an approved sealing washer. Reconnect the fitting to the valve with moderate force only, fitting a replacement regulator or manifold tailpipe as required sealing or jointing compounds must never be used to cure a leak if leak persists, label cylinder and return to BOC. Cylinders with an integral regulated valve. Sizes T4 and T7. check the connection for leaks using the following procedure: should leaks occur this will usually be evident by a hissing noise close valve, remove connection, check and refit never use excessive force when connecting equipment to cylinders if leak persists, label cylinder and return to BOC. Use of cylinders After use When medical air cylinders are in use ensure that they are: only used for medicinal purposes turned off, when not in use, using only moderate force to close the valve only moved with the appropriate size and type of trolley or handling device handled with care and not knocked violently or allowed to fall firmly secured to a suitable cylinder support when in use not allowed to have any markings, labels or batch labels obscured or removed not used in the vicinity of persons smoking or near naked lights. When the medical air cylinders are empty ensure that the: cylinder valves is closed using moderate force only and the pressure in the regulator or tailpipe released valve outlet cap, where fitted, is replaced empty cylinders are immediately returned to an empty cylinder storage area for return to BOC.

6 7. Marketing authorisation holder BOC Ltd The Priestley Centre 10 Priestley Road The Surrey Research Park Guildford Surrey GU2 7XY 8. Marketing authorisation number(s) PL 0735/5002R 9. Date of first authorisation/ renewal of the authorisation Date first granted: 01/09/1972 Date of renewal: 21/07/1992 10. Date of revision of the text 24/04/1998 11. Dosimetry (if applicable) Not applicable. 12. Instructions for preparation of radiopharmaceuticals (if applicable) Not applicable.

7 Medical air Additional Safety Information 1. Contact information BOC telephone number to be used in the event of an emergency: UK 0800 111 333 2. Hazards Classification labelling and packaging regulations Warning. Contains gas under pressure; may explode if heated (H280). Protect from sunlight: store in a well-ventilated place. (P410 + P403). Dangerous Preperations Directive Keep out of the reach of children (S2). Additional safety statements No smoking or naked flames near medical gas cylinders. Use no oil or grease. Keep away from extremes of heat and combustible material. Store cylinders under cover in a clean, dry and well ventilated area. Medical air is supplied as a compressed gas in a high pressure cylinder. Cylinders may explode if subjected to extremely high temperatures (if involved in a fire). 3. Fire fighting measures If medical air cylinders are involved in a fire: if it is safe to move the cylinders, - close cylinder valve to stop flow of product - move cylinders away from source of heat if it is not safe to move the cylinders - cool with water from a protected position. All types of fire extinguishers may be used when dealing with a fire involving medical air cylinders. No special protective equipment for fire fighters is required. There are no hazardous combustion products released from the gas. 4. Accidental release measures If a large volume of medical air is released, if it is safe to do so, you should close the cylinder valve. 5. Exposure controls None. 6. Disposal considerations It is recommended that medical air cylinders should not be vented after use - they should be returned to BOC with any residual gas where they will be vented before refilling in a safe environment. If, for safety reasons, a cylinder is required to be vented after use, the gas should be vented to atmosphere in a well ventilated area. Contact BOC if further guidance on venting cylinders is required.

7 7. Transport of cylinders When medical air cylinders are required to be transported, ensure that the cylinders are: located in a compartment separated from the driver adequately restrained not leaking and have their valves closed. The vehicle must be adequately ventilated. Ensure the driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. It is advisable to provide the driver with written instructions that detail the actions to be taken in the event of an accident or emergency. Cylinders should be removed from the vehicle as soon as possible. 8. Transport information UN Number UN1002 Proper Shipping Name Air, compressed Material Class 2 Labels: 2.2. Hazard Identification Number 20 Emergency Action Code: 2T Tunnel Restriction code E Transport Category 3 BOC Healthcare Customer Service Centre, Priestley Road, Worsley, Manchester M28 2UT Tel: 0800 111 333, Fax: 0800 111 555, Email: bochealthcare-uk@boc.com, www.bochealthcare.co.uk The stripe symbol and the letters BOC are registered trade marks of The BOC Group Limited. Both BOC Limited and The BOC Group Limited are members of The Linde Group, the parent company of which is Linde AG. Reproduction without permission is strictly prohibited. Copyright 2009 HLC/405205/JIG/APUK/0410/3M