Pressure & Flame Protection

Similar documents
Pressure & Flame Protection

BAILEY CASH VALVE. Other cryogenic fluids include liquefied natural gas, fluorine, krypton, neon, methane and ethane.

CASH VALVE TYPE KP BACK PRESSURE VALVES

CRYOGENIC PRESSURE REGULATOR

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

MEDICAL EQUIPMENT CATALOG

CASH VALVE CRYOGENIC CONTROLS

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases.

CompAir provide high quality and reliable Nitrogen solutions

ON-SITE OXYGEN GENERATION WHY PSA SYSTEMS ARE A GOOD CHOICE

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

Pressure Regulator B-95

Standard Series Safety Relief Valves

776 Cryogenic Safety Valve

Welcome to the LESER Seminar, Taipei 28. June Design_of_safety_relief_valves_250804_Cal

SAFETY FEATURES OF PORTABLE CRYOGENIC LIQUID CONTAINERS FOR INDUSTRIAL AND MEDICAL GASES

Liquid Gas Cylinder (LGC)

EHS Laboratory Guidance: Cryogenic Material

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

Pressure Reducing Valves Pressure Reducing with. Broady Flow Control. C Series Range. Pressure Reducing Valves. Broady Flow Control

Handling and Storage of Gases

LGSS Liquefied Gas & VSS Vapor (Gas) LGSS VSS LGSS. Features and Benefits

BCGA GUIDANCE NOTE 17

Cash Valve CRYOGENIC CONTROLS. ISSUED - FEBRUARY 2000 CAVMC-0514-US-0208 ISO 9001 Certified

Trifecta High-Pressure Systems

There are three fuelling systems which use LNG/CNG and which may be found in vehicles today:

Cash Valve. Industrial Valves and Controls. Flow Control. ISSUED CAVMC-0507-US-0511 ISO 9001 Certified

Air Amplifiers & SYSTEMS

A Rationale for Pressure Relief Device(s) Qualification Requirements (LH2)

ASK HEROSE HEROSE NEWS NEW! EXCLUSIVE STOCK GENERANT SDC SERIES FOR DOT-4LC AND TC-4LM LIQUID CYLINDERS SILENT OPENING LCV & POP ACTION CRV CALL NOW!

Design Change Notification

Trifecta Systems. Cryogenic Equipment for High Performance Gas Supply. Trifecta Product Catalog

Easy-Pro Installation & Operations Guide

Compressed Gases and Cryogens

Liquid Nitrogen for Duct Cleaning

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

PREVENTION OF EXCESSIVE PRESSURE DURING FILLING OF CRYOGENIC VESSELS

PRODUCT GUIDE Spring 2015

APPS-160 Gen 2 User Manual

The new CryoEase Service - your No. 1 choice of gas supply

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

Cryogenic Materials Operating Procedure and Safety Requirements

Each cryogenic liquid has its own specific properties, but most cryogenic liquids can be placed into one of three groups:

Medical Gas Data Sheet (MGDS) Medical helium. BOC: Living healthcare

C 10 Pressure Reducing Valve

Si C132. Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions

DF1 and DF2 Diffusers

Compressed Gas Properties. Introduction. Compressed Gas Properties. Definition of a Compressed Gas

Safe Handling & Use of Liquid Nitrogen and Other Cryogenic Gases

Pilot Operated Safety Relief Valves For Liquified Gas Carriers

Pressure Regulators. Operating Instructions. Instrumentation

Chlorine Supply Containers And Piping

System Pressure Manager Standard & System Pressure Manager Plus

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Model PRS-07i. Stainless Steel Low Pressure, In-Line Pressure Regulator (Reducing Valve)

NEW EDGE SERIES REGULATORS & OUTFITS

MANUAL GAS MANIFOLDS

Vacuum Jacketed Piping Solutions

CRYOGENIC GAS EQUIPMENT. Technology for a Better Future. ISO/TS Registered TS-0068 Q1-0274

TECHNICAL SPECIFICATION. StirLNG-4 Stirling Cryogenics gas liquefier for LNG production

Unit 24: Applications of Pneumatics and Hydraulics

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

Oxygen Usage Best Practice Guide

756 Safety Relief Valves

Pressure Reducing Valves Pressure Reducing with. Broady Flow Control. D Series Range. Pressure Reducing Valves. Broady Flow Control

NGN Series nitrogen generator

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

OPERATION MANUAL NTF-15

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

CRYOSPEED CRYOSPEED. Leading edge cryogenic gas supply solutions.

v. Size shall be specified on drawings.

Spirax Compact FREME Flash Recovery Energy Management Equipment

Precision matters. HiQ equipment for specialty gases.

OPERATION MANUAL NTF-60 Plus

CRYOGENIC INDUSTRIAL GASES LOWEST TEMPERATURES? MY VALVES REMAIN COOL. Cryogenic valves for temperatures as low as 269 C. HEROSE of Pressure.

Liquid nitrogen. Safetygram 7

Optimizing Gas Supply for Industrial Lasers

CRYOGENIC SERIES Regulators, Pressure Gauges, Shut-off Valves, Relief Valves Technology for a Better Future

I. CHEM. E. SYMPOSIUM SERIES NO. 85 MULTI-STAGE OVER PRESSURE PROTECTION AND PRODUCT CONTAINMENT ON HIGH PRESSURE POLYMERISATION REACTORS

PSSI 36 General Confined Spaces, Tunnels, Culverts and Similar Spaces

PURPOSE OF THE POLICY

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

MANAGEMENT OF LIQUID NITROGEN

KGW-ISOTHERM. Information and Operating Instructions for Dewar Vessels Type 26 to 29 B or B-E

CLASS TLP Pressure Reducing Valve

CRYOGENICS & LNG Application Guide

Medical Oxygen Concentrator Systems. Generate gases on site generate savings

LASERLINE global gas solutions. LASERLINE global gas solutions. Gas supply equipment for laser gas installations.

BACK PRESSURE / SUSTAINING

DUPLEX PRESSURE REDUCING SET

Linde Cryogenics. Helium Recovery Systems.

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

MATHESON s LaserPro Gases and Gas Delivery Equipment

Storage and transfer of cryofluids

9/6/11 RSPT Medical Gas Therapy. Manufacture, Storage and Delivery of Medical Gases Part 1

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

BACK PRESSURE / SUSTAINING

VAPOR CONTROL SYSTEMS QUALITY, DEPENDABILITY, SERVICE. REPUTATION BUILT ON. Valve Concepts, Inc. com. A Cashco, Inc.

Transcription:

Pressure & Flame Protection Cryogenic Products

Bailey and Cash Bailey and Cash have been sister companies since the early 1990 s.these two product lines have been integrated and now offer existing and new Cash cryogenic customers the benefits of the well established Bailey distribution network and international sales offices. In doing so, we are able to provide local knowledge and expertise on a global scale. Utilising our established and extensive commercial and manufacturing systems to control order routing, we can now offer a wider range of products from our Bailey factory in the UK.These products can be supplied drop shipped from the USA or directly from our complementary UK stock. Bailey Bailey is located in Manchester, United Kingdom and we have been developing and manufacturing valves for more than 160 years. By employing modern techniques and cutting edge equipment, we continue to pioneer new developments in valve technology, while delivering the high standards of quality and service expected from our growing customer base. At Bailey we design and manufacture safety relief valves, pressure reducing valves and associated products that are used extensively throughout the process industry.the performance of Bailey products has been proven time and time again in demanding environments such as chemical, food and drink, heating and pharmaceutical industries. These industries demand accurate in-process regulation and require the highest level of overpressure protection to ensure the safety of plant and personnel. Bailey possesses one of the best Research and Development Laboratories in Europe.With continual investments in high specification machinery and a state of the art clean room facility, Bailey has provided a wide range of products for many years. Our products are available for any application, including cryogenic and oxygen clean duties. Cash Cash is located in North Carolina, USA and they have been developing and manufacturing cryogenic valves for decades.they are renowned world wide for their quality and expertise in the field of cryogenic gas applications. Cash continue to pioneer new and innovative developments in this field, which are continually delivered to the high standards of quality expected from the demanding industrial gas producers of the world. Also available: Birkett - API/ASME Spring loaded and pilot operated safety relief valves and thermal relief valves. Amal - Flame arresters. Marston - Bursting discs and explosion vent panels. Marvac - Tank protection valves.

Cryogenic Products The Cash range of cryogenic products are used predominantly on cryogenic gas systems. Many industrial gas supply companies now supply their gas in its liquefied state. In this context the term cryogenics is the liquefaction of gases.typically the liquid is then turned back to a gas on site, whenever demand is generated. Many different gases can be supplied in a liquefied state, from fine industrial gases such as nitrogen, to medical gases such as oxygen. Industrial gas companies still supply these gases to small gas users, such as small oxyacetylene welding shops, doctors, etc., in the high pressure, compressed gas state. However, when the usage is substantial, there are valid commercial reasons to supply the gas in the liquid state. Liquefied gas occupies only a quarter of the space of a compressed gas. For example a welding shop can replace 17 oxyacetylene cylinders with just one 1,250 litre cryogenic vessel.this saves storage space and saves time in changing bottles. The liquefied gas is stored in a dewar. A dewar can range from the size of a man to the size of a building and is designed like a highly specified Thermos flask - keeping heat out of the vessel whilst maintaining the cryogenic temperature inside. There are various elements to a typical dewar; the pressure build circuit, the safety relief system, the economiser circuit and the final house supply line. The Cash range has products which are used in all of the above areas. Safety Relief A full range of safety relief valves and bursting discs are available to protect the dewar from over pressurisation. Pressure Regulation Several ranges of back pressure and pressure reducing valves are available to regulate pressure in the various parts of the dewar system. Associated Products Strainers, low temperature cut off valves and isolating valves are also available to complement the above items.

The Cryogenic System While each gas company will have their own very different and individual designs, the example below illustrates the key elements of the system and the types of products available from Bailey-Cash. Pressure Build Circuit A dewar stores liquefied gas at cryogenic temperatures. Heating this liquid in the pressure build coil changes its state to gas; this gas is fed to the top of the dewar, which pressurises the system.the pressure is used to deliver the liquefied gas to the vaporizer and hence the final house supply line. Pressure Build Coil Pressure Build Regulator Pressure Build Economiser Safety Relief System If the pressure build circuit becomes uncontrolled, the pressure will continue to rise to unacceptable levels.therefore the dewar needs protection from over pressurisation by either a safety relief valve, bursting disc or a combination of the two. Safety Relief Bursting Disc Gas Liquefied Gas Economiser Economiser Circuit There will be times when there is no demand on the dewar, and while it is very well insulated, it will still absorb some temperature from the atmosphere - particularly on hot days.this heat absorption will tend to convert the liquid to gas and thus pressurise the system.the system is protected by the safety relief system but typically the safety relief system will release the gas to atmosphere, where it is lost.the economiser system will convert the gas back to liquid at pressures below the set pressure of the safety system, thus preventing loss of product to the atmosphere. Final House Supply Line This part of the system warms the liquid to convert it back to a gaseous state ready for final usage.there are times when it is critical that the cold liquid does not enter the final house line. Such an instance is the supply of oxygen to patients in a hospital. Under such circumstances a low temperature cut off valve is required. Isolating Strainer Isolating Vaporizer Low Temperature Cut-off Pressure Regulator Pressure Build Economiser At Cash we have developed a range of combination valves, which combine the functions of the back pressure regulator and the economiser valve. These valves can simplify the layout of the system, reduce the amount of pipe work and the number of valves required.

Pressure Build Circuit A32 A36 B E55 G60 SY-70C Final House Supply Line A31 LTC E55 G4

Economiser Circuit FRM FRM2/FRM2 (HP) FR/FR6 Pressure Build Economiser Circuit PBE1 PBE2 PBE4 Safety Relief System Bursting Discs Safety Relief 776

Type Pressure Build Regulator Strainer Low Temp. Cut-off Pressure Regulator Back Pressure Regulator Combination Regulator Safety Bursting (Rupture) Disc Model Sizes Connections Body Temperature Max. Inlet Outlet Pressure Materials Range Pressure Range ºC (ºF) Barg (Psig) Barg (Psig) A-32 1 4 & 3 8 Screwed Brass or Stainless -196 to 65 41.4 0.14 to 41.4 (-320 to +150) (600) (2 to 600) A-36 3 8 Screwed Brass or Stainless -196 to 65 27.6 0.7 to 17.2 (-320 to +150) (400) (10 to 250) B 1 4 to 1 Screwed Bronze -196 to 65 27.6 0.7 to 17.2 (-320 to +150) (400) (10 to 250) B 1-1 4 & 1-1 2 Screwed Bronze -196 to 65 27.6 0.7 to 10.3 (-320 to +150) (400) (10 to 150) B 2 Screwed Bronze -196 to 65 27.6 0.35 to 6.9 (-320 to +150) (400) (5 to 100) E-55 1-1 4 to 2 Screwed Bronze -196 to 65 27.6 1.38 to 20.7 (-320 to +150) (400) (20 to 300) G-60 1 4 to 1 Screwed Bronze or Stainless -196 to 65 41.4 0.35 to 41.4 (-320 to +150) (600) (5 to 600) G-60 1-1 4 & 1-1 2 Screwed Bronze or Stainless -196 to 65 41.4 0.35 to 27.6 (-320 to +150) (600 ) (5 to 400) SY-70C 1 2 to 1-1 2 Screwed Bronze -196 to 65 27.6 (-320 to +150) (400) SY-70C 2 Screwed Stainless -196 to 65 27.6 (-320 to +150) (400) LTC 1 2 to 2 Screwed Bronze -196 to 150 27.6 (-320 to + 300) (400) A-31 1 4 Screwed Brass -18 to 65 27.6 0.14 to 12.1 (0 to +150) (400) (2 to 175) G4 1 2 to 2 Screwed Brass or Stainless -20 to 260 41.4 0.7 to 21 (-4 to +500) (600) (10 to 300) G4 1 2 to 2 Flanged Brass or Stainless -20 to 260 41.4 0.7 to 21 (-4 to +500) (600) (10 to 300) E-55 1 2 to 1 Screwed Bronze -18 to 65 27.6 0.7 to 17.2 (0 to +150) (400) (10 to 250) E-55 1-1 4 to 2 Screwed Bronze -18 to 65 27.6 1.38 to 20.7 (0 to +150) (400) (20 to 300) FR 1 2 to 2 Screwed Bronze or Stainless -196 to 65 17.2 0 to 17.2 (-320 to + 150) (250) (0 to 250) FR-6 1 2 Screwed Bronze or Stainless -196 to 65 41.4 0 to 41.4 (-320 to +150) (600) (0 to 600) FR-6 3 4 to 2 Screwed Bronze or Stainless -196 to 65 27.6 0 to 27.6 (-320 to +150) (400) (0 to 400) FRM 1 4 & 3 8 Screwed Bronze or Stainless -196 to 65 41.4 0.14 to 41.4 (-320 to +150) (600) (2 to 600) FRM-2 1 4 to 1 2 Screwed Bronze or Stainless -196 to 65 17.2 0 to 19 (-320 to +150) (250) (0 to 275) FRM-2 1 4 to 1 2 Screwed Bronze or Stainless -196 to 65 27.6 13.8 to 27.6 (HP) (-320 to +150) (400) (200 to 400) PBE-1 1 4 Screwed Brass -196 to 65 27.6 3.5 to 24.1 (-320 to +150) (400) (50 to 350) PBE-2 1 2 Screwed Bronze -196 to 65 27.6 0.7 to 17.2 (-320 to +150) (400) (10 to 250) PBE-4 1 2 Screwed Bronze -196 to 65 41.4 6.7 to 41.4 (-320 to +150) (600) (100 to 600) 776 1 2 to 1 Screwed Bronze or Stainless -196 to 65 41.4 (-320 to +150) (600) 776 1 1 2 to 2 Screwed Bronze or Stainless -196 to 65 34.5 (-320 to +150) (500) Forward 1 2 to 2 Screwed Stainless -196 to 65 51 Acting or Flanged (-320 to +150) (740) Reverse 1 2 to 2 Screwed Stainless -196 to 65 51 Buckling or Flanged (-320 to +150) (740)

Safety Systems UK Ltd. Sharp Street,Worsley, Manchester, UK, M28 3NA. Tel +44 (0)161 790 7741 Fax +44 (0)161 703 8451 / 1985 Email support@safetysystemsuk.com Web site www.safetysystemsuk.com BCOV0306 Registered Office: Victoria Road, Leeds, LS11 5UG, UK