HNP. HNP073 Series. Flows up to 70 L/min Fluid viscosities to 700 cst PME HNP073

Similar documents
HNP-021 Oil Purifier. Description. Specifications. Features. Contact Us:

Instructions For Use USD3156. Kleenpak Capsule with Pegasus Protect Prefiltration Membrane

HydroCOM: High energy savings and excellent controllability

Auxiliary Valve PRS6 Pressure Reducing Valve. Catalogue HY /UK June 2003

THE WORLD COMPETITIVENESS SCOREBOARD 2011

Upgrading Bio-Plex Manager 4.1, 5.0, or 6.0 Software to Bio-Plex Manager 6.1 Software

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

W I L D W E L L C O N T R O L FLUIDS

Max Sort Sortation Option - Letters

AREA TOTALS OECD Composite Leading Indicators. OECD Total. OECD + Major 6 Non Member Countries. Major Five Asia. Major Seven.

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

Instructions For Use. USD 2474a. Pall Minidisc Filter Capsules with Ultipor DV20 Virus Removal Filter Membrane

Liquid ring vacuum pumps in compact design

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Spirax Compact FREME Flash Recovery Energy Management Equipment

Auxiliary Valve QDS6 Sequence Valve, 3-way. Catalogue HY /UK June 2003

Theatre Control Panel. Instructions for Use. January 2017 ASF-29 (1)

SF 6 Product Guide. Gas Analysis Instruments and Accessories

Applications. What moves your world

SPIROVENT VACUUM DEGASSERS

GCE CENTRAL GAS SYSTEMS THE DRINKS DISPENSE INDUSTRY EQUIPMENT FOR GAS SUPPLIER SYSTEMS

UPA All fluids. Full flow All stainless steel

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar

BERMAD Fire Protection Hydraulic Control Valves

UPB All fluids. Full flow All stainless steel

Flamco Flamco-Fill STA Flamco-Fill STM

Demography Series: China

UPA All fluids. Full flow All stainless steel

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

Vertex VP Operation and Maintenance

Maintenance handbook

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

FIL Qualifying Event Proposal. Problem Statement. Proposal for voting at GA

Value Exported (CDN$) Support Systems ,165 firearms ,389 firearms ,465 firearms ,500 rocket launchers

Update of trade weights data underlying the EERs and HCIs

HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to:

User Guide for the Sterile Cord Blood Collection Unit

Intrinsically safe solenoid valves on/off controls - ATEX certification

Global Construction Outlook: Laura Hanlon Product Manager, Global Construction Outlook May 21, 2009

Liquid ring vacuum pumps in compact design

Happiness trends in 24 countries,

Related Products: Auto Drain Valve. Model/Specifications. Model

U.S. TRADE. U.S. - World Volume of Trade 3,192, ,688, ,821, ,580, ,569,

Firearms & parts firearms & parts firearms & parts rocket launcher components

Optimization of a Proven Technology

SCH-27. Diaphragm Pressure Switch. Setting range: mbar to bar. Temperature: max C. Material: stainless steel

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

BOSS PULISCI PROVA IMPIANTI MEDIA

Customer Responsibilities

I. World trade in Overview

GE Oil & Gas Model. Masoneilan* Air Lock-up Valve Instruction Manual. GE Data Classification : Public

C645A-E Pressure Switches

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg)

VERTICAL AIR COMPRESSORS

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

Target Cleanliness Worksheet. Systemic Contamination Control

Diaphragm Accumulators

New AQF Filter Polymer Filtration System

2018 Hearthstone Wild Open. Official Competition Rules

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

ASB Accumulator Safety Blocks

NITROGEN CHARGING KIT type PC 11.1 E 04-11

DEWATERING PUMP SOLUTIONS. Pneumatic pumps

NITROGEN CHARGING KIT type PC 11.1 E 01-12

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Best Practice Guide, Servomex 2700

FV Flash Vessel Installation and Maintenance Instructions

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

MITIGATING PIPE AND RISER HYDRAULIC PIPELINE ISSUES WITH THE I-RISER PLUS

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

System Pressure Manager Standard & System Pressure Manager Plus

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Description. Chassis. Cabinet. Long chassis - Type: Dimensions (mm): 2700 x 1200 x 1678

QuickHeat TM Packaged Heat Exchanger Solutions

Series IRV1000/2000/3000

Remote Control VP04 Pneumatic Proportional Remote Control Valve zrc02. Catalogue HY /UK December, 2004

Manual Actuated Boiler Blowdown Valves

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Pressure Regulators. Instructions for Use

Operation Manual Air Saver Unit ASV5000 Series

VERTICAL AIR COMPRESSORS

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

1. PARTS INTRODUCTION ELECTRICAL NOTES INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10.

DF1 and DF2 Diffusers

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Liquid ring vacuum pumps in compact design

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

B-Series. breathing air systems flow capacity: scfm

Neil Kane Managing Director EMT UK

NGN Series nitrogen generator

SIHI LPH-X - Liquid Ring Compressors

Transcription:

F L U I D C O N D I T I O N I N G P U R I F I E R S Flows up to 70 L/min Fluid viscosities to 700 cst PME HNP073

Introduction Extending service life Reliability of systems and the life of system components and fluids are extended by minimising fluid oxidation, maintaining lubricity properties and reducing aeration. Corrosion within the fluid system can also be controlled by reducing the formation of acids. Acids are formed by the interaction of water with oil oxidation and other degradation products. The many ways that Pall fluid conditioning systems save money The application of the Pall fluid conditioning purifier provides a wide range of opportunities for reducing operating costs: Extension of fluid life. Improved productivity. Purification of collected fluids. Reduced time for fluid changes. Less frequent fluid disposal. Unsupervised operation. Increased equipment reliability. Minimised corrosion within fluid systems. Description The Pall HNP fluid conditioning purifier uses the principle of vacuum dehydration to remove 100% of free water and as much as 90% of dissolved water. It also removes 100% of free and entrained gases and up to 80% of dissolved gases. Particulate removal is achieved using a high Beta rated (ß x(c) 1000) Ultipor III filter element to polish the fluid before discharge back to the system reservoir. The HNP Purifier can be used as a fixed installation or as a portable unit that is easily connected to any fluid system. Simple push button control starts the purifying process. Automatic controls, integral to the unit constantly monitor the operation of the purifier and will safely shutdown the unit if acceptable operating limits are exceeded. Data logging provides the user with historical data on the operation and functionality of the purifier The HNP073 can also be used in conjunction with other Pall Diagnostic equipment such as the Pall Water Sensor by monitoring system fluid water content levels and signalling the HNP to come on-line in the event that the fluid exceeds acceptable limits. When the water content returns to within specification, a further signal from the water sensor shuts down the purifier. This and other special applications are available Contact the Pall sales office for details. Telemetry Pall telemetry system software is available providing a number of customer benefits: Real-time monitoring from any pc running a web browser, connecting via Ethernet network, modem (GSM, radio or PTSN landline) or direct cable connection. Automatic notification of fault conditions or service requirements to pre-selected e-mail addresses (including e-mail enabled mobile phones). Automatic mailing of logged data at scheduled intervals to pre-selected e-mail addresses for trending and further analysis - system usage, occurrences, operating pressures, system fluid temperature. Manual download of logged data for trending and further analysis system usage, operating pressures, system fluid temperature. Support services To achieve optimum performance of specialist equipment, planned maintenance programmes and formalised service procedures should be employed and undertaken by only suitably qualified personnel. To meet this requirement Pall provide Service Agreements in a range of flexible packages, designed to increase the overall effectiveness of operating any of the Pall range of HNP purifiers. For more information on the support services available from the Pall Aftermarket Service Division, please refer to literature no. PIHPAMS, or contact Pall sales on (023) 9230 2409. 2

Technical Information How water enters a system Water can enter a system in many ways including: Condensation from air. Seepage through reservoir covers, access panels, and damaged seals. Leakage from water-cooled heat exchangers. Retraction of water wetted cylinder rods. Contaminated make-up fluid. Worn and/or incorrectly installed gland seals. Water in fluid takes two forms Dissolved water (up to the saturation point) exists in most fluid systems and free water (above the saturation point) exists in many. Fluid is said to be saturated when it contains all the dissolved water it can hold. Any increase in water content above this point results in the formation of free water droplets suspended in the fluid. Free water can form stable emulsions with some fluids or can be entrained as droplets under other conditions leading to corrosion and other problems if not removed. Damage caused by water Corrosion Water is the most common chemical contaminant in fluid systems. It attacks the system by causing: Metal etching through corrosion. Fluid breakdown, including additive precipitation, fluid oxidation and reduction of lubricating film thickness. Accelerated surface fatigue of metals. Accelerated abrasive wear of hydraulic components. Loss of dielectric strength in insulating fluids. Corrosion is caused by the presence of acids and free water in a fluid resulting in: Rapid surface finish deterioration. Rust and corrosion pits (metal etching). Accelerated surface fatigue. 50% reduction in bearing life. The production of these acids can be greatly reduced by the removal of water. Fluid breakdown In any mechanical system, the lubricant must be considered a key component. Fluid breakdown involves the loss of essential components of the fluid and accelerates the various forms of failure. Reduced viscosity and dynamic film thickness. Accelerates fatigue, eventually causing seizure. Causes additives to precipitate and form acid sludge which block clearances, plug filters and further accelerate wear. HNP073 Performance The HNP073 Purifier is designed to reduce and maintain the water content in a fluid system to below saturation level of the system fluid (<300ppm for a typical mineral oil). However, when large water ingress occurs, the HNP073 can remove up to 45 litres per day. The actual water removal rate depends on many variables including system design, oil type, temperature, viscosity, water content, emulsion stability and additives package. 3

Technical Information Removes free and dissolved air All fluids contain some dissolved air and other gases and may contain some free air. Air causes a variety of problems, many of which can be costly. These include: Foaming. Slow system response with erratic action. A reduction in system stiffness. Higher fluid temperature. Pump damage due to cavitation. Inability to develop full system pressure. Acceleration of fluid oxidation. Ordering information Purifier Pall Part No: Replacement Element Pall Part No: HNP073 Table 1 Table 2 Table 3 Table 4 Table 5 Inlet: Outlet: Code C or N: Outlet: Code A or B: Air Breather: (see table 5) (see table 5) HC8300EOT16 HC8304F HC8304F Table 3 HC0293SEE5 16 39 Table 4 Table 4 Table 3 Table 4 Table 1. Voltage Code Voltage S 400V AC V 460V AC Other voltages available on application. Table 3. Filter Element Code Rating (µm) (ß x(c) 1000)* KP 5 KN 7 KS 12 KT 22 Other filter element ratings available on application. *Beta ratios are designated using the symbol (c) to signify they were measured using the ISO 16889 procedure. Table 2. Electrical Frequency Code Electrical frequency 3 50 Hz 3 PH 4 60 Hz 3 PH Other frequency and phase options available on application. Pall Machinery and Equipment also design and manufacture explosion protected purifiers for Zones 1 and 2. Customer applications requiring purifiers for hazardous environments should refer to Pall publication PIH HXP or, consult the Pall sales office on +44 (0)23 9230 3303 or e-mail m&e_sales@pall.com. Table 4. Seal Type Code Seal material Fluid services H Nitrile Petroleum based fluids Z Fluorocarbon Specified synthetics Table 5. Mounting Options Code Option Nominal outlet filter length C Castor and wheels fitted 16" N Skid mounted 16" A Castor and wheels fitted 39" B Skid mounted 39" 4

Instrumentation and Control Alarm warning beacon PLC display with keypad control Power on light Inlet ball valve (not shown) Discharge ball valve Start push button Stop push button Control reset push button Emergency stop button Main isolator Float switch 5

Specifications General specification Dry weight: 450 kg Overall dimensions: Length (mm): 1570 Width (mm): 680 Height (mm): 1920 Inlet connection: G2" female to BS2779 Outlet connection: G1 1 2" female to BS2779 (other options available - consult Pall) Circulation flow rate: 70 L/min 50 Hz option 84 L/min 60 Hz option Total motor power: 5.5 kw (50Hz) 7.0 kw (60Hz) Fluid compatibility: Compatible with petroleum based fluids, synthetic hydraulic fluids rated for use with fluorocarbon seals (see table 4 for seal options). Maximum viscosity (at purifier): 700 cst Temperature range: +10 C to +75 C Max pressure for inlet: 3.0 bar Min pressure for inlet: -0.4 bar g Max pressure for outlet: 7 bar Normal operating vacuum: -0.60 to -0.9 bar g Water removal: Pall fluid conditioning purifiers removes all free water, free gases, dissolved water (up to 90%) and dissolved air (up to 80%). The HNP073 meets all current harmonised European directives including the machinery, low voltage and EMC directives (CE marked). WARNING: If there is any possibility that the fluid being purified has been contaminated with a toxic fluid, the vapours of which could cause a hazard, the Pall Purifier should not be used unless adequate precautions have been taken to vent the vapours in accordance with safety standards and local codes. This caution is necessary to prevent the possibility of toxic injury to personnel. The oil purifier must not be used for fluids with flash point below 93 C, or for fluids contaminated with flammable or combustible fluids. This caution is necessary to prevent the possibility of fire or explosion. Pall Machinery and Equipment A division of Pall Europe Limited Europa House, Havant Street Portsmouth PO1 3PD, England (023) 9230 3303 telephone (023) 9230 2507 fax m&e_sales@pall.com Because of developments in technology these data or procedures may be subject to change. Consequently we advise users to review their continuing validity annually. Part numbers quoted above are protected by the Copyright of Pall Europe Limited. Visit us on the web at www.pall.com/m&e Pall Corporation has offices and plants throughout the world in locations including: Argentina, Australia, Austria, Belgium, Brazil, Canada, China, France, Germany, Hong Kong, India, Indonesia, Ireland, Italy, Japan, Korea, Malaysia, Mexico, the Netherlands, New Zealand, Norway, Poland, Puerto Rico, Russia, Singapore, South Africa, Spain, Sweden, Switzerland, Taiwan, Thailand, United Kingdom, United States, and Venezuela. Distributors are located in all major industrial areas of the world. Your distributor is: and Pall are trade marks of Pall Corporation. Filtration. Separation. Solution is a service mark of Pall Corporation. 2002, Pall Europe Limited. 6 March 2002. Printed in England. HNP073/DAP/2M/0302