Running HPLC Methods on an ACQUITY UPLC System

Similar documents
ACQUITY UPLC H-Class. System Guide Revision C. Copyright Waters Corporation 2016 All rights reserved

LC, RSLC, Bio RS and Dual Gradient Systems

PANACEA P125 USER MANUAL

GUIDE TO ULTRA-FAST HPLC. Quick Tips for Converting Conventional Reversed-Phase HPLC Separations to Ultra-Fast Separations

no peaks missing peaks too small peaks increasing retention decreasing retention

ACQUITY UPLC Sample Manager - Fixed Loop Operator s Overview and Maintenance Information

Capillary Conversion System CCS-4/NC & CCS-05/NC. Installation and Operating Instructions. Operating Instructions

Ascentis Express HPLC Columns with Fused-Core Technology

Connecting a SSL/PTV Backflush System

PANACEA P200 STAINLESS STEEL USER MANUAL

UWPR. LC-MS setup. Before you connect your trap and column. Connecting your trap and column

GCMSD-Headspace Analysis SOP

TROUBLESHOOTING. Dwell Volume Revisited. Gradient transfer does not have to be problematic.

UltiMate 3000 Viper Capillary Kits for Intelligent LC (LCi) System Solutions

UP-F Delrin TM Winged Nut. UP-F PEEK TM Nut. with F-142 PEEK TM Ferrule

Agilent G3180B Two-Way Splitter Kit

Ensuring Best Possible UHPLC Performance Through an Innovative Capillary and Fitting Design

PANACEA P100 LOW PRESSURE USER MANUAL

PFC Analysis Kit for ACQUITY UPLC System Guide

Acclaim RSLC. (Rapid Separation Liquid Chromatography)

Agilent 1290 Infinity LC System Applications requiring the Agilent Ultra-Low Dispersion Kit

H15 Series BASO 100% Shutoff, Automatic Pilot Valve

Agilent 1290 Infinity Pump Head Maintenance

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

Considerations and Best Practices for Maintaining Your Agilent GC s Split/Splitless Injection Port

Instant Connect Helium Saver Injector Module

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Connectors. SECTION 2 OF 3 SECTIONS ON CONNECTORS VHP Tees and Crosses. Top Seller SEE STARRED PRODUCTS. VHP Tees & Crosses for Capillary Tubing

Markes Thermal Desorption Systems Site Preparation Page 1 of 8

GILMONT ACCUCAL FLOWMETERS

Installation, Operation, and Maintenance Manual

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Best Practice for Identifying Leaks in GC and GC/MS Systems

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

International Journal of Generic Drugs ANALYTICAL METHOD PROCEDURES THIS SOP IS 'SWITCHED : OFF : ON'

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

6890 GC Site Preparation

COMPRESSION TUBE FITTINGS

Advances in Capillary Column Backflushing

Anti-flood device Model B-1

ThermoVault Max. Extreme Temperature Thermal Barrier. Product User Guide

Ghost Peaks: How to Fix a Haunting Problem. Jacob A. Rebholz Teledyne Tekmar VOC Product Line Manager

ANALYTICAL SCALE HPLC AGILENT SYSTEMS OPERATIONAL QUALIFICATION

Valves FLUIDICS VALVE OVERVIEW & FUNCTIONS ROTARY SHEAR VALVES STAND ALONE VALVE PRODUCTS MANUAL VALVES SPARE PARTS VALVE ACCESSORIES

Evaluation of linear and step gradient performance and retention time precision of the Agilent 1200 Series Rapid Resolution LC

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

The instrument will process the samples one by one till all the samples have been cleaned up.

PP-1, PP-1W, PP-2, & PP-3

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

3 Flow and Pressure Control

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

SOP: Buck Scientific BLC-20P HPLC Operation

Maintenance of the Electronic ( EPC ) Pressure Controllers on GCs

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

Installation, Operation, and Maintenance Manual

Installation Procedure for your Disco Double Kit, by Airgun Lab, LLC.

Recovery collection complete sample recovery in preparative HPLC

System Overview. TCD Detector temperature setpoint Regulator

Beverage Systems. Component Inspection and Service TSB-Y Date: Subject: Products Affected: Description: July Inspection of CO 2

Agilent 1220 Infinity II LC Mobile Upgrade Kit

Installation Instructions

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

SDS 9414i HPLC Pump. 1. Standard Accessories Stainless Steel Version PEEK Version Safety Instructions...

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

Installation and Use Manual

Constant Pressure Crude Oil Container Model CPCCP

Air Operated Hydraulic Pumping Systems to 50,000 psi

Precision Liquid Settlement Array Manual

Gas Chromatography. MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass Gold, and Clarus 500 GC/MS Systems

Model Series 62 Constant Differential Relay

Installation Instructions

PR4 Installation, Operation & Maintenance Instructions (DOT Certification Included)

Installation Instructions

HPLC systems. Overview

INSTRUCTIONS FOR MODELS SG6190 & SG6191 GLASS ENCASED, LOW PRESSURE, HIGH PURITY, MOISTURE PURIFIERS

Instruction Manual Updated 7/26/2011 Ver. 2.2

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

CHM Gas Chromatography: Our Instrument Charles Taylor (r10)

Instructions for use Compressed air injector with water trap

Pressure Injection Cell Operator s Manual

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators

Method Development Solutions

Steel Spring Driven Reel Instruction Manual

ms NoVent II Instruction Booklet

TriPod Safety Coupler Installation & Operating Instructions for Models TP4, TP5, TP6, and TP7

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

The Open-Split Capillary Interface. Part No

SIMPLAIR PIPING TOOL. JXT Company

Prep LC Training Manual S.V.

G92 Series BASOTROL Automatic Pilot Gas Valve

Pressure Dump Valve Service Kit for Series 2300 Units

operator s manual plus system system nanolc Operator s Manual Revision A1

Peak Biotech - Company & Product Presentation

Gas Conversion Kit Pilot Ignition Heaters

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

INSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations

ACV-10 Automatic Control Valve

COMPRESSION TUBE FITTINGS

Transcription:

Running HPLC Methods on an ACQUITY UPLC System Note: This document is an addendum to the ACQUITY UPLC System Operator s Guide. Contents Topic Page System considerations 1-1 Choosing fittings 1-3 System considerations Traditional HPLC methods run on an ACQUITY UPLC system can differ in retention time and in some cases peak order from the same methods run on traditional HPLC equipment. The differences are primarily due to lower system volume and reduced bandspreading in the ACQUITY UPLC system, which operates with a maximum injection volume of 50 μl and a maximum flow rate of 2 ml/min. You can minimize discrepancies between HPLC and UPLC methods by compensating for the differences in system volume. See also: For more information on transferring methods, consult the ACQUITY Console online Help. The Waters ACQUITY UPLC Columns Calculator (provided with your ACQUITY UPLC software and also available on Waters Web site) automates the scaling calculations required to convert isocratic or gradient HPLC methods to UPLC methods. The ACQUITY UPLC system uses a loop-based autosampler. The amount of sample loaded on the column for a given injection volume, and the subsequent sample recovery, can be different than when you use a traditional HPLC injector (direct-inject style). So an injection volume of 10 µl on a UPLC system can yield different area counts than an equivalent volume injected on an HPLC system. Full loop injections yield better recoveries (lower area-count 71500154206, Rev. A ACQUITY, ACQUITY UPLC, UPLC, and Waters are registered trademarks of Waters Corporation. ecord is a trademark of Waters Corporation. All other trademarks are the sole property of their respective owners. Copyright 2007 Waters Corporation. 1

losses) than those made using partial loop injection modes. If an appropriate sample loop is available (one with a characterized loop volume that matches your desired injection volume), Waters recommends using full loop injections when initially transferring an HPLC method to an ACQUITY UPLC system. If necessary, you can adjust injection volumes or change injection modes after the initial method transfer. See also: For information on available sample loop sizes, see the Waters Quality Parts Locator on the Waters Web site s Services/Support page. For more information on ACQUITY UPLC injection modes, consult the ACQUITY Console online Help. Requirements for using an HPLC column on an ACQUITY UPLC system Observe the following requirements when fitting an HPLC column on an ACQUITY UPLC system: When running columns without an ecord, verify that the console software is configured to ignore the absence of the ecord. See also: For information on how to enable/disable the ecord column chip requirement, consult the ACQUITY Console online Help. Install the column stabilizer. For 150-mm columns, use the optional 150-mm column stabilizer. See also: For detailed instructions on how to install the column stabilizer, consult the ACQUITY UPLC System Operator s Guide. 2

Two types of column stabilizer: Reusable fittings For 50-mm or 100-mm column For 150-mm column TP02875 Inlet tubing to injector Do not use the ACQUITY UPLC column in-line filter unit with an HPLC column. Set the high pressure limit of the ACQUITY Binary Solvent Manager to the maximum pressure recommended for the HPLC column. Recommendation: To reduce variability from temperature fluctuations, use a column oven with a thermostat. For columns longer than 150 mm, use the ACQUITY UPLC System 30-cm Column Heater/Cooler or another appropriate external oven. Tip: If you observe a discrepancy between the selectivity and resolution of the HPLC and UPLC methods, ensure that you properly compensated for system volume differences. If the discrepancy persists, adjust the temperature of the column heater by +/- 2 C and assess the result. Choosing fittings Column inlet TP02874 When connecting the column stabilizer to an HPLC column, choose among the following types of fittings: Use the Waters-supplied, reusable, UPLC fitting. Replace the three-piece Waters fitting with a one-piece, reusable fitting suitable for your pressure and temperature requirements. 3

Use a stainless-steel (swage) fitting recommended by the HPLC column manufacturer. Waters supplies a finger-tight, reusable fitting for connecting the column stabilizer to the column inlet. The fitting assembly consists of a ferrule (PEEK ), collet, and compression screw. Because the position of the ferrule is adjustable, you can use this fitting assembly with any style of column end-fitting. The column stabilizer reusable fitting: TP02846 Reusable fitting PEEK ferrule Outlet tube Variable distance Collet See also: For more information on replacing fittings and installing columns, consult the ACQUITY UPLC System Operator s Guide. If you prefer the convenience of a single-piece fitting, you can replace the three-piece Waters fitting with a single-piece fitting that meets your temperature and pressure requirements. Caution: To avoid leaks and connection failures, do not exceed the temperature or pressure limitations of your fittings. You can also use stainless-steel fittings recommended by your HPLC column s manufacturer. For stainless-steel fittings, the ferrule position remains fixed (swaged) once it is set. The distance from the ferrule to the end of the tubing when connected to a UPLC column is approximately 3 mm. Your HPLC column can require a different distance. Ensure that the distance between the ferrule and the end of the tubing is appropriate for the end-fitting of the column you are using. Band broadening and leaks can occur if the fittings are not properly seated. 4

Column outlet Requirements: If your system has a Waters-supplied, wrench-flat, column outlet fitting that has been used for a UPLC column connection, you must replace the swage fitting with a reusable fitting of your choice, or a swage fitting recommended by the HPLC column manufacturer. For all fittings, ensure that the distance between the ferrule and the end of the tubing is appropriate for the end-fitting of the HPLC column you are using. Wrench-flat column outlet fitting: Wrench-flat nut Tubing Ferrule Steel backing ring See also: For information on tubing and fittings for post-column tubing connections, consult the ACQUITY UPLC System Operator s Guide and the appropriate detector user documentation. 5