MineARC s TunnelSAFE Multi-Service Vehicle (MSV) Refuge Chamber

Similar documents
Chemical Safe Havens The MineARC ChemSAFE Standard Design Range

Standalone Scrubber. MineARC AirGEN Standalone Scrubber AG-35. Emergency refuge chambers and auxiliary mining products.

Coal Mine Change-Over-Stationg

Hard Rock Mine Refuge Chambers

Chemical Safe Havens. The MineARC ChemSAFE Utility Design Range

Dräger Mine Refuge Chamber MRC 5000 Innovative, portable life support system

Hard Rock Mine Refuge Chambers

Management System. Compressed p Air

Dräger ERS-Chamber Refuge Chambers

Dräger ERS-Chamber Refuge Chambers

Strata REFUGE Solutions. for MINES, TUNNELS, CHEMICAL PLANTS, & SURFACE OPERATIONS

Emergency shelters and effect on rescue plans

Refuge Chambers. Permanent. Permanent refuge solutions for underground safety zones, excavations and break/rest areas.

DRÄGER REFUGE SHELTERS. Light in the middle of the tunnel

Respiratory Protection

Chemical Safe Havens. The MineARC ChemSAFE Standard Design Range

Coda cx1 Thermal Cycle Test Procedure

Self-Rescue Equipment and Skill Development for Mine Escape

A. Evaluation of the written program

Installation, Operation, & Maintenance Manual NX Seal Cooler

Working in Gas Hazard Areas

IECEx Certificate of Conformity Annexe

Dräger Engineered Refuge Solutions Unmatched flexibility and mine safety

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS

TOWN OF LINCOLN ARENA FACILITIES OPERATIONAL SAFETY POLICY

Flex-Kleen CT Series Pulse-Jet Dust Collectors For high pressure/high vacuum applications

Drum / cylinder handling

Getting out safely Our escape solutions FILTERING ESCAPE EQUIPMENT COMPRESSED AIR EQUIPMENT OXYGEN SELF-RESCUER REFUGE CHAMBERS TRAINING & SERVICE

TYPICAL TOXIC GAS SYSTEM INSPECTION VIOLATIONS

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

Permit To Work. A permit to work system is designed to ensure that all necessary actions are taken before,during,and after most of task on plant.

CAUTION Hard copies of this document may not be the current version. Refer to the "I Am The Key" verify the current version,

UNDERGROUND REFUGE REFUGE CHAMBERS 2017

ROLE DESCRIPTIONS BY COMPETENCY LEVEL

SAMPLING SYSTEMS FOR LIQUIDS AND GASES FOR ALL TYPES OF APPLICATIONS

Texas Department of Insurance. Respiratory Protection. Provided by. Workers Health & Safety HS01-027B (1-06)

V-Major, V-Compact. Reciprocating Compressors. Intelligent Air Technology

Niltox Breathing Air Purifier Range

Petrochemical Safe Havens

Portable Oil Lube Air Compressors

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

Rockhampton Office Brisbane Office Tarong Site. Barron Gorge Hydro PS Kareeya Hydro PS Mica Creek PS

Summary of the MRA LPG Codes of Practice

RESPIRATORY PROTECTION PROGRAM

Dräger MRC 5000 Refuge Chambers

APPROVED MAIN COURSES

Confined Space Program

Technical equipment and operation for a refuge room in: Shaft Konrad Mine.

ALBUQUERQUE PUBLIC SCHOOLS RESPIRATORY PROTECTION PROGRAM

Mobile Breathing Air Systems

This test shall be carried out on all vehicles equipped with open type traction batteries.

The Austrian mine rescue service. Thomas Spörker Dublin, 9 th October 2014

High Pressure Compressed Air and Gas Solutions

Section J. How to develop safety elements for project safety management system. How to develop safety elements for project SMS

Confined Space in Construction

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

B-Series. breathing air systems flow capacity: scfm

Tool Box Talk. Confined Space Entry New Construction Standard (2015)

Key Technology, Inc. Confined Space Entry Program. July, 2017

Hazard Communication Program

Mount Holyoke College. Confined Space Program

Lockout. HealthandSafetyOntario.ca. What is Lockout? How is a Lockout Done? Why is a Lockout Necessary?

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

Drain Splash Back Burns Operator

3 Choosing the Right Respirator

This written Compressed Gas Plan is kept at the corporate office and in the written Safety & Health Program.

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

exceeds global breathing air quality standards B 1 breathing air systems flow capacity: scfm flow capacity: scfm ( Nm 3 /hr)

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Safety Manual Section 6 Confined Space

AIR TO BREATHE EVEN WHEN THINGS GET TOUGH. SAFETY AND RESCUE IN MINING AND TUNNEL CONSTRUCTION.

Safe Work Practices / Procedures / Instruction CONFINED SPACE

Emergency Refuge Chambers

Revisions Made? Yes No_X_

TABLE OF CONTENTS PART 2 - CONFINED SPACES

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

Part 18 Personal Protective Equipment

Personnel Protective Equipment

Drass. 700 Series Surface Diving System

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant

FXT. FXT Cooling Tower RIGGING & ASSEMBLY INSTRUCTIONS

Compressed Airline Breathing Apparatus

CONFINED SPACE PROGRAM

Scope: This plan applies to all personnel, including contractors, who enter or work in confined spaces, or supervise such activities.

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Position Number Community Division/Region Yellowknife North Slave

Hazardous Materials Management. Presented by. James E. Roughton, MS, CSP, CRSP, CHMM.

INSTRUCTION MANUAL FOR EBA MINUTE SELF-CONTAINED SELF RESCUER (SCSR) Manual Number: NH13747 Revision: A, ECN 2384 September 7, 2001

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

Challenges of Mines Rescue in Expanding Mine Operations

DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers


THE HOME OF BEAUTIFUL POOL DESIGN

Intrinsically safe solenoid valves on/off controls - ATEX certification

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

MEDICAL EQUIPMENT CATALOG

POTENTIAL HEALTH & SAFETY HAZARDS

HUMAN FACTORS CHECKLIST

Breathing Air Purifiers Comply with OSHA Grade D, NFPA-99, European Pharmacopoeia and other International Breathing Air Standards

Respiratory protective devices

Transcription:

MineARC s TunnelSAFE Multi-Service Vehicle (MSV) Refuge Chamber Davy Li

Contents MineARC: Leaders in Industrial Safety The TunnelSAFE Range The TunnelSAFE MSV Design Mobility & Driver Integration CO/CO2 Scrubbing Positive Pressure Maintenance System Custom Shapes & Layouts Extreme Temperature Control System Intelligence Project Stakeholders

MineARC: Leaders in Industrial Safety MineARC Systems is the global leader in the manufacture and supply of emergency safe refuge solutions for the mining, tunnelling, chemical processing and disaster relief industries. With over 15 years experience, our key focus on quality control, product advancement and our specialist knowledge and expertise has meant that MineARC Refuge Chambers have successfully saved lives in multiple real life tunnelling emergencies around the globe. MineARC s TunnelSAFE range of refuge chambers are highly customisable to suit any project and can be built to comply wih the ITA s Guidelines for the Provision of Refuge Chambers Under Construction and BSEN 16191.

The TunnelSAFE Range MineARC has developed a comprehensive TunnelSAFE range; designed to meet the needs of the industry at all stages of the project life-cycle and across all tunnelling techniques. Gantry Design Rail Design MSV Design Drill & Blast Design

MineARC s TunnelSAFE Multi-Service Vehicle (MSV) Design Based on industry demand, MineARC has developed the MSV Design Refuge Chamber, which is custom engineered and manufactured to be mounted to a multi-service vehicle. The MSV Design provides a portable safe haven for workers during routine tunnel inspections and maintenance works. First refuge chamber of its kind in the world Provides an advantage over traditional refuge chambers due to its mobility The ability to be able to control the vehicle from within the refuge chamber means that all personnel, including the driver, are safe for the duration of the journey.

Mobility & Driver Integration TunnelSAFE MSV s have been specifically designed as a mobile unit in order to provide a safe means of escape in an emergency. Can be fitted with the client s own remote control system, allowing the vehicle to be operated from within the refuge chamber. Custom engineered mounting points to specifically match the client s MSV, allowing easy bolt-on installation. Can be designed with a driver control panel at both ends, allowing the MSV to be driven in either direction.

CO / CO2 Scrubbing TunnelSAFE Chambers use active chemicals and MineARC's Extra-Low- Voltage (ELV) Scrubbing System to scrub the build-up of harmful CO2 and CO from the air inside the refuge chamber. Operational hub of the chamber that controls power, lighting and scrubbing MineARC s MARCISORB Chemical Cartridges provide superior scrubbing capacity

Positive Pressure Maintenance System (PPMS) The MineARC PPMS is a unique piece of equipment, designed to help maintain a safe, breathable atmosphere within the refuge chamber. Securely mounted to the interior wall of the chamber, and powered by a 24VDC power supply, Electric solenoid valve opens and closes to release measured amounts of breathable air from compressed air cylinders in order to maintain a positive internal pressure in the chamber. Quantity of breathable air cylinders is configurable to suit various internal volumes and durations of operation.

Custom Shapes & Layouts All aspects of the TunnelSAFE MSV Design can be customised by MineARC Engineers to suit most project specifications, therefore no two chambers are the same. Shape Standard dimensions Blast resistance Internal volume Occupancy Entry style Minimum entrapment duration

Extreme Temperature Control MineARC has developed several temperature control upgrades for tunnelling projects that experience high ambient temperatures. Self-contained Misting System assists in heat suppression of the external environment by emitting a fine mist of water around the exterior of the chamber. This mist flashevaporates under high temperatures, creating a temperature barrier around the chamber. High ambient air conditioning system designed to function effectively in ambient temperature conditions of up to 50 C.

Stakeholders Engineer: Client: Contractor: Errol Hassett MineARC driven initiative. Projects sold to include Brenner Base Tunnel Project (Austria) & Lyon-Turin Tunnel Project (France). None MineARC driven initiative.