QUICK START GUIDE CB-150 DATA BUOY PLATFORM

Similar documents
QUICK START GUIDE CB-450 DATA BUOY PLATFORM

QUICK START GUIDE CB-950 DATA BUOY PLATFORM

CB-150 Data Buoy Quick Start Guide

CB-50 Data Buoy Quick Start Guide

CB-40 Data Buoy Quick Start Guide

ENVIRONMENTAL DATA BUOYS

I.H.S INSTALLATION INSTRUCTIONS

Assembly Instructions. -Cantilever Boat Lifts

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

Pressure Dump Valve Service Kit for Series 2300 Units

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

Low Wind High Yields Series

OEM Manual. MODEL ½ Digit DRUM SCALE

Pressure Dump Valve Service Kit for Series 3000 Units

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

CLIENT NAME: LOCATION: CALM BUOY INSPECTION:

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

222 Schwinn Recumbent Exercise Bike Parts List Full Size Hardware Chart Product Illustration Assembly Instructions

Installation Instructions MODEL VSTI-A020 Tank Indicator Installation Model: VSTI-A020, Stainless Reverse Read System Versa Steel Inc. Guide Cables No

INSTRUCTION MANUAL. January 23, 2003, Revision 0

Preferred Instruments Danbury, CT USA

High-performance submersible pressure transmitter For level measurement Model LH-10

Lectric Cycles Mid-Drive Electric Motor Installation

Technical Bulletin. Parts and Service News. LPG Lock-Off valve replacement procedures for 4.2 Liter Ford V6

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup.

GV Standard X-Vent. Setup, Commissioning & Installation Guide

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Advantage Lockers & Bike

SonoMeter 30 Energy Meters

Tripod Setup Guide (M-TPx)

MODEL DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT

MODEL ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT

GasSense NDIR User Manual

CSBUOY-DT INSTRUCTION MANUAL

Gerber Sabre 404 and 408 Installation Instructions

WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination

RPS900W Redundant Power Supply. Installation Guide.

WELL COMPLETION & PROTECTION. www. .com MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD

INSTRUCTION MANUAL. FLOAT TYPE LEVEL TRANSMITTER HT-100R Series HITROL CO., LTD.

Model PSI Compressor with 3-Gallon Air Tank 12VDC

RAI-M series RUDDER ANGLE INDICATOR SYSTEM

NOVALYNX CORPORATION MODEL ANALOG OUTPUT EVAPORATION GAUGE INSTRUCTION MANUAL

SDX Submersible Depth Transmitter User Manual

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

Ocean Observatories Initiative. Coastal & Global Scale Nodes. Hydrogen Safety. OOI Surface Mooring Hydrogen Safety Review

TRANSDUCER KIT 2 INSTALLATION INSTRUCTIONS

MODEL 9875 STADIUM BASEBALL SCOREBOARD. Instruction Manual

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

Operator s Safety Manual Sumner Max Jax / Beam Jax

NHR-X-X Encore Feed Hoppers

Procedure Troubleshooting the Interconnect Cables

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

User s Guide. Vacuum Controller for liquid delivery systems

Shoreline Cantilever Lift 2500lb Capacity Models: (108" inside width) - Part # (120" inside width) - Part #

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES

NHR Powder Feed Hopper

High-performance submersible pressure transmitter For level measurement Model LH-10

QUALITY ALUMINUM BOAT LIFTS, INC. INSTRUCTIONS. Dominator Lake Lift

5 Channel Calibrator

Installation Instructions

Table of Contents 1 Introduction 2 Technical specifications 3 Included in the delivery 4 Function description 5 Mounting Nortek AOS buoy

Installation, operating and maintenance Instructions for Seemag bypass level indicator

TRI-POD SETUP. Guidelines for Typical Field Setup. Site Selection

Foundation Products. Poured In Ground Anchor Bolts E1 - E4. Structural Foundations E5 - E12. Copyright 2016 s Industry Inc. SIE-RA-CMP EN

Chapter 2 Rigging. Cutting Wire Rope. Anchoring Wire Rope to Drum. Winding Wire Rope Onto Drum

BUTTERFLY VALVES Series 800

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Expert Hydrostatic Level Transmitters

SDX Submersible Depth Transmitter User Manual

Technical Information Conducal CLY421

AUTO PUMP STATUS CENTER

TOYOTA TACOMA 2005 TOW HITCH Preparation. Part Number: PT

BUYER S GUIDE AQUAlogger 520

8MAY15 US RACK, Inc Falcon Drive, Madera, CA

Columbus Instruments

SECTION 2 RING MOUNT

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

Installation Instructions

Pressure Measurement Single-range transmitters for general applications

Parts Manual STRIKER Striker 2840 Parts List - PN Printed in USA 03/18/08

Backboard and Rim Owners Manual

Encore PE 50-lb Feed Hopper

Model 10E Enviro-Line Environmental Pressurization System Installation & Operation Manual

Stand-Alone Bubble Detection System

ATOC Meteorological Tower (6 meter-4 level) Guide

SITRANS P measuring instruments for pressure

9A5N Solid State CW Paddle

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

SVS MINI 4 LIFT INSTALLATION INSTRUCTIONS (220V)

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

#59114 Rola 2-Bike Rack Carrier (Shown Assembled) (A) (C) (B)

Pneumatic spool valve islands

BELT DRIVE INDOOR CYCLING BIKE SF-B1712 USER MANUAL

Pneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar)

MANITOWOC MODEL TON CAPACITY

DPC-30 DPC-100. Reference Manual

Model 6810A Dual Lane Scoreboard Owner s Manual Rev B

Transcription:

What s Included (1) Buoy hull with data well, 150 lb buoyancy (1) Buoy tower (3) 6W Solar panels (1) Data well lid (isic-cb or pass-through) (3) Top-side lifting eyes (3) Bottom-side mooring eyes Common Accessories isic-cb data logger enclosure RTU-R/C/I telemetry module CB-A01-2 battery harness/regulator assembly, (2) x 8.5 A-Hr batteries CAGE Instrument cage M550-P-Y LED beacon 912M 2 sensor deployment pipes CB-PW-AC-30W battery charger Assembly Overview Figure 1: CB-150 Data Buoy Overview The NexSens CB-150 data buoy platform is constructed with a closed cell, cross-linked polyethylene foam hull with polyurea coating that provides 150 lb buoyancy. The buoy has a corrosion resistant, stainless steel internal frame with topside lifting eyes and subsurface mooring eyes for connection of single-point and multipoint mooring systems. An integrated data well located within the buoy hull accommodates batteries and electronics. The data well lid is available as a NexSens isic-cb data logger assembly or as a standard lid with pass-through fittings for use with user-supplied electronics. Internal batteries are recharged by (3) 6-Watt solar panels mounted on the buoy tower, which also supports an optional LED beacon and RTU-R/C/I radio, cellular or Iridium satellite telemetry module. The main components of the CB-150 data buoy platform are assembled at the time of shipment. Installation of accessories may be required. Quick instructions are provided in this guide. Visit the online Knowledge Base for more information (see Additional Information section). Instrument Cage Use the provided ¾ bolt, lock washer and castle nut to attach the cage to the buoy frame. Tighten very firmly with a pair of 1-1/8 or crescent wrenches. Figure 2: Instrument Cage Installation Ensure that the lock washer is flattened and the hole in the bolt lines up with the notches in the castle nut. A large amount of force may be necessary to properly align the nut. 1

Figure 3: Castle Nut Alignment Place the cotter pin through the hole in the bolt, and bend the long leg of the pin to prevent the cage from loosening. Figure 6: Top Plate Removal Use the provided bolt, lock washer and flat washer to secure the beacon mounting post to the top plate. Tighten so that the lock washer is flat and the mounting post is secure but do not use excessive force. Figure 4: Castle Nut Installation Welding the cage and/or installing additional security straps is also recommended for use in rough water. If using a CB-CCA cage clamp accessory to prevent rotation and loosening, follow the instructions provided with the clamp for installation. Figure 7: Attached Beacon LED Beacon Figure 5: Cage with CB-CCA Clamp Use a 9/16 socket or crescent wrench to remove the top plate (with RTU-R/C/I module if present) from the buoy. Disconnect the RTU cable from the buoy COM port to remove the plate. Deployment Pipe The bottom of the buoy hull includes (3) 2 female threaded couplings for connection of NexSens 912M deployment pipe assemblies or other PVC fittings. To use these ports, simply thread each deployment pipe securely into one of the available couplings. Instruments deployed in 912M pipes can easily be accessed for calibration and maintenance by removing the port cover plate from the top of the buoy hull. Use a 5/16 Allen/hex key to remove the pair of screws on the cover plate. 2

Wiring & Device Connections NexSens isic-cb Data Well Lid each other if both are connected to P0. RS-485 and SDI-12 ports are shared throughout the bus. For systems using NexSens electronics for data acquisition and telemetry, the isic data logger is housed in an isic-cb enclosure that provides a watertight seal over the data well. The bottom of the isic-cb has a power plug that connects to a CB-A01-2 battery/solar regulator assembly. The top of the isic-cb enclosure has a series of UW ports for connection of solar panels, sensors, communication devices, and external power supplies to the isic. The available ports and functions are: - (5) SENSOR (P0/P1/P2): NexSens sensorbus architecture includes wiring for SDI-12, RS- 232 and RS-485 devices. For compatibility, sensors must have a factory-installed UW plug connector. The sensor ports are wired as follows: (2) P0: 12V full power, shared RS-232 port. (2) P1: 12V switch power, shared RS-232 port. (1) P2: 12V switch power, unique RS-232 port. - (1) COM: Communications port for isic data logger configuration and data acquisition through UW-USB-232P-NP cable or RTU-R/C/I radio, cellular, or Iridium satellite telemetry module. - (1) SOLAR: 6-pin input for solar panel to apply system power and charge internal battery. Solar cable or a specialized UW plug with jumper (P/N UW-JUMPER) must be connected to SOLAR port to power the isic. - (1) VENT: Gortex vent for relief of outgassing pressure during recharge of batteries located in the data well. In heavy wave conditions, this vent can be plumbed with tubing to the top of the tower. The sharing of serial ports on P0 and P1 means that only one non-addressable device can be connected at a time. For example, two devices with RS-232 NMEA0183 output will interfere with Figure 8: isic-cb Enclosure Devices with analog outputs (e.g. 4-20 ma, 0-2.5 VDC) may be connected to the isic-cb through a mv-rs485 adapter, which converts the analog signal to RS-485 Modbus. The mv-rs485 adapter must be programmed for the specific sensor connected. See the instructions provided with the adapter for more information. Figure 9: mv-rs485 Adapter 3

Table 1 shows the sensorbus signal for each pin on the UW receptacle ports of the isic-cb. The pins are numbered based on the diagram in Figure 10 (plug pins are 1-4, socket pins are 5-8). The table also lists the corresponding wire color for a UW plug to flying lead cable connected to a port (see Figure 11). The system battery voltage can be checked externally by placing the leads of a voltmeter on pins 4 (red) and 7 (black) of a P0 or COM port. Table 1: UW Receptacle sensorbus Wiring UW Receptacle Pin Wire Color sensorbus Signal 1 Green RS-485 A 2 Blue RS-485 B 3 Brown SDI-12 4 Red 12V Power 5 White 5V Power 6 Yellow RS-232 Rx 7 Black GND 8 Orange RS-232 Tx Figure 11: UW Plug to Flying Lead Cable Pass-Through Data Well Lid For applications with user-supplied sensors, data loggers, telemetry modules and/or batteries, the CB-150 data buoy is provided with a data well lid with a set of plugs and pass-through fittings for securing user-supplied instrument cables. The lid includes the following ports: - (6) PASS-THROUGH: Blank UW receptacles supplied with a set of plugs for sealing unused ports and a set of fittings for securing instrument cables going into the data well. - (1) SOLAR: 6-pin port for connection of solar panel assembly. Includes connector inside data well for use with optional CB-A01-2 battery/solar regulator harness. For use with user-supplied battery/regulator systems, see Solar Power Wiring. - (1) VENT: Gortex vent for relief of outgassing pressure during recharge of batteries located in the data well. Tighten the fittings securely around cables routed into the data well to maintain the watertight seal. Plug all ports that are not used. Figure 10: UW Connector Pinout 4

For a more robust connection at the data well plate, the pass-through ports may be fitted with UW-BULK bulkhead receptacle connectors. The UW-BULK assembly has the same pinout as isic- CB sensor ports (see Table 1), but the cable terminates in flying leads for integration with a user-supplied data logger. The device connected must have a factory-installed UW connector. Figure 12: UW-Bulkhead Connector Assembly Solar Power Wiring Figure 13 shows a schematic drawing for the wiring of the CB-150 power supply. The system includes (3) 6-watt solar panels that connect through the data well SOLAR port to a CB-A01-2 or user-supplied battery/solar regulator harness. A wire lead is provided to supply 12V DC power to electronics inside the data well (red = +12V, black = GND). Figure 13: Wiring Schematic *NOTE: The 12V power supply leads for user supplied electronics will only supply power when the solar panel is plugged into the SOLAR port on the data well lid, even if a battery is connected inside the data well. To supply battery power without plugging in the solar panel, a special UW plug with internal jumper is available (P/N UW- JUMPER). For systems with user-supplied battery and solar regulator, the battery and regulator can be connected through the 4-pin Molex connector or by cutting the wires at section A-A in Figure 13 and splicing the connections. In these situations, reference the signals listed in Table 2. 5

Table 2: Wiring for user-supplied battery/regulator Signal Wire Color +12V Red GND Black The buoy data well is not rated for submersion, so proper ballast weight is critical to ensure that the buoy does not overturn, including when the buoy is subjected to additional loading (e.g. high wind/waves, periodic snow/ice loads, etc.). Solar input Charge output Yellow Orange Ballast Weight and Stability To prevent overturning of a CB-150 buoy system and to ensure that it is stable in the water, additional ballast weight may be needed. The center of gravity of the buoy is somewhere near the water surface without instruments connected. Any weight added above the water surface must be appropriately counterbalanced by adding ballast weight below the surface. The larger the distance from the location of added weight to the center of gravity, the greater the effect on the stability of the buoy will be. For example, if a weather sensor is mounted 36 above the water surface, it will cause more instability than if it were mounted 24 above the surface and, as a result, would require more subsurface ballast weight to counterbalance the buoy. Conversely, a ballast weight added further below the surface will provide a greater stabilizing effect than the same size weight mounted closer to the surface. An instrument cage mounted to the buoy frame helps to stabilize the buoy and provides a deeper location for mounting additional weight. For single-point mooring configurations, mooring chain and lines connected to the bottom of the cage may provide adequate ballast. For multipoint configurations, the mooring hardware does not contribute to the ballast weight. Before deployment of a CB-150 system, some experimentation may be required to properly balance the buoy. If needed, add ½ chain (~2.3lb/ft) or other weight to the bottom of the cage. Figure 14 shows an example of a buoy system with a short section of chain added. Figure 14: CB-150 Data Buoy with Ballast Chain Saltwater Deployment Sacrificial zinc anodes should be used whenever a buoy is deployed in a saltwater environment to prevent corrosion. These zinc anodes must be inspected and replaced as needed. Mooring Configurations This section contains only general information on the available mooring options for CB-150 data buoys. To develop an effective mooring strategy, a variety of application-specific criteria (water level fluctuations, currents and wave action, debris loads, etc.) must be thoroughly reviewed prior to deployment. NexSens does not endorse any particular mooring strategy for any specific application. 6

Single-Point Mooring Single-point moorings are used in calm waters when monitoring sensors are attached to the instrument cage or housed in deployment pipes. The sensors are thus protected and less vulnerable to damage caused by subsurface debris, high currents, and entanglement from anchor lines. In a single-point configuration, a stainless steel mooring line connects the buoy directly to a bottom chain and anchor. At normal pool/stage, the mooring line should be taut, with most of the bottom chain resting on the floor of the water body. As the water level increases and the buoy rises, the bottom chain is lifted from the floor. buoy, freeing the water column for a suspended sensor line. In most two-point configurations, mooring lines connect the data buoy to small marine marker floats, often located on the water surface. These marker floats are shackled to another mooring line that runs to the floor and connects to a bottom chain and anchor assembly. Additional subsurface marker floats may also be used in some applications. As in single-point systems, the bottom chain prevents buoy submersion as the water level fluctuates. Figure 16: Typical Two-Point Mooring Configuration Figure 15: Typical Single-Point Mooring Configuration Two-Point Mooring Two-point moorings are commonly used when monitoring sensors are deployed in the water column below the buoy. In this setup, the mooring lines are pulled taut away from the Safe Deployment Personnel safety is the number one priority when deploying a data buoy. Use of proper equipment (work boat, lifting rig, gloves, safety footwear, etc.) is essential to safely deploy any buoy system. Buoy systems are heavy and personnel can quickly become entangled with mooring lines and anchors. Safety and flotation gear should be worn at all times when working on or near the water. Remember to perform a complete system test on shore prior to deployment. Learning the nuances of the system is much better handled on shore or in a lab rather than in the field. 7

Specifications Hull Dimensions: 24 (60.96cm) outside diameter; 14 (35.56cm) tall Tower Dimensions: 13 (33.02cm) tall, triangular Data Well Dimensions: 10.3 (26.16cm) inside diameter; 13.5 (34.29cm) tall Weight: 95 lbs. (43.09 kg) Buoyancy: 150 lbs. (68.04 kg) Hull Material: Cross-linked polyethylene foam with polyurea coating & stainless steel deck Hardware Material: 304 stainless steel Mooring Attachments: 1- or 2-point, ¾ eye nut Solar Power: (3) 6-watt, 12VDC solar panels Additional Information Additional information and complete instructions for the CB-150 data buoy platforms are available in the NexSens online Knowledge Base: http://www.nexsens.com/knowledge-base http://www.nexsens.com/category/knowledgebase/data-buoys/cb-150-buoy 8