CYCLE ANALYSIS OF LINEAR COMPRESSORS USING THREE- DIMENSIONAL CFD

Similar documents
Numerical Simulation for the Internal Flow Analysis of the Linear Compressor with Improved Muffler

A Numerical Simulation of Fluid-Structure Interaction for Refrigerator Compressors Suction and Exhaust System Performance Analysis

Domain Decomposition Method for 3-Dimensional Simulation of the Piston Cylinder Section of a Hermetic Reciprocating Compressor

Investigation of failure in performance of linear compressor & its rectifications

Predicting the Suction Gas Superheating in Reciprocating Compressors

Simulator For Performance Prediction Of Reciprocating Compressor Considering Various Losses

The Estimation Of Compressor Performance Using A Theoretical Analysis Of The Gas Flow Through the Muffler Combined With Valve Motion

Application of Computational Fluid Dynamics to Compressor Efficiency Improvement

Proceedings of the ASME th Biennial Conference on Engineering Systems Design and Analysis ESDA2014 June 25-27, 2014, Copenhagen, Denmark

Purdue e-pubs. Purdue University. Stephan Lehr Technische Universitaet Dresden. Follow this and additional works at:

CFD Simulation and Experimental Validation of a Diaphragm Pressure Wave Generator

Investigation of Suction Process of Scroll Compressors

Capacity Modulation of Linear Compressor for Household Refrigerator

A Research on the Airflow Efficiency Analysis according to the Variation of the Geometry Tolerance of the Sirocco Fan Cut-off for Air Purifier

CFD Analysis and Experiment Study of the Rotary Two-Stage Inverter Compressor with Vapor Injection

Modelling And Analysis of Linear Compressor

Two-way Fluid Structure Interaction (FSI) Analysis on the Suction Valve Dynamics of a Hermetic Reciprocating Compressor

Acoustical Modeling of Reciprocating Compressors With Stepless Valve Unloaders

MODELING AND SIMULATION OF VALVE COEFFICIENTS AND CAVITATION CHARACTERISTICS IN A BALL VALVE

Gas Vapor Injection on Refrigerant Cycle Using Piston Technology

Using PV Diagram Synchronized With the Valve Functioning to Increase the Efficiency on the Reciprocating Hermetic Compressors

Improvement of the Volumetric and Isentropic Efficiency Due to Modifications of the Suction Chamber

Correlation Between the Fluid Structure Interaction Method and Experimental Analysis of Bending Stress of a Variable Capacity Compressor Suction Valve

Efficiency Improvement of Rotary Compressor by Improving the Discharge path through Simulation

Two-Stage Linear Compressor with Economizer Cycle Where Piston(s) Stroke(s) are Varied to Optimize Energy Efficiency

A Numerical Study of the Performance of a Heat Exchanger for a Miniature Joule-Thomson Refrigerator

CFD Simulation of the Flow Through Reciprocating Compressor Self-Acting Valves

Research of Variable Volume and Gas Injection DC Inverter Air Conditioning Compressor

Cooling Characteristics of GM-type Pulse Tube Refrigerator with Neon as Working Gas

Numerical analysis of gas leakage in the pistoncylinder clearance of reciprocating compressors considering compressibility effects

Performance Analysis of Centrifugal Compressor under Multiple Working Conditions Based on Time-weighted Average

Compressors. Basic Classification and design overview

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

An Experimental and Numerical Analysis of Refrigerant Flow Inside the Suction Muffler of Hermetic Reciprocating Compressor

INDIAN INSTITUTE OF TECHNOLOGY ROORKEE NPTEL NPTEL ONLINE CERTIFICATION COURSE. Refrigeration and Air-conditioning

A Simplified CFD Model for Simulation of the Suction Process Of Reciprocating Compressors

Numerical Fluid Analysis of a Variable Geometry Compressor for Use in a Turbocharger

Linear Compressor Discharge Manifold Design For High Thermal Efficiency

Oil-Lubricated Compressors for Regenerative Cryocoolers Using an Elastic Membrane

Noise Characteristics Of A Check Valve Installed In R22 And R410A Scroll Compressors

Performance analysis of reciprocating compressors through computational fluid dynamics

Single Phase Pressure Drop and Flow Distribution in Brazed Plate Heat Exchangers

Fluid-Structure Interaction Analysis of a Flow Control Device

Analysis of Pressure Rise During Internal Arc Faults in Switchgear

Effect of Diameter on the Aerodynamics of Sepaktakraw Balls, A Computational Study

An Investigation of Liquid Injection in Refrigeration Screw Compressors

An Investigation on the Performance Characteristics of a Centrifugal Compressor

CFD Flow Analysis of a Refrigerant inside Adiabatic Capillary Tube

THEORETICAL EVALUATION OF FLOW THROUGH CENTRIFUGAL COMPRESSOR STAGE

Effect of Inlet Clearance Gap on the Performance of an Industrial Centrifugal Blower with Parallel Wall Volute

Free Surface Flow Simulation with ACUSIM in the Water Industry

Incorporating 3D Suction or Discharge Plenum Geometry into a 1D Compressor Simulation Program to Calculate Compressor Pulsations

Linear Compressor Suction Valve Optimization

Comparative Analysis of Two Types of Positive Displacement Compressors for Air Conditioning Applications

Influencing Factors Study of the Variable Speed Scroll Compressor with EVI Technology

Influence of rounding corners on unsteady flow and heat transfer around a square cylinder

Design Optimization for the Discharge System of the Rotary Compressor Using Alternative Refrigerant R410a

An Impeller Blade Analysis of Centrifugal Gas Compressor Using CFD

Ermenek Dam and HEPP: Spillway Test & 3D Numeric-Hydraulic Analysis of Jet Collision

Influence of the Main Parameters of the Suction Valve on the Overall Performance of a Small Hermetic Reciprocating Compressor

OPTIMIZING THE LENGTH OF AIR SUPPLY DUCT IN CROSS CONNECTIONS OF GOTTHARD BASE TUNNEL. Rehan Yousaf 1, Oliver Scherer 1

Digital Computer Simulation of a Reciprocating Compressor-A Simplified Analysis

Performance Analysis of a Twin Rotary Compressor

NUMERICAL MODELING OF A REFRIGERATION RECIPROCATING COMPRESSOR

University of Strathclyde, 16 Richmond Street, Glasgow G1 1XQ, Scotland, United Kingdom

A Chiller Control Algorithm for Multiple Variablespeed Centrifugal Compressors

Research and optimization of intake restrictor for Formula SAE car engine

Effect of Coiled Capillary Tube Pitch on Vapour Compression Refrigeration System Performance

A CFD Study on the Mechanisms Which Cause Cavitation in Positive Displacement Reciprocating Pumps

Optimization of Ejector's Performance With a CFD Analysis. Amanda Mattos Karolline Ropelato Ricardo Medronho

Two-stage pulse tube refrigerator with step displacer as phase shifter

International Journal of Advance Engineering and Research Development DESIGN CALCULATIONS TO EVALUATE PERFORMANCE PARAMETERS OF COMPRESSOR VALVE

Centre for Offshore Renewable Energy Engineering, School of Energy, Environment and Agrifood, Cranfield University, Cranfield, MK43 0AL, UK 2

CFD SIMULATIONS OF GAS DISPERSION IN VENTILATED ROOMS

CFD Study of Solid Wind Tunnel Wall Effects on Wing Characteristics

Numerical simulation and analysis of aerodynamic drag on a subsonic train in evacuated tube transportation

Grid Generation for Screw Compressors with Variable Geometry Rotors

OPTIMIZATION OF SINGLE STAGE AXIAL FLOW COMPRESSOR FOR DIFFERENT ROTATIONAL SPEED USING CFD

Study on the Influencing Factors of Gas Mixing Length in Nitrogen Displacement of Gas Pipeline Kun Huang 1,a Yan Xian 2,b Kunrong Shen 3,c

COMPARISONS OF COMPUTATIONAL FLUID DYNAMICS AND

Numerical Simulations of a Train of Air Bubbles Rising Through Stagnant Water

Small Variable Speed Hermetic Reciprocating Compressors for Domestic Refrigerators

A COMPUTATIONAL STUDY ON THE DESIGN OF AIRFOILS FOR A FIXED WING MAV AND THE AERODYNAMIC CHARACTERISTIC OF THE VEHICLE

Analytic and Experimental Techniques for Evaluating Compressor Performance Losses

Updated Performance and Operating Characteristics of a Novel Rotating Spool Compressor

Vibration-Free Joule-Thomson Cryocoolers for Distributed Microcooling

Wind pressure coefficient determination for greenhouses built in a reclaimed land using CFD technique

Analysis of pressure losses in the diffuser of a control valve

67. Sectional normalization and recognization on the PV-Diagram of reciprocating compressor

Using Computational Fluid Dynamics as a Compressor Design Tool

Cryogenic Engineering Prof. M. D. Atrey Department of Mechanical Engineering Indian Institute of Technology, Bombay

A 3-D Transient CFD Model of a Reciprocating Piston Compressor with Dynamic Port Flip Valves

Development of Technology to Estimate the Flow Field around Ship Hull Considering Wave Making and Propeller Rotating Effects

Surrounding buildings and wind pressure distribution on a high rise building

NUMERICAL INVESTIGATION OF PRESSURE DROP IN HYDRAULIC SPOOL VALVE

Modeling of Scroll Compressor Using GT-Suite

Design and Static Structural Analysis of Cylinder and Piston of Two Stage Reciprocating Compressors Using ANSYS

THE PERFORMANCE OF PLANING HULLS IN TRANSITION SPEEDS

A COMPARATIVE STUDY OF MIX FLOW PUMP IMPELLER CFD ANALYSIS AND EXPERIMENTAL DATA OF SUBMERSIBLE PUMP

Measurement and simulation of the flow field around a triangular lattice meteorological mast

Transcription:

CYCLE ANALYSIS OF LINEAR COMPRESSORS USING THREE- DIMENSIONAL CFD I. Y. An and Y. L. Lee Department of Mechanical Engineering, Kongju National University, Korea E-Mail: ylee@kongju.ac.kr ABSTRACT In order to improve the efficiency of the refrigeration cycle or the heat pump cycle, it is important to improve the efficiency of a compressor. In this study, the authors intended to develop a three-dimensional numerical model that can predict the performance of a linear compressor. For this purpose, CFD model which can simulate the entire cycle was developed. The numerical analysis on the cooling capacity of two linear compressors was successfully conducted and the numerical results were in good agreement with the experimental results. In future, if considering the detailed valve behavior, the accuracy of the numerical analysis model can be further improved. Keywords: linear compressor, cooling capacity, CFD, cycle analysis. INTRODUCTION Refrigerators, air conditioners and heat pumps, etc. using a refrigeration cycle are providing various conveniences and the comfort of life. However, these products require much electric energy, and in particular, the refrigerator uses about 20-40% of the electric energy used in the home. In addition, the compressor constituting the refrigerator consumes about 80% of the total electricity required by the refrigerator [1]. Thus, improving the compressor efficiency can be an efficient way to save energy. The reciprocating compressor having high reliability and good efficiency has been commonly used as the compressor for a refrigerator or a heat pump long. However, because the efficiency of the reciprocating compressor is relatively low, the need for higher efficiency compressor is increasing. One of such high-efficiency compressors is just the linear compressor. Since the linear compressor uses the magnet with high magnetic force as a motor, the crank structure required in the reciprocating compressor does not need. This linear compressor has about 24% higher efficiency in comparison with the reciprocating compressor since it has not only small friction loss and wear but also low flow resistance [2]. Many studies have been conducted since the linear compressor has higher efficiency than the reciprocating compressor. Kim and Jeong [3, 4] have studied the performance characteristics of ICM (Inherent Capacity Modulated) linear compressor for the refrigerator through the numerical analysis and the experiments, and Kim et al., [5] have studied the dynamic characteristics with the numerical analysis and the experiments. Bradshaw et al., [6] have studied on the comprehensive model of the small linear compressor for electronics cooling, and Chen et al., [7] have studied on the magneticfield distribution of the linear motor. Tsai and Chiang [8] have studied on MLLA (Magnetically Levitated Linear Actuator) of the linear compressor through the numerical analysis and the experiments, and Yang and Huang [9] have studied on the double fuzzy regulators for the phase or the stroke of the linear compressor of the Stirling cryogenic refrigerator. However, the development of a higher efficiency linear compressor is necessary in accordance with the needs of consumers such as more various design, specialized functions and large capacity. Recently, the need for the flow optimization of the linear compressor using CFD (Computational Fluid Dynamics) has arisen to further improve the efficiency. In this study, the numerical model that can simulate the entire cycle of the linear compressor including compression and expansion processes has been developed. Then, the numerical analysis on the cooling capacity of two linear compressors was conducted, and the numerical model was verified through the experiments. Therefore, this numerical model can be successfully used for further improving or optimizing the performance of a linear compressor. Fluent [10] was adopted for CFD simulations with user defined functions. NUMERCAL ANALYSIS AND EXPERIMENTAL METHODS Governing equations and mesh system The flow of the fluid considered in this study is three-dimensional, compressible and unsteady, and realizable k-ε turbulent model proposed by Shinh et al., [11] was used. In addition, the standard wall functions proposed by Launder and Spalding [12] were used for the near-wall treatment. The Reynolds Averaged Navier- Stokes (RANS) equation and the energy equation used in the numerical analysis can be found elsewhere. [10] Figure-1 shows the mesh system for the flow analysis of the linear compressor model. Since threedimensional, compressible, unsteady and turbulent flow requires generally lots of computing time, the number of cells for the numerical model was minimized as possible. In this case, about 120, 000 cells were used in the model- 1, and 170, 000 cells were used in the model-2. Also, the hybrid mesh system that consists of tetrahedral, 874

hexahedral, prism and pyramid cells was used as shown in Figure-2. Cycle modeling of linear compressors The numerical analysis has been performed over the entire cycle including the compression and expansion processes. Initially the piston is located at BDC (Bottom Dead Center), and the piston moves by 12.4mm compressing the cylinder when the suction valve and the discharge valve are closed. Next, the discharge valve opens and discharges the refrigerant, and the discharge valve, then, is closed again while it reaches the TDC (Top Dead Center). Thereafter, the expansion process starts and the suction valve opens when the pressure of the cylinder becomes low enough, allowing the refrigerant to flow into the cylinder. Finally, when the piston reaches the BDC, the suction valve is closed and a whole cycle is over. The numerical analysis repeats this cycle. Figure-3 shows the cutting planes of two compressor models used in the numerical analysis. The two models are different each other in terms of piston movement. In the case of model-1, the copper pipe connected from the evaporator is fixed inside the piston, and because there is the gap between the piston and the pipe, the cylinder is compressed only by the piston movement. On the other hand, in the case of the model-2, the cylinder is compressed by both movements of the piston and the pipe since the piston and the pipe are stuck each other as an integral system. The opening time of the discharge valve was assumed as the moment that the pressure of cylinder becomes greater than 416.030 Pa during the compression process. In the numerical analysis, the boundary condition of the discharge valve was simply changed from wall to pressure outlet. After that, when the piston is reached the TDC, the boundary condition of the discharge valve is changed back from pressure outlet to wall. The opening time of the suction valve was assumed as the moment that the cylinder side pressure of the suction valve becomes smaller than the piston side pressure. The boundary condition of the suction valve is changed from wall to interior and consequently the refrigerant can be flowed into a cylinder. And then, when the piston is again reached BDC, the suction valve is closed. Opening and closing times of the suction valve and the discharge valve during a cycle are summarized in Table-1. Table-1. Cycle events modeling. Events Events conditions BC change Open discharge valve If P@cylinder 416,030Pa Wall Pressure outlet Close discharge valve If TDC Pressure outlet Wall Open suction valve If P@svalve_cyl_side P@svalve_piston_side Wall interior Close suction valve If BDC Interior Wall (a) Model-1 Figure-1. Mesh system for linear compressors. (b) Model-2 875

Figure-4. Dynamic layering [13]. Figure-2. Mesh at the cross section. Figure-5. Experimental apparatus [6]. The fluid assumed in the numerical analysis is the isobutene (R600a) which is one of the real gas models provided by NIST (National Institute of Standards and Technology) (14) and it was assumed that the inlet pressure is 48,550 Pa, the discharge pressure 416, 030 Pa, the minimum clearance between the cylinder and the piston 0.04mm and the number of frequency 56.5 Hz. Also, the cooling capacity Q CC in the numerical analysis was calculated from equation (1). Q CC = m avg (h 1 -h 4 ) (1) Figure-3. Cross sections for linear compressors. Dynamic mesh method In this study, the layering method among dynamic mesh methods was adopted in order to analyze the performance of the linear compressor. The layering method adds and removes layers of cells adjacent to a moving boundary, based on the height of the layer adjacent to the moving surface as shown in Figure-4. This technique is considerably accurate to describe the behavior of the linear compressor that repeats a simple, linear motion. Equation (2) and (3) show the split and the merge relationships in dynamic layering. h min >(1+α s )h ideal (2) h max <α c h ideal (3) 876

where, h min is the minimum cell height of cell layer, h max is the maximum cell height, h ideal is an ideal cell height, α s is the layer split factor, and α c is the layer collapse factor. [14]. Experimental equipment and methods Figure-5 shows the measuring device of the cooling capacity of the cooling cycle used in these experiments. The test conditions are shown in Table-2. The stroke and frequency of the linear compressor were controlled by the power supply, and an oscilloscope and a powermeter are used to measure the location of the stroke and the phase between the current and the back electromagnetic force. The experiments were carried by LG Electronics [15]. RESULTS AND DISCUSSIONS Variations of flow velocity with piston displacement Figure-6 shows the velocity distribution of model-1 and model-2 when the piston angle in the second cycle is 118. Right after the suction valve has been closed, the internal Table-2. Test conditions for the refrigeration cycle. Property Stroke Frequency Suction temperature (T1) Condenser pressure (P2) Evaporator pressure (P4) Value 12.4 mm 56.5 Hz 25.0 o C 416,030 Pa 48,550 Pa pressure of the piston becomes higher than the inlet pressure by the flow inertia. Due to this pressure difference, the reverse flows of the maximum 8.5 m/s occurs in the case of Model-1 and also the reverse flows of the maximum 19.4 m/s occurs in the case of model-2. This is because model-2 generates larger flow inertia than model-1 due to its multi-stage expansion tubes and a muffler. When the piston angle in the second cycle is 270, the velocity distribution of model-1 and model-2 are shown in Figure-7. In the case of model 1, the maximum velocity of 50 m/s occurs at the Venturi tube of the inlet pipe and in the case of model-2, the maximum velocity of about 60 m /s occurs at the third expansion tube from the inlet. This also results from the fact that model-2 has higher pressure difference between the piston and the inlet in comparison with model-1. On the other hand, the convergence problem might occur since the flow velocity into the cylinder right after the opening of the suction valve is too high. This is because the movement of the suction valve was simplified so that the suction valve can be instantaneously fully open or closed. Therefore, in order to improve the convergence, the simulation was temporarily performed for 500 time steps with time step of 10-6 s. (a) Model-1 (b) Model-2 Figure-6. Velocity vectors for model-1 and model-2 at piston angle of 118. (a) Model-1 (b) Model-2 Figure-7. Velocity vectors for model-1 and model-2 at piston angle of 270. Variations of pressure with piston displacement Figure-8 shows the variation of the cylinder pressure with the piston displacement for the second cycle. Model-1 indicates a higher pressure of up to 18.1% as compared to model-2 in compression process 1 2 as well as a higher pressure of up to 3.0% in expansion and suction process 4 1. This suggests that more refrigerant enters the cylinder in the case of model-1 since both models have same cylinder volume. This also serves to further increase the maximum pressure during the next compression process. Figure-9 shows the variation of the pressure on the piston side surface of the suction valve with the piston angle for the second cycle. Model-2 shows relatively low pressure in comparison with model-1, except for the range from 54 to 180. It is because model-2 generates larger flow resistance in comparison with model-1 due to the muffler and the multi-stage pipes inside the piston of model-2. 877

Normalized pressure [%] 800 700 600 500 400 300 200 100 0-100 -2 0 2 4 6 8 10 12 14 Displacement [mm] Model 1 Model 2 Figure-8. Variations of normalized cylinder pressure with piston displacement. Normalized pressure [%] 4 2 0 2 4 6 8 10 BDC TDC BDC Model 1 Model 2 0 30 60 90 120 150 180 210 240 270 300 330 360 Angle[degree] Figure-9. Variations of normalized pressure at the pistonside surface of the suction valve with piston angle. After the suction valve opens, the pressure in model-2 drops about 3% more than model-1 at the piston angle of 324, which causes greater pressure rise for the next compression process. Variations of mass flow rate with piston displacement Figure-10 shows the variation of the normalized mass flow rate at the compressor inlet with the piston angle. The mass flow rate is normalized by the cycleaverage mass flow rate. The reverse flows are observed at the inlet during the compression process regardless of the model. The reverse flows occur between about 72.4 and 132.8 and the maximum normalized mass flow is 134% for model-1. For model-2, the reverse flows occur between about 78.5 and 199.9 and the maximum normalized mass flow is 199%. This suggests that the high pressure caused by the flow inertia prevents the inflow of refrigerant from the outlet of the evaporator. Also, it can be seen that the variation of mass flow rate by the flow inertia corresponds to that of pressure by the flow inertia. Figure-10 shows the variation of the normalized mass flow rate of the suction valve with the angle of the piston for the second cycle. Although the difference of the mass flow rates between both models is very little, it can be seen that model-1 has higher refrigerant intake of about 2.4% in comparison with model-2. This is because model- 1 has lower flow resistance than model-2. In particular, the difference of the mass flow rate between both models Normalized mass flow rate [%] BDC TDC BDC 250 200 150 100 50 0-50 -100-150 -200 model 1 model 2-250 0 30 60 90 120 150 180 210 240 270 300 330 360 Angle [degree] Figure-10. Variations of normalized mass flow rate at compressor inlet with piston angle. Table-3. Comparison of normalized cooling capacity. Model-1 Model-2 Difference between Model-1 and model-2 Experiment 100.0% 98.5% -1.6% Numerical analysis 120.7% 117.8% -2.4% Difference between Exp. and Num. 20.7% 19.4% 0.8% becomes prominent in the piston angle range of 240 to 300, where the piston speed is the fastest. Model-1 shows a higher mass flow rate of 20 % than model-2 at the piston angle of about 251. Variations of compressor cooling capacity with the models The variations of the cooling capacity of the compressor with the models are shown in Table-3. The cooling capacity was normalized by the measured cooling 878

capacity of model-1. First, the numerical cooling capacity is compared with the experimental value. For model-1, the numerical value is greater by 20.7% than the experimental value and by 19.4% for model-2. So the difference between both values is comparatively large. It is suggested that this difference results from the simplification of the valve behavior in the numerical analysis. Therefore, in order to predict the accurate cooling capacity, the accurate modeling for the behavior of the suction valve or the discharge valve is necessary, which requires FSI (Fluid- Structure Interaction) analysis. Next, the comparison of the cooling capacity between the models is performed. By the experimental results, the cooling capacity of model-1 is greater by 1.6% than that of model-2. By the numerical simulations, the cooling capacity of model-1 is greater by 2.4% than that of model-1. Therefore, the numerical analysis shows a good agreement with the experiment. In conclusion, the numerical analysis model developed in this study can be successfully used for shape optimization of the linear compressor. CONCLUSIONS In this study, the 3-dimensional CFD model for the linear compressor was developed and verified through the experiments. Furthermore, the variations of flow velocity, pressure, mass flow rate and cooling capacity with the compressor models were examined. The conclusions obtained through this study are as follows: a) By the numerical analysis, the internal pressure of the piston during the compression process is about 2% higher for model-2 than model-1, and the internal pressure during the expansion process is about 3% lower for model-2 than model-1. This is because model-2 has the muffler and the multi-stage expansion tubes in the piston that cause a greater pressure loss. b) Model-2 shows not only 20% lower maximum mass flow rate but also 2 % smaller total mass flow compared to model-1. This is again due to the additional pressure drop by the muffler and the multistage expansion tubes. c) The numerical predictions of cooling capacity are relatively large compared with the experimental values due to the simplification of the valve behavior. However, the numerical predictions for relative comparison of cooling capacity with compressor shape are in good agreement with the experimental results. Therefore, the numerical model developed in this study can be successfully used for optimizing the shape of the compressor for better performance. In the future, a FSI analysis considering the behavior of the valve will be performed to improve the prediction accuracy of the cooling capacity for a linear compressor. ACKNOWLEDGEMENTS This research was supported by Basic Science Research Program through the National Research Foundation of Korea(NRF) funded by the Ministry of Education, Science and Technology (2011-0024805). In addition, this work was supported by the Human Resources Development program(no. 20134030200230) of the Korea Institute of Energy Technology Evaluation and Planning(KETEP) grant funded by the Korea government Ministry of Trade, Industry and Energy. Nomenclature h: Enthalpy [kj/kg] or height [m] k: Turbulence energy [J/kg] m: Mass flow rate [kg/s] P: Pressure [Pa] Q CC : Cooling capacity [W] S h : Volumetric heat source [W/m 3 ] t: Time [s] T: Temperature [K] Α: Layering facor ε: Turbulence dissipation rate [J/kg s] Subscripts avg: Average c: Collapse cc: Cooling capacity s: Split REFERENCES [1] H. K. Lee, G. Y. Song, J. S. Park, E. P. Hong and W. H. Jung. 2000. Development of the Linear Compressor for a Household Refrigerator. Proceedings International Compressor Engineering Conference, Purdue University. pp. 31-38. [2] H. Lee, S. H. Ki, S. S. Jung and W. H. Rhee. 2008. The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor. Proceedings International Compressor Engineering Conference, Purdue University. [3] J. K. Kim, C. K. Roh, H. Kim and J. H. Jeong. 2011. An Experimental and Numerical Study on an Inherent Capacity Modulated Linear Compressor for Home Refrigerators. International Journal of Refrigeration. 34: 1415-1423. [4] J. K. Kim and J. H. Jeong. 2013. Performance Characteristics of a Capacity-Modulated Linear Compressor for Home Refrigerators. International Journal of Refrigeration. 36: 776-785. [5] H. Kim, C. K. Roh and J. K. Kim. 2009. An Experimental and Numerical Study on Dynamic Characteristic of Linear Compressor in Refrigeration 879

System. International Journal of Refrigeration. 31: 1536-1543. [6] C. R. Bradshaw, E. A. Groll and S. V. Garimella. 2011. A Comprehensive Model of a Miniature-Scale Linear Compressor for Electronics Cooling. International Journal of Refrigeration. 34: 63-73. [7] N. Chen, Y. J. Tang, Y. N. Wu, X. Chen and L. Xu. 2007. Study on Static and Dynamic Characteristics of Moving Magnet Linear Compressors. Cryogenics. 47: 457-467. [8] N. C. Tsai and C. W. Chiang. 2010. Design and Analysis of Magnetically-Drive Actuator Applied for Linear Compressor. Mechatronics. 20: 596-603. [9] Y. P. Yang and B. J. Huang. 1998. Fuzzy Control on the Phase and Stroke of a Linear Compressor of a Split-Stirling Cryocooler. Cryogenics. 38: 231-238. [10] 2013. Ansys Fluent V14, Ansys Inc. [11] J. K. Kim and J. H. Jeong. 2013. Performance Characteristics of a Capacity-Modulated Linear Compressor for Home Refrigerators. International Journal of Refrigeration. 36: 776-785. [12] B. E. Launder and D. B. Spalding. 1974. The Numerical Computation of Turbulent Flows. Computer Methods in Applied Mechanics and Engineering. 3: 269-289. [13] 2013. Thermodynamic and Transport Properties of Refrigerants and Refrigerant Mixtures Database V7.0, National Institute of Standards and Technology. [14] Ansys. 2013. ANSYS FLUEN User's Manual Version 14.0, ANSYS Inc. [15] LG electronics Inc., http://www.lge.co.kr. 880