SMTmax Corp. AE-3090D Automatic Stencil printer. User Manual

Similar documents
icreasepro Creaser Operators Manual

O P E R ATING INSTRUCTIONS FOR MODEL SPR-45 Automatic Screen and Stencil Printer

Model 130M Pneumatic Controller

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

A Development of Mechanical Arm for Weight Scale Calibration

Version 1.0. icrease pro + Serial Number. Date

200 PSI COMPRESSORS - MODEL NUMBERS

100C Air Compressor Kit

444C DUAL PERFORMANCE VALUE PACK

400C & 450C DUAL PERFORMANCE VALUE PACKS

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL

IMPORTANT SAFETY INSTRUCTIONS

MAINTANCE MANUAL CNC ROTARY TABLE MODEL: DMNC-5C YUASA INTERNATIONAL.

MoveRoll Conveyor Operating and Maintenance Manual

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

MASTEEL FABRICATION EQUIPMENT

ACV-10 Automatic Control Valve

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

A4s Operation Manual

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

When your Rock-N-Bowl was shipped from the factory, the dipswitches were set as follows:

CRYOGENIC TANK SERVICES - CHART RECORDER MANUAL

! WARNING! IMPORTANT HPA AIR TANK SAFETY INSTRUCTION AND GUIDELINES ! WARNING! IMPORTANT SAFETY INSTRUCTION AND GUIDELINES

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Cover.qxd 1/10/05 10:30 AM Page 2. user manual. diablopaintball.com

Operating Instructions Part No

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

Roller AC Servo System

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

Product instruction manual Easymount Sign Laminators EM-S1400C, EM-S1600C, EM-S1400H, EM-S1600H

CCT-7320/ROC-2313 Reverse Osmosis Controller

IMPORTANT SAFETY INSTRUCTIONS

OC Panel High Limit Aquastat Kit, Manual Reset p/n

KEG PUMP. Range of Electric Keg Pumps

AHE58/59 AC Servo System

POWER ASSISTED BICYCLES OWNERS MANUAL

YSC-8330 USER MANUAL XI AN TYPICAL INDUSTRIES CO.,LTD.

Road Force Elite The World s Fastest Diagnostic Balancer

GV Standard X-Vent. Setup, Commissioning & Installation Guide

J12 TICKET DISPENSER HOPPER ALL STOP STOP 1 STOP 2 STOP 3 BIG DOUBLE SMALL TAKE PLAY START CURRENT PRODUCTION BOARD TYPE

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

In Vivo Scientific, LLC INSTRUCTION MANUAL

User Manual GRI- 1500Li

Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions)

Operators & Maintenance Manual OPERATOR S MANUAL USAGE AND MAINTENANCE F100M F100M. Powered Fixed Hoist Ideal for raised swimming pools and hot tubs

The Crease Matic 150 is quiet in operation and the drive motor shuts down if not used for a period of time.

HumiSys HF High Flow RH Generator

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

200 PSI FAST-FILL AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT

TECHNICAL DATA. Q = C v P S

IMPORTANT CO2/ HPA AIR TANK SAFETY INSTRUCTION AND GUIDELINES. Tank valves must be installed or removed by qualified personnel.

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

IMPORTANT CO2/ HPA AIR TANK SAFETY INSTRUCTION AND GUIDELINES. Tank valves must be installed or removed by qualified personnel.

Smart performance with innovative and ever-strong coil drive even under harsh working environments

TECHNICAL DATA. Q = C v P S

Flamco Flamco-Fill STA Flamco-Fill STM

Controller for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW User guide

AutoDrill s OUTSTANDING FEATURES

Road Force Elite. The world's fastest diagnostic balancer NEW

SSI Solaris 150 RTA Revision /27/2016 Page 1 of 9. SSI Solaris 150 RTA

TECHNICAL DATA. Q = C v P S

AUTOMATIC GAS MANIFOLDS

Squeegee Unit for MRS Multi-Recovery System

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

BUBBLER CONTROL SYSTEM

Safety, Operating and Maintenance Manual. TRAIN Rat DS9-TRAIN

Index Table. Model 794. Installation, Operating and Maintenance Instructions

OPERATION AND INSTALLATION MANUAL

WARNING OLED & BASIC MENU QUICK START

Chair Topper. Autoadapt. Hoisting and stowing. User manual

User Manual for the Mars Calibration Bench

PTC INSTRUMENTS 2301 Federal Ave Los Angeles CA Phone: Model 500 Automatic Operating Stand Type 3

480C DUAL PERFORMANCE VALUE PACK

MAGNETIC MINI EXERCISE BIKE SF-B0418 USER MANUAL

CO 2 and O 2 scrubbers

Laboratory Mortar Mixer (Testing)

Operating manual UCT - Universal cutting tool

INSTALLATION PROCEDURE 1/4 & 1/8 MILE PERMANENT TRACK

UsER manual for Watersens ph -REDOX

Maintenance Manual. Note: This document is broken up into the following 6 sections of prescribed maintenance.

Operating Instructions Part No

Contents MAX CLIMBER 1000 RACK & PINION HOIST 1

VR1 Owner s Manual. Vigilance Rifles, Inc Plum Lane Redlands, CA P F

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Dosing & Granudos. Controllers. Chemical Storage. Chemical. Dosing &

E Cube Lift Model: ECU Installation Instructions

INSTRUCTION MANUAL. Thanks for purchasing our airbrush compressor and please read this

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

PRC CO ² -LASER PRESENTATION

A. TO PREPARE THE MACHINE FOR USE.

Budget Range Operators Handbook

Description. Measuring Device 3760XBI USP. Balancing

Glove Box Installation Manual

Transcription:

SMTmax Corp. AE-3090D Automatic Stencil printer User Manual SMTmax Corporation 5675 Kimball CT, Chino California 91710 www.smtmax.com

AE-3090D Index 1. Introduction 2. Specifications 3. Installation guide lines 4. Setting up parameters 5. Programming Semi or Auto modes. 6. Spare Parts 7. Maintenance 8. Wiring diagram.

Introductions Automatic alignment and printing Precision linear guide way with bottom raising PCB supporter will lift up using mechanical system that automatically aligns the PCB to the stencil for each print without operator intervention simply insert PCB into conveyor rails. Board precision mechanical alignment mechanism eliminates alignment errors Mark points erratic, shadows; parallax error or solder residue will not affect accuracy when PCB comes to align up position, eliminating vision system errors from image distortion. Dual stroke control reduces solder paste consumption A dual squeegee/dual stroke control system for the most efficient use of solder paste. AE-3090D cycle time is just 5-10 seconds per PCB with registration repeatability of ±0.1 mm. All movements PCB position, mounting table and squeegee head rely on precision linear guides. Print speed and table up/down speed are controlled. Large print area, PCB bottom support, easy PCB setup AE-3090D comes with two rails conveyor open up to 400mm, PCB size up to 400 x 350 mm. Flexible tooling holders that can be used with tooling pins (included) or vacuum, for edge-to-edge printing, make PCB setup and changeover very quick. Stencil frames can be up to 750 mm. Precision PCB bottom supports designed to move up and down for supporting single or double sided PCBs flat. Easy programming All parameters print speed, stroke length, squeegee pressure, etc. are fully programmable using the graphical, Windows-based control software. During operation, the onscreen process status shows all details of the current print job. Easy to clean stencil screen The printing squeegee holder can lift up 45 in front to make cleaning and handling of the stencil screen and squeegee blades easier. Machine specifications

Working area Printer surface Max. Stencil screen size Min. stencil screen size Precision adjustment Power 350 (W)x450mm (L) 350x450mm 600x750mm 500x370mm 1.forward/backward±10mm 2.Left/Right±10mm 3.Rotation±30 Single Phase 110V/220V 50/60HZ Air pressure 5-7kg/cm 2 speed Machine overall Dimensions Screen frame holder VR set up(squeegee speed set up);frequency loader(left and right moving speed);display 1100mm(L)x900mm(W)x1650mm(H) Air pressure+manual Installation guidelines 1 installation location:location of the machine placed should have enough room reserved as machine maintenance and calibration. 2 Power supply:single phase: 220V,50/60HZ 3 air supply:pressure request 5-7KG/cm 2 4 level:placed on the platen level meter, adjust the four screws feet, and fixed Software Interface

Main user interface window: Set parameters, select auto or semi auto functions. Manual window: Allows you to move each individual function for stencil and PCB set up. Stopper: UP/Down PCB stopping point location. Move: Turns conveyor ON/OFF LF SQG: left squeegee can be moved up or down RT SQG: right squeegee can be moved up or down Zero: everything resets to 0.0 point (starting point before adjustments were made) Up stop: No use. SCRN DWN: moves entire stencil up or down Move LF: moves both squeegees to left side Move RT: moves both squeegees to right side Rail CLP: closes the width of the conveyor Rail OPN: opens the width of the conveyor PCB UP: moves bottom support upwards PCB DWN: moves bottom support downwards System Parameter setup

Click System setup in main window Enter in the factory password of 123 Now you can adjust the available parameters

Run Set Click Run SET on main window and enter factory password 123

Now you can adjust the available RUN parameters Production Parameter setup Click production parameter setup in main window

Now you can set the aviliable paramters: Starting from top to right side: Manual: Allows you to turn on this function in order to start implementing functions Stopper: UP/Down PCB stopping point location. Move: Turns conveyor ON/OFF LF DWN: left squeegee can be moved up or down RT DWN: right squeegee can be moved up or down Move LFT: moves both squeegees to left side Move RT: moves both squeegees to right side PCB UP: moves bottom support upwards PCB DWN: moves bottom support downwards CLP Tight: closes the width of the conveyor CLP Loose: opens the width of the conveyor SCRN DWN: moves entire stencil up or down Reset: everything resets to 0.0 point (factory starting point) SAVE WID: Will save your conveyor width SAVE UP: will save your PCB bottom support Cover on: no application CLP Tight: micro conveyor width adjustor

Semi Automatic Click semi automatic button: Click SEMI ON: To turn option ON or OFF Pressing the ON button on the bottom right side will allow you to start the process one step at a time.

Automatic Screen Click automatic button: Click Auto ON: To turn option ON or OFF Pressing the RUN button on bottom right side will allow you to start the auto process.

Program diagram 1:set up. setup manual Rails tighten Rails open Adjust width of PCB Stoper Input PCB Set PCB position PCB stop Manual stop Stop conveyor while PCB to Stoper PCB UP PCB DOWN Slight tight Micro tighten Rails tighten adjust PCB tighten force. Rail open When rails open, the PCB move smooth, otherwise redo micro adjustment Width save PCB up save POWER

Semi-auto for adjustment of stencil screen and squeegees hight. POWER Turn power on Main screen Clich semi-auto Semi-suto Enter semi-automatic window to calibrate stencil screen, squeegee stroke down pressure. Click semi-auto button, the semi-auto become green. Press start, then press down to the printing position, adjust the stencil screen align up with PCB overlap. Tighten all fixing screws to the stencil screen frame and open clamp air cylinder adjustable screws. Click Next to start squeegees up/down calibration. Then set up limit screws for squeegees down position. When the semi-automatic program works normal, turn the power off. It is ready for automatic program. 3:Automatic production POWER Main window Power on Automatic Window Click automatic button Press Start, the machine should start to production. You still can set PCB number or press START/PAUSE to clean stencil. After clean click START/PAUSE or START to resume production. Change stencil screen,click CLAMPING.

Spare Parts name specs notes PLC HARUTA Touch Screen Proximity switches (left, right) Sensors(up down) OP320-A PSN17-8DN 24V CS1-F 24V Solenoid Valves 4V210-08 24V Up, Down air actuators Clamp air actuator Squeegee air actuator Power switch SC63*150-S SDAS20*30 MD25*50 HF20W-S-24 Motor Frequency Loarder Air valve Fixted speed, 3P 60W 0.25HP AFC-2000

Trouble Shooting Situations 1.Stencil frame not up 2.Stencil frame not down 1.stencilscreen not down 2. squeegees not move 1.stencil screen down, but squeegees not move; 2.squeegeemove to the end, but not stoop and stencilscreennot up. Stencil screen down, but not immediately up. Not power in Frequency loader no power or can t drive motor Solutions check pressure air(should be at 4kg-6kg). up sensor, wire broken; up or down solenoid valve; PLC. stencil settings. up or down air cylinders air adjustment screws 1.up/down solenoid valves IC board, up/down sensors adjust 2.left/right approximated switches adjust 1.check approximated switch on right or left 2.horizental moving motor, frequency loader, belt slippery. 3.software, PLC problems. 5.communication problem. 1.Adjust left up/right up sensors. 2.up sensors loose 1.power plugs 2.wall power and plugs. 3.power switch. 4.fuse. 5.PLC or main board 1.check settings of frequency loader 2.frequency loader bad 3.communication bad Squeegees not move up/down 1.squeegees up/down sensors bad 2.air actuators adjust screws 3.software or PLC wrong

Preventive Maintinence number name methods time 1 Bearings Lubricate bearings 15 days 2 Air cylinders Lubricate moving parts 7 days 3 Sliding shafts Grease 15 days 4 Linear guild ways grease 15 days 5 Mechanical parts Rusting prevent WD-40 7 days 6 Screws Tighten screws 7 days 7 Mechanical parts Inspect broken or missing 15 days 7 Air leaks Inspect leak or broken 15 days 8 Wirings Inspect electrical parts and wirings 15 days 9 Functions Check all functions 7 days 10 Surface dust Dry cloth 1 day 11 Electrical clean Dry air 7 days

Wiring Diagram: For further assistance feel free to contact us at: SMTmax Corporation 5675 Kimball CT Chino California 91710 Phone +1 (909) 393-8700 Email: info@smtmax.com