Acoustic Emission Testing

Similar documents
The Use of Ultrasonic Inspections at Elevated Temperature

Best Practice RBI Technology Process by SVT-PP SIMTECH

DGZfP-Proceedings BB 90-CD Lecture 4 EWGAE 2004

Acoustic Pulse Reflectometry Brings an End to Tube Inspection Sampling By Dr. Noam Amir, Chief Technology Officer, AcousticEye

Selecting Maintenance Tactics Section 4

Survey of Underwater NDT Technologies for Offshore Assets

INSPECTION OF RECOVERY BOILERS

Guided Wave Testing (GWT)

INNOVATIVE ENGINEERING SUPERIOR SERVICES. Robotic Online Storage Tank Floor Inspection Services

INSPECTION & NON-DESTRUCTIVE TESTING

CERTIFICATION PROGRAM FOR ASSESSING THE MECHANICAL INTEGRITY OF PRESSURE VESSEL SYSTEMS

Damage evaluation for Type-ll CNG cylinder by the analysis of AE parameters

APPENDIX 1. PART 10: Leak Detection Inspector, Level 1, 2 and 3 CERTIFICATION SCHEME FOR PERSONNEL. 3 rd Edition, February 2016

CONVECTION SECTION FAILURE ANALYSIS AND FITNESS-FOR-SERVICE ASSESSMENT

APPLICATION OF ACOUSTIC EMISSION DETECTION TECHNOLOGY ON MULTILAYER BINDING HIGH PRESSURE VESSEL

This document is a preview generated by EVS

In-Service Inspection of Ammonia Storage Tanks

Fitness for Service Assessment of Ageing Pressure Vessel Experiencing External Corrosion: A Case Study

Technical Standards and Legislation: Risk Based Inspection. Presenter: Pierre Swart

Acoustic Emission Testing of The Shell 0f Electromagnetic Valve

Nirvana Variable-Speed Drive, Contact-Cooled Rotary Screw Air Compressors

HYDROGEN STANDARDIZATION INTERIM REPORT For

The Criticality of Cooling

Procedure: Pressure equipment safety

3-PIECE BALL VALVE, 3600 PSI/ PN 248, WITH ISO DIRECT MOUNTING PAD 306M SERIES/ PED Category II

Level MEASUREMENT 1/2016

You Just Experienced an Electrical Failure, What Should You Do Next? By Don Genutis Hampton Tedder Technical Services

Reliability engineering is the study of the causes, distribution and prediction of failure.

Notice for Pressure Special Equipment Manufacture Licensing

Employer s Unit of Competence Magnetic particle testing of materials, products and plant

A review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility

EKC International FZE. Safety Instructions For Handling & Inspection Manual For Refillable Seamless Steel Gas Cylinders

DIFFERENT SOLUTIONS TO INSPECT PLATFORM RISERS. By R van Agthoven and H Quakkelsteijn, ApplusRTD, Rotterdam, The Netherlands

KOMPRESSOREN COMPRESSORS KAESER AIR SERVICE Our Services An Overview

CTRL UL101 MORE THAN JUST A LEAK DETECTOR

Advanced Test Equipment Rentals ATEC (2832) OMS 600

Contents. 1. Non Destructive Testing Requirements. 2. Non Destructive Testing Methods Magnetic Particle Examination

STRUCTURAL INTEGRITY EVALUATION OF CNG COMPOSITE CYLINDERS BY ACOUSTIC EMISSION MONITORING

NASA AEROSPACE PRESSURE VESSEL SAFETY STANDARD

Regulated Oil and Gas Companies under National Energy Board Jurisdiction

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

Products for Cryogenic Applications

RULES PUBLICATION NO. 52/P UNDERWATER INSPECTION OF MOBILE OFFSHORE DRILLING UNITS IN LIEU OF DRYDOCKING

PIP PNE00012 Piping Examination and Leak Test Guide

The American Society for Nondestructive Testing

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

A Rationale for Pressure Relief Device(s) Qualification Requirements (LH2)

MANUFACTURING PROCEDURE SPECIFICATION INSPECTION TEST PLAN

BODY OF KNOWLEDGE API-510 PRESSURE VESSEL INSPECTOR CERTIFICATION EXAMINATION

Pulsed Eddy Current (PEC) Inspection through Insulation

API-510 PRESSURE VESSEL INSPECTOR

Wire ropes condition monitoring: conception and embodiment

USER MANUAL. 1. Principle of operation. 2. Delivery condition. SPRING-LOADED SAFETY VALVES zarmak. Edition: 07/2016 Date: V (ex.

Non-intrusive Natural Gas Flow Measurement

NON-DESTRUCTIVE INSPECTION OF STEEL WIRE ROPES

STANDARD SPECIFICATION FOR SPLIT TEES (HOT TAP MATERIAL)

Instrumentation & Data Acquisition Systems

Enbridge Pipelines Inc. PIPELINE INTEGRITY AXIAL CRACK THREAT ASSESSMENT

Every things under control High-Integrity Pressure Protection System (HIPPS)

Non Intrusive Inspection for process pressure vessels by Advanced and Common NDT techniques save cost whilst enhance safety and reliability

Check Valve Diagnosis by Sectorial Scanning Phased Array Ultrasonic Technique

A hose layline contains important information for specifying the replacement assembly: manufacturer, hose trade name, working pressure and hose ID.

Event Time Event Name Meeting Room Sunday, January Monday, January

Best Practices for Ultrasonic Compressed Air Leak Detection

UKOPA Dent Management Strategy

MSC Guidelines for Pressure Vessels

ASSE International Product (Seal) Listing Program

EVT * -Pro Electronic Valve Tester

E PGN-11. Part of NTW (O)32 Estates Operations and Maintenance Policy Paul McCabe Head of Estates and Facilities-NTW Solution Ltd

Use of Underwater Dry Welding for In Situ Repair to Offshore Structures. Sabine Powell 02/12/2016

2 FUSION FITTINGS FOR USE WITH POLYETHYLENE PRESSURE PIPES DESIGN FOR DYNAMIC STRESSES

Outline for Safety Performance Supervisory Inspection of Boiler and Pressure Vessel Products

FUNDAMENTALS OF PRESSURE RELIEF VALVES IN NATURAL GAS INSTALLATION - OPERATION - MAINTENANCE. Gary S. Beckett

LNG TANDEM OFFLOADING A KEY ENABLING TECHNOLOGY TO MAKE LNG PRODUCTION OFFSHORE HAPPEN

ARISE GLOBAL PTE LTD ADVANCED NDT & INSPECTION SERVICES

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Cold-acclimatised pipelines

NATURAL GAS MAINTENANCE. Part 192 Subpart "M"

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

OCTOBER 2017 ISSUE Page 1 of 7

SF 6 Product Guide. Gas Analysis Instruments and Accessories

Online DGA-monitoring of power transformers

INHERENTLY SAFER DESIGN CASE STUDY OF RAPID BLOW DOWN ON OFFSHORE PLATFORM

TIGHTNESS. Glass sealing Thanks to our glass-sealing technology, ODU products can meet the most demanding tightness requirements.

" High Voltage Switch Yards & How Safe are these really" <Peter Rhodes> <Principal and High Voltage Solution. Com Ltd>

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

W E NE E D TO TA LK A BOUT COLD FLOW. The Problem With The Cold Flow Standard.

Applied Compression s nitrogen generator packages offer users a cost-effective alternative to costly bottled nitrogen.

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

Essa Certified Pressure Filters

PRESSURE RETEST. 49 CFR, (g) Co#: Vin#: DOT Spec: MAWP:

Ultrasonic Inspection of In-Service Composite Bicycles and Components

Acoustic signals for fuel tank leak detection

CURI Pierside Stainless Diesel Tank

DOWNLOAD OR READ : HIGH PRESSURE LIQUID OXYGEN KEROSENE ENGINE COMBUSTION PDF EBOOK EPUB MOBI

Identification and Screening of Scenarios for LOPA. Ken First Dow Chemical Company Midland, MI

Challenges in Relief Design for Pilot Plants

MITIGATING PIPE AND RISER HYDRAULIC PIPELINE ISSUES WITH THE I-RISER PLUS

PRESSURE SYSTEMS POLICY

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Transcription:

Acoustic Emission Testing ATTAR Advanced Technology Testing and Research Manage Your Assets Determine plant and equipment condition with minimal disruption, enhanced sensitivity and significantly reduced costs

Acoustic Emission Monitoring Operators face constant pressure to maximise productivity while keeping costs down. Maximising asset utilisation and minimising expensive inspections is one way to keep costs under control. Technologies that monitor assets effectively while avoiding major shutdowns have become essential tools for operators. Advanced technologies such as Acoustic Emission Testing (AET) enable you not only to diagnose issues, but assess inherent risk - and optimise asset maintenance & capital expenditure through proactive management strategies. Effective & Reliable Inspections Cost Containment Technology that addresses safety, regulatory & environmental concerns Asset structural integrity and corrosion monitoring Acoustic emission is a cost-effective and sensitive method for assessing the condition of pressurised systems and load-bearing structures. Defects are detected and located using a targeted array of sensors applied to a structure under stress. These sensors listen for high frequency signals ('noise') generated by active defects e.g. cracking, corrosion, and leakage. Structural integrity is evaluated in one test, with relatively little process interruption. If AET results are within acceptable levels, the vessel can then be placed back into service; otherwise, complementary NDT methods can be targeted to suspect areas. Assets are ranked in terms of damage and prioritised for maintenance - saving time and money. Acoustic emission testing is unique to all other non-destructive testing methods in that it detects defect growth as it is occurring. It is of great importance to have such a non-destructive test method that can detect and locate discontinuities as early as possible: repair or replacement can take place long before a catastrophe occurs, preventing loss of life, environmental damage, loss of production and more costly repairs.

Reasons to Use AE Minimal cost Cost is a fraction of the price of an internal NDT inspection No significant cleaning costs or environmental waste disposal; no need to empty tanks, pressure vessels, etc. Little disruption to plant operation/minimal downtime Global inspection of the entire structure Defects are located and can be characterised Monitoring of in-service defects under differing operating conditions or changes over time Results Early and rapid detection of a wide variety of defects e.g. corrosion, fracture, delaminations, disbondment, deformations Results used to identify and prioritise maintenance according to risk High sensitivity Method accepted in Europe, Canada, US, South America, Middle East & Australasia Defect location Reveals strength, damage and failure Permanent, digital recording Ease of Inspection Global inspection that does not require access to the whole examination area Sensors can be directly mounted on test specimens, or placed at distanced locations Minimal pre-inspection preparation, disturbance of insulation or disruption of the asset On-site or remote monitoring; potential for online inspection Inspections of difficult-to-access areas and Corrosion Under Insulation (CUI) May be used in accordance with high temperature processes as well as cryogenic vessels Turnaround time AET can take a matter of hours Typical Applications Tanks (atmospheric or pressurised storage, spherical, Fibreglass Reinforced Plastic (FRP) Pressure vessels (ambient, hot or cryogenic, metallic and FRP, spheres) Compressed-Gas Cylinders & Tube trailers (fixed or portable installation) Pipeline & high energy piping testing For more applications and additional information, refer to page 11

Acoustic Emission Monitoring: How it Works Acoustic emission is an elastic wave which results from a sudden release of energy within a material; these waves are generated by dislocation motions associated with materials under stress. Acoustic Emission Testing (AET) is based on the detection and conversion of these high frequency elastic waves to electrical signals. Sensors are coupled to the surface of the structure under test; they listen for signals ('noise') generated by active defects, corrosion processes, leaks, creep in steam lines, or strand failure in cable bundles. Acoustic Emission (AE) Sources: Active cracks Plastic deformation of material Active corrosion and spalling of corrosion products Leak noise AET records energy emitted by a structure while it is being subjected to stress through either controlled stimulation of the structure, or on-line monitoring during normal operation. ATTAR s ASNT SNT-TC-1A Level II and III AE technicians and engineers interpret the signals to classify the condition of the structure. The signal generated by a sensor has many features commonly used to characterise it: amplitude, duration, rise time, decay time and AE counts. The sensitivity of AE sensors allows a single sensor to potentially monitor a large area. As typically full arrays of sensors are used, the system is provided with the versatility to test many types of structures, such as tanks, pressure vessels, gas cylinders, pipelines, bridges, jet airplanes... Structural integrity is evaluated in one test, with relatively little process interruption. If AE results are within acceptable levels, the vessel can then be placed back into service; otherwise, complementary NDT methods can be targeted to suspect areas. Assets are ranked in terms of damage and prioritised for maintenance - saving time and money. Analysis & Reporting Test results are analysed for any potential anomalies. ATTAR reports include a diagram of the subject indicating severity and location of acoustic emission activity, as well as an assessment or classification of the structure. Caption: Left: A class C tank floor plan view showing acoustic emission activity. AET indicates a medium level of activity on the tank floor that would indicate no immediate need for an internal inspection but should be retested in one year. Right: A 3D view of the tank floor indicating the level and location of acoustic emission activity.

Credibility Acoustic Emission Testing Standards - Australian and International AE monitoring is recognised globally through various networks of Australian and International Standards, Pressure Vessel Codes and ASTM test methods. These include but are not limited to: AS 3788: Pressure Equipment. In-Service Inspections ASTM E1139: Standard Practice for Continuous Monitoring of Acoustic Emission from Metal Pressure Vessels ASME Boiler & Pressure Vessel Code: Article 12 Acoustic Emission Examination of Metallic Vessels During Pressure Testing AS2030 SAA Gas Cylinders Code AS 2337 Gas cylinder test stations - Transportable gas cylinders - Periodic inspection and testing of composite gas cylinders AS 4748 Acoustic Emission Testing of Fibreglass-Insulated Booms on Elevating Work Platforms ASTM E569 Standard Practice for Acoustic Emission Monitoring of Structures During Controlled Stimulation ASTM E1067 Standard Practice for Acoustic Emission Examination of Fiberglass Reinforced Plastic Resin (FRP) Tanks/Vessels ASTM E1211 Standard Practice for Leak Detection and Location Using Surface Mounted Acoustic Emission Sensors ISO/DIS 16148 Refillable Seamless Steel gas Cylinders Acoustic Emission Examination (AEE) for Periodic Inspection DIN EN 14584 Acoustic Emission Examination of Metallic Pressure Equipment during Proof Testing. ASME Boiler & Pressure Vessel Code Article 11 Acoustic Emission Examination of Fiber-Reinforced Plastic Vessels Feasibility: Ensuring the sensitivity and robustness of AE Background noise from weather, structure internals or processes, loading or pressurisation may occur. ATTAR staff has monitored crack growth inside jet trainer aircraft during hundreds of hours of flight, high pressure pipelines in operating power stations, and fibreglass pipelines carrying fluid; we understand the techniques necessary to remove background noise without compromising AE signals of interest. Feasibility testing may be undertaken with real or artificial discontinuities of the type and size expected to demonstrate detectability and reliability, if desired by the client. Acoustic Emission Compared to Other NDT Methods Acoustic Emission Detects growth/movement of flaws Related to stress field generated by flaws Direct relationship to material failure Best suited for global monitoring Each loading is unique Less intrusive; easier access Applicability, technique depends on material Less dependent on local geometry Most Other NDT Methods Detects presence of flaws Relates to size and shape of flaw Indirect relationship to material failure Only suitable for local scanning Inspections are easier to repeat More intrusive; harder access Applicability, technique depends on material More dependent on local geometry Limitations of Acoustic Emission Unstressed flaws will not emit Dependence on stress history Sound wave attenuation Background noise Limitations of Other NDT Methods Close access required Dependence on surface condition, geometry Some methods are limited to surface-breaking flaws Time and money spent removing flaws that may not be active in service

Storage Tanks Acoustic Emission Testing (AET) of above ground storage tanks can add significant value to a risk based inspection. Prescribed in AS 1940 & API 653, AET can be used to justify postponing internal inspections or assist in prioritising tank maintenance planning, saving both time and money. AET is a non-intrusive inspection method that enables the detection of active leaks, corrosion and cracking without the need to empty the tank and, as a consequence, reduces costs while incurring only a minor interruption to operational readiness. Both tank floors and whole tanks can be monitored, including cylindrical, FRP and cryogenic tanks. Benefits of AET include: Justify decisions to: - continue in service use without further internal inspections - open the tank and perform conventional NDT on localised areas (saves cost) Tank Inspection Economics - Cost is a fraction of the price of internal inspections - No additional cleaning, contamination or environmental waste disposal costs/issues Safety benefits: personnel do not need to enter the tank Sensitivity to and localisation of active defects Tanks may be placed back into service immediately following testing Little preparation required from the plant operator Data used for grading tank floor condition and detection of leaks Good Tank Bad Tank

Testing Procedure Sensors are mounted on the outside of the tank with acoustic emissions generated from the tank recorded over a period of a few hours. Preparation required is minimal: the tank should remain static for a short period of time prior to and during testing and after, ideally being filled to better than 70% capacity. Report Leaks, corrosion and crack indications are identified, localised and graded according to their severity. An output of the data can be shown as a map, indicating both the location of acoustic emission active sites and their level of activity. Please note: AET does not determine remaining floor thickness or corrosion rate. The overall condition of the tank floor is graded based on the level of Acoustic Emission activity. There are five tank classifications used by ATTAR, providing clear direction for clients to prioritise asset maintenance. Tanks are classified from A (very good) to E (very bad), clarifying which tanks to open and to perform conventional NDT on localised areas, and which tanks can be placed back into active service with no further internal inspection within a recommended time interval. Tank floors graded level A are characteristic of very low risk tanks which should be retested in five years. Higher risk tank floors are classed as Level E, which have very high acoustic emission activity and would normally initiate an immediate internal inspection.

Pressure Vessels ATTAR s experience in the application of AET on pressure vessels includes gas cylinders, LPG bullets, ammonia tanks, CNG, helium and hydrogen tubes as well as heat exchangers, spheres and other conventional pressure vessels. ATTAR is NATA accredited for AET and is a certified Gas Cylinder Test Station in accordance with AS 2030 and AS 2337. The cost of AE inspection cylinders is less than the price of complete surface UT, hydrotest and internal inspection Based on the level of AE activity, advice is given to facilitate follow up NDT or maintenance if and where necessary. Comparison of Acoustic Emission Monitoring vs. Conventional Hydrostatic Testing Acoustic Emission Monitoring Onsite or remote monitoring No Contamination Cost saving; minimal logistics Locates defects and targets areas where further inspection may be prudent (reduces cost) Vessel can be put back into operation immediately (dependent on risk classification) Hydrostatic Testing Usually offsite Contamination with H2O; must dry out vessel Costly logistics Only shows pass/fail status. Flaws may propagate during testing without detection Vessel out of action longer The cost of AE inspection is less than the price of complete surface UT, hydrotest and internal inspection.

Testing Procedure Acoustic emission sensors are mounted on the outside of the vessel or cylinder with pressure applied in stages, normally to 10% above normal operating pressure. Continuous monitoring at normal operating pressure may also be possible. Sensor Located AE Sensors mounted over vessel ensuring source from any location can be detected and located. Number of sensors determined by the size of the vessel to be tested. Vessel Pressurisation Sequence Report ATTAR reports include a diagram of the subject indicating severity and location of acoustic emission activity. Tests results showing clusters CNG cylinders under test

High Pressure Pipelines Identifying Creep and Other Defects via Acoustic Emission Testing Using state of art equipment, ATTAR can monitor for active defects such as creep and fatigue cracking in high pressure pipelines. Acoustic Emission Testing (AET) is not only more sensitive than conventional NDT methods, but offers significant cost savings. With AET, entire structures/pipe runs can be assessed in one test and can be used to continuously monitor a structure while in service. Although AET is not specific in identifying defect types, it will locate and potentially indicate their significance, enabling more targeted inspections using other NDT methods (e.g. UT / Phased Array / TOFD, if creep is indicated, or Magnetic particle, for surface breaking defects, etc.) Testing Procedure Sensors are mounted on the pipeline either in direct contact or with wave guides for high temperature applications. The only preparation required is that paint and insulation in the areas where sensors are to be placed needs to be removed. Testing is conducted to ASME V Articles 12 and 13 as well as ASTM E569-07; Standard Practice for Acoustic Emission Monitoring of Structures during Controlled Stimulation. Reporting Test results are analysed for any potential anomalies based on acoustic emission location plots. In the report, a diagram of the structure is provided indicating areas of acoustic emission activity. The report details any anomalies so that follow up inspection may be performed in specific locations identified by AET.

More Applications AE testing is a viable risk-based test method for a wide range of applications: Large Scale Structural Monitoring: Using an array of AE sensors to monitor large areas of a structure simultaneously during stimulated loading or in-service loading, AE testing can identify whether there are any active discontinuities which require further attention. Used in the transmission and distribution electricity networks, AE testing of partial discharge within transformers allows early detection of insulation breakdown in oil-filled transformers Creep in steam lines can be an insidious problem with unexpected and consequential failure leading to costly repairs and shut downs. AE testing of steam lines provides information on the existence of creep activity to identify the location of and need for more definitive testing using Phased Array and/or TOFD test methods, then planning a cost effective replacement or repair program AE testing can be used to assist in the commissioning stage of various sections of plant, where the behaviour and response of a section of plant to new stresses is important Elevating Work Platforms (EWPs): AE testing satisfies the requirements for periodic inspection intervals of EWPs and can also be used for integrity inspection following the application of unusually high loads or if damage is experienced. AE testing is used extensively in the aerospace industry to evaluate ageing aircraft, and also in laboratory research and development into materials and structure performance Ship and railroad tank car evaluations Bridges and other structures Advanced materials testing (composites, ceramics) Nuclear components inspections (valves, lift beams, steam lines) Rocket motor testing Production quality control Many more (field and laboratory)

Why Use ATTAR? ATTAR offers complete AE testing services on a wide range of structures Equipment and software is cutting edge ATTAR undertakes research to better understand and validate the monitoring process Services available on National & International basis Experience: ATTAR has been providing Acoustic Emission Testing (AET) since 1986, offering AET as both an alternative and complementary method to conventional NDT. ATTAR s experience in the application of AET includes tanks, gas cylinders, pipelines, bridges, spheres and other conventional pressure vessels, and Elevated Work Platforms (EWPs). Qualifications of ATTAR Personnel: ATTAR staff are qualified to a minimum of ASNT SNT-TC-1A, Level II and III; ATTAR's Technical Director also has a PhD in Acoustic Emission. More often than not, ATTAR personnel carrying out this work are Materials Engineers with a good understanding of in-service defect development, welding and welding defects. Accreditations: ATTAR is NATA accredited for AET and is a certified gas testing station, including AE testing of gas cylinders in accordance with AS 2030 and AS 2337. THE BRITISH INSTITUTE OF NON-DESTRUCTIVE TESTING Certified System TM Australian Institute for Non- destructive Testing NATIONALLY RECOGNISED T RAINING AUTHORISED QUALIFYING BODY AS 2337 Gas Cylinder Test Station Head Office - Australia Unit 1, 64 Bridge Rd, Keysborough VIC 3173 Australia T +61 3 9574 6144 F + 61 3 9574 6133 E info@attar.com.au www.attar.com.au