Fisher and Whisper Disk Diffusers

Similar documents
Fisher DVI Desuperheater Venturi Inline

Fisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves

Fisher DSA Steam-Atomized Desuperheater

Design DSA Steam-Atomized Desuperheater

Fisher Lever-Lock Handlever Actuators for POSI-SEAL A81 Rotary Valves

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

This manual provides necessary requirements for meeting the IEC or IEC functional safety standards.

Fisher L2sj Low Emission Liquid Level Controller

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Safety manual for Fisher GX Control Valve and Actuator

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Sempell High Pressure Forged Check Valves Forged steel, swing check and tilting disc configuration

1305 Series Pressure Reducing Regulators

Types S100K and S102K Pressure Regulators

Fisher 2625 and 2625NS Volume Boosters

Fisher 8532 High-Performance Butterfly Valve

Type EZH Relief or Backpressure Regulator

Fisher 4660 High-Low Pressure Pilot

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

Fisher 4660 High-Low Pressure Pilot

1805 Series Relief Valves

WHEATLEY Series 500 Swing Check Valve

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

Type 4660 High-Low Pressure Pilot

Types 95L and 95H Pressure Regulators

64 Series Pressure Reducing Regulators

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

English. Safety Instructions Form /2007 WARNING. All Products. How to Get Safe-Use Guides. Inspection and Maintenance Schedules

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

Fisher FIELDVUE DVC6200f Digital Valve Controller PST Calibration and Testing using ValveLink Software

1301 Series High-Pressure Regulators

1805 Series Relief Valves

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Temperature Controllers

Type ACE95jr Tank Blanketing Valve

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Types 749B and R130 Changeover Manifolds

Type FEQ Slam-Shut Valve

Float Operated Level Controllers

Atmospheric relief valve type 1100 Installation and maintenance instructions

T208VR Series Tank Blanketing Vacuum Regulator

Installation, Operation and Maintenance Manual for Back Pressure Regulator

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

Type R622 Pressure Reducing Regulator

BUTTERFLY VALVES Series 800

V DFX Series. Direct-Operated Tank Blanketing Regulator Manual D103808X012

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

Types 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

Type CT88 Backpressure Regulator

Y692VB Series Vacuum Breaker

FLANGED TWO-PIECE BALL VALVES

MEGR-1627 Instruction Manual

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

FLANGED TWO-PIECE BALL VALVES

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

FLANGED MULTI-PORT BALL VALVES

Fisher 4194 Differential Pressure Indicating Controllers

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

DelVal Flow Controls Private limited

WHEATLEY Series 822/820 Swing Check Valve

V DGX Series. Direct-Operated Regulators Manual D103834X012

INSTALLATION, OPERATION & MAINTENANCE MANUAL

RAIMONDI. 3-way globe valve for feedwater heater outlet bypass Installation and Maintenance Instructions

RB Series Regulating System

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

Type 299 Pressure Reducing Regulators

Engineering Data Sheet

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

Types S100C and S102C Pressure

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

Manual Actuated Boiler Blowdown Valves

SLAM-SHUT VALVE. Type OSE CONTENTS INTRODUCTION CHARACTERISTICS. Scope of Manual. Material. Product Description. Connections

INSTRUCTION MANUAL. Anchor Darling 800 Globe Valves. Installation Operation Maintenance. Sizes 1/2 through 2 FCD ADENIM

SIL Safety Manual for Fisherr ED, ES, ET, EZ, HP, or HPA Valves with 657 / 667 Actuator

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

Type Cronos Pressure Reducing Regulator

Masoneilan* Series Self Operating Pressure Regulators

Type 1190 Low-Pressure Gas Blanketing Regulator

VALVES & MEASUREMENT

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

MEGR-1912 Instruction Manual

Installation & Operation Manual Proven Quality since 1892

Installation Instructions For Flat Seated Bolted Type RAH Series Disk Holders

Operating instruction

850 and 950 Series Pressure/Vacuum Relief Valve (ATEX Approved)

RESIDENTIAL REGULATORS

MUELLER. Xp, & Lineseal 350 Butterfly Valves

COMMITTEE DRAFT. API 520 Part I 10 th Edition Ballot Item 2.1. This ballot covers the following item:

FLOW CONDITIONER «EMIS-VEKTA 1200» EMIS-VEKTA 1200.UM.PS v User manual Passport. «EMIS», CJSC Russia, Chelyabinsk

S300 Series. Valve Link. Features. Fisher Controls

Bermad Model:

Transcription:

Instruction Manual Inline and Vent Diffusers Fisher 6010 -- 6015 and Whisper Disk Diffusers Contents Introduction... 2 Scope of Manual... 2 Description... 2 Principle of Operation... 3 Piping Considerations... 3 Installation... 3 Maintenance... 4 Servicing... 4 Troubleshooting... 4 Parts Ordering... 5 Figure 1. Typical Fisher Inline and Vent Diffusers W1162-2 W4888 6010 WHISPER DISK W1155-2 W7353 6011 X0002 6014 WhisperFlo VENT DIFFUSER X0347 6012 www.fisher.com

Inline and Vent Diffusers Instruction Manual Table 1. Specifications (for Standard Designs) Available Configurations 6010: Inline diffuser (with integral outlet head) 6011: Inline diffuser (pipe-style) Whisper Disk: Inline diffuser (flat plate) 6012: Drilled hole Vent diffuser 6013: Drilled hole Vent diffuser (with outer shell) 6014: WhisperFlo disc style 6015: WhisperFlo disc style (with outer shell) Sizes 6010: NPS 1 x 3 to NPS 26 x 48 (inlet x outlet) 6011: NPS 2 to NPS 30 Whisper Disk: NPS 2 to NPS 24 6012: NPS 2 to NPS 26 6013: NPS 2 to NPS 26 (outer shell NPS 4 to 36) 6014: Sizes are available to meet your application (see bulletin 80.3:6014) 6015: With outer shell. Sizes are available to meet your application (see bulletin 80.3:6014) End Connections 6010: Any combination of flanged (raised-face, ring-type joint, and flat-face) or welded end (buttweld or socket weld) 6011: Wafer flanged Whisper Disk: Raised-face or ring-type joint flanged 6012 and 6013: Raised-face flanged, ring-type joint flanged, or buttweld end 6014 and 6015: Raised-face flanged, ring-type joint flanged, or buttweld end Note Inline and vent diffusers are not hydrostatically tested. Introduction Scope of Manual This instruction manual includes operation, installation, and maintenance information for the following diffusers: 6010, 6011, and Whisper Disk Inline Diffusers. See figure 1 6012 and 6013 drilled hole vent diffusers. See figures 2 and 3 6014 and 6015 WhisperFlo disc style vent diffusers. See figures 4 and 5 Do not install, operate, or maintain these diffusers without being fully trained and qualified in valve, actuator, and accessory installation, operation, and maintenance. To avoid personal injury or property damage, it is important to carefully read, understand, and follow all the contents of this manual, including all safety cautions and warnings. If you have any questions about these instructions, contact your Emerson sales office or Local Business Partner before proceeding. Description Inline and vent diffusers are installed to provide backpressure for control valves, which greatly reduces control valve noise generated by steam, gas, or vapor flow applications. Inline diffusers are placed downstream of the valve and are either placed in or between pipe. Vent diffusers are placed downstream of the valve and vent process to the atmosphere. Fisher inline and vent diffusers are used in gas, vapor, and steam applications. 2

Instruction Manual Inline and Vent Diffusers Principle of Operation Inline and vent diffusers are custom designed to match a wide range of valve outlet and/or pipeline size. Furthermore these diffusers are selected to match the application specific conditions including temperature, pressure, and flow capacity. The flexibility of the diffuser types and placement provide a range of installation possibilities. The diffuser is not required to be installed adjacent to the control valve. The 6010 is an inline diffuser that fits between two different sizes of pipe to meet both downstream and upstream pipe sizes with an integral outlet head. The 6011 is a pipe-style inline diffuser that extends into existing pipe using a wafer flange connection. The Whisper Disk is a flat plate-style inline diffuser that is available with a raised-face flanged connection. The 6012, 6013, 6014, and 6015 are vent diffusers that are designed to reduce noise during process venting applications. Piping Considerations Upstream piping should be the same nominal diameter as the diffuser inlet connection and vice versa. The drilled hole pattern of the Whisper Disk inline diffuser must be within the inside diameter of the mating flange schedule. Reducers or elbows are not recommended downstream unless they are at least four to five downstream pipe diameters downstream of the diffuser outlet. Installation Before installation, all piping to the diffuser must be blown clean, so that no particles, such as welding beads, dirt or other foreign matter, are left in the pipeline. Keep foreign matter away from the line openings while preparing the diffuser for installation. CAUTION Cleanliness of the upstream piping is critical. Debris in the piping can damage the diffuser and severely restrict flow, causing overpressure. Inspect the inside of the diffuser and clean if necessary. Arrange a lifting sling around the diffuser to safely place it into the mounting position. Note To avoid flow interaction and reduce noise in 6012, 6013, 6014, and 6015 vent diffuser applications, do not install diffusers in close proximity to support structures and ensure that adjacent diffusers are installed at different heights. 3

Inline and Vent Diffusers Instruction Manual 6013 and 6015 diffusers with shell are provided with mounting brackets for wind and side loads. These mounting brackets also provide support, so the entire weight of the diffuser is not on the inlet connection. The end user shall provide the necessary support structure to interface with the provided mounting brackets on the diffuser. Flanged Connections For high temperature applications, grease the flange connection bolts with a high temperature thread lubricant. Install flange gaskets and connection bolts per accepted practices and tighten securely. Re tighten bolts after the diffuser has been pressurized. Do not expose the diffuser to undue stresses by installing it in bent pipes or bent flanges. Welded Connections Welding procedures should be in accordance with the applicable codes and the base materials. For preheat, welding electrodes, and post weld heat treatment, refer to the standard applicable codes and practices. Materials are specified on the diffuser specification sheet that is delivered together with the diffuser. Maintenance Servicing The diffuser has no serviceable parts. However, during routine maintenance intervals it is important to inspect the diffuser for damaged or cracked welds (exclusive of the Whisper Disk diffuser). Your local Emerson Automation Solutions Instrument and Valve Services office can help determine the correct course of action if damage is present. The diffuser is normally welded or bolted in line and not removed unless it requires cleaning or replacement due to damage or wear. In the event the diffuser is not performing as expected, a bore scope can be used to examine the flow passages for blockages without the need for disassembly and removal. If blockages are present, cleaning can be performed by removing the unit by either cutting of the welds or removal of bolting and using a pressurized water stream to clear any blockages. If blockages are still present after cleaning, the unit will need to be replaced. Troubleshooting Table 2 is intended as a basic first line troubleshooting guide. Contact your Emerson sales office or Local Business Partner for assistance if you are unable to resolve your field operation problem. Table 2. Troubleshooting Guide Problem Anticipated backpressure is not reached. System noise and vibration have suddenly increased above previous levels. Possible Solution Review valve conditions and opening percentage Check for process flow changes and/or Inspect unit. Inspect flow passages in diffuser for blockage, clean if necessary Review operating history to check for process flow changes. Inspect unit. 4

Instruction Manual Inline and Vent Diffusers Parts Ordering There are no serviceable spare parts for this unit. Note Each diffuser is assigned a serial number that can be found on the unit. Refer to the serial number when contacting your Emerson sales office or Local Business Partner for technical assistance. WARNING Use only genuine Fisher replacement parts. Components that are not supplied by Emerson Automation Solutions should not, under any circumstances, be used in any Fisher valve, because they may void your warranty, might adversely affect the performance of the valve, and could cause personal injury and property damage. 5

Inline and Vent Diffusers Instruction Manual Figure 2. Fisher 6012 Vent Diffuser Figure 3. Fisher 6013 Vent Diffuser W8682 1 W8683 1 6

Instruction Manual Inline and Vent Diffusers Figure 4. Fisher 6014 Vent Diffuser Figure 5. Fisher 6015 Vent Diffuser W8799 1 W8798 1 7

Inline and Vent Diffusers Instruction Manual Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fisher and WhisperFlo are marks owned by one of the companies in the Emerson Automation Solutions business division of Emerson Electric Co. Emerson Automation Solutions, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Automation Solutions Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Cernay 68700 France Dubai, United Arab Emirates Singapore 128461 Singapore www.fisher.com 8 2004, 2017 Fisher Controls International LLC. All rights reserved