Submission to the American Optometric Association Contact Lens and. Cornea Section Student Research Awards Committee. for

Similar documents
Critical Oxygen Levels to Avoid Corneol Edema for Daily and Extended Wear Contact Lenses

Sponsored by. Corneal oxygenation

Oxygen tension under a contact lens. Kenneth A. Poise and Marianne Decker

C L I N I C A L A N D E X P E R I M E N T A L OPTOMETRY ORIGINAL PAPER

NOVEMBER Why SiHy? The many benefits of silicone hydrogel make it a preferred material for daily disposable lenses

ARTICLE IN PRESS Contact Lens & Anterior Eye xxx (2012) xxx xxx

Rejuvenating Aftercare for Contact Lens Patients

Table of Contents. Introduction. Content written by: Osuagwu Levi RO, RCLP Content originally published in the Spring 2010 edition of The Eighth Line

POLYMACON HYDROPHILIC CONTACT LENSES PRACTITIONER FITTING GUIDE

AIR OPTIX BRAND CONTACT LENSES LENS PARAMETER GUIDE November 2016

Contact lenses designed to fit more of your patients

An introduction to modern scleral lenses

Rejuvenating Aftercare for Contact Lens Patients

V. Compa~n, 1 M. Aguilella-Arzo, 2 L. F. Del Castillo, 3 S. I. Hernandez, 4 J. M. Gonzalez-Meijome 5

Orthokeratology. What is Orthokeratology? How does it work?

H.ydrophilic soft contact lenses made

NAVAL SUBMARINE MEDICAL RESEARCH LABORATORY

FITTING AND TROUBLESHOOTING SCLERAL LENSES

PACKAGE INSERT RIGID GAS PERMEABLE CONTACT LENSES FOR ORTHOKERATOLOGY. (hexafocon B)

Comparison of oxygen flux in hydrogel and silicone hydrogel contact lenses. By: Jonathan Cohan Eun Ae Cho Megan Connors

DISCLOSURES FITTING AND TROUBLESHOOTING SCLERAL LENSES WHO S A GOOD CANDIDATE SCLERAL LENS ADVANTAGES ANDREW J. BIONDO, OD, FSLS.

Spherical Soft Contact Lens Fitting. J. Perrigin OPTO 6374 Spring 2017

Pardon the Objection (PTO) Contact Lens Clinical Case Debate (2 hours)

The soft approach to RGPs

Acknowledgments. Paragon Vision Sciences Adoption of CRT certification slide for this generic talk. Material Considerations

^- ; asefehs. a»s.^r,--. - "SSSES. v^yj:-- MEDIGÄL. -^j~ ^ z<_^

Gundersen, 1939), however, it seems unlikely that the limbal circulation. Columbia, Missouri 65201, U.S.A. (Received 25 March 1976)

Fitting Guide. Minutes-to-Fit 2.0. by SynergEyes Moving Vision Forward

The BE Retainer System Certification Course. Supplement

PACKAGE INSERT RIGID GAS PERMEABLE CONTACT LENSES FOR CONTACT LENS CORNEAL REFRACTIVE THERAPY

Sofmed breathables XW (comfilcon A) Sofmed breathables XW premium (comfilcon A) Sofmed breathables XW toric (comfilcon A)

PROFESSIONAL FITTING GUIDE. for the. HUBBLE Daily. Table of Contents

Scleral Fitting Guide

PICU Resident Self-Study Tutorial The Basic Physics of Oxygen Transport. I was told that there would be no math!

Section Two Diffusion of gases

Accommodation responses and refractive error

University of Pennsylvania Institutional Review Board. Reliance Agreement Guidance: Post-Approval Submissions

Soft Contact Lens Identification Guide

LASIK Wavefront Guided idesign LASIK with IntraLase

Product Reference Guide Look to the people, products, and services of CooperVision.

Product Reference Guide Look to the people, products, and services of CooperVision.

Calibration Requirements for Direct Reading Confined Space Gas Detectors

The World s Largest Inflatable Water Slide A Public Health Nightmare. Presenters: Megan Savill - EH Team Leader Michelle Speek - Senior EHO


THE OXYGEN PERFORMANCE OF A CONTACT LENS ON THE HUMAN EYE. KRISHNACHAND POSTUM SUBMITTED IN PART FULFILLMENT OF THE REQUIREMENTS FOR THE DEGREE

Unit II Problem 4 Physiology: Diffusion of Gases and Pulmonary Circulation

The Physiologic Basis of DLCO testing. Brian Graham Division of Respirology, Critical Care and Sleep Medicine University of Saskatchewan

Hypothermia, the Diving Reflex, and Survival. Briana Martin. Biology 281 Professor McMillan April 17, XXXX

COST (Dollars in Millions) FY04 FY05 FY06 FY07 FY08 FY09 FY10 FY11 Cost to Complete

Lung Volumes and Capacities

Timber Times. Safety Flyer SPECIAL POINTS OF INTEREST. Partners for Healthy Forests

Biology Paper, CSE Style (Martin)

Respiratory System. Part 2

Management of corneal wounds: some practical tips. Lee SH, MD, FRCS (C ), FAAO

GOVERNMENT OF SASKATCHEWAN SUBMISSION TO THE RAILWAY SAFETY ACT REVIEW PANEL

Retinal vascular response to breathing increased carbon dioxide and oxygen concentrations. Regina Frayser and John B. Hickam

Improvements in the Reliability, Costs and Processing of WLP/RDL Circuits

WVA Contact Lens Code List - Dec 17, :37:50 Page 1

RESPIRATORY GAS EXCHANGE

ITEM 400 STRUCTURAL EXCAVATION AND BACKFILL

Collin County Community College. Lung Physiology

Barrier Development and Evaluation Methodology. D.S. Musgrave 1 1 Thermal Visions, Inc., Granville, USA

J. J. Daly Metal Improvement Company Paramus New Jersey USA

Leadership in Fluid Management

SFT MULTICOAT. Scratches don t stand a chance!

CHAPTER 6. Oxygen Transport. Copyright 2008 Thomson Delmar Learning

IMPROVING QUALITY THROUGH INNOVATION: A FULLY AUTOMATED SOLUBLE SALT METER

Improve Process Reliability

Justification for Rainbow Trout stocking reduction in Lake Taneycomo. Shane Bush Fisheries Management Biologist Missouri Department of Conservation

Oxygen convulsions are believed by many workers to be caused by an accumulation

Hyperbarics and Wound Care: A Perfect Partnership

Levels of CO2 in Arterial Blood of Carp under Carbon Dioxide Anesthesia

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

DRESSED FOR SUCCESS By Stephen Silvester, Technical Services Engineer, ANSYS, Inc., and ANSYS Advantage Staff

Recommended Fish Handling Guidelines for Bass Tournaments in Alabama Waters

They selected fully grown leaves from five different plants of each species.

CDI Blood Parameter Monitoring System 500 A New Tool for the Clinical Perfusionist

Chicken Farmers of Canada ANIMAL CARE PROGRAM UPDATE

Ultrasound Dose Calculations

Satisfaction. For you and your patients.

LAB 06 Organismal Respiration

Hyperbaric Oxygen Therapy

Indications for Mechanical Ventilation. Mechanical Ventilation. Indications for Mechanical Ventilation. Modes. Modes: Volume cycled

1 in 4 patients will contract an HAI during their hospital stay. were prevented, annual cost savings would be $11.3 billion.

White Paper. Overview of MAP Headspace Gas Measurement: Sample Volume Considerations:

Breakthrough Technology. Intrinsically Hydrophilic. EXA lence. Vinyl PolyEther Silicone (VPES ) Impression Material

COST (Dollars in Millions) FY07 FY08 FY09 FY10 FY11 FY12 FY13 Cost to Complete

Homecare Pneumology NEONATOLOGY ANAESTHESIA INTENSIVE CARE VENTILATION Step beyond the future

Eliminating Sources of Error in IV Pump Testing

MyoSure Tissue Removal System. For you and your patients.

2. State the volume of air remaining in the lungs after a normal breathing.

Model XSMKIT. Operations and Instructions WARNING

JetVent SAFE, AUTOMATIC PRESSURIZED CONTAINMENT.

W I L D W E L L C O N T R O L FLUIDS

Becker* Products Below Ground Ball Valve Regulators

Physiological Considerations for Compression Bandaging. Harvey N. Mayrovitz, Ph.D.

Healthy Swimming: Prevention of Recreational Water Illnesses (RWIs)

Dr. Thomas R. Reim President, DreimLens, Inc.

B14 gas exchange note, reading and questions.notebook April 13, 2011

OPESAVER Super Irrigation System

Transcription:

Submission to the American Optometric Association Contact Lens and Cornea Section Student Research Awards Committee for The Evolution of Continuous Wear: How has our knowledge of corneal oxygen requirements, material oxygen transmission, tear exchange behind the lens and ocular pathogens, shaped our thinking about continuous wear contact lenses?

Continuous Wear: The Long and Winding Road John D. Friederich University of Missouri St. Louis College of Optometry

Living in an era with all types of advanced technology, one of the global megatrends is convenience. A growing number of contact lens wearers want to safely sleep in their contact lenses longer. 1 As our understanding of continuous wear and the lenses available have advanced over the years, optometrists have become more able to meet this need without complications. Patient and practitioner interest in extended wear contact lenses was high in the late 1970 s and early 1980 s, and then declined over the next decade, predominantly as a result of many wearers experiencing complications and obtaining infections. 2,3 However, surveys continued to show that consumers were interested in wearing safe extended wear lenses, leading to the development of new lens designs and materials that allow for increased oxygen permeability and tear film movement, with less protein deposits. The relatively recent introduction of highly oxygen-transmissible silicone hydrogel and gas-permeable contact lenses represents a major breakthrough in satisfying corneal requirements for successful continuous wear. However, there are still many questions and challenges that remain regarding complications in continuous wear patients. The Early Years The question of how much oxygen the cornea requires to remain healthy has not been easy to answer. Although it is well-known that oxygen is essential in maintaining corneal health during contact lens wear, there is still much debate on how much oxygen is needed and how to best assess the oxygen needs of lens wearers. The need for contact lenses that transmit high levels of oxygen to the cornea was first recognized almost 60 years ago. 4 The first model of oxygen distribution across the cornea was proposed by Hill and Fatt in 1964; it predicted oxygen flow to the eye during

lens wear using equivalent oxygen percentage. 5-7 This model is based on Fick s Law of diffusion and states that the greater the difference in oxygen tension on either side of a lens, the greater the driving force across the lens, and that the greater the oxygen transmissibility, Dk/t, the more oxygen will flow. 5-7 Attempts to quantify the actual level of oxygen needed by the cornea were not published until the 1970 s. Using gas goggles in 1970, Polse and Mandell found that an atmospheric level of only 1.5% to 2.5% oxygen was needed to prevent corneal swelling. 8 This estimate of the cornea s oxygen requirement is only a tenth of the atmosphere s 20.9% oxygen that an open non-lens wearing eye is exposed to. In the midst of this early research, John DeCarle was working to design contact lenses that were specifically for continuous wear. DeCarle s approach was to develop a lens material with high-water content in order to provide better oxygen permeability. 9 He succeeded in doing so in the early 1970 s and initial reports of continuous wear hydrogels were positive. 10 Later in the 1970 s, however, it was found that even high-water content lenses could produce corneal edema and disruption, 11 and significant corneal complication rates with hydrogel continuous wear were reported. 12 Research done by Mandell and Farrell in 1980 using gas goggles found that between 3.5% and 5.5% equivalent oxygen percentage was necessary to avoid swelling, instead of the previously reported 1.5% to 2.5%. 13 But several other studies raised this estimate and showed that actually between 10 and 15% oxygen is required for the majority of patients to prevent stromal swelling. 14-15 Rise and Fall Nevertheless, the U.S. Food and Drug Administration (FDA) approved DeCarle s Permalens 71% water content hydrogel lens for two weeks of continuous wear in January

1981. 16 The popularity of extended wear lenses grew rapidly in the United States. In 1983, Dow Corning Ophthalmics introduced the first silicone elastomer contact lens, Silsight, for extended wear and it was the first lens given FDA approval for up to 30 days of continuous wear between removals. 16 Soon after that, hydrogel lenses were given approval to go from the previous 14 days of wear to 30 days of continuous wear. The silicone elastomer lenses had exceptional oxygen transmissibility because of the high solubility of oxygen in silicone. They displayed corneal adherence and poor lens movement, however, and were prone to poor wettability, discomfort, and lipid deposits. 16 Since silicone elastomer lenses generally were not well-tolerated by patients, they failed to gain popularity. Hydrogel lenses did, though, and by 1985, about four million people were extended soft lens wearers, and there were more than 20 hydrogel lens products that were FDA approved. Alongside the growing popularity of continuous wear lenses were an increasing number of published articles investigating their impact on corneal health. During openeye lens wear, oxygen may reach the cornea by dissolving in the tear fluid layer between the lens and the cornea or by diffusion through the lens material itself. 17 During hydrogel lens wear, however, most oxygen reaches the cornea by diffusion and not by tear pumping, because hydrogel lenses have little lens movement and poor tear exchange. 18 Furthermore, Benjamin found that circulation of oxygen-rich tears behind a lens only occurs when the eye is open, and therefore, diffusion of oxygen through a contact lens is the major factor impacting oxygen supply during overnight wear. He concluded that oxygen deprivation is of particular concern in the closed-eye state of continuous wear, since the eye must obtain all its oxygen from under the lid without contribution from the

tears. 19 In 1984, Holden and Mertz found that a lens that provides 18% equivalent oxygen percentage during open-eye wear limits overnight corneal edema to 4%, the level experienced when lenses are not worn during sleep. The Holden-Mertz criterion can be achieved with a lens that has an oxygen transmissibility, Dk/T, of 87 x 10-9 (cm x ml oxygen)/(s x ml x mmhg). 20 The high water content hydrogel lenses being used for continuous wear at the time fell well short of meeting this standard. Because the oxygen permeability, Dk, of water (80 barrers) limits the maximum Dk that can be achieved with a conventional hydrogel lens material, even a 100% water content lens can not satisfy the Holden-Mertz criterion for overnight wear. 21 It was becoming apparent that continuous wear corneas were not receiving the oxygen they needed. In the 1985 Gothenburg study, chronic hypoxia from long-term extended wear of the low Dk high-water content hydrogels was reported by Holden and Sweeney to cause reductions in epithelial thickness and oxygen uptake, increased incidence of epithelial microcysts, stromal thinning and chronic edema, and increased endothelial polymegethism. 22 As noted by this study and many others, 23,24 changes induced by chronic hypoxia can be observed in all layers of the cornea in long-term hydrogel continuous wear patients. This seemed to revive interest in developing new contact lens materials with oxygen permeability values that were higher than the 10 to 40 barrers of Dk provided by the existing hydrogel lenses. Soon there after, high Dk rigid gas permeable (RGP) lens materials appeared on the market, with the promise of superior corneal physiology through higher Dk values in the range of 50 to 110 barrers. By 1988, three RGP lens materials had received FDA approval for seven days of extended wear. 16 As a result of their greater lens movement

and tear exchange, RGP lenses were shown to provide a greater amount of open-eye oxygen and less daytime edema and chronic hypoxic stress than hydrogel lenses, and in some reports, superior comfort and vision after the initial adaptation period. 25,26 Lens movement and tear circulation also remove debris and contaminants from behind the lens; the lack of adequate tear circulation can cause the breakdown of trapped contaminants and a subsequent inflammation of the cornea. 12 Despite their physiological and subjective advantages, the poor initial patient comfort 25 and difficulty of fitting compared to hydrogel lenses prevented extended wear gas permeable lenses from gaining much popularity with patients or practitioners. Meanwhile, the reputation of extended wear as a whole was waning. The Fatal Blow In addition to the findings of corneal morphing as a result of extended wear, there were numerous reports that suggested a substantial risk of corneal infection and ulceration among extended wear lens patients. 27,28 Further studies were conducted to better understand the extent and cause of these complications. Particularly, in 1986, the Contact Lens Institute sponsored a study by Schein and Poggio of Harvard Medical School to investigate the relative incidence and causative factors of microbial keratitis. The study, published in 1989, found that the risk of ulcerative keratitis was 10 to 15 times greater with extended soft lens wear than with daily soft lens wear, that the risk increased with each consecutive day of wear before removal, and that proper lens cleaning and disinfection of the lens could reduce the risk. 29,30 Overnight lens use, whether regularly with extended wear lenses or occasionally with daily wear lenses, emerged as the preeminent risk factor for ulcerative keratitis. 29,30 It was also shown that mucoprotein

deposits commonly found on soft lenses serve as a vehicle for the transport of the most common sight-threatening pathogen, Pseudomonas aeruginosa, to the cornea. 31 These findings, particularly the data of Schein and Poggio, 29,30 led to attention from the media and the FDA about the concerns over infections in extended wear. 32 Along with the hypoxic corneal effects of low Dk extended wear soft lenses, the increasing number of articles making media headlines caused extended wear lens use and wear time to decline in the late 1980 s. In May 1989, the FDA mandated a one-week maximum for overnight wear of soft lenses, and changed continuous wear product labels to indicate a recommended wear time of one to seven days, and to stress the importance of proper lens care and the risk of microbial keratitis. Now What? Since patient compliance was considered to be one of the main problems contributing to the occurrence of microbial keratitis, 29 momentum was provided for the expansion of simplified lens care systems, and more notably, the advent of the disposable extended wear hydrogel lens. While the use of blister packaging and 7 to 14 day disposability were new, the lens material itself was, unfortunately, not. Contrary to some people s expectations that regularly replacing hydrogel lenses would make overnight wear more safe, disposable lenses did not minimize the chronic corneal changes that occur during extended wear, 33,34 nor did they decrease the risk of ulcerative keratitis associated with sleeping in lenses. 35 Additional research showed that P. aeruginosa adherence to corneal epithelial cells was enhanced in those who used extended wear low Dk soft contact lenses, 36 perhaps due to the decreased metabolic activity and protective secretions of the hypoxic corneal epithelium. What is more, it was shown that P.

aeruginosa can rapidly create a protective biofilm on contact lenses that have sluggish tear circulation, 37 therefore increasing the number of pathogens on hand to march into the hypoxically compromised cornea. The concern over hypoxic and infectious corneal complications continued to decline the extended wear market, and it was quickly realized that an entirely new lens material and design would be necessary in order for continuous wear to get back on its feet. Back to the Drawing Board Scientists certainly had their work cut out for them, and the industry worked to design a lens that would exceed the necessary oxygen requirements established at that time (Holden and Mertz 20 criterion of Dk/T of at least 87). Though some rigid gas permeable and silicone elastomer lenses did just that, 21 there remained the challenges of improving comfort and maintaining good lens movement. On the other hand, hydrogel materials needed more oxygen permeability and tear circulation. Researchers worked feverishly to develop this ideal lens, experimenting with both wettable silicone-based materials and higher-strength hydrogel materials. 38 They were not able to attain the material they needed until the development of silicone hydrogels. The Rebirth of Continuous Wear For over a decade, patients and practitioners were limited to seven days of extended wear; this ended with the arrival of silicone hydrogels. Silicone hydrogel was and still is a ground-breaking lens material that combines the high Dk levels of silicone with the fluid diffusion characteristics of hydrogel lens materials that facilitate lens movement. The Dk of silicone hydrogels is controlled by the level of silicone incorporated into the base material and they provide an oxygen transmissibility, Dk/T, of

at least 86 to 175 (cm x ml oxygen)/(s x ml x mmhg), while also giving initial comfort and adequate lens movement. One weakness of the new generation of silicone hydrogels is that they are hydrophobic and require a surface treatment or an internal wetting agent to be more hydrophilic and biocompatible. In 1999, CIBA s Focus Night and Day (lotrafilcon A material) and Bausch and Lomb s Purevision (balafilcon A material) were brought to the market. With respective oxygen transmissibility values of 175 Dk/T and 110 Dk/T at -3.00D, both received FDA approval for up to 30 nights of continuous wear in 2001. 16 No hypoxia-related effects were observed with these lenses, 39 and overnight edema levels were similar to the levels seen with no lens wear. 40 The high oxygen transmissibility of these stiffer, lower water content silicone hydrogels had eliminated the physiological corneal changes from hypoxia seen with hydrogel lenses, while providing similar comfort and fitting performance. In 2002, the FDA approved the gas permeable Menicon Z material for up to 30 days of continuous wear, the first time ever for a GP. 16 This 163 Dk material provides better tear flow than silicone hydrogels, and has great potential for safe continuous wear. In 2004, CIBA Vision s O 2 Optix (lotrafilcon B) and Vistakon s Acuvue Advance (galyfilcon A) lenses were introduced to provide more options to practitioners wishing to fit silicone hydrogels, particularly on daily wear patients. Claiming to have better wettability, Vistakon s Acuvue Oasys (senofilcon A) was introduced in 2005. There are also toric, multifocal and custom silicone hydrogel designs that are now available. With sales and the number of wearers increasing considerably each year, silicone hydrogels have captured a substantial portion of the soft lens market and are expected to continue doing so.

Not so Fast High Dk silicone hydrogel lenses have overcome many of the hypoxic problems associated with traditional continuous wear and the popularity of continuous wear with these lens types is increasing. However, there are still many questions that remain to be answered with regards to corneal oxygen requirements, material oxygen transmissibility, and ocular pathogens. Holden and Mertz established the foundations for the new generation of silicone hydrogel contact lenses for daily and extended wear in 1984. It now appears, however, that the Holden and Mertz criteria for extended wear critical Dk/t should be revised upwards to at least 125, or even higher. 41,42 More than this, it has recently been suggested that there are many flaws in using Dk/T as a measurement for high Dk materials. The problem is that Dk/T loses its linear relationship to the amount of oxygen reaching the eye when lens Dk/T levels are 40 or above. Dk/T displays this limited ability to measure lens performance because it does not account for oxygen concentration at the interface of the contact lens and cornea. Despite vast increases in Dk/T, after a certain point there is little change in the actual quantity of oxygen reaching the cornea. 43,44 Increasing the Dk and amount of silicone in a lens also increases modulus and stiffness, resulting in less comfort and increased complications secondary to mechanical trauma during continuous wear, like superior epithelial arcuate lesions (SEALs) and giant papillary conjunctivitis (GPC). 45 Though the incidence of loss of visual acuity due to microbial keratitis among users of the silicone hydrogel contact lens is low, the overall rate of presumed microbial keratitis with the wearing schedule of as many as 30 nights is similar to that previously reported for conventional continuous-wear soft lenses worn for fewer consecutive

nights. 46 This means that corneal hypoxia cannot be the sole mechanism that causes infectious keratitis and that other possible mechanisms need to continue to be researched. The Future Looks Bright Practitioners and researchers are gradually realizing that the lens with the highest Dk/T is not automatically the lens that will provide superior ocular health and comfort, and that other lens characteristics are just as significant. CooperVision s new silicone hydrogel, Biofinity (comfilcon A), combines a high Dk (128 barrers) with relatively low modulus, which appears to offer a better balance of Dk to modulus. In a clinical trial of Biofinity versus the Focus Night & Day and PureVision, Biofinity s continuous wear performance was superior in terms of comfort, vision and overall preference. 47 Biofinity is due on the market very soon and many practitioners are eager for its arrival. From the Permalens 71% introduced by DeCarle in the early 1970 s to CooperVision s Biofinity set to be released this year, continuous wear has steadily advanced. Thanks to years of dedicated efforts of clinical and institutional researchers like the ones mentioned here, practitioners and patients alike now benefit from healthier, safer, and more convenient options in contact lens wear. Despite the amazing progress that has been made, there are a number of potential areas of research that need to be explored for continuous wear to maintain its progress. It is our duty, as students and practitioners, to investigate these issues and to sustain the exceptional efforts that have been put forth over the last 40 years. With a continued worldwide collaboration in continuous wear research and development, there is no limit to what can be accomplished.

REFERENCES 1. Morgan PB, et al. International contact lens prescribing in 2006. Contact Lens Spectr 2007;22(1):34-38. 2. Tolbert M, Lippman RE. Are your contact lenses as safe as you think? FDA Consumer 1987;21(3). 3. Schein OD, Poggio EC. Ulcerative keratitis in contact lens wearers. Incidence and risk factors. Cornea 1990;9 Suppl 1:S55-8; discussion S62-3. 4. Smelser GK, Ozanics V. Importance of atmospheric oxygen for maintenance of the optical properties of the human cornea. Science 1952;115:140. 5. Hill RM Fatt I. Oxygen measurements under a contact lens. Am J Optom Arch Am Acad Optom 1964;41:382-7. 6. Hill RM Fatt I. Oxygen uptake from a reservoir of limited volume by the human cornea in vivo. Science 1963;142:1295-7. 7. Hill RM Fatt I. Oxygen deprivation of the cornea by contact lenses and lid closure. Am J Optom Arch Am Acad Optom 1964;41:678-87. 8. Polse KA, Mandell RM. Critical oxygen tension at the corneal surface. Arch Ophthalm 1970;84:505-508. 9. Decarle J. Developing hydrophilic lenses for continuous wearing. Aust J Optom 1972;55(9):343. 10. Ezekiel DF. High water content hydrophilic contact lenses. Aust J Optom 1974;57:317-324. 11. Hamano H. Study shows injuries occur more frequently to soft lenses with high water content. Optom Observ Cont Lens News 1978;3(2). 12. Zantos SG Holden BA. Ocular changes associated with continuous wear of contact lenses. Aust J Optom. 1978; 61:418-426. 13. Mandell RB, Farrell R. Corneal swelling at low atmospheric oxygen pressures. Invest Opthalmol Vis Sci 1980;19(6):697-702. 14. Mizutani Y, Matsunaka H, Takemoto N. The effect of anoxia on the human cornea. Acta Soc Ophthalmol Jpn 1983;87:644-649. 15. Holden BA, Sweeney DF, Sanderson G. The minimum precorneal oxygen tension to avoid corneal edema. Invest Ophthalmol Vis Sci 1984;25:476-480.

16. Barr JT. History and development of contact lenses. In: Bennett E, Weissman B, eds. Clinical contact lens practice. Philadelphia: Lippincott Williams & Wilkins 2005:1-10. 17. Fatt I Lin D. Oxygen tension under a soft or hard, gas-permeable contact lens in the presence of tear pumping. Am J Optom Physiol Opt 1976;53(3):104-11. 18. Polse KA. Factors controlling oxygen tension under a hydrogel contact lens. J Am Optom Assoc 1981;52(3):203-8. 19. Benjamin WJ, Rasmussen MA. The closed lid tear pump: oxygenation? Int Eyecare 1985;1:251-257. 20. Holden BA, Mertz GW. Critical oxygen level to avoid corneal edema for daily and extended wear contact lenses. Invest Ophthalmol Vis Sci 1984;25:1161-1167. 21. La Hood D, Sweeney DF, Holden BA. Overnight corneal edema with hydrogel, rigid gas-permeable and silicone elastomer contact lenses. Int Contact Lens Clinic 1988;15:149-154. 22. Holden BA, Sweeney DF, Vannas A, et al. Effects of long-term extended contact lens wear on the human cornea. Invest Ophthalmol Vis Sci 1985;26:1489-1501. 23. Zantos S. Cystic formations in the corneal epithelium during extended wear of contact lenses. Int Contact Lens Clinic 1983;10(3):128-146. 24. Holden BA, Mertz GW, McNally J. Corneal swelling response to contact lenses worn under extended wear conditions. Inv Ophthalmol Vis Sci 1983;24(2):218-226. 25. Holden BA, Sweeney DF, La Hood D, Kenyon E. Corneal deswelling following overnight wear of rigid and hydrogel contact lenses. Curr Eye Research 1988;7(1):49-53. 26. Fonn D, Holden BA. Rigid gas-permeable vs. hydrogel contact lenses for extended wear. Am J Optom Physiol Opt 1988;65(7):536-44. 27. Galentine PG, Cohen EJ, Laibson PR, Adams CP, Michaud R, Arentsen JJ. Corneal ulcers associated with contact lens wear. Arch Ophthalmol 1984;102(6):891-4. 28. Weissman BA, Mondino BJ, Pettit TH, Hofbauer JD. Corneal ulcers associated with extended-wear soft contact lenses. Am J Ophthalmol 1984;97(4):476-81. 29. Schein O, Glynn R, Poggio E, et al. The relative risk of ulcerative keratitis among users of daily wear and extended wear soft contact lenses. N Engl J Med 1989;321(12):773-778.

30. Poggio E, Glynn R, Schein O, et al. The incidence of ulcerative keratitis among users of daily wear and extended wear soft contact lenses. N Engl J Med 1989;321(12):779-783. 31. Aswad MI, John T, Barza M. Bacterial adherence to extended wear soft contact lenses. Ophthalmology 1990;97(3):296-302. 32. Freudenheim M. Business and health; damage control on contact lenses. New York Times 1989 Sep 26. 33. Kotow M, Holden BA, Grant T. The value of regular replacement of low water content contact lenses for extended wear. J Am Optom Assoc 1987;58(6):461-4. 34. Tsubota K, Yamada M. Corneal epithelial alterations induced by disposable contact lens wear. Ophthalmology 1992;99(8):1193-6. 35. Buehler PO, Schein OD, Stamler JF, Verdier DD, Katz J. The increased risk of ulcerative keratitis among disposable soft contact lens users. Arch Ophthalmol 1992;110(11):1555-8. 36. Fleiszig SM, Efron N, Pier GB Extended contact lens wear enhances Pseudomonas aeruginosa adherence to human corneal epithelium. Invest Ophthalmol Vis Sci 1992;33(10):2908-16. 37. Elder MJ, Stapleton F, Evans E, Dart JK. Biofilm-related infections in ophthalmology. Eye 1995;9(Pt 1):102-9. 38. Friends GD, Kunzler JF, Ozark RM. Recent advantages in the design of polymers for contact lenses. Macromolecular Symposia 1995;98:619-631. 39. Fonn D, MacDonald KE, Richter D, Pritchard N. The ocular response to extended wear of a high Dk silicone hydrogel contact lens. Clin Exp Optom 2002 May;85(3):176-82. 40. Dumbleton K. Adverse events with silicone hydrogel continuous wear. Cont Lens Anterior Eye 2002;25(3):137-46. 41. Fonn D, Bruce AS. A review of the Holden-Mertz criteria for critical oxygen transmission. Eye Contact Lens 2005;31(6):247-51. 42. Harvitt DM, Bonanno JA. Re-evaluation of the oxygen diffusion model for predicting minimum contact lens Dk/t values needed to avoid corneal anoxia. Optom Vis Sci 1999;76(10):712-9. 43. Brennan NA. Corneal oxygenation during contact lens wear: comparison of diffusion and EOP-based flux models. Clin Exp Optom 2005;88(2):103-8.

44. Brennan NA. Beyond flux: total corneal oxygen consumption as an index of corneal oxygenation during contact lens wear. Optom Vis Sci 2005;82(6):467-472. 45. Gurdal C, Aydin S, Kirimlioglu H, Toprak E, Sengor T. Effects of extended wear- soft contact lenses on the ocular surface and central corneal thickness. Ophthalmologica 2003;217(5):329-336. 46. Schein OD, McNally JJ, Katz J, Chalmers RL, Tielsch JM, Alfonso E, Bullimore M, O'Day D, Shovlin J. The incidence of microbial keratitis among wearers of a 30-day silicone hydrogel extended-wear contact lens. Ophthalmology 2005;112(12):2172-9. 47. Brennan NA, Coles ML, Connor HR, McIlroy RG. A 12-month prospective clinical trial of comfilcon A silicone-hydrogel contact lenses worn on a 30-day continuous wear basis. Cont Lens Anterior Eye 2007 Apr 7;[Epub ahead of print].