QuickHeat TM Packaged Heat Exchanger Solutions

Similar documents
Spirax Compact FREME Flash Recovery Energy Management Equipment

TSS21 Sealed Thermostatic Steam Tracer Trap

DF1 and DF2 Diffusers

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

Dri-Line Mk3 Monnier Compressed Air Drain Trap

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

TP1 and TP2 Temporary Cone Shaped Strainers

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

FV Flash Vessel Installation and Maintenance Instructions

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

DCV10 Stainless Steel Disc Check Valve for use with Condensate Pumps

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

Fig 1, Fig 12, Fig 13, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

CP10 Sensor Installation and Maintenance Instructions

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

IFTGS14 Ball Float Steam Trap ½" and ¾" with Integral Spiratec Sensor

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

PV4 and PV6 Piston Valves

Manual Actuated Boiler Blowdown Valves

DCV1, DCV3 and DCV3LT Disc Check Valves Installation and Maintenance Instructions

APT14, APT14HC and APT14SHC Spares 2

CVS10 Sanitary Check Valves

AE14 Automatic Air Vents for Liquid Systems Installation and Maintenance Instructions

MF2M Monnier Miniature Compressed Air Filter

FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1")

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

AVM7 Stainless Steel Thermostatic Air Vent

MFP14-PPU (Vented) Automatic Packaged Pump Units

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

Type 130 and HL10 'Safeguard High Limit Control' Installation and Maintenance Instructions

DCV6 Disc Check Valve

AVC32 Carbon Steel Air Vent for Steam Systems

SA Control Valve types: BM, BMF, BX, SB, NS, KA, KB, KC (Normally open) BMRA, BMFRA, BXRA, SBRA, NSRA, KX, KY (Normally closed)

AE30 Automatic Air Eliminators / Air and Gas Vents for Liquid Systems

SRV66 Sanitary Pressure Reducing Valve

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

ML3M Monnier Miniature Compressed Air Lubricator

BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps

BCV31 DN40 - Blowdown Control Valve

M33F ISO, M33S ISO and M33V ISO Ball Valves Installation and Maintenance Instructions

Fig 3, 7, 33, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers

Airodyn, BRair and BRoil Compressed Air Drain Traps

CA44, CA44S, CA46 and CA46S Air and Gas Traps

PC10HP Pipeline Connector (ASME 600)

S and SF Inverted Bucket Steam Traps

CS10-1 Stainless Steel Clean Steam Separator

TW Temperature Control Valve

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats

M10HTi ISO Tobacco Ball Valve Screwed, SW, BW and Flanged versions

M111 Spiraflo Transducer

BPT13 Balanced Pressure Thermostatic Steam Traps

MPC1M, MPC2M and MPC2AM Monnier High Efficiency Compressed Air Filter / Regulators

BCV31 DN20 - Blowdown Control Valve

TDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions

BT6-B Sanitary Balanced Pressure Thermostatic Steam Trap

M70i ISO and M80i ISO Stainless Steel Ball Valves for Sanitary Systems Installation and Maintenance Instructions

Fig 7, 33, 33.1, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers Installation and Maintenance Instructions

BRV71 and BRV73 Pressure Reducing Valves

CA10S, CA14 and CA14S Air and Gas Traps

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats Installation and Maintenance Instructions

FT53, IFT53, FT54, IFT54, FT57 and IFT57 Ball Float Steam Traps - DIN

SRV2S Pressure Reducing Valve

BDV1 and BDV2 Blowdown / Depressurisation Valves

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

STERI-TROL Clean Service 'S' Series Two-port Control Valves DN15 (½") to DN100 (4")

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

Vane Flow Switches Colima FLU Series

SCA Series Inverted Bucket Steam Traps

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

Thermocirc Installation and Maintenance Instructions

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

BCVi43 Blowdown Control Valve

BDV60 Blowdown Vessel Installation and Maintenance Instructions

FT16 Ball Float Steam Trap Installation and Maintenance Instructions

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

Spirax SafeBloc TM DBB3 Double Block and Bleed Bellows Sealed Stop Valve. 1. Safety information. 2. General product information. 3.

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

CA16 and CA16S-14 Air and Gas trap Installation and Maintenance Instructions

SRV461S and SRV463S Stainless Steel Direct Acting Pressure Reducing Valves

STD Spray Type Desuperheater

LP31 Level Probe. 1. Safety information. 2. General product information. 3. Installation. 4. Wiring. 5. Maintenance

TD10, TD52M and TD259 Thermodynamic Steam Traps Installation and Maintenance Instructions

FT43, FT44, FT46 and FT47 Ball Float Steam Traps Installation and Maintenance Instructions

PC3000, PC3001 and PC4000, PC4001 Pipeline Connectors

VAD Variable Area Desuperheaters

LP10-4 Level Probe. 1. Safety information. 2. General product information. 3. Installation. 4. Wiring. 5. Maintenance IM-P402-92

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

BTD52L Thermodynamic Steam Trap Installation and Maintenance Instructions

Standard Pressure Powered Pump Packaged Units to Size 3 x 2 Type PPEC, PTC & PTF with vented and ASME coded receivers

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

1. General safety information. 2. General product information. 3. Installation. 4. Commissioning. 5. Operation. 6. Maintenance. 7.

Fig 1, Fig 12, Fig 13, Fig 14, Fig 16 and Fig 16L Strainers Installation and Maintenance Instructions

FTC62 and FTS62 Ball Float Steam Traps Installation and Maintenance Instructions

Transcription:

4831999/1 IM-P483-03 CH Issue 1 QuickHeat TM Packaged Heat Exchanger Solutions Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Operation 6. Maintenance IM-P483-03 Printed in the CH UK Issue 1 Copyright 2006 1

1. Safety information Pressure equipment not bearing the mark is classified 'Sound Engineering Practice' in accordance with Article 3, Paragraph 3 of the Pressure Equipment Directive 97/23/EC. It is the responsibility of the user to ensure that the product is installed and operated safely. Detailed product information including installation, operation and maintenance instructions can be obtained from www.spiraxsarco.com or by contacting your local Spirax Sarco sales office. Note: By law, SEP products cannot be marked with the symbol. Note This document refers only to the mechanical installation and commissioning of the unit and should be used in conjunction with the IMI's and supplementary safety information for all the relevant system components. Warning Your attention is drawn to Safety in accordance with any National or Regional regulations. This product is designed and constructed to withstand the forces encountered during normal use. Use of the product for any purpose other than its intended use could cause damage to the product and may cause injury or fatality to personnel. Before any installation or maintenance procedure, always ensure that all primary steam and condensate return lines and secondary water lines are isolated. Ensure any residual internal pressure in the system or connecting pipework is carefully relieved. Allow hot parts to cool before commencing work, to avoid the risk of burns. Always wear appropriate safety clothing before carrying out any installation or maintenance work. 1.1 Intended use i) Check that the product is suitable for use with the intended fluid. ii) Check material suitability, pressure and temperature and their maximum and minimum values. If the maximum operating limits of the product are lower than those of the system in which it is being fitted, or if malfunction of the product could result in a dangerous overpressure or overtemperature occurrence, ensure a safety device is included in the system to prevent such over-limit situations. iii) Determine the correct installation situation and direction of fluid flow. iv) Spirax Sarco products are not intended to withstand external stresses that may be induced by any system to which they are fitted. It is the responsibility of the installer to consider these stresses and take adequate precautions to minimise them. v) Remove protection covers from all connections before installation. Safe operation of these products can only be guaranteed if they are properly installed, commissioned, used and maintained by qualified personnel (see Section 1.11) in compliance with the operating instructions. General installation and safety instructions for pipeline and plant construction, as well as the proper use of tools and safety equipment must also be complied with. 1.2 Access Ensure safe access and if necessary a safe working platform (suitably guarded) before attempting to work on the product. Arrange suitable lifting gear if required. 2 IM-P483-03 CH Issue 1

1.3 Lighting Ensure adequate lighting, particularly where detailed or intricate work is required. 1.4 Hazardous liquids or gases in the pipeline Consider what is in the pipeline or what may have been in the pipeline at some previous time. Consider: flammable materials, substances hazardous to health, extremes of temperature. 1.5 Hazardous environment around the product Consider: explosion risk areas, lack of oxygen (e.g. tanks, pits), dangerous gases, extremes of temperature, hot surfaces, fire hazard (e.g. during welding), excessive noise, moving machinery. 1.6 The system Consider the effect on the complete system of the work proposed. Will any proposed action (e.g. closing isolation valves, electrical isolation) put any other part of the system or any personnel at risk? Dangers might include isolation of vents or protective devices or the rendering ineffective of controls or alarms. Ensure isolation valves are turned on and off in a gradual way to avoid system shocks. 1.7 Pressure systems Ensure that any pressure is isolated and safely vented to atmospheric pressure. Consider double isolation (double block and bleed) and the locking or labelling of closed valves. Do not assume that the system has depressurised even when the pressure gauge indicates zero. 1.8 Temperature Allow time for temperature to normalise after isolation to avoid danger of burns. 1.9 Tools and consumables Before starting work ensure that you have suitable tools and/or consumables available. Use only genuine Spirax Sarco replacement parts. 1.10 Protective clothing Consider whether you and/or others in the vicinity require any protective clothing to protect against the hazards of, for example, chemicals, high/low temperature, radiation, noise, falling objects, and dangers to eyes and face. 1.11 Permits to work All work must be carried out or be supervised by a suitably competent person. Installation and operating personnel should be trained in the correct use of the product according to the Installation and Maintenance Instructions. Where a formal 'permit to work' system is in force it must be complied with. Where there is no such system, it is recommended that a responsible person should know what work is going on and, where necessary, arrange to have an assistant whose primary responsibility is safety. Post 'warning notices' if necessary. IM-P483-03 CH Issue 1 3

1.12 Handling Manual handling of large and/or heavy products may present a risk of injury. Lifting, pushing, pulling, carrying or supporting a load by bodily force can cause injury particularly to the back. You are advised to assess the risks taking into account the task, the individual, the load and the working environment and use the appropriate handling method depending on the circumstances of the work being done. Lifting The QuickHeat TM unit should be lifted by a suitable forklift truck, from the base, placed in position and securely bolted to the floor. Note: - On no account is the unit to be lifted by any other part, other than the base. - Sufficient space should be provided in its location to allow access for maintenance. - The unit occupies a maximum of 4.1 m³ space. The maximum footprint is 2205 x 2200 x 840 mm. 1.13 Residual hazards In normal use the external surface of the product may be very hot. Many products are not self-draining. Take due care when dismantling or removing the product from an installation. 1.14 Freezing Provision must be made to protect products which are not self-draining against frost damage in environments where they may be exposed to temperatures below freezing point. 1.15 Disposal Unless otherwise stated in the Installation and Maintenance Instructions, this product is recyclable and no ecological hazard is anticipated with its disposal providing due care is taken. 1.16 Returning products Customers and stockists are reminded that under EC Health, Safety and Environment Law, when returning products to Spirax Sarco they must provide information on any hazards and the precautions to be taken due to contamination residues or mechanical damage which may present a health, safety or environmental risk. This information must be provided in writing including Health and Safety data sheets relating to any substances identified as hazardous or potentially hazardous. 4 IM-P483-03 CH Issue 1

2. General product information 2.1 Product nomenclature Condensate control valve version QuickHeat TM QH = Packaged heat exchanger system QH Heat load 2C = 50 to 300 kw 3C = 300 to 1 300 kw 4C = 1 300 to 3 300 kw 5C = 3 300 to 5 000 kw 2C Piping configuration S = Standard S Valve actuation PN = Pneumatic EL = Electric PN Selection example A QuickHeat TM unit with a pneumatically actuated condensate control valve. The nomenclature for the above selection would be displayed as follows: QH2C - S - PN Steam control valve version QuickHeat TM QH = Packaged heat exchanger system QH Heat load Piping configuration Valve actuation Condensate removal 2S = 100 to 400 kw 3S = 400 to 1000 kw 4S = 1 000 to 4 000 kw 5S = 4 000 to 10 000 kw S = Standard FR = Fast response PN = Pneumatic EL = Electric APT = Automatic pump trap FT = Float and thermostatic steam trap 2S S PN APT Selection example A QuickHeat TM unit with a fast response piping arrangement, having a primary pneumatically actuated steam control valve and an automatic pump-trap. The nomenclature for the above selection would be displayed as follows: QH2S - S - PN - APT IM-P483-03 CH Issue 1 5

2.2 General information QuickHeat TM systems are available in two main versions: 1. Supplied with a condensate control valve. 2. Supplied with a primary steam control valve. Both versions use steam as the primary energy source, and provide accurate control of low temperature hot water for heating purposes, domestic hot water or hot water for processes. Systems can be sized for any heating duty from 50 kw to approximately 10 MW and are supplied fully assembled and tested ready for installation. The QuickHeat TM unit consists of the following items (refer to Figures 1 and 2): - Fully welded Plate & Shell heat exchanger. - Pneumatic or electrically actuated control valve and positioner. - Controller and sensor. - Condensate removal solution (either a float trap or an automatic pump-trap). - Ancillaries. - Secondary circuit isolation valves. - Internal recirculation pump on fast response units. - Internal injection valve on fast response units. Note: For additional information about any particular product used in the construction of this unit see the relevant Technical Information Sheet. Fig. 1 QuickHeat TM (QH_C condensate control version) 6 IM-P483-03 CH Issue 1

3. Installation Warning: Before proceeding with any installation or maintenance work read Section 1, Safety information. 3.1 Steam and condensate connections It is paramount that the required amount of dry clean steam is supplied to the QuickHeat TM, in accordance with good steam engineering practice. In some instances, dry steam may be achieved by careful construction of the steam supply pipework and the proper positioning of the correct type of steam trap; in others, it may necessitate the installation of a steam separator (Spirax Sarco can advise). It should also be ensured that all connecting pipework is stress free and adequately supported. QuickHeat TM must not operate above the maximum steam pressure and temperature indicated on the name-plate attached to the unit. QuickHeat TM contains all of the carefully matched components necessary to ensure its performance meets expectations. Spirax Sarco can advise on and provide complementary products or systems to ensure the QuickHeat TM system always operates safely and at the peak of its capability. We especially recommend that an independent high limit safety shut-off system be considered when heating water for personal use, or in process applications where overheating could be dangerous or create a costly shutdown, and that it should always be fitted where local regulations require it. It is recommended that the high limit safety system should isolate the steam supply to the QuickHeat TM in the event of either an overtemperature or loss of hydraulic pressure in the secondary water system. Care should be taken to ensure that a differential exists between the normal operating set point and the high limit set point, to avoid superfluous high limit shut-off. In most cases, because of the high maximum operating pressure and temperature limits of QuickHeat TM components, extra pressure reducing valve stations and safety valves are not required to maintain integrity. Spirax Sarco offers a complete solution to users of QuickHeat TM, including initial evaluation, correct sizing and selection, and installation and commissioning. 3.2 Air supply If a pneumatic control system is installed, connect a compressed air supply to the pressure regulator mounted on the control valve positioner. Air supply 4.5 to 8 bar g (65 to 116 psi g) 3.3 Electrical supply All electrical wiring and connections should be carried out in accordance with National regulations and Standards. Electrical supply Actuators Bypasss solenoid valve (FR type only) Bypass pump (FR type only) Power supply: 230 Vac / 50 Hz Supply fuse: 5A (T) 24 Vac 20 Vac / 50 Hz 230 Vac / 50 Hz 8 IM-P483-03 CH Issue 1

4. Commissioning We recommend the service and support of a Spirax Sarco Commissioning Engineer. Details of this service can be found by contacting Spirax Sarco. Note: It is usual, in new piping installations, for dirt and foreign bodies to collect in the steam line during construction. It is essential to flush out new steam lines prior to apparatus being connected, and check and clean all relevant pipeline strainers prior to commissioning. 4.1 Commissioning procedure: - Ensure the steam inlet valve upstream of the QuickHeat TM remains shut, thus isolating the steam supply. - Check all electrical connections are secure and as per installation drawing. - Dry commissioning valve stroke check - An initial valve stroke check should be carried out before the steam supply is turned on, to ensure free movement of the valve stem. - Open all condensate drain valves. - Switch off electrical power. - Open secondary isolating valves downstream of the QuickHeat TM. - Start the main secondary water circulating pump(s). - Check to ensure the secondary water is circulating through the QuickHeat TM. - If the secondary circulation is okay, and after ensuring that the voltage and frequency are correct, switch on the power to the unit via the local switch fuse. - Switch on the QuickHeat TM main switch, (switch adjacent to the controller). Note: Ensure the controller temperature setting is suitable for the application. If this needs to be altered, refer to the 'Controller Manual'. - Slowly open the primary steam isolating valve to the QuickHeat TM, to allow the supply steam pressure to increase slowly to the required value. When the required pressure is reached and no abnormalities are observed, open the valve fully. - Check that the QuickHeat TM secondary outlet temperature is within the acceptable limits of the set point.. - If necessary adjust PID settings, (see DB-S27-08, 'Selecting PID settings'). Spirax Sarco strongly recommends that only a suitably trained controls engineer adjust these parameters. - Check operation of steam traps / condensate pump to ensure that condensate is being removed from the heat exchanger throughout the complete heat load cycle, from full load to minimum load. - Check for leaks. The QuickHeat TM unit is now ready for service. IM-P483-03 CH Issue 1 9

5. Operation 5.1 QuickHeat TM with condensate control valve The condensate control valve automatically modulates the available heating area within the Plate & Shell heat exchanger to match the required heat demand. The control valve is either pneumatically or electrically actuated and the system uses a Pt100 temperature sensor and temperature controller for precise control. This version requires a constant pressure steam supply to maintain a constant steam temperature in the heat exchanger. The steam pressure in the heat exchanger must be higher than the condensate backpressure at all times, and the water pressure in the secondary circulation system must be higher than the highest operating steam pressure. This version gives accurate temperature control when used for heating and process hot water with slow changes in heat load. 5.2 QuickHeat TM with steam control valve The steam flowrate is automatically modulated to match the heat demand by the steam control valve. The control valve is either pneumatically or electrically actuated and the system uses a Pt100 temperature sensor and temperature controller for precise control. The pumping trap version can operate at low or even sub-atmospheric steam pressure, in areas where there is a risk of scaling of the heat exchanger in open circuit installations such as a domestic hot water application. This version can be used for domestic hot water, heating and process hot water. Accurate temperature control is provided whatever the requirements for fast or slow changes in heat load. 10 IM-P483-03 CH Issue 1

6. Maintenance 6.1 General For maintenance of the individual components of the system, please see the relevant IMI s for the products concerned. 6.2 Scale formulation Within open systems, such as domestic hot water systems supplying hot water to basins, baths and showers, and where there is continual make-up water, there is a risk of scale formation as the make-up water is unlikely to be chemically treated. The extent of the scale will depend largely upon the water quality, which varies greatly upon the geographical area and the site parameters. A thorough test conducted by a water treatment specialist is recommended; to determine and consider water quality and the condensing temperature, and whether scaling problems are foreseen which will subsequently require attention prior to the QuickHeat TM being specified or ordered. After extended service - If scale becomes a persistent problem, regular chemical cleaning should be considered. ¾" ports are available on the secondary inlet and outlet piping to allow easy connection for 'Clean in Place' apparatus. It should be noted that raising the steam pressure could result in an increase of scaling. 6.3 High limit testing device The purpose of this test is to ensure the QuickHeat TM safety system operates satisfactorily when required to do so. Method 1. High limit temperature set point test The temperature set point of the high limit controller should be lowered, to simulate an overtemperature on the system. The responsible or competent person should ensure the high limit device operates in a satisfactory manner. 2. Low limit secondary pressure test (if fitted) The static water pressure in the secondary circulation system should be reduced to test the high limit control valve. (It is recommended that the secondary water circulation pumps be turned off for this test). 3. Electrical power failure test The QuickHeat TM should be turned off at the controller to simulate an electrical power failure. An examination should be made to ensure that the high limit system has switched to its failsafe mode, thus isolating the steam supply. Frequency It is essential that a responsible or competent person tests the high limit device on a regular and frequent basis. Intervals between tests should not exceed a six month period. Spirax Sarco does not recommend the installation of a self-acting high limit system to QuickHeat TM. IM-P483-03 CH Issue 1 11

12 IM-P483-03 CH Issue 1