1.3 LIMITATIONS: The following application limitations must be recognized and considered before using this product:

A variety of other devices can be used with the front dee ring, but please check for suitability.

RIGGERS SAFETY SAFETY IS IN THE DETAILS FULL LINE CATALOG

Kee Anchor Operation & Maintenance Manual

??????? is committed to providing a safe work environment for its employees and preventing occupational injuries due to falls.

User Instructions 1790 Rail Anchor

SECTION FACILITY FALL PROTECTION PART I - GENERAL

INSTALLATION AND USAGE HANDBOOK

User Instructions 1789 Parapet Wall Anchor

User Instruction Manual

Fall Protection Checklist. Guardrail System

MSA Latchways Ladder System

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

HEIGHT SAFETY. Elasticised shock absorbing Lanyard Twin tail lanyard allowing transfer to adjacent anchors

1.2 LIMITATIONS: Consider the following application limitations before using this equipment:

Installation, Operating, Inspection and Maintenance Instructions Ladder Climber s Safety System. Warning

USER S INSTRUCTION MANUAL FOR THE INSTALLATION, OPERATION & MAINTENANCE OF THE GUARDIAN TEMPORARY HORIZONTAL LIFELINE SYSTEM

Instructions for the following series products:

Kratos Safety FA FA FA FA POINT LUXURY FULL BODY HARNESS

ROOF ANCHOR / D-RING ANCHOR PLATE

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

Reliance Industries, LLC Operating instructions for the / Bolt-on D-Ring Anchorage. Model # 3071

User Manual 1792 Standing Seam Metal Roof Retractable Swivel Anchor

GM-121: Container End Lock Anchor Wand Page 1 WINSAFE CORP. GM 121 CONTAINER END LOCK ANCHOR WAND OPERATING INSTRUCTIONS AND MAINTENANCE

You may order this publication from WCB Publications and Videos, Please quote ordering number BK60.

Floor Mount Socket. T: +44 (0) F: +44 (0)

Instruction Manual AC350 GUIDED-TYPE FALL ARRESTER ON RIGID ANCHORAGE LINE EN 353-1:2002

Fall Protection Refresher Orientation. Fall Protection Refresher Orientation 1

FALL PROTECTION (SAF-SPI-06)

Figure 1 - Snap Hooks and Carabiners PART NUMBER MANUFACTURER S ID YEAR OF MANUFACTURE PART NUMBER MANUFACTURER S ID YEAR OF MANUFACTURE

TRAVSMART permanent single-cable horizontal lifeline system

A GUIDE TO BUYING FALL ARREST EQUIPMENT. uk.rs-online.com (UK customers) (International customers)

FALL RANGE PROTECTION

Overview (key points)

11.4 FALL-ARREST SYSTEM AND EQUIPMENT CHECKLIST (Must answer yes to all applicable questions)

FALL PROTECTION GUIDELINE

User Instruction Manual Fixed Beam Anchor

FREQUENTLY ASKED QUESTIONS ABOUT FALL PROTECTION

New Mexico Institute of Mining & Technology. Fall Protection Program

Operating instructions. Bolt-on Bar Joist Anchorage

Fall Protection Training

WINSAFE CORP. OPERATING AND MAINTENANCE INSTRUCTIONS GM184 TOP ACCESS END LOCK ANCHOR WAND

GM-120: Container Top Lock Anchor Wand Page 1 WINSAFE CORP. GM 120 CONTAINER TOP LOCK ANCHOR WAND OPERATING INSTRUCTIONS AND MAINTENANCE

Security and confidence at height.

Installation & User Manual

Safe Work Practices (SWP) SWP (6) FALL PROTECTION PROGRAM

Product Name: Hold Me Rope Anchor

Operating manual Mobile Man Anchor IM-200 Reference No. IM 200

Anchorages. Beam Anchors 136 Horizontal Safety Lines 137 Anchorage Lines 138 Rope Grabs 139 Hard Point Anchors 140 Attachment Slings 141

ARKANSAS TECH UNIVERSITY FACILITIES MANAGMENT HEALTH AND SAFETY MANUAL

Product Name: Angel Anchor

Assembly, Installation and operating. instructions for. Söll-Xenon anchorage device

Product Name: Rope Grab

Installation and Operation Instruction Manual

User Instruction Manual Roof Anchor and / Sayfline Horizontal Lifeline System

Product Name: 2-Way Standing Seam Roof Clamp

SpanSet Gotcha CRD User Instructions. SpanSet Certified Safety

Operation and Instructional Techniques Manual

DREW UNIVERSITY FALL PROTECTION PROCEDURE (DRAFT 12/11)

User Instruction Manual For Davit Rescue System

Welcome. 2

Figure 1 - Parts Identification. Copyright 2002, DB Industries, Inc.

Develop and sign off on risk assessment/work method statement for the task, considering task specifics elements that will affect the user s safety:

Instructions for Dual Retractable Web lanyards Type 1. Instructions for E6 Energy Absorbing Y, Bypass Lanyards. For Worker Mass Range of 90 to 175 kg

Section 16B. Fall Protection. Falls are the second leading cause of death in the workplace. Factors contributing to falling incidents:

Rescue Assist Kit. The Rescue Kit Includes:

rooftop anchor Standing Seam Metal Roofs

Fall Protection STANDARD PROCEDURE INSTRUCTION. Fall Protection. Title SPI. Department. Supersedes SPI Dated. Jan 19, 2016.

Deans, Directors, Heads of Schools and Departments and Research Institute Directors and Managers

SPYDA TEMPORARY ANCHOR POINT

User Instruction Manual Fixed Beam Anchor

Compliance In A Can. Contents 1.0 HOW TO USE THIS MANUAL

Fall Control User Instructions

8. Fall Protection Procedures WAC

Know Your ABCs FALL PROTECTION GUIDE

At the end of this presentation you should know the difference between fall prevention, fall restraint, and fall arrest.

Product Name: Beamer Trolley Anchor

Product Name: Concrete Anchor Strap

CLIMA Vertical Line Instructions

USER INSTRUCTION MANUAL CONCRETE BOLT ANCHORAGE CONNECTOR

Vertical Lifeline. Ladder Climb. User Instructions. 3M Occupational Health and Environmental Safety. Fall Protection Equipment

Operating instructions. Skyline Beam Clamp

GOTCHA CRD. Rescue, hoisting and abseiling equipment EN341 / EN1496 CE0158 TECHNICAL DATA

Fall Protection ABC s

Product Name: Bull Ring Anchor

GEMTOR. ... when your life is on the line OWNER'S MANUAL. FLW Series Self-Retracting Lanyard/Fall Limiter

SYSTEM OPERATION PROPRIETARY FALL ARREST SYSTEM SUITABLE FOR MULTIPLE USERS MANUAL SYSTEM CONTENTS MUST BE READ AND UNDERSTOOD PRIOR TO USE

Made in the USA. For Fall Protection Only. SafeLok Part Description

IMPORTANT: Record the product identification information from the ID label in the inspection and maintenance log in section 9.0 of this manual.

TRUSS ANCHORING. A guide on the use of Howe and Fink truss anchors

Transcription:

Think Safety, Think Safesite O&M - ANCHORAGE SYSTEMS

Anchorage Systems INTRODUCTION External works often require access from the inside of a premises as well as from the outside, for example, window cleaning or minor maintenance operations. In these cases, eyebolts, roof anchors and ladder restraints are the most common and user friendly solution to ensuring operative fall arrest safety. LEGISLATION BS 8213 Part 1: Windows, doors and rooflights provides guidance for designers on the reach limits in relation to cleaning. Should these limits need to be exceeded, then suitable anchorage points in accordance with BS EN 795: Protection against falls from height anchorage devices - Requirements and testing, need to be provided for the operative to attach via a lanyard and harness. These structural anchorage points should be installed and tested to BS 7883: Application and use of anchor devices conforming to BS EN 795. Regulation 16 of the Workplace (Health, Safety and Welfare) Regulations deals with the ability to clean windows etc safely. Under the Regulation, paragraph 156, suitable provisions should be made so that windows and skylights can be cleaned safely if they cannot be cleaned from the ground or other surface. Suitable provisions may include the fitting of access equipment or providing suitable conditions for the future use of mobile access equipment, including ladders up to 9m long. Where a ladder over 6m is required, suitable points for tying or fixing the ladder should be provided. Suitable and suitably placed anchorage points for safety harnesses should also be provided. The Work at Height Regulations 2005 require that the employer/building owner has a rescue plan and policy in place for all fall arrest systems INSTALLATION Installation is carried out in accordance with BS 7883. In relation to fall arrest products installed in brickwork or concrete, it is necessary to place an axial proof load test of 6kN for 15 seconds to confirm the fixing. In the case of through fixing, these are set to a torque of 35Nm. Ladder restraints require a tensile proof test load of 2.4kN for 15 seconds. ANNUAL RECERTIFICATION Fall arrest products should be recertified in accordance with BS EN 365: Personal Protective Equipment against falls from height - General requirements for instructions for use and for marking. This can be carried out by Safesite as a service contract and included within the quotation for the system. Where ladder restraints are concerned, there are no requirements for annual re-certification, however, the straps, ratchet and J hooks must be visually inspected by a competent person every time they are used. INSTALLATION - NATIONAL BALLET A number of permanent fall arrest eyebolts have been installed to enable safe maintenance to be carried out at the English National Ballet s headquarters at Markova House in London. Named after Dame Alicia Markova who was a co-founder of the English National Ballet, Markova House is a listed building. This meant that as well as providing a fall arrest solution, the installation also needed to complement the aesthetics of the building. Safesite s eyebolts provided the perfect solution by blending in with the building s façade and allowing general

Anchorage Systems maintenance work or window cleaning operations to be carried out without a threat of workers falling. Safesite offers both permanently installed eyebolts such as those used at Markova House, or removable systems where the sockets are permanent but the eyebolts can be removed when not in use. The eyebolts are available in a standard galvanised steel, stainless steel finish or can be white plastic coated. So that the installation did not detract from the building s aesthetics, white plastic coated eyebolts were specified for Markova House. INSTALLATION - WOLVERHAMPTON WFC Safesite s eyebolts have been installed at Molineux, the prestigious home of Wolverhampton Wanderers Football Club to ensure complete safety during maintenance work at the Club s new stands. Following the 20 million redevelopment of the Stadium, maintenance work to the new Jack Harris, John Ireland, Stan Cullis and Billy Wright Stands required frequent access to high level areas. Safesite carried out a professional inspection and risk assessment of the stands in conjunction with the Club s Management. With Safesite s comprehensive understanding of current health and safety legislation governing working at height, combined with an extensive range of products, it was decided that safe access to all the high level areas of the Stan Cullis and Billy Wright Stands was best achieved using three Safesite fall arrest systems. High level access to the Jack Harris and John Ireland Stands required separate assessment due to their differing architecture. Here it was decided that permanent fall arrest eyebolt fixings would provide the best anchorage protection for operatives working at high level. NOTE: When using fall arrest equipment such as eyebolts, it is essential that only fall arrest anchorages manufactured and installed to the requirements of BS 7883 and BS EN 795 are used and that the work is carried out by qualified companies experienced in the field of fall arrest installation.

Anchorage Systems Specifications PRODUCT SPECIFICATION GENERAL Cleaning windows may expose the window cleaner to potential fall risks. In these instances one may specify eyebolts in order to provide a Class A1 anchorage point to which a shock absorbing lanyard can be attached. The lanyard is then connected to the full body harness being worn by the operative. General guidance concerning reach limits and cleaning is provided within BS 8213 : Part 1 Windows doors and rooflights 225 100 INSTALLATION Kee i-bolts are installed and comply with the recommendations of BS EN 795 and BS 7883. The given structure must be of adequate construction to be able to sustain the likely imposed loads, this to be confirmed by a qualified engineer. PRODUCT MATERIAL & DESIGN Kee i-bolts are statically tested to 12kN and available in standard galvanised finish to BS EN ISO 1461 or Polyester White Gloss to BS 6496 amended and BS 6497 amended or stainless steel 316 grade. The structure determines the method of fixing as illustrated in the diagrams. MAINTENANCE - RECERTIFICATION BS EN 365 Personal Protective Equipment against falls from height - General requirements for instructions for use and for marking. The recertification procedure entails the removal of the eyebolt for visual inspection purposes to check for deterioration, re-insertion of the eyebolt together with a new identification tag providing the installation and re-testing dates. The eyebolt is then tested in tension to 6kN for 15 seconds by a competent person. Through fix eyebolts require the same examination, the eyebolt is then reinserted and the back nut torqued to 35Nm. Once recertification is completed the client is issued with the necessary certification and the Safesite database is updated accordingly. 150 Clear Opening Access box Resin Bond solid brickwork greater than 225mm Resin Bond 75 Stand off fix Dry Lining Resin Bond 175 Throughfix Cavity Wall Throughfix Steelwork Expansion anchor, resin bond or throughfix for concrete structures 55 Resin Bond into load bearing masonry

Anchorage Systems Specifications KEE ANCHOR BEAM Eyebolts cannot always be fitted for structural reasons, for example, dormer windows where the construction is mainly timber or dry lined. In many instances anchorage points are required to carry out short term inspections or maintenance and these very often are not provided. The Kee Anchor Beam is the ideal solution. Annual inspection is required by a competent person. 290mm 2150mm 850mm 1000mm 610mm 1300mm 1100mm A TYPICAL EYEBOLT POSITION MAXIMUM REACH LIMITS 290mm 150mm A TYPICAL EYEBOLT POSITION Adjustable 0.35m - 1.24m KEE ANCHOR BEAM - AT060 The Kee Anchor Beam for one person conforms to EN795 Class B. The anchorage point is fully adjustable (0.35-1.24m) and can be positioned in door/window reveals. Material : 316 grade stainless steel. Net weight : 6.9kg.

Anchorage Systems Specifications 75mm 152mm 75mm GALVANISED EYEBOLT - 5845-75G Internal/External fitting. Material : Drop forged galvanised finished BS EN ISO 1461 Net weight : 0.19kg 75mm 152mm GALVANISED EYEBOLT - 5845-152G Internal/External fitting. Material : Drop forged galvanised finished BS EN ISO 1461 Net weight : 0.28kg 152mm 75mm STAINLESS STEEL EYEBOLT - 5845-75S Internal/External fitting. Material : Drop forged Stainless Steel 316 grade finish. Net weight : 0.19kg 75mm 152mm STAINLESS STEEL EYEBOLT - 5845-152S Internal/External fitting. Material : Drop forged Stainless Steel 316 grade finish. Net weight : 0.28kg 152mm 75mm POLYESTER COATED EYEBOLT - 5845-75W Mainly for internal fitting. Material : Drop forged white polyester coated finish BS 6496 : 1984 and BS 6497 : 1984. Net weight : 0.19kg 100mm 152mm POLYESTER COATED EYEBOLT - 5845-152W Mainly for internal fitting. Material : Drop forged white polyester coated finish BS 6496 : 1984 and BS 6497 : 1984. Net weight : 0.28kg 60mm 60mm 100mm GALVANISED EYEBOLT - 5845-100G Internal/External fitting. Material : Drop forged galvanised finished BS EN ISO 1461 Net weight : 0.23kg. 100mm STAINLESS STEEL BACK PLATE - BPLATESQS Used on through fix as backing plate. Material : 316 grade Stainless Steel. Net weight : 0.152kg. 60mm 60mm 100mm STAINLESS STEEL EYEBOLT - 5845-100S Internal/External fitting. Material : Drop forged Stainless Steel 316 grade finish. Net weight : 0.23kg. 100mm GALVANISED BACK PLATE - BPLATESQG Used on through fix as backing plate. Material : Galvanised steel to BS EN ISO 146. Net weight 0.152kg. Ø 64mm 100mm POLYESTER COATED EYEBOLT - 5845-100W Mainly for internal fitting. Material : Drop forged white polyester coated finish BS 6496 : 1984 and BS 6497 : 1984. Net weight : 0.23kg. IDENTIFICATION DISC - PPEDISC-FA Used with all Fall Arrest Eyebolt installations Fall Restraint (PPEDISC-FR) & Work Positioning (PPEDISC-WP) Discs also available. Material : Plastic. Net weight : 0.003kg.

Anchorage Systems Specifications 100mm 135mm CONNECTOR M12 - COUP12X3G Used to extend fixings. Outside Dia 16mm. Material : Galvanised steel to BS EN ISO 146. Net weight : 0.08kg. 85mm KEYANKA EYEBOLT - KEY-KEY Quick release mechanism for Eyebolt removal. Material : Stainless Steel 316 Grade. Net weight : 0.16kg 75mm 110mm KNURLED INSERT - KNURL3MS Used on Eyebolt resin fix installations. Material : BZP Net weight : 0.8kg. 100mm KEYANKA CONCRETE SOCKET ASSEMBLY - KEY-CONC Insert for concrete where resin fix installation. Material : Stainless Steel 316 Grade. Net weight : 0.335kg 170mm KNURLED INSERT - KNURLM12MS Used on Eyebolt resin fix installations. Material : BZP Net weight : 0.106kg. KEYANKA BRICKWORK SOCKET ASSEMBLY - KEY-BRICK Insert for brick/stone where resin fix installation. Material : Stainless Steel 316 Grade. Net weight : 0.535kg 75mm 110mm KNURLED INSERT - KNURL3SS Used on Eyebolt resin fix installations. Material : Stainless steel Net weight : 0.8kg. KEYANKA STEELWORK SOCKET ASSEMBLY - KEY-STEEL Insert for steelwork. Material : Stainless Steel 316 Grade. Net weight : 0.295kg 100mm Ø 38mm KNURLED INSERT - KNURLM12SS Used on Eyebolt resin fix installations. Material : Stainless steel Net weight : 0.106kg. POLY WASHER - POLYWASH Used with all Eyebolt installations. Material : Neoprene. Net weight : 0.002kg.

Roofanka Specification BS EN 795 Class A2 Product Specification SLOPE MOUNTED ROOFANKA GENERAL Roofanka is designed to be used as a fall arrest single anchor point or as a structural anchor for those working on pitched roofs. When used for Fall Arrest, Roofanka serves as a fall arrest anchor, ladder hook and crawling board clamp for the attachment of harnesses and to secure roof ladders, crawling boards, work platforms etc. MATERIALS All components above the roof are 316 Grade stainless and internal components are galvanised steel to BS EN ISO 1461. DESIGN The designed system consists of a stainless steel eyebolt and steel clamping system that utilises the structural members of the roof s construction for support. The anchor is manufacturered to clamp around the following structural members:- Timber rafter, Angle Purlin, Multibeam B, Multibeam Purlin, Z-Purlin, I-Beam etc. Waterproofing is achieved via a piece of lead flashing and the Roofanka patended weatherproof seal DIRECTION OF LOADING Due to the potential weaknesses in timber roof structures, the basic models (product codes RANKAUK and RANKAEX) should only be used where the direction of loading would always be in the plane (i.e. down the slope) of the roof. Where it is possible that the arrest of a fall may result in forces applied across the roof structure (e.g. by a fall over a gable end), special versions of ROOFANKA should be employed. The addition of a lateral brace shares the bending moment with the adjacent rafter to resist potentially high torsional bending of the roof timbers. See product codes RANKAUK-GE and RANKAEX-GE Specification: EN 795 Class A2 and EN 517 Type A, one user only, with a maximum loading of 10kN. TESTING The system is fully tested and compliant with BS EN 795, BS 7883 and ISO 14567. ANNUAL RECERTIFICATION Re-certification is required annually in accordance to BS EN 365. Product Code RANKAUK RANKAUK-GE RANKAEX RANKAEX-GE Min. Roof member (mm) 72 x 35 72 x 35 135 x 65 135 x 65 Max. Roof member (mm) 152 x 65 152 x 65 220 x 120 220 x 120 Transverse forces OK? NO YES NO YES SLOPE MOUNTED ROOFANKA - RANKAUK Material : All components above the roof are 316 Grade stainless and internal components are galvanised steel to BS EN ISO 1461. Net weight : 5.9kg

Anchorage Systems Recertification Periodic inspections by a competent person are required under Regulation 5 of the Workplace (Health Safety & Welfare) Regulation, BS EN 365 & BS 7883. The frequency will depend upon environment, location and utilisation, but should be at least every 12 months. Check the system & configuration still serves the client s needs. Establish if any modifications, additional products are required to reflect any refurbishment or additional plant and equipment that has been installed and requires access. At least once every 12 months each anchor device and its structural steelwork should be examined by a competent person. Remove the demountable components and thoroughly examine for wear, defects & corrosion. Re-assemble all the components if satisfactory. After being re-assembled, each structural anchor should be submitted to an axial pull-out force of 6kN to confirm the soundness of the fixing. The structural anchor should sustain the force for a minimum of 15 seconds without deformation. Structural anchors that fail the test should be rejected. After testing, the structural fabric should be carefully examined for cracking or other signs of failure, and appropriate action taken if necessary. Should the structure fail, the hole should be plugged so preventing re-use and the device relocated in a sound structure. Should any given anchorage restrain a fall, then the eyebolt must be removed and discarded, the socket be plugged and a new anchorage fitted in a nearby suitable position. Anchorages in buildings which have been subject to fire and high temperature, impact damage or any similar detriment should be renewed. Check system plaque position & mark up to reflect date of the next required inspection. Establish if additional plaques are required due to any refurbishment works.

Safesite Ladder Restraint Specification PRODUCT SPECIFICATION GENERAL External window cleaning and general maintenance operations often require the use of ladders as a means of access. Statistically over 50% of accidents involving ladders occur due to ineffective means of securing and where the duration of works is 30 minutes or less. Generally ladders should only be used as a means of access and not as a working platform. It is essential that three points of contact are maintained. Over stretching must be avoided. LEGISLATION The Workplace (Health, Safety and Welfare) Regulations state Where a ladder over 6m long will be needed, suitable points for tying or fixing the ladder should be provided. Further information concerning access for cleaning is contained within BS 8213 : Part 1: Windows, doors and rooflights INSTALLATION The J hooks are resin fixed to the structure at approx 2-4m centres. Where possible they are installed at a height of approx 1.8-2.0 metres above the ground. Once installed they are tested to a tensile load of 2.5kN for 15 seconds. SYSTEM APPLICATION Ladder Restraint Straps are reefed around the outer style of the lower section of the ladder (using the loop in one end of the strap) at a position closest to the J hooks. This means that the strap will be as short as possible when attached to the hooks. Straps may be left on the ladder during the working day. The straps are attached to the J hooks by means of the strap hooks. Slack is taken out of the strap by pulling excess through the ratchet. The straps are then put into tension via the ratchet device. The system is now ready for use by the operative. For further safety the operative can utilise a harness, non shock absorbing lanyard and karabiner thus providing a work positioning system at the desired height. If hook positions dictate that the ladder must be positioned directly above a single hook then both straps can be linked back to the same hook and the system used as normal. To release the system simply pull the spring loaded clip mounted on the ratchet device and pull through the webbing. The diagram shows the recommended height for ladder restraints to be installed (1.8m). The black solid ladder drawing shows the initial position and the two red drawings indicate the next ladder positions all utilising just two ladder restraint J hooks installed at 2-4m centres. It is generally recommended that the ladder should be utilised at 75º. LADDER RESTRAINT RATCHET AND STRAPS - LR 003-(3m)/LR 006-(6m) Ladder Restraint Straps Nylon Strap manufactured to BS 5759 : 1987. Straps complete with snap hook and ratchet Material : Nylon Strap rated assembly strength 0.25 tonnes. Minimum breaking strength 0.5 tonnes. Net weight : Nylon Strap 0.21kg. Ratchet Strap 0.42kg. LADDER RESTRAINT HOOK - LR 001 Material : 316 Grade stainless steel J hook. Net weight : 0.1kg. LADDER POSITION 50mm 75mm RACHET LADDER STRAP FIXED TO LADDER Ø12mm MAINTENANCE Every time the system is used a visual inspection of the straps must be carried out by a competent person to check for wear and abrasion. The J hook and surrounding structure should also be inspected for general deterioration by a competent person. There is no legal obligation to pull test the ladder restraint J hooks. 1.8m 4 1 LADDER RESTRAINT HOOK SPACING CAN VARY (2-4m) GENERALLY LADDER ANGLE CAN VARY

Anchorage Systems Recertification Although there is no legal obligation to recertify ladder restraints, there is a general requirement under Regulation 5 of the Workplace (Health, Safety and Welfare) Regulations to inspect and record the general condition of the restraint system in order to provide a maintenance schedule that is available for inspection. Check the system & configuration still serves the client s needs. Establish if any modifications, additional products are required to reflect any refurbishment or additional plant and equipment that has been installed and requires access. It is recommended that each ladder restraint and its structure should be examined at least once every 12 months by a competent person. Each structural anchor, after being examined should be submitted to an axial pull-out force of 2.5 kn to confirm the soundness of the fixing. The structural anchor should sustain the force for a minimum of 15 seconds without deformation. Structural anchors that fail the test should be rejected. After testing, the structural fabric should be carefully examined for cracking or other signs of failure, and appropriate action taken if necessary. Should the structure fail, the hole should be plugged so preventing re-use and the device relocated in a sound structure. Ladder restraints in buildings which have been subject to fire and high temperature, impact damage or any similar detriment should be renewed. Check system plaque position & mark up to reflect date of the next required inspection. Establish if additional plaques are required due to any refurbishment works.

Personal Fall Protection Systems PERSONAL FALL PROTECTION SYSTEMS Personal fall protection systems are required when an operative is working at an elevated level with an unprotected side or edge, which can be at any height. The system must be designed in such a way to prevent the operative from free falling more than 2m or striking a lower level. There are two ways that a company can accomplish this task: Fall Restraint or Fall Arrest. FALL RESTRAINT SYSTEM This system does exactly what it states. It is designed in such a way as to restrain the user from falling by not allowing the user to get to the leading edge. With this system the free fall distance is ZERO. Belts can be used with this type of system but a full body harness is recommended. If any possibility of a free fall exists then the user needs to use a Fall Arrest system. FALL ARREST SYSTEM A fall arrest system consists of the following components: Anchor, Connector, Body support and Retrieval. Anchors need to have a minimum breaking strength of 10kN or be engineered for a specific system and have a safety factor of 2:1. Connectors can consist of one of several different means. A positioning lanyard, a deceleration lanyard, a self-retracting lanyard/life line or a climbing aid device. Body support is a full body harness. A full body harness distributes the fall impact throughout the body and allows the user to better absorb a fall. When working in a fall arrest situation it is a legal requirement for the employer/building owner to have a rescue policy and plan in place and not to rely solely on the emergency services. Anyone responsible for or working at height must be trained fully on correct rescue procedures including how to use the rescue kit provided. Should an emergency occur, a competent first aider should be present to assist with the casualty and to follow the standard UK first aid guidance for the recovery of a person. KEY COMPONENTS OF A FALL ARREST SYSTEM There are a number of issues that need to be addressed when considering using a fall arrest system. IMPACT FORCE The maximum impact force for a full body harness is 6kN and 10kN for the anchorage point. Calculating the impact force is difficult because there are so many variables. These variables include fall distance, person s weight, and attachment method (self retracting life line, shock-absorbing lanyards, etc.). EQUIPMENT COMPATIBILITY It is important that the equipment being used is compatible with one another. The entire system needs to be measured by its weakest link. Conventional locking snap hooks need to be used with compatible D-ring connectors. It is a general recommendation that a user does not mix fall protection equipment from various manufacturers in order to avoid a compatibility issue and to ensure maximum manufacturer guarantee of quality and use. FREE FALL DISTANCE In layman s terms, it is the distance that a person falls before any part of the system starts to arrest the fall. Free fall is measured from the anchorage point to the point in which the system started to arrest the fall. This distance excludes deceleration distance and lanyard/harness elongation. Maximum free fall distance is 2m or striking a lower level. TOTAL FALL DISTANCE Is measured as the distance the operative fell from the point at which they were standing to the position of their feet after the fall. Free fall and deceleration distances are included in the measure. An example of the 6m rule which shows falling distances can be seen in the diagram. ANCHORAGE POINTS Need to be rated at a minimum of 10kN per person. If engineered, they need to have a 2:1 safety factor. Consideration of fall protection system & PPE should include: 1m - system deflection 2m - height of person 2m - shock absorbing lanyard up to 1.75m - absorber extension In this instance, a minimum distance for fall arrest of 6.75m will be required. Limitations and dangers of using a restraint system on a sloping roof Fall restraint system unsuitable for this roof arrangement

Minimum Height Requirements Diagram A Anchor point above user. (In this case 1m above user s harness attachment point) (Preferred Option) Free fall distance: 0.5m Fall factor = 0.5/1.5 = 0.3 Diagram B Anchor point at shoulder level. (Non-preferred option) Free fall distance: 1.5m Fall factor = 1.5/1.5 = 1.0 Diagram C Anchor point at foot level. (To be avoided) Free fall distance: 3.0m Fall factor = 3.0/1.5 = 2.0 NOTE: The lower human figure in each diagram indicates the position of the user at the end of the free fall. This is the point at which the energy absorber begins to deploy and should not be confused with the position the user would be in at the end of the arrest of the fall. KEY F = Free fall distance (Source BS 8437:2005) The above diagram shows three fall arrest situations. In each case the fall arrest system is based on a 1.5m long energy absorbing lanyard and a distance between the attachment point on the user s harness and their feet of 1.5m. The free fall distance is the vertical distance between the position of the user s feet immediately before the fall, and the position of the user s feet at the point at which the lanyard has become taut and started to arrest the fall. (Figure F in the diagram)

Work at Height Rescue Before commencing any work at height activity please ensure you are adequately trained and competent to carry out the task and able to use the safety equipment provided by your employer/building owner. In situations where a work at height activity involves a fall arrest situation, it is a legal requirement for your employer/building owner to provide the anchorage point, rescue plan, policy, training and equipment to complete a rescue. It is not the responsibility of the emergency services to conduct such a rescue. Should a rescue become necessary it is extremely important that the procedures detailed in the roof permit to work, rescue policy and plan are followed. Try to make contact with the casualty to establish if they are conscious or unconscious. If they are unconscious then time is of the essence. Contact the emergency services and request an ambulance and fire/rescue support. Inform them of the exact address, location and site contact details of where you are working (This should be contained within the permit to work ). Confirm that you are trained and competent to commence the rescue procedure. Call your site contact and inform them of the situation and that you have already contacted the emergency services. Request they bring a competent First Aider to assist you at ground level by receiving the casualty. Webbing/Rope Sling Kernmantel Rope Screw Gate Karabiner (EN341 & EN1496) Safesite Rescue Hub Edge Protector Rope Grab (EN353-2) Before commencing the actual rescue, ensure that you are safely connected to an alternative suitable anchorage point (where possible). Ensure you work in fall restraint at all times whilst conducting the rescue procedure. Check you have all the Rescue Kit components as shown in the diagram above.

Rescue Kit Operation a. Connecting to the same or an alternative suitable anchorage point. Connect the Safesite Rescue Hub device using the Screw Gate Karabiner fitted directly to the Safesite Rescue Hub. Ensure the Screw Gate is tightened once connected to the anchorage point. b. Pull the end of the Kernmantel Rope which has the Rescue Rope Grab attached. The Kernmantel Rope will start to feed out of the rescue bag and run through the Safesite Rescue Hub. c. Start walking towards the area where the casualty has fallen whilst still holding the Rescue Rope Grab.When you reach this area, kneel down and continue to pull out sufficient rope to reach the D ring on the casualty s harness. d. Ensure the Edge Protector is connected to the anchorage point, this may need to be extended in some cases via a webbing or rope sling. Place the Edge Protector over the edge ready for the rescue operation.

Rescue Kit Operation e. Whilst holding the Rescue Rope Grab unscrew the Screw Gate as shown above. f. Turn the Rescue Rope Grab over and push the lever in an upwards direction. g.the Rescue Rope Grab will now open. h. Ensure you have adopted a fall restraint position. Carefully lean over the leading edge and pass the open Rescue Rope Grab (with the arrow in the up direction) around the back of the casualty s rope. (cont) i. (cont) Ensure the casualty s rope is correctly positioned inside the Rescue Rope Grab. Close the Rescue Rope Grab. j. Once the Rescue Rope Grab is closed ensure the Screw Gate is then tightened into position. k.position the Safesite Rescue Kernmantel Rope over the Edge Protector. Now carefully lower the Rescue Rope Grab down towards the casualty. The Rescue Rope Grab device will descend easily under gravity to the D ring of the casualty s harness.

Rescue Kit Operation l. Return to the anchorage point where the Safesite Rescue Hub is connected. Pull any excess Kernmantel Rope through the Safesite Rescue Hub by pulling the free end of the rope which is stored in the bag. m. Once the Safesite Rescue Hub Kernmantel Rope is taught, rotate & lower the locking pin so that it engages with the body of the hub. When in place correctly, the hub cannot turn. n. Lift up the black handle as shown above. o. With the black handle in position push in the silver ball bearing positioned in the centre of the white plate as shown above. p. Now open the top third of the Safesite Rescue Hub and it will automatically lock into place. q. Detach the pin.

Rescue Kit Operation r. Start winding the Safesite Rescue Hub in a clockwise direction so that the Kernmantel Rope passes through the hub. If the rope does not move through the hub, pull on the free end of the rope. Continue to wind until the casualty s primary rope becomes slack. s. Once the casualty s primary rope is slack enough to detach their primary hook/karabiner from the anchorage point, stop winding and engage the locking pin by lifting, rotating & then lowering it. Ensure the pin is engaged against the body of the Safesite Rescue Hub. When in place correctly the Hub cannot turn. t. You can now remove the casualty s slack primary rope from the anchorage point as shown above. u. Close the Safesite Rescue Hub by pressing in the silver ball bearing in the centre of the white plate. Once closed fold down the plastic handle.

Rescue Kit Operation v. Pass the loose end of the Kernmantel Rope around the pig tail of the Safesite Rescue Hub. Hold the rope firmly in one hand. To take the load off the casualty, simply rotate and pull the Locking Pin upwards and rotate sufficiently so that the pin is disengaged from the Safesite Rescue Hub. Whilst holding the Kernmantel Rope you can move back towards the area where the casualty fell. w. Once you are in a comfortable position and able to hold the casualty with one hand, take the casualty s primary rope which you previously disconnected from the anchorage point. When ready, carefully position yourself so you are able to attach this primary rope to the Safesite Rescue Hub Rope (Kernmantel Rope) as shown above. Ensure that you keep holding the Safesite Rescue Hub Kernmantel Rope at all times. Gradually lower the casualty s primary rope until the hook reaches the casualty s D ring. Ensure you are still holding the Safesite Rescue Hub Kernmantel Rope. You can now let the casualty s primary rope fall to the ground so that it can be used as a guy rope by those at ground level who are ready to assist/receive the casualty. x. Begin to lower the casualty gradually, continually observing them and communicating with both the casualty and those at ground level who are receiving/assisting the casualty. The competent first aider must then follow the standard UK first aid guidance for the recovery of a person. The casualty must then be seen by the ambulance crew, even if they appear to have recovered.