FIRE DOOR CAPABILITY CHART - 20-MINUTE POSITIVE PRESSURE

Similar documents
MACHINING OF VT FIRE RATED DOORS BY OTHERS

Beauty-Line Windows (1957 to 1979)

Opening and closing force guidelines

HARDWARE. Push / Pulls... A Pivots... A Hinges, Locks and Cylinders... A Handles, Locks and Accessories... A4...

Halsey Taylor Owners Manual

P STYLE 6 LH 5 RH 4 LRH

NOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016

CRL COMMERCIAL PATCH HARDWARE WEDGE LOCK STYLE FOR 5/8"-3/4" GLASS TYPICAL HURCULITE WEDGE-LOCK GLASS DOOR ELEVATIONS P STYLE

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.

P STYLE 6 LH 5 RH 4 LRH

CLEANROOM GEL GRID CEILING SYSTEM PRODUCT DATA Division

CERTIFICATE OF APPROVAL No CF 877 ZOO HARDWARE LIMITED

Kestrel Aluminium Systems Limited. Product Manual Section 10 Thermal Framing System. Manual Version

T Y P E V S A B M S E W A G E P U M P

AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A STRUCTURAL PERFORMANCE TEST REPORT SUMMARY RENDERED TO:

SECTION SHOWER AND BATH ENCLOSURES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

P STYLE 6 LH 5 RH 4 LRH

Assembly Instructions for the Rolling Harrow and Reel Turbo-Till 6/26/03

Standard Model Coolers, Freezers and Combination Cooler/Freezers In Stock for SAME DAY SHIPMENT

NO LAKE. Standard Model Coolers, Freezers and Combination Cooler/Freezers In Stock for SAME DAY SHIPMENT

Installation/Care/Use Manual Soft Sides Fountains with FLEXI-GUARD

Halsey Taylor Owners Manual


B Upper Guide & Carbide Block. B Filler Block (Nylon) B004131S. Blade Cleaner. (Steel)

Tower Accessories & Hardware

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

SHMS. Downstream Beamline. Large SHMS/HMS Angles (Config-1) Large SHMS / Min HMS Angle (Config-2) Dan Young Ext /26/2015 1

FEATURES. Welded Sash and Main Frame. Swiggle or DuraSeal Spacer System on Fixed Units. 3-1/4" Frame Depth. True Sloped Sill. Integral J Channel

PNEUMATIC CONNECTORS SELECTION

Invacare Top End Parts Catalog

INSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008

TYPE 3710 CARTRIDGE SPLIT SEAL Technical Specification

NOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016

ADA COMPLIANCE CHECKLIST (RESTAURANT) Meet Fail N/A. Parking Lot

A F LCON PANEL PRODUCTS LTD

GP100 SERIES ENDURANCE PLAYGROUND SYSTEMS. Installation and Assembly Instructions. Gared Holdings, LLC 9200 E. 146th St. Noblesville, IN 46060

F13.11 PARALLEL HINGES F13 PROJECT-OUT WINDOWS AND TOP HUNG WINDOWS

CERTIFICATE OF COMPLIANCE

500 SERIES. Standard-Duty Grade 3 Surface Applied Closers. Standard Features. 3 hours fire rated. door openings. closing speeds

D100/D200. Deadbolt service manual

S110 Steel Level Panel Installation Instructions

D. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER

Salice 4100 Tower Bolt

Rev J Terminator Parts Book Page 1 of 15 Top End

CONCEALED DOOR CLOSERS

Introduction. P r otective Seals Panel seal for One Hole Mounting (OHM) O-Ring seals for panel mounting Switch boots

Assembly Instructions for the Rolling Harrow and Board Turbo-Till 6/26/03

Superstrut. Metal Framing. Surface Raceway and Lighting Systems. Material. Design Data. Electrical Raceway

hockey hockey Integral Weighted Goals Aluminium Goals Fence Folding Goals Premier Hockey Goals Folding Wheelaway Goals

WELL COMPLETION & PROTECTION. www. .com MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD

CERTIFICATE OF APPROVAL No CF 111 ALLEGION (UK) LIMITED

Plans and Instructions to build a folding reflector oven

3190A NEO-ANGLE DOOR INSTALLATION INSTRUCTIONS. Series MODEL NO

1. Section Summary for loose climbing equipment provided by Owner. 2. Section "Cast in Place Concrete"

Advantage Lockers & Bike

Owners Manual. Models 4420BF1U & 4420BF1L Floor Mounted Bi-Level Bottle Filler Tubular Fountain

Test Report. Test Report Smart Systems Limited Incorporating Smart Extrusions. Page 1 of 78

Halsey Taylor Owners Manual

XCE: Explosionproof Control Enclosures

SIF Exploded Views 10/3/2016

Superstrut. Metal Framing. Surface Raceway and Lighting Systems

Taking Your Own Track Measurements

HLS 9000 Swing Door Handle Edition 4

Installation Guide RHT-380. This Manual Must Be Read Before Operating The Equipment CUSTOMER COPY

Building Code Guidelines for Residential Pools

CERTIFICATE OF APPROVAL No CF 877 ZOO HARDWARE LTD

K13.12 FACE FIXED PANIC EXIT DEVICE K13 DOORS

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.

GEN20AD-GEN20AL-GEN18AN

Important Information

Take a closer look at; Parts - Equipment Systems

5. STRUCTURAL ANALYSIS

M ARTI N S TR8 FEEDER 508T BEEF-RITE FEEDER WBF 36" BUNK FEEDER NEED!

We can make custom parts that work with many top office furniture manufacturers such as:

Product: Aluminium Door Edge Guard

Bike-Shell Model 301P

Table of Contents Auxiliary Locks

ORNAMENTAL CANTILEVER GATE INSTRUCTIONS

THE ARENA TABLE OF CONTENTS 6 THE ARENA OVERVIEW Dimensions and Tolerances... 2

For optimum sealing apply strips of NOR 710 seal over hinge blades with 710 seal blades to align with 720 seal blades. NOR 710 NOR 720 NOR 855

DEADBOLT SETS, MECHANICAL FEATURES

Product: Aluminium Door Edge Guard

Rev S Terminator Parts Book Page 1 of 14 Top E nd

Universal Elevator Mount Owners Manual Customer Service Center N53 W24700 South Corporate Circle Sussex, WI U.S.A.

RZR 900 Hitch Mount Plate

REPAIR PART NUMBER NUMBER DESCRIPTION 0137 ELE 0136 ELE 12 VOLT SOLENOID

TOWN OF AURORA. Pool Enclosure Permit Guide. PLANNING AND BUILDING SERVICES Building Division

HEAVY DUTY PNEUMATIC

Avenger Model 33M Installation & Operation Instructions

Channel Bracket Support Cable Bracket Bearer Locking Pin Foundation Bolt Iron Anchor Step Manhole Sump Grill PVC/Steel Ladder Ladder Support & Hook

This parts list is current as of the above revision date. See for the current revision.

Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS

PARTS FAX

TBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE. For technical questions, please contact the following:

Check with local zoning official for property line distance requirements.

! CAUTION! ! WARNING! General Information

BUILDERS HARDWARE SECTION 6 INDEX

To address this issue, Ariens Company has developed two cradle plates kits:

EZ SERIES FIXED ACCESS LADDERS

REVIEW ALL INSTALLATION NOTES PRIOR TO INSTALLATION!

Transcription:

FIRE DOOR CAPABILITY CHART - 20-MINUTE POSITIVE PRESSURE Fire Rating 5-Ply Wood HPDL Do Only Do w/ Transom 1 5509 909 5P09 9P09 over up to 5502 303 404 over up to 5P09 9P09 5P09 9P09 3-0 5508 5P08 8 8P08 3-0 over up to 5P08 8P08 5P08 8P08 3-0 Ma. Size Std. Pair 3-4- Ma. Size DE Pair 3-4- N/A N/A N/A N/A, 3-,, 3-,, 3-,, 3-, Ma. Transom Maimum Lite 2 Maimum Louver 3 (fusible link) Size W L Sq. W L Sq. Hinges Pivots N/A N/A N/A N/A N/A N/A, 3-,, 3-, N/A N/A Locks (ma. 5" Dead (ma. 5" Dead (ma. 5" Dead (ma. 5" Dead (ma. 5" Dead (ma. 5" Dead (ma. 5" Dead (ma. 5" Dead (ma. 5" Dead Fire Eit Devices 4 Closers Viewer 2 per do ma. Flush Bolts Auto Do Bottoms 1" Dia. N/A d, Semimtised 1" Dia. N/A d, Semimtised 1" Dia. Listed 24" ma. 1" Dia. Listed 24" ma. 1" Dia. Listed 24" ma. 1" Dia. Listed 24" ma. d, Semimtised d, Semimtised d, Semimtised d, Semimtised 1" Dia. N/A d, Semimtised 1" Dia. Listed 24" ma. d, Semimtised 1" Dia. N/A d, Semimtised Kick Plates Ma. Ma. Ma. Ma. Ma. Ma. Ma. Ma. Ma.

Lead Lined Lead Lined 5507 5P07 707 7P07 over up to 5P07 7P07 5P07 7P07 3-0 5515 1515 5P15 1P15 N/A N/A, 3-,, 3-, N/A N/A N/A N/A N/A N/A 16" 16" 256 N/A N/A N/A Per N/A N/A N/A 16" 16" 256 N/A N/A N/A Per (ma. 5" Dead (ma. 5" Dead (ma. 5" Dead (ma. 5" Dead (ma. 5" Dead 1" Dia. N/A d, Semimtised 1" Dia. Listed 24" ma. 1" Dia. Listed 24" ma. 1" Dia. Listed 24" ma. 1" Dia. Listed 24" ma. d, Semimtised d, Semimtised d, Semimtised d, Semimtised Ma. Ma. Ma. Ma. Ma. 1 Requires fied bar between do and transom. 2 Larger lite sizes may be available using special glass frame. 3 Louvers are not available in 20-minute dos per. 4 5 legged metal channels required with CVR.

How to Specify Categy A Installations "Where UBC 7-2-1997 requirements f positive pressure must be met, dos shall include all requirements as part of the do construction per Categy A guidelines as published by ITS/Warnock Hersey. No intumescent is allowed on the frame. Only smoke gasketing applied around the perimeter of the frame to meet the S rating is permissible. POSITIVE PRESSURE FIRE DOOR INSTALLATION INSTRUCTIONS F Dos That Have Been Labeled in Compliance with UBC 7-2-1997 VT positive pressure fire dos are constructed to meet Intertek/Warnock Hersey Categy A guidelines, allowing dos to be hung without any surfaceapplied intumescent. Our positive pressure fire dos arrive ready-to-hang, just like all other VT dos. The VT label is your assurance f one-step installation. 1. In der to meet the smoke requirement, a smoke seal, listed and labeled f UBC 7-2-1997 Parts 1 and 2 positive pressure installations, must be mounted around the perimeter of the frame. 2. Astragal sets, metal edges, edge guards taller than 40 AFF require surface-applied intumescent furnished and installed by others. Refer to manufacturer s instructions f intumescent application. Edge guards installed below 40 AFF and 5 metal channels do not require surfaceapplied intumescent. Flat bar astragals (FBAs) are allowed on pairs of dos with fire ratings up to 90-minute with no additional intumescent required. 3. Light Kit [Where applicable] install a lite kit listed and labeled f UBC 7-2-1997 positive pressure applications to meet the appropriate fire rating. (See fire label located on do f fire rating.) Follow lite kit manufacturer s instructions f proper installation. 4. Dos must be installed in fire-rated frames. Standard 3-sided steel frames (minimum 16-gauge) do not require special fire testing f positive pressure. s must be installed plumb, square and level. 5. Hardware Dos have been facty-prepared to receive hardware as indicated by the hardware supplier s schedule. Hardware may be required to be listed and labeled in accdance with UBC 7-2-1997 and UL 10C-1998 f use in positive pressure fire-rated wood dos if located above 40" AFF. Anything below 40" AFF can follow eisting standards. 6. Clearances The clearances between the do edge and frame must be at least 1/16 inch and no greater than 1/8 inch at the head and jambs. See, latest edition, f clearance under bottom of dos. Rev 06/07

FIRE DOOR CAPABILITY CHART 45-, 60- and 90-MINUTE POSITIVE PRESSURE Fire Rating 45-, 60-, 90- Minute Mineral 60-Minute 60-Minute Mineral Mineral 5-Ply Wood HPDL Do Only Do w/ Transom 1 5P11 1P11 5P09 9P09 3-0 5P45 1P45 5P09 9P09 5P45 1P45 5P08 8P08 3-0 Ma. Size Std. Pair 2-, 3-4- Ma. Size DE Pair 2-, 3-4- Ma. Transom Maimum Lite 2,6 Maimum Louver 3 (fusible link) Size W L Sq. W L Sq. Hinges Pivots 10" 33" 100 24" 24" 576 Per N/A N/A N/A N/A 10 33 N/A N/A N/A N/A Per N/A N/A N/A N/A 10" 33" 100 24" 24" 576 Per N/A N/A N/A 24 24 54 36 1296 4,5 864 4 N/A N/A N/A Per N/A 36" 54" 1296 24" 24" 576 Per N/A N/A N/A N/A 24" 36" 864 24" 24" 576 Per Locks (ma. 5" Dead (ma. 5" Dead (ma. 5" Dead (ma. 5" Dead (ma. 5" Dead (ma. 5" Dead Fire Eit Devices Closers Viewer 2 per do ma. Flush Bolts 1" Dia. Listed 24" ma. Auto Do Bottoms d, Semimtised 1" Dia. N/A d, Semimtised 1" Dia. N/A d, Semimtised 1" Dia. Listed 24" ma. 1" Dia. Listed 24" ma. d, Semimtised d, Semimtised 1" Dia. N/A d, Semimtised Kick Plates Ma. Ma. Ma. Ma. Ma. Ma. 1 Requires fied bar between do and transom. 2 Larger lite sizes may be available using special glass frame. 3 Louvers are not available in 20-minute dos per. 4 Requires metal vision panel. 5 Cut out lined with intumescent. 6 FT1FP mouldings - 100 square inch lite maimum.

How to Specify Categy A Installations "Where UBC 7-2-1997 requirements f positive pressure must be met, dos shall include all requirements as part of the do construction per Categy A guidelines as published by ITS/Warnock Hersey. No intumescent is allowed on the frame. Only smoke gasketing applied around the perimeter of the frame to meet the S rating is permissible. POSITIVE PRESSURE FIRE DOOR INSTALLATION INSTRUCTIONS F Dos That Have Been Labeled in Compliance with UBC 7-2-1997 VT positive pressure fire dos are constructed to meet Intertek/Warnock Hersey Categy A guidelines, allowing dos to be hung without any surfaceapplied intumescent. Our positive pressure fire dos arrive ready-to-hang, just like all other VT dos. The VT label is your assurance f one-step installation. 1. In der to meet the smoke requirement, a smoke seal, listed and labeled f UBC 7-2-1997 Parts 1 and 2 positive pressure installations, must be mounted around the perimeter of the frame. 2. Astragal sets, metal edges, edge guards taller than 40 AFF require surface-applied intumescent furnished and installed by others. Refer to manufacturer s instructions f intumescent application. Edge guards installed below 40 AFF and 5 metal channels do not require surfaceapplied intumescent. Flat bar astragals (FBAs) are allowed on pairs of dos with fire ratings up to 90-minute with no additional intumescent required. 3. Light Kit [Where applicable] install a lite kit listed and labeled f UBC 7-2-1997 positive pressure applications to meet the appropriate fire rating. (See fire label located on do f fire rating.) Follow lite kit manufacturer s instructions f proper installation. 4. Dos must be installed in fire-rated frames. Standard 3-sided steel frames (minimum 16-gauge) do not require special fire testing f positive pressure. s must be installed plumb, square and level. 5. Hardware Dos have been facty-prepared to receive hardware as indicated by the hardware supplier s schedule. Hardware may be required to be listed and labeled in accdance with UBC 7-2-1997 and UL 10C-1998 f use in positive pressure fire-rated wood dos if located above 40" AFF. Anything below 40" AFF can follow eisting standards. 6. Clearances The clearances between the do edge and frame must be at least 1/16 inch and no greater than 1/8 inch at the head and jambs. See, latest edition, f clearance under bottom of dos. Rev 07/08