EFLOW GUIDE. IRRIGATE UP TO 200m 2 SUITS DOMESTIC ONSITE APPLICATIONS

Similar documents
Pressure Compensating (PC) Spray Stakes

How Do I Install My Garden Master Bucket Garden?

Putting it All Together: Making Sense of Drip Irrigation UC Master Gardener Conference August 24, 2017

Agricultural Water: Part 2

Golf Drip System. Subsurface Irrigation System for Golf Course Applications D L S E R I E S. Features

Drip TAPE. Maximum Length of Run for 90% Uniformity 0% Slope. *For other slopes and uniformity co-efficients, use our calculator on

175 m2 (1,880 sq ft) Kit

Overhead Irrigation Installation Guide DOM Copyright First Tunnels Ltd 2012.

Vessel Installation and Operating Manual

Underground irrigation

TECHLINE HCVXR AND CV DESIGN GUIDE DRIPLINE FOR SUBSURFACE AND ON-SURFACE

Installation and Operating Manual

Basic layout 2016 IRRIGATION-MART. Check (Non- Leak) Valve. Friction Fit. Sprinkler. Figure 1 - Hanging Sprinkler & Check Valve Assembly

Appendix B Harris County Standard Operating Procedure for Determining In Situ Hydraulic Performance of High Flow Rate Bioretention Media

User's Manual. MixRite TF 10. Edition 05.08

Combination Air Valve

Pure Water Power Purification System 4-Stage RODI Operations Manual

"QM" DESIGNER'S GUIDE AMERICAN "PERC-RITE " SECONDARY TREATED DRIP SYSTEMS 1 ZONE or 2 ZONE -- SIMPLEX PATENT NO. 5,200,065 & 5,984,574B

Blue Points 1 ¼ WELL POINT INSTALLATION INSTRUCTIONS

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

Combination Air Valve Model

ACCESSORIES PRODUCT CATALOG

Installation Guide For Spillways & LED Light Bars

HOW TO PLAN AN UNDERGROUND IRRIGATION SYSTEM

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

10 DRIP NOZZLE WATERING DRIP KIT Model / Model 46095

Aquor House Hydrant V2

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

AIR GAP (AG) Low Hazard High Hazard

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

NQF Level: 4 US No:

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

Macro-Infusion Guide

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Halsey Taylor Owners Manual STOP!

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

VAC-U DRIVE Swinging float arm for Acrobat like agility 36 Fin disk with DEEP VEE Scoop

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6

Rain Barrels. Did You Know?

Installation of Your SprayMaster System

Easy Nest Kits. Installation Suggestions

WORKHOLDING APPLICATION BOOKLET

PVC Push Fit System. No glue. No wait. Just push and go.

Installation Manual. Model # SF-3W 9/16/03 REV 1. Arch Chemicals, Inc Lower River Road. P.O. Box 800 Charleston, TN PULSAR

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

Assembling & Installing your Pool Cleaner

Valves. Controllers. Valves Two Types

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

UsER manual for Watersens ph -REDOX

BS Series Basket Strainer

EUROFLO CULVERT PIPE. Fittings / Pipes

Model: 43T. Bermad Pressure Relief Valve

MICROMOUND DESIGNERS GUIDE

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL

Gas and Vacuum Tubing Connection Kit for Manual Operation, No

CARTRIDGE FILTERS TECHNICAL MANUAL MT 080. Installation, commissioning and maintenance instructions. 08/02 Edition

MITIGATING PIPE AND RISER HYDRAULIC PIPELINE ISSUES WITH THE I-RISER PLUS

Bermad Model:

COMPRESSED AIR DISTRIBUTION SYSTEMS

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

Lab Cock. Contents. User s Manual (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Pressure Dump Valve Service Kit for Series 2300 Units

DESIGN AND PRE - INSTALLATION INFORMATION

Installation of Nylon Putting NP50

OPERATION MANUAL obl1 OPERATION MANUAL

CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

-FRU FREEZE RESISTANT WATER VALVE COOLERS SYSTEM

PRO SINK -R 1 and 2. Dilution system CONTENTS

W A S T E W A T E R T R E A T M E N T S Y S T E M S

Siting and Installation Manual

INTRODUCTION... 3 II II II II II II II II II II II II II I 4-5 ASSEMBLY... 6,7,8 II II II II II II II... 9

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

MAKE YOUR SAMPLE COUNT! A PRIMER ON COLLECTING QUALITY, REPRESENTATIVE SAMPLES

TECHNICAL DATA. Trimpac 244a. September 16, 2013

INSTALLATION INSTRUCTIONS

Installation Instructions

SIMPLAIR PIPING TOOL. JXT Company

Hot Compressed Air Lance Operation Manual. LAB Manufacturing 9483 Reading Road Cincinnati, OH (800)

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

Pressure Dump Valve Service Kit for Series 3000 Units

INSTRUCTION MANUAL & PARTS

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

Suction Sampler. Purpose of this document

ACCU-PULSE Installation and Operation Instructions

Bar valve with fixed shower head Installation guide

Chlorine Supply Containers And Piping

AUTOMATIC HOSE TEST UNIT, TYPE SPU

553 Series.

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS

Transcription:

EFLOW GUIDE IRRIGATE UP TO 200m 2 SUITS DOMESTIC ONSITE APPLICATIONS

> eflow : Water Reuse Dispersal System eflow is a complete dripperline diversion package specifically developed For onsite domestic and treated greywater dispersal systems. created by netafim - the World leader in drip irrigation - this complete package allows the reuse of domestic household Water to irrigate garden and turf areas. How eflow works Netafim s eflow dripperline system delivers a slow and precise application of treated effluent evenly throughout the soil. Made of flexible polyethylene tubing, the dripperline has evenly spaced pre-inserted emitters. When water is pumped through the dripperline, these pressure compensating emitters discharge an even, slow distribution of treated effluent into the ground. The eflow advantage > The highest water efficiency compared to other systems > Allows reuse of water for supplementary turf and garden irrigation > Reduces offensive odours, aerosol drifting and buffer zones > guaranteed uniform distribution over entire application area > Low application rate improves water infiltration for all soil types > drippers are specifically designed to operate without clogging > Minimal maintenance and service requirements > Automated system reduces human interaction eflow is the only product with pressure compensating drippers that hold water within the dripperline during system shut-down. This improves distribution and reduces wasted run-off on slopes. it also has a clever System Protection unit with a life-time guarantee against root intrusion for turf applications. Plus, eflow dripperline has the largest filtration surface area than any other system on the market. Installation The eflow system is flexible enough to be used across garden and turfed areas of all shapes, sizes and undulations. it s a comprehensive, easy-to-use package that has all you need to get your eflow system up and running in no time. Your eflow kit includes: - 200m unibioline CNL dripperline.6l/hr @ 0.40m spacings - 50m Purple LdPe - Arkal disc Filter - Techfilter dripperline - Valve Boxes - Plus all ancillary equipment such as Fittings, Air Valves and Flush Manifolds starter kit add-on kit

Surface installation techniques Surface installations apply the same principles as sub-surface installations except they are not buried. Surface installations are installed in garden beds on top of the soil and below the mulch layer. it is recommended that stakes are used during backfilling to stabilise the dripperline header assembly and Flush Manifold. Sub-surface Dripperline installation techniques There are a number of techniques you can use when installing the dripperline below the surface. Trenching This is the most common technique. This involves digging a trench no wider than 50mm to the depth required. it is important when backfilling not to damage the pipe with sharp rocks and objects. The narrower the trench the better. This ensures water will move laterally rather than down the trench. Ripping using a ripping attachment is the fastest and most successful way of installing a dripperline. if the soil is dry and hard, then wet the area before ripping. Be careful not to stretch or damage the outside wall of the dripperline during installation. Vibratory Plough The vibratory plough is more suitable for larger sites with longer run lengths. it works well with difficult compact soil types, however wetting the soil before installation may still be required. These machines are capable of ripping more than one line at a time. On surface backfilling This method is particularly useful in new sites where topsoil will be added afterwards. The whole system is laid out on top of the sub-grade, then backfilling of soil over the top of the dripperlines takes place. it is very important not to damage the dripperline with any heavy machinery during backfilling. Which ever form of installation you choose, we recommend you install Air Valves, Manual Flush Valves and Filters to ensure the longevity of the system.

> Assembly Filter Assembly The Arkal disc Filter is used to protect the system from contamination of debris. it has a 30 micron element inside that requires cleaning periodically (see maintenance and servicing). The Techfilter is also required to provide the system with trace elements of Trifluralin. This chemical prevents roots from blocking drippers.. Assuming the outlet of the treatment plant is a male thread, use a ratchet clamp to connect the LdPe to the treatment plant with the Nut & Tail fitting. 2. using the ratchet clamp again, connect the Arkal disc Filter (black) to the LdPe with Nut & Tail fittings. 3. Now use the ratchet clamp to connect the Techfilter (black) to LdPe using Nut & Tail fittings. Important: - The arrow on the filter indicates the direction of flow - Filters should be installed facing down as shown in illustration - The Arkal Disc Filter is to be installed upstream of Techfilter - If installing multiple zones, tee s are to be installed after the filtration system (Tee s are provided in the Add-on kit only). - The filter system is to be contained within the rectangular valve box provided. This valve box has cut outs for inserting LDPE either side of filters. Valve boxes require a stable base and a gravel sump to ensure they don t fill with water when it rains. - Only insert the Techfilter cartridge once the system has been installed. Follow the handling procedures shown on the instructions inside the box. - If indexing or controllers are required please consult your Netafim distributor. Zone Assembly using the LdPe from the Filter Assembly, you need to create a header assembly that runs perpendicular to the dripperline. This will be buried below the surface in Sub-surface dripperline installations between 00mm and 200mm.. Attach the end Connectors to the end of the header assembly using a ratchet clamp. 2. using the punch tool, insert holes into the LPde at lateral spacings. With the 7mm ratchet clamp, attach the dripperline into the Start Connectors and insert the fitting into the hole on the LdPe. ensure the fitting and initial section of dripperline remains perpendicular to the LdPe. 3. using LdPe, install the Flush Manifold opposite the header assembly. 4. Repeat the installation of Start Connectors between the dripperline and LdPe for the Flush Manifold. 5. insert the end Connectors at the highest end of the Flush Manifold using a ratchet clamp. Flush Valve The Flush Valve is used to clear any debris out of the system during routine maintenance. The Flush Valve is located at the lowest end of the Flush Manifold.. Screw the threaded elbow into the male Manual Flush Valve. Be sure to apply thread tape (thread tape not provided). 2. Connect the threaded elbow to the LdPe Flush Manifold using a ratchet clamp. 3. install the Manual Flush Valve at 90 to the surface, ensuring the lilac cap is level with the finish grade of the soil.

Air Vacuum Valve This component is designed to release air from inside the dripperline during system start-up and shut-down. This reduces the potential risk of soil being sucked into the drippers and causing clogging.. Locate the highest point of the system along either the header assembly or Flush Manifold. 2. using a ratchet clamp, insert the female tee into the LdPe. 3. insert the 3mm Air Release Valve into the female tee. do this by applying thread tape and ensure the valve is positioned vertically. 4. install the 50mm round valve box around the air valve, then use the punch outs to insert the LdPe. Completing Installation Your eflow system is now almost complete and ready for operation. To begin using the system, run the following checks: Check The cartridges in both the disc filter and Techfilter are installed. Check 2 When turning on the system for the first time check for leaks being careful not to alow any debris into the dripperline Check 3 Flush the system by opening the flush valve cap then inserting and turning the flush valve key. Maintenance and servicing Regular maintenance and servicing should be carried out periodically. The following parts require on-going servicing to ensure the longevity of your eflow system. Arkal Disc Filter Remove the disc element from the housing and rinse in water to clean any debris on and in between the discs on a regular basis. Techfilter Remove the disc element from the housing and rinse in water to clean all debris on and in between the discs. Important - Replace the cartridge every 2 years. This will ensure continuous prevention against root intrusion. Using the safety instructions provided with the cartridge, make sure all procedures are adhered to during handling. Air Valve While the system is in operation, check the Air Valve by pushing it downwards to flush out any potential debris. ensure the Air Release Valve Box is clean and not buried in soil. Manual Flush Valve during system operation attach the male QCV (Quick Coupling Valve) to the female connection in the ground. This requires lifting the lilac cap, pushing the male connection and turning it to secure. use a short piece of clear hose (not provided) at the end of the male connection to monitor the quality of water within the system as it is flushed. Make sure the system is flushed for a minimum of 30 seconds or longer if possible. Dripperline Regularly check the dripperline for leaking and ponding around the site. if any leaks are found, use a 7mm ratchet clamp to attached dripperline joiners. This will prevent debris or soil contamination occurring.

> Contents ITEM DESCRIPTION STARTER ADD-ON ITEM DESCRIPTION unibioline CNL.6l/hr @ 0.4m spacing 200m 200m Straight take-off LdPe lilac 50m 50m Budget Punch tool STARTER ADD-ON 30 30 super Arkal disc filter, 20 mesh 7mm ratchet clamp 40 40 short Techfilter 7mm joiner 5 5 x FBSP x nut and tail 5 LDPE tee ratchet clamp 6 5 x ¾ FBSP threaded elbow LdPe joiner 2 2 20mm QCV lilac lid LDPE End Plug 2 2 Plastic quick coupling key 3mm MBSP Bermad vacuum breaker 50mm round valve box- lilac lid Rectangular commercial valve box- lilac lid x ½ FBSP threaded tee

> Application SOIL TEXTURE SOIL STRUCTURE DISPERSAL RATE mm/week DISPERSAL RATE mm/week AREA REQUIRED L/day DRIPLINE LENGTH per L 0.5 m spacing.0 m spacing Gravel/Sand Structureless Massive 35 5 0.200m 2 0.400m 0.200m Sandy Loams Loams Clay Loams Massive Highly / Moderately Structured or Massive Highly / Moderately Structured 35 5 0.200m 2 0.400m 0.200m 28 4 0.250m 2 0.500m 0.250m 25 3.5 0.285m 2 0.570m 0.285m Massive Structured Strongly Structured Light Clays Moderately Structured or Massive Strongly Structured 20 2.9 0.345m 2 0.690m 0.345m Medium/Heavy Clays Moderately Structured or Massive 5 2.4 0.467m 2 0.934m 0.467m Regulations and Legislation Each state and council has regulations and by-laws concerning the dispersal of effluent which must be strictly complied with. This manual is intended to be an aid to installers and end users of the eflow Water Reuse Dispersal System and according to local, state or federal law and regulation shall take precedence over this manual. You are accordingly advised and requested to check with your own council and state government as to their specific requirements for the installation of the eflow Water Reuse Dispersal System. Furthermore, the user of the eflow Water Reuse Dispersal System is subject to all local conditions that prevail at the site and further subject to any appropriate expert tests including but not limited to soil tests and water tests, which may be required prior to the installation to determine the fitness for use. In addition, other factors must be considered to determine fitness for use including but not limited to slope and landscape contours and acceptable hydraulic loading rates. Disclaimer The information contained in this manual is intended to act as commentary and general information and is not intended to be advice or contain any representations that should be relied upon by the reader or recipient. The reader or recipient should not rely upon any statement of potential performance, productivity or efficiency as these matters will depend on the individual circumstances of the reader/recipient and the reader/recipient should conduct their own independent investigations and enquiries in respect of these matters. Any technical information is generic and should not be relied on by the reader or recipient. Furthermore, Netafim does not warrant or make any representation regarding the information contained in this manual or the reliability of the information and the reader or recipient should not rely upon any statement or representation made in this manual. The reader or recipient should obtain advice tailored to their particular circumstances and should not rely upon information contained in this manual for any purpose. If the reader or recipient acquires goods or services from Netafim the relationship between Netafim and the reader/recipient will be governed by Netafim s supply terms and conditions. The reader or recipient warrants that this manual is received subject to these conditions and that the reader or recipient will not provide this manual to any person who Netafim has not expressly authorised to receive this manual. If, after obtaining Netafirm s express authority, this manual is provided to any other person by the reader or recipient it shall be provided to that person on the same terms set out in this disclaimer

GROW MORE WITH LESS 8 WWW.NETAFIM.COM.AU WWW.NETAFIM.CO.NZ GROW MORE WITH LESS BR2 EFLOW BROCHURE Brochure Document MARCH 207 Title