COOPER POWER. SERIES VariSTAR type AZE station class surge arresters installation and maintenance instructions. Surge Arresters MN235022EN 0.

Similar documents
Effective January 2017 Supersedes July 2011 (I ) VariSTAR Type AZG4 Surge Arresters Installation and Maintenance Instructions

S Surge Arresters

COOPER POWER. SERIES VariSTAR type composite light-duty under-oil (CLU) MOV arrester installation instructions. Surge Arresters MN235023EN

COOPER POWER SERIES. VariSTAR Storm Trapper high energy MOV arrester installation instructions. Surge Arresters MN235017EN

COOPER POWER SERIES. UltraSIL Polymer-Housed Distribution-Class MOV Surge Arrester Installation Instructions. Surge Arresters MN235006EN

COOPER POWER SERIES. 200 A 15, 25, and 35 KV class insulated standoff bushing installation instructions. Loadbreak Apparatus Connectors MN650039EN

COOPER POWER SERIES. 200 A 15, 25, and 35 kv class portable feedthru installation instructions. Loadbreak Apparatus Connectors MN650037EN

COOPER POWER SERIES. EL Bay-O-Net Current-Limiting Fuse Installation Instructions. Fusing Equipment MN132023EN

COOPER POWER SERIES. D-73P3 bypass switches installation instructions. Switches MN008005EN. Effective April 2016 Supersedes S June 2013

COOPER POWER SERIES. 600 Ampere Deadbreak Grounded Standoff Bushing 15 & 25 kv and 35 kv Class Installation Instructions. Bushings MN650045EN

COOPER POWER SERIES. UltraSIL polymer-housed VariSTAR surge arrester IEC for MV systems to 36 kv installation instructions

COOPER POWER SERIES. Manual or Hostick Operable, Padlockable 150 A Tap-Changer Switch Installation Instructions. Tap-Changer Switch MN800015EN

COOPER POWER SERIES. 600 A 15, 25 and 35 kv class bushing adapter installation instructions. Deadbreak Apparatus Connectors MN650058EN

COOPER POWER SERIES. 600 A 15, 25, and 35 kv class PUSH-OP bushing adapter cap installation instructions. Deadbreak Apparatus Connectors MN650050EN

COOPER POWER SERIES. Under-oil arrester disconnector installation/operation instructions. OEM Equipment MN800010EN

COOPER POWER SERIES. Series winding ratio test procedure instructions. Voltage Regulators MN225060EN. 120 Vac VOLTMETER

COOPER POWER SERIES. QD8 Quik-Drive tap-changer VR or VL reversing switch stationary contact assembly kit number A48 installation instructions

Effective March 2015 Supersedes S August 2002

DT400/436 Tee Connector Installation Instructions

COOPER POWER SERIES. 50 A 2:1 series multiple (dual voltage) switch cap/wrench, lever or hotstick operable handles installation instructions

200 A, 15 and 25 kv class loadbreak bushing insert installation instructions

COOPER POWER SERIES. 200 A 15/25 kv class deadbreak straight connector installation instructions. Deadbreak Apparatus Connectors MN650043EN

S Surge Arresters. Handling and Storage. Standards. Acceptance and Initial Inspection

COOPER POWER SERIES. 200 A 15/25 kv class elbow installation instructions. Deadbreak Apparatus Connectors MN650042EN

COOPER POWER SERIES. DS250 deadbreak straight connector installation instructions interface A. Connectors MN650027EN

COOPER POWER SERIES. DE250 deadbreak elbow connector installation instructions interface A. Screened Separable Connectors MN650025EN

DAI630TB2669 Dead Front Arrester Installation Instruction

COOPER POWER SERIES. 600 A, 15, 25, and 35 kv Class Cleer Grounding Elbow Installation Instructions. Loadbreak Apparatus Connectors MN650056EN

COOPER POWER SERIES. Operation Counter Replacement Instructions. Reclosers MN280047EN. Effective May 2016 Supersedes S December 2003

Effective May 2017 Supersedes July 2009 (S ) 600 A 35 kv Class T-OP II connector assembly installation instructions 200 A PROTECTIVE CAP LRTP

COOPER POWER SERIES. 600 A 35 kv class PUSH-OP deadbreak connector installation instructions. Deadbreak Apparatus Connectors MN650052EN

COOPER POWER SERIES. Types E, 4E, V4E, H, 4H, V4H, L, and V4L single-phase recloser installation and operation instructions. Reclosers MN280051EN

600 A 35 kv class PUSH-OP deadbreak connector installation instructions

COOPER POWER SERIES. 200 A 35 kv class LE series elbow installation instructions. Loadbreak Apparatus Connectors MN650010EN

Installation Instructions for the Walking Beam Interlock for Eaton EHD, FDB, FD, HFD, FDC, FW, HFW, FWC, Circuit Breakers and Molded Case Switches

Medium voltage standard-duty, heavyduty, and extreme-duty single-phase, unfused capacitor units and accessories

DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers

COOPER POWER SERIES. 200 A 15 and 25 kv class elbow with optional integral jacket seal installation instructions. Loadbreak Connectors MN650008EN

COOPER POWER SERIES. VFI SF6-insulated vacuum fault interrupter installation, operation and maintenance instructions. Switchgear MN285004EN

COOPER POWER SERIES. 200 A 15 and 25 kv class elbow with integral jacket seal* for use on tape and wire shielded cable installation instructions

Effective May 2017 Supersedes August 2005 (S )

Permanent Roof Anchors

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

Sub-Base Assembly For Type-ML 32 & VR-1 Step Voltage Regulator Single-Phase Liquid-Filled Part # GEK 35171

INSTRUCTIONS FOR USE

Inspection Recommendations

BS Series Basket Strainer

2000 lb manual winch

Erection, maintenance and disposal Inverted installation. Zinc oxide silicone-housed surge arresters PEXLIM R-X, Q-X and P-X

USER INSTRUCTION MANUAL CONCRETE BOLT ANCHORAGE CONNECTOR

60 farm jack. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

Vertical Lifeline. Ladder Climb. User Instructions. 3M Occupational Health and Environmental Safety. Fall Protection Equipment

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

Norrsken Family Booklet

INSTRUCTIONS FOR USE

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

2-1- Shipping Receiving Lifting Location on Site Installation Stages 6

3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor

S Loadbreak Apparatus Connectors WARNING: WARNING:

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT

DEEPSEA POWER & LIGHT. Operator s Manual. SeaLite Six. Original Instruction Ruffin Road San Diego, CA USA

User Instruction Manual Fixed Beam Anchor

OWNERS MANUAL. Model Shown with optional Primary Mooring Cleats. Portable Mooring System SAFETY OPERATION MAINTENANCE PARTS

GRAVITY BIKE RACK ASSEMBLY & OPERATING INSTRUCTIONS

Operation Manual Enabling Pole-Top Communication Via the TripSaver II Magnet Tool

3M Liqui-Cel EXF-4x13 and 4x28 Series Membrane Contactors

S Vacuum Switches. Contents. Type VCS-1 Single-Phase Vacuum Capacitor Switch Installation and Operation Instructions

OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS

WHEATLEY Series 500 Swing Check Valve

MODELS (2 foot Version) (4 foot Version)

Installation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07

SASK-A-POLE OWNERS AND USERS MANUAL

Instruction Manual. Model TC1-S TopSide Clamp. top side clamp. For your personal safety READ and UNDERSTAND instructions before using tools.

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

Accu-Tab Systems 1000 Series by Axiall Corporation

SPECIFICATIONS ATTENTION

Owner s Manual & Safety Instructions

INSTRUCTIONS FOR USE

Tripod. System. User Instructions. 3M Occupational Health and Environmental Safety. Fall Protection Equipment

This document to be used with Hurley traditional Davits

STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS

Model ASSEMBLY and OPERATING INSTRUCTIONS

Hygienic Bubble Trap Installation and Operations Manual

UE- 90- X X X X X X O P E R AT I N G M A N UA L 0 TO 90 HYDRAULIC UPENDER

RollGliss Rescue Emergency Descent Device. This manual is intended to be used as part of an employee training program as required by OSHA.

GAS FRYER Instruction Manual Model #5099NS

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Installation, Operation and Maintenance Manual for Back Pressure Regulator

3M Liqui-Cel EXF-10x28 Series Membrane Contactor

INSTRUCTIONS FOR MODELS UPH & UPHS HIGH FLOW, HIGH PURITY GAS REGULATORS

Accu-Tab Systems 2000 P Series by Axiall Corporation

foldable/adjustable sawhorse

VOLLEYBALL SPIKE TRAINER. Assembly Instructions. Owner s Manual. Model # VST-400. Club Volleyball Gear

1.3 LIMITATIONS: The following application limitations must be recognized and considered before using this product:

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Mini Pod Press. #78H-M2 Mini Pod Press Manual-R1

BGA244 Binary Gas Analyzer

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

Installation and Service Manual

Transcription:

Surge Arresters MN235022EN Effective November 2016 Supersedes July 2011 (S235-87-1) COOPER POWER SERIES VariSTAR type AZE station class surge arresters installation and maintenance instructions 0.5 0.866 VENT PORT

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation s ( Eaton ) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and descriptions contained herein. The information contained in this manual is subject to change without notice. i

Contents DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY...I SAFETY FOR LIFE...III SAFETY INFORMATION...III Safety instructions...iii PRODUCT INFORMATION.... 1 Introduction...1 Additional information...1 Acceptance and initial inspection...1 Handling and storage...1 Quality standards................................................................................1 GENERAL APPLICATION RECOMMENDATIONS.... 1 INSPECTION.... 1 IDENTIFICATION... 1 ASSEMBLY.... 1 Base or foundation mounting...2 Bracket or structure mounting...2 Suspension mounting...2 ELECTRICAL CONNECTIONS.... 4 MAINTENANCE.... 6 ii

! SAFETY FOR LIFE Safety for life Cooper Power Systems products meet or exceed all applicable industry standards relating to product safety. We actively promote safe practices in the use and maintenance of our products through our service literature, instructional training programs, and the continuous efforts of all Cooper Power Systems employees involved in product design, manufacture, marketing and service. We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high-voltage lines and equipment and support our Safety For Life mission.! SAFETY FOR LIFE Safety information The instructions in this manual are not intended as a substitute for proper training or adequate experience in the safe operation of the equipment described. Only competent technicians, who are familiar with this equipment should install, operate and service it. A competent technician has these qualifications: Is thoroughly familiar with these instructions. Is trained in industry-accepted high- and low-voltage safe operating practices and procedures. Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment. Is trained in the care and use of protective equipment such as flash clothing, safety glasses, face shield, hard hat, rubber gloves, clampstick, hotstick, etc. Following is important safety information. For safe installation and operation of this equipment, be sure to read and understand all cautions and warnings. Hazard Statement Definitions This manual may contain four types of hazard statements: DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a hazardous situation which, if not avoided, could result In death or serious injury. Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. Indicates a hazardous situation which, if not avoided, could result in equipment damage only. Safety instructions Following are general caution and warning statements that apply to this equipment. Additional statements, related to specific tasks and procedures, are located throughout the manual. DANGER Hazardous voltage. Contact with high voltage will cause death or severe personal injury. Follow all locally approved safety procedures when working around high- and low-voltage lines and equipment. WARNING Before installing, operating, maintaining, or testing this equipment, carefully read and understand the contents of this manual. Improper operation, handling or maintenance can result in death, severe personal injury, and equipment damage. WARNING This equipment is not intended to protect human life. Follow all locally approved procedures and safety practices when installing or operating this equipment. Failure to comply may result in death, severe personal injury and equipment damage. WARNING Power distribution and transmission equipment must be properly selected for the intended application. It must be installed and serviced by competent personnel who have been trained and understand proper safety procedures. These instructions are written for such personnel and are not a substitute for adequate training and experience in safety procedures. Failure to properly select, install or maintain power distribution and transmission equipment can result in death, severe personal injury, and equipment damage. iii

Eaton s Cooper Power series VariSTAR Type AZE surge arrester is designed to be operated in accordance with safe operating procedures. These instructions are not intended to supersede or replace proper safety and operating procedures. Read all instructions before installing the arrester. Surge arresters should be installed and serviced only by personnel familiar with good safety practice and the handling of high-voltage electrical equipment. Product information Introduction VariSTAR AZE station class surge arresters incorporate the latest in metal oxide varistor (MOV) technology. These arresters are totally gapless and are constructed of a single series column of MOV disks. The arrester is designed and tested to the requirements of standard IEEE Std C62.11 standard and is available in ratings suitable for the overvoltage protection of high-voltage systems through 345 kv. Read this manual first Read and understand the contents of this manual and follow all locally approved procedures and safety practices before installing or operating this equipment Additional information These instructions cannot cover all details or variations in the equipment, procedures, or process described nor provide directions for meeting every possible contingency during installation, operation, or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for the user s purpose, please contact your Eaton representative. Acceptance and initial inspection The factory takes special precautions to ship the arresters in well-designed containers that reduce the possibility of damage, which may occur during transit. Carefully inspect each arrester for physical damage. In case of improper handling or shipping damage, immediately file a claim with the carrier and promptly notify Eaton representative. Handling and storage If the arrester is to be stored for an appreciable time before installation, provide a clean, dry storage area. Locate the arrester so as to minimize the possibility of physical damage. General application recommendations Eaton s Cooper Power series product application engineers are available to make specific application recommendations. Inspection The factory takes special precautions to ship arresters in well designed containers that reduce the possibility of damage which may occur during transit. Carefully inspect the porcelain for chips or cracks. In case of improper handling or shipping damage, immediately file a claim with the carrier, and promptly notify Eaton. Do not install arresters that have evidence of damage. Identification A nameplate attached to the base casting of each VariSTAR arrester indicates its catalog number, voltage rating, maximum continuous operating voltage (MCOV), rated frequency, pressure-relief current rating, class, reference to the type test standard, altitude range, serial number, and year of manufacture. For multiple unit arresters, a nameplate attached to the top casting of each unit indicates the catalog number and serial number of the complete arrester of which the unit forms a part. The unit nameplate also indicates the total number of units comprising the complete arrester and references the position of this unit in the complete assembly. Always handle surge arresters carefully. Dropping or jarring an arrester may cause serious damage to the porcelain and/or internal parts and may cause catastrophic failure upon energization. Assembly VariSTAR Type AZE arresters rated 3 through 120 kv are shipped ready for installation. The 132 through 360 kv standard arresters require the assembly of multiple units stacked in a series. A grading ring is supplied for arresters rated 172 through 360 kv. Some lower voltage ratings having extra creepage housings may require multi-units stacked in series and grading rings. Grading ring assembly instructions are shown in Figure 6, 7 and 8. Quality standards ISO 9001 Certified Quality Management System 1

Choose a permanent location so that the arresters will be installed as close as possible (electrically) to the equipment being protected. Minimum clearance distances between any line potential surface to an arrester and to any ground plane are listed in Tables 2 and 3. Figures 1 and 2 show minimum phase-to-phase clearances. See Tables 2 and 3 and Figures 9 and 10 for standard arrester dimension and weight information. 0.5 The values shown in Tables 2 and 3 are the minimum clearances recommended by Eaton. These minimum clear-ances may be increased to meet local or system requirements for spacing of energized equipment. Safe operating practices must always be followed. Make electrical connections so that no mechanical stress is applied to the arrester. Base or foundation mounting Pier footings should extend below the frost line. Elevate the foundation sufficiently above the ground line for personnel safety and to prevent contamination from ground splash, drifting snow, flood water, or other contaminating conditions. If the top of the foundation is not level, shims will be required for leveling. Layout mounting dimensions for the foundation are shown in Figure 3. Figure 1. Three-phase triangular mounting CLAMP 3.0 (7.62 cm) 1.75 (4.44 cm) VENT PORT 0.75 (1.90 cm) 0.866 TYPICAL 4 PLACES 3.75 (9.52 cm) The vent port in the base must be directed away from equipment to prevent ionized gases from damaging adjacent equipment in the unlikely event of arrester failure. Bracket or structure mounting When bolting arresters directly to structures, or mounting brackets, make the assembly rigid enough to prevent mechanical failure. 0.56 (1.43 cm) DIA HOLES ON 1.75 (4.44 cm) CENTERS Figure 4. Line terminal cap (metal-top design) 3.0 (7.62 cm) Suspension mounting AZE arresters rated through 168 kv can be suspensionmounted. Either the top or bottom of suspension-mounted arresters can be connected to the line as long as the sheds on the porcelain housings are not inverted. TYPICAL 4 PLACES 1.75 (4.44 cm) 3.75 (9.52 cm) To suspension mount arresters with duty cycle ratings from 172 to 198 kv, invert the grading ring, then attach it to the base of the arrester. See Figure 7 for diagram. For additional information regarding suspension mounting, contact your Eaton representatives. To prevent strains on the arrester when suspensionmounting, suspend it freely. Always make flexible connections to line and earth terminals. 0.56 (1.43 cm) DIA HOLES ON 1.75 (4.44 cm) CENTERS Figure 5. Ground terminal (also line terminal of cubicle-mount designs) 2

MOUNTING TAB MOUNTING TAB MOUNTING TAB ARRESTER Ratings =172-240 kv ARRESTER RATINGS = 258-288 kv ARRESTER Ratings = 294-360 kv PLACE THE (3) GRADING RING MOUNTING TABS UNDER LINE TERMINAL CAP. Figure 6. Grading ring assembly. Arresters with extra creepage housings may require grading rings in different voltage ratings. MOUNTING TAB Figure 7. Diagram of Suspension Mounted Arrester from 172 to 198 kv Figure 8. Grading ring assembly for arresters with duty cycles of 172 to 198 kv To develop rated cantilever strength use 10 inch bolt circle mounting diameter and 0.5 inch hardened bolts and flat washers. 3

42" (107 cm) DIA. 7" (18 cm) 42" (107 cm) DIA. 7" (18 cm) 55" (140 cm) DIA. 7" (18 cm) 26 (66 cm) DIA. 16 * (40 cm) 24" (60 cm) 24" (60 cm) 30 (77 cm) 3-120 kv 132-168 kv 172-240 kv 258-288 kv 294-312 kv 330-360 kv *FOR 172 KV ARRESTER DIMENSIONIS 12" (30 CM) Figure 9. Dimensions of VariSTAR metal-top Type AZE surge arresters Refer to Table 2 for Dimension. Electrical connections Install the arrester as close as possible (electrically) to the apparatus being protected. Line and ground connections must be short and direct. Make the ground connection to a solid, effective and permanent low-resistance ground. Equipment protection will be improved by interconnecting the arrester ground connections with the transformer tank and system neutral whenever possible. (3) 0.625" x 1.27" (1.6 x 3.2 cm) LG. MTG. SLOTS (120 APART) 8.75"-10" (22.2 25.4 cm) DIA. BOLT CIRCLE* 60 120 The standard line and ground terminals (Figures 4 and 5) include connector clamps that accommodate up to.75 inch stranded copper or aluminum conductor. The line and ground terminals allow the connector clamp to be positioned for vertical or horizontal conductor takeoff; in addition, it accommodates NEMA standard two or four-hole connectors. THICKNESS OF MOUNTING FEET IS 0.875" (2.2 cm) C Figure 3. Base mounting details *To develop rated cantilever strength use 10 inch bolt circle mounting diameter and 0.5 inch hardened bolts and flat washers. C VENT PORT Figure 2. Three-phase in-line mounting Refer to Table 1 for Dimensions and C. 4

Table 1. Dimensional information and weights for type aze metal-top surge arresters in standard housings Arrester rating kv, rms) Arrester MCOV (kv, rms) Figure 7 Dim. (in.) Figures 1 & 2 Dim. Minimum Clearance Phase-to-Phase (in.) Figure 2 Dim. C Minimum clearance phase-to-ground (in.) Weight (lbs.) AZES AZEH AZEX AZES AZEH AZEX AZES AZEH AZEX 3 2.55 18.6 12 12 12 6 6 6 42 42 42 6 5.10 18.6 12 12 12 7 7 6 42 43 44 9 7.65 18.6 13 13 12 7 7 7 43 44 45 10 8.40 21.1 13 13 13 7 7 7 48 49 50 12 10.2 21.1 14 13 13 8 8 7 49 50 52 15 12.7 21.1 14 14 14 9 8 8 49 51 53 18 15.3 24.8 15 15 14 10 9 9 56 58 63 21 17.0 24.8 16 16 15 11 10 9 57 59 65 24 19.5 24.8 16 16 15 11 10 9 58 60 66 27 22.0 28.6 17 17 16 12 11 10 65 68 77 30 24.4 28.6 18 17 17 13 12 11 65 68 77 33 27.5 28.6 20 19 18 14 13 12 66 69 79 36 29.0 28.6 20 19 18 14 13 13 66 70 80 39 31.5 33.6 21 20 19 15 14 13 77 81 95 42 34.0 33.6 22 21 19 16 15 14 78 82 96 45 36.5 33.6 23 21 20 17 16 14 78 83 98 48 39.0 33.6 24 22 21 18 17 15 78 83 98 54 42.0 36.6 25 23 22 20 18 16 86 91 114 60 48.0 36.6 28 25 24 22 20 18 87 93 117 66 53.0 39.4 30 27 25 24 21 20 96 102 130 72 57.0 39.4 31 28 27 26 23 21 97 104 131 78 62.0 48.0 33 30 28 28 25 22 116 123 156 84 68.0 48.0 36 32 30 30 27 24 118 125 159 90 70.0 48.0 36 33 31 31 27 25 118 126 159 96 76.0 48.0 39 35 32 33 29 27 119 128 162 108 84.0 56.5 42 38 35 36 32 29 161 170 206 120 98.0 56.5 43 39 37 34 175 213 132 106 71.5 46 42 40 36 191 243 138 111 71.5 47 43 42 38 193 246 144 115 74.4 49 45 43 39 202 258 162 130 80.1 54 49 48 44 217 277 168 131 82.9 54 50 48 44 225 287 172 140 83.2 72 67 59 54 237 300 180 144 88.9 73 68 60 55 270 332 192 152 88.9 76 71 63 58 273 336 198 160 91.8 79 73 66 60 283 350 204 165 100.3 81 75 68 62 303 374 216 174 100.3 84 78 71 65 306 378 228 182 108.9 86 80 73 67 348 422 240 190 108.9 89 83 76 70 351 426 258 209 123.9 105 84 472 264 212 123.9 106 85 473 276 220 132.5 108 87 499 288 230 132.5 111 90 503 294 235 135.3 113 92 524 300 239 135.3 114 93 526 312 245 141.0 116 95 558 330 267 152.4 136 108 605 336 269 152.4 136 109 606 360 289 161.0 143 115 655 Phase-to-phase clearances are expressed as minimum arrester centerline-to-centerline distances and are based upon arrester protective levels. 5

Table 2. Dimensional information and weights for type AZE cubicle-mount surge arresters in standard housings Arrester rating (kv, rms) Arrester MCOV (kv, rms) Figure 8 Dim. (in.) Figures 1 & 2 Dim. minimum clearance Phase-to-Phase (in.) Minimum clearance phase-to-ground (in.) Figure 2 Dim. C weight (lbs.) AZES AZEH AZES AZEH AZES AZEH 3 2.55 13.4 8 8 4 4 23 23 6 5.10 13.4 8 8 5 5 24 24 9 7.65 13.4 8 8 5 5 24 25 10 8.40 15.9 8 8 5 5 29 30 12 10.2 15.9 9 9 6 5 30 31 15 12.7 15.9 10 10 7 6 30 32 18 15.3 20.2 11 10 8 7 38 39 21 17.0 20.2 12 11 8 8 38 40 24 19.5 20.2 12 11 9 8 39 41 27 22.0 23.4 13 12 10 9 47 49 30 24.4 23.4 14 13 11 10 47 49 33 27.5 23.4 15 14 12 11 47 50 36 29.0 23.4 16 15 12 11 48 51 39 31.5 28.4 17 16 13 12 59 63 42 34.0 28.4 18 16 14 13 60 64 45 36.9 28.4 19 17 15 14 60 65 48 39.0 28.4 20 18 16 15 60 65 Eaton recommends that a line terminal load limit of 100 pounds not be exceeded on cubicle mount designs. Excessive loading could lead to a shortened arrester life. Maintenance WARNINGe: Before working on arresters, disconnect all line leads. Consider any part of an arrester dangerous when connected to the line, including a base not solidly grounded. VariSTAR Type AZE arresters require no special maintenance under normal conditions. If the arrester is installed in an area of severe contamination, keep the arrester housing clean by washing periodically. Keep line and ground connections tight. WARNINGe: Arresters can be washed while energized provided standard live washing procedures are followed. Table 3. Cantilever strength of metal-top AZE surge arresters AZE Type AZES Arrester Rating 3-240 kv 258-360 kv AZEH Arrester Rating 3-108 kv 120-240 kv AZEX Arrester Rating 3-48 kv 54-108 kv Cantilever Strength (in-lbs)* 90,000 120,000 90,000 120,000 90,000 120,000 * Maximum working load should not exceed 40% of these values. 6

Figure 4. Dimensional drawing of VariSTAR cubicle-mount type AZE surge arrester Refer to Table 3 for dimension. 7

! SAFETY FOR LIFE Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2016 Eaton All Rights Reserved Printed in USA Publication No. MN235022EN Rev. 0 (Replaces S235871 Rev. 3) November 2016 Eaton is a registered trademark. All trademarks are property of their respective owners. For Eaton s Cooper Power series product information call 1-877-277-4636 or visit: www.eaton.com/cooperpowerseries.