Foam Chamber Model-FC

Similar documents
AIR FOAM CHAMBER DATA SHEET

FOAM TANK (1/2) DATA SHEET

FOAM TANK (1/2) DATA SHEET

BLADDER TANK PROPORTIONING SYSTEM PRE-PIPED

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

Foam Systems. Fire Protection Solutions

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

Wet pipe low flow foam/water system

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

TECHNICAL DATA. than the water inlet pressure to the concentrate

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

Thermocirc Installation and Maintenance Instructions

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

OBSOLETE. Wet pipe low flow manifold system

VERTICAL BLADDER TANK

HORIZONTAL BLADDER TANK

Water. VAG DUOJET Automatic Air Valve Single-chamber type PN 10/16/25/40 - DN KAT-A 1912

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

A comprehensive approach to monitor weight of fire extinguishing agent

TECHNICAL DATA CAUTION

Pipe-Away Pressure Vacuum Vent /Conservation Vent

TECHNICAL DATA NOTICE

Bermad Model:

Bladder Tank Installation & System Design Information

Model MTB-ASME Vertical Bladder Tanks

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks

DAV - WP DAV - WP. Wastewater Air Valves. Product Catalogue. (Wastewater Air Valves) DAV - WP

TECHNICAL DATA OBSOLETE

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

CLASS TLP Pressure Reducing Valve

TECHNICAL DATA OBSOLETE

Horizontal Bladder Tanks

FLOMIXERS SELECTION DATA ALL GASES

Vertical Bladder Tanks

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

OBSOLETE DESIGN DATA. Foam 301a. February 9, 1998

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3.

C 10 Pressure Reducing Valve

Blowdown vessels Meeting the requirements of HSE PM60

Float valves Types SV 4, SV 5 and SV 6

SCA Series Inverted Bucket Steam Traps

Fire & Rescue Service Equipment Manual Branch - Foam Chubb FB5X Foam Making Branch Table of Contents 1 General Description Primary Function...

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Model 420-HY Pressure Regulating Hydrant Valve

Wastewater combination air valve in stainless steel AISI 316 Mod. SCS

Flow Material Length. Weight GPM LPM. Style 3095

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

TECHNICAL DATA. Trimpac 257a. September 16, 2013

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

TECHNICAL DATA. Trimpac 256a. October 31, 2013

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

OWNER S TECHNICAL MANUAL

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

Technical Data. Approvals UL and C-UL Listed FM Approved. Maximum Working Pressure 250 psi (7,2 bar) Friction Loss Refer to Graphs A and B

INSTALLATION, OPERATING & MAINTENANCE MANUAL WATER DRAIN VALVE

Self-operated Pressure Regulators for special applications

LINE PROPORTIONERS LP NPR260 Approvals: UL, ULC

Eaton Filtration, LLC

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Vertical and Horizontal Bladder Tanks

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

BALANCED PRESSURE PROPORTIONERS

TECHNICAL DATA Q= C. Table 1 - Specifications

Hodge Clemco Ltd. SG-300 Suction Gun. Owner s Manual. Hodge Clemco Ltd

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

for Building facilities Industrial facilities etc.,multipurpose Pilot operated type(high capacity)

CA10S, CA14 and CA14S Air and Gas Traps

IFS NUVENT SERIES IWF FOR POTABLE WATER ANTI SLAM AIR RELEASE AND VACUUM BREAK AIR VALVES

Foam Mixers & Proportioning Systems

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

INSTALLATION OPERATION MAINTENANCE

Fig 1, Fig 12, Fig 13, Fig 14, Fig 16 and Fig 16L Strainers Installation and Maintenance Instructions

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE. 4. TECHNICAL DATA Approvals:

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

PRO SINK -R 1 and 2. Dilution system CONTENTS

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Bermad Pressure Reducing. Model: 42T

InnovDos Foam proportioning system

2-port seat valves PN25 with externally threaded connections

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

InnoVfoam B.V. InnovDos Foam Proportioning System

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

DUPLEX TECHNICAL INFORMATION FABRICATED DUPLEX STRAINERS

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Halsey Taylor Owners Manual STOP!

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Transcription:

Tel: 00-44-8450751042 Fax: 00-44-8450751043 Email: info@fireguard-uk.com 2nd FLOOR 145-157 ST.JOHNS STREET LONDON EC1V 4PY UNITED KINGDOM Foam Chamber Model-FC TECHNICAL DATA : MODEL SIZE inlet WORKING PRESSURE FC 50, 65, 80, 100 &150 NB Minimum 2.8 Kg. / sq. cm. (40 PSI) Maximum 7 Kg. / sq.cm. FLANGE CONNECTION ANSI B16.24 150# for Bronze ANSI B16.5 Class 150# for Stinless Steel APPROXIMATE FC 50-28.0 Kg. NET WEIGHT FC 65-35.0 Kg. FC 80-52.0 Kg. FC 100-78.0 Kg. FC 150-108.0 Kg. VAPOUR SEAL RUPTURE PRESSURE MAXIMUM PERMISSIBLE BACK PRESSURE ON VAPOUR SEAL FINISH ORDERING INFORMATION 0.7 to 1.75 Kg./sq.cm. Running water/water foam solution pressure at the inlet of Foam Chamber. 0.06 Kg./sq.cm. Red epoxy painted a) Model and size b) Inlet pressure. c) Foam solution flow reqd. d) Inlet, outlet flange specification. e) Type of foam concentrate used. APPLICATION Foam Chamber is used in one of the most common application to protect vertical fixed roof (cone) liquid storage tanks, with or without internal floating roof with the low expansion foam system. The application of the foam is on the basis that the risk comprises the total surface area of the fuel. The foam system design guidelines generally used are in accordance with NFPA-11, standard. Foam Chambers are defined by NFPA-11 as Type II discharge outlets for delivering the foam to the surface of a flammable liquid. The Foam Chambers are widely used with the In-line foam inductor, Balance pressure foam proportioning system, Bladder tank proportioner or Foam tender. SPECIFICATION Foam chamber is an air aspirating foam discharge device, covering wide range of flow from 75 to 3600 litres per minute at 2.8 to 7 kg/sq.cm inlet pressure. The foam chamber contains a vapour seal to prevent the entry of vapour into the foam chamber and the foam solution pipe. Each foam chamber is supplied with an orifice plate, designed for the required flow and inlet pressure. The orifice is field replaceable in the event of change in design conditions. The foam is produced by introducing air into the foam solution stream. The inlet of foam chamber is designed to create venturi jet which draws air into the foam solution stream. The air is drawn into the foam solution through the holes located on the foam chamber covered with stainless steel screen to exclude nesting birds and insects. The aerated foam is directed into the deflector for the gentle application of the expanded foam. The deflectors are available in different models. On removal of cover plate from the top of the chamber allows the system to be tested and to draw a sample of the expanded foam, without removing the vapour seal or disconnecting the foam chamber from the tank. Frangible glass bursting disc (vapour seal) can be replaced very easily. SYSTEM DESIGN REQUIREMENT The NFPA-11, a standard for low expansion foam, provides the essential requirement of an appropriate correctly designed foam pouring system, which are identified and outlined as following: The Foam Deflector is used with the Foam Chamber. The aerated foam from the Foam Chamber is directed in to the deflector for the gentle application of the expanded foam. The deflector reduces the expanded foam velocity and allows the foam to slide down the tank wall.

FIREGUARD SAFETY EQUIPMENT CO. LTD. www.fireguard-uk.com Foam Chamber Model-FC a) Number of Foam Chamber The number of foam chambers required is determined by the tank diameter. Where two or more foam chambers are required, they shall be spaced equally around the tank periphery and each Foam Chamber shall be sized to deliver foam at an approximately same rate. Please refer graph to select the unit that will provide the required minimum foam solution application rate at the available operating pressure of the Foam Chamber. For minimum number of Foam Chamber requirement follow the recommendations as per NFPA/ OISD/TAC or as per the governmental codes or ordinances wherever applicable. b) Minimum Foam Solution Application Rate The minimum foam solution application rate is the rate at which the water and foam concentrate in correctly proportioned ratio should be delivered to the surface of a storage tank under protection to control and extinguish the fire. For minimum application rate requirement follow the recommendations as per NFPA/ OISD/TAC or governmental codes or ordinances wherever applicable. Testing And Maintenance Qualified and trained person must commission the system. After few initial successful tesst an authorized person must be trained to perform inspection and testing of the system. It is recommended to carry out physical inspection of the system regularly. The system must be fully tested at least once in a year or in accordance with applicable NFPA/OISD/TAC standards or in accordance with standards of the organization having local jurisdiction. Do not turn off the system or any valve to make repair or test the system, without placing a roving Fire Patrol in the area covered by the system. The Patrol should continue until the system is put back in service. Also inform the local security guard and control alarm station, so as to avoid false alarm. Each system is to be flushed properly. The vapour seal must be replaced if the system has been operated. Normal testing of the chamber can be carried out by removing the cover plate from the top of the chamber. This allows the system to draw a sample of the expanded foam without removing the vapour seal or disconnecting the Foam Chamber from the tank. The air screen is to be inspected periodically for the obstruction of air inlet holes. If any obstruction is noticed, remove the same and flush if necessary. It is recommended to have regular maintenance programme to inspect the Vapour Seal Chamber discharge area and deflector for possible deposit or obstruction. NOTE A PROVISION IS TO BE MADE FOR PRESSURE GAUGE MOUNTING AT INLET OF CHAMBER, WHICH CAN BE PLUGGED AFTER SUCCESSFUL COMMISSIONING OF THE SYSTEM. THIS WILL HELP TO ANALYSE THE SYSTEM WHILE COMMISSIONING. Selection Of Foam Chamber SIZE OF K-FACTOR CHAMBER 50 NB 43.4 to 127 65 NB 115.4 to 254 80 NB 230.9 to 508 100 NB 461.8 to 1016 150 NB 923.6 to 1524.2 To select the size of the Foam Chamber use the following formula Q=K P Q = Total solution flow in litres per minute. K = Constant for Foam Chamber P = Inlet pressure in kg/sq.cm. Example To find K-Factor Q = 300 LPM P = 3.5 Kg/sq.cm. K = 300 3.5 = 160.35 This K-Factor falls within the range of the Foam Chamber having 65 NB size. Hense 65 NB size of Foam Chamber should be selected. The Foam Chamber size may also be selected with the help of the graph. Calculation example Tank type : Fixed roof storage tank Tank diameter : 40 meters. Foam concentrate to be used : AFFF 3% Pressure at inlet of Foam Chamber : 3.5 kg/sq.cm. Flash point of liquid stored in tank : - 27 C. Surface area = d 2 4 = ( 3.14 X 40 2.) 4 = 1257 Sq. mts. a) Foam solution application rate = *4.1 LPM /Sq. mts. X Surface area = 4.1 X 1257 = 5154 LPM *4.1 LPM is as per NFPA-11 ( 5 LPM as per OISD recommendations ) or it should be as per prevailing rules of local authority having jurisdiction. b) Number of Foam Chamber required for 40 metres diameter tank = 3 nos. minimum (Reference NFPA-11) Capacity of Foam Chamber required = 5154 3 = 1718 LPM The K-Factor for flow of 1718 LPM at 3.5 kg./sq.cm. K = Q P = 1718 3.5 = 918.30 Company Registration No. 5717368 V.A.T No. 883908672

Tel: 00-44-8450751042 Fax: 00-44-8450751043 Email: info@fireguard-uk.com 2nd FLOOR 145-157 ST.JOHNS STREET LONDON EC1V 4PY UNITED KINGDOM Foam Chamber Model-FC The K-Factor (918.30) falls within the K-Factor of 100 NB size of the Foam Chamber. Hence three numbers of 100 NB Foam Chamber with 1718 LPM capacity at 3.5 kg./sq.cm inlet pressure are to be selected. Note THE ABOVE ARE THEORETICAL CALCULATIONS. IT IS, THEREFORE, RECOMENDED THAT SYSTEM DESIGNER CONSIDERS AN APPROPRIATE FACTOR OF SAFETY c) Foam Concentrate Requirement : The fuel stored has flash point of 27 C. So the minimum system running duration recommended is 55 minutes. (Reference NFPA-11) The foam concentrate required = foam solution application rate in LPM X percentage of foam concentrate X system running time Add 5% = 5154 X 3 X 55 100 = 8505 litres. = 8930 litres. The supplementary hose stream requirement is also to be considered and 100% reserve stock to be maintained or as per authority having jurisdiction. The additional quantity of 5% is general guideline, however system designer has to work-out this percentage considering factor of safety, pipeline, minimum level for induction in storage tanks etc. Note 1. It is recommended to select next higher size of Foam Chamber when the K-Factor is very much close to upper limit of the model. 2. For the best performance the inlet pressure at the Foam Chamber should be 2.8 kg/sq.cm. or higher.

FIREGUARD SAFETY EQUIPMENT CO. LTD. www.fireguard-uk.com Foam Chamber C 9 8 7 13 6 5 A 14 F2 16 B A 4 DETAIL A 11 15 3 2 1 10 12 F1 DIMENSION in millimetre ( Approximate ) INLET OUTLET ( F1 ) (F2) A B C 50 NB 80 NB 630 518 160 65 NB 100 NB 720 589 175 80 NB 150 NB 1050 895 225 100 NB NB 1175 986 275 150 NB 250 NB 1250 1020 325 - Dimension of inlet / outlet flanges ( F1 / F2 ) are as per ANSI B16.5 - Pipes used are ERW (Seamless Pipes are optional on request) PART LIST ITEM DESCRIPTION MATERIAL SPECIFICATION NO. 1 ORIFICE PLATE S.S. 304 2 INLET FLANGE STEEL A105 3 AERATING PIPE STEEL PIPE 4 MAKING CHAMBER STEEL PIPE 5 CHAMBER STEEL PIPE 6 CHAMBER FLANGE STEEL 7 GASKET NEOPRENE 8 INSPECTION HATCH STEEL 9 BOLT STEEL 10 VAPOUR SEAL RING & SEAT STEEL 11 VAPOUR SEAL GLASS 12 WING NUT & STUD S.S. 304 13 DISCHARGE PIPE STEEL PIPE 14 OUTLET FLANGE STEEL 15 AIR STRAINER S.S. 304 16 CHAMBER PLATE STEEL Company Registration No. 5717368 V.A.T No. 883908672

Tel: 00-44-8450751042 Fax: 00-44-8450751043 Email: info@fireguard-uk.com 2nd FLOOR 145-157 ST.JOHNS STREET LONDON EC1V 4PY UNITED KINGDOM Pressure Vs Flow Performance Characteristic 400 300 100 2600 2400 2 0 1800 1600 1400 1 1000 800 2 3 4 5 6 7 8 2 3 4 5 6 7 8 INLET PRESSURE (KG./SQ.CM.) INLET PRESSURE (KG./SQ.CM.) SIZE 50NB SIZE 100NB 4000 800 600 400 3700 3400 3100 2800 2500 2 1900 1600 2 3 4 5 6 7 8 INLET PRESSURE (KG/CM ) SIZE 65NB 2 3 4 5 6 7 8 INLET PRESSURE (KG./SQ.CM) SIZE 150NB 1400 1 1000 800 600 400 2 3 4 5 6 7 8 INLET PRESSURE (KG./SQ.CM) SIZE 80NB

FIREGUARD SAFETY EQUIPMENT CO. LTD. www.fireguard-uk.com Typical Foam Chamber Installation with Deflector TANK NOZZLE TANK NOZZLE DEFLECTOR MODEL FD 150 150 150 150 CHAMBER CHAMBER DEFLECTOR MODEL FD 53 ORIFICE PLATE STORAGE TANK ORIFICE PLATE STORAGE TANK Note : Above dimension are general guideline only. The system designer can adopt the dimensions as per NFPA/TAC/OISD or as per the governing rules & ordinances having local jurisdiction. Company Registration No. 5717368 V.A.T No. 883908672