FOR THE PROTECTION AND DECORATIVE COLOURING OF ALUMINIUM

Similar documents
FOR THE PROTECTION AND DECORATIVE COLOURING OF ALUMINIUM

SCIENCE EXPERIMENTS ON FILE Revised Edition Tornado Model. Safety Please click on the safety icon to view safety precautions.

Section 2 Safety, Tools and Equipment, Shop Practices Unit 4 General Safety Practices. Unit Objectives. Pressure Vessels and Piping (1 of 2)

Model VR6 System. Installation, Operation & Maintenance

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

LogIT Dissolved Oxygen Probe

Kon-Tiki / E700 Series

MODEL 154XST INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL 154XST STROBE LIGHT FOR USE IN HARSH ENVIRONMENTS/ HAZARDOUS LOCATIONS

Automatic extractor outlet

ANY QUESTIONS? CONTACT ROYAL VENDORS CUSTOMER SERVICE DEPARTMENT IN NORTH AMERICA, CALL TOLL FREE

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

Build Your Own Flamethrower Step-by-step Manual

In Ground Buried Uplights

For Salvo Primary Dive Lights

An Inuit Yo-Yo Sandra J. Walton

Roy G. Biv Charles W. McLaughlin

INSTRUCTION MANUAL. January 23, 2003, Revision 0

Twin & Triple Control Concealed Thermostatic Shower Valve

RAM 4021 Operation Manual

Setting Instructions for Movement Caliber C080

Part A: 20 minutes plus 30 minutes setting time Part B: day 1, 20 minutes; then 5 minutes each day for about 5 days

Instruction Manual Updated 7/26/2011 Ver. 2.2

Standard Operating Procedure (SOP)

Sewable LED kits Teaching Notes Issue 1.1

Setting Instructions for Movement Caliber C330

Construction Chapters Index

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

Vacuum Bagging Wings Instruction Manual Purdue University

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

Spectrum AquaLight (SAL ) Color Underwater Light Owner s Manual

Code AWC20HP Air Compressor

Underwater Housing for Canon EOS M

Macro-Infusion Guide

TRI- B A L L H I TC H OWNER S MANUAL

Student Information & Laboratory Safety Contract

Behavior of the Simple Pendulum

Dissolved Oxygen Sensor

AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents

Equipment Maintenance Guide

PREPARATIONS FOR PIEZOCONE CPTU TESTING (De-airing and Saturating)

Friction Surfaces. Safety Precautions WHAT YOU NEED WHAT YOU NEED

1. Safety glasses are to be worn at all times in the laboratory except in the study area adjacent to the lab.

CamRT Sun Top Bimini Installation Instructions

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

Polatrak ROV II - Tip Contact Probe Operation Manual

WARNING TABLE OF CONTENTS:

Le Maitre Ltd. Co2 propelled Electric Air Cannon Instructions. & Loading instructions for Chinese Confetti, Streamers and Glitter

Sport Grouse PRO REMOTE CONTROL LAUNCHER INSTRUCTION MANUAL

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

12S 1st Stage. -Maintenance Procedure-

Simple, Robust, Reliable Measures ph Doses either acid (lower) or alkali (raise) Displays ph, Total Dose Count (DCT) and Dose Count per hour (DC/h)

RG1200 Service and Repair Manual

A28 Series Two-Stage Temperature Controls with NEMA 1 Enclosure

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM

longitudinal wave Figure 1 amplitude transverse wave Figure 2

Training. tm PA90 Series - Lung Demand Valve

1/4 SHEET PALM SANDER

Installation of Your SprayMaster System

Self-help Temperature Adjustment

Evaluation copy. Interdependence of Plants and Animals. computer OBJECTIVES MATERIALS

Best Practice for Calibrating LTH Conductivity Instruments

OPERATING INSTRUCTIONS

Making a Barometer and Using It

OPERATION MANUAL DIVE CALIPER NOT SCALE / IF IN DOUBT ASK* *ALL UNITS IN MM/DEGREES UNLESS SPECIF. Dive Caliper General DC-051

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

VERTICAL AIR COMPRESSORS

CHAPTER 5 REWIND STARTERS

How Fast Is Your Toy Car?

WIND CLIPPER KTS ILLUM SCALE INC DEC CLIPPER WIND SYSTEM

User Manual. MagnaMaster and ChloroMaster Electrolytic Chlorinator.

BOYLE S / CHARLES LAW APPARATUS - 1m long

Hand Safety. 1 Copyright 2014 by PEC Safety Management, Inc. PPT-SM-HNDSFTY 2014

Floor Drinking Systems

BD Cytopeia Fluidic Kit User s Guide

Welcome to your new Firepod It will only work properly on Propane Gas (Also known as LPG and Patio Gas) with the special regulator supplied

200L BELT DRIVEN AIR COMPRESSOR

Thank you for choosing Xuma.

24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO:

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

General Safety Rules

ALUMINIUM TANK AND COMPENSATOR - SERIES 09

ROCKS, FOSSILS AND SOILS SECTION 5: ENRICHING THE SOIL From Hands on Science by Linda Poore, 2003

System-C Tables Handling, Operation & Maintenance Manual

122 Lab 1: Electrostatics

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

Model 23H Hand Crank Seamer

K13.12 FACE FIXED PANIC EXIT DEVICE K13 DOORS

AIR/OVER HYDRAULIC JACK 20 TON

OXYGEN ACETYLENE WELDING & CUTTING EQUIPMENT

UNITY 2. Uni-DAAMS Manual. Version 1.3 (Changes to Section 1.1) March 2010

Sunbrite LTC Large Underwater Pool Lights

Natural Reaction Boosters C. V. Krishnan

Finishing Surfaces by Applying Treatments A/508/5116

INFLATOR TDUX-IT-16 AND GAS CYLINDER E

COLD WELD COPPER TUBE SAMPLING EQUIPMENT AND PROCEDURES

WELLS JOHNSON HIGH VOLUME CANISTERS

Oxygen Dialflow Meter. Instructions for Use

RIPPLE TANK - with rippler & kit

1. Introduction Why use the Flow-Through Cell? Component Identification... 1

Transcription:

BARVIC FOR THE PROTECTION AND DECORATIVE COLOURING OF ALUMINIUM

WHAT IS ANODISING? Anodising is the creation of an oxide layer on the surface of aluminium by electro-chemical means. This oxide layer protects the underlying metal and prevents further corrosion from taking place. An additional benefit of this process is that the oxide layer that is created will accept certain dyes, thus allowing aluminium items to be finished in a wide range of colours. GENERAL DESCRIPTION The system has been designed from scratch to provide an easy and safe method for the amateur to successfully anodise aluminium* at a low cost. All the latest developments in chemicals and electronics have been integrated into the design to produce excellent results. The system utilises electronic control of the current supplied to the anodising tank, and due to the low voltage involved there is no risk of electric shock. The power supply has built in electronic protection to prevent damage should fault conditions arise. * Aluminium items that have been cast are not able to be anodised. THE TANKS Four tanks are needed to complete the whole process. TANK 1 the anodising tank TANK 2 the rinsing tank (cold water) TANK 3 the dyeing tank (optional) TANK 4 the sealing tank (boiling water) The sealing tank needs to be able to store boiling water and be large enough to accommodate the item being anodised. The anodised part does not need to be fully submerged in the boiling water, but must be rotated so that the whole surface receives the full duration of sealing time.

TANK 1 ANODISING TANK WARNING THE ANODISING SOLUTION CONTAINS SULPHURIC ACID. ALWAYS WEAR GLOVES, EYE PROTECTION AND A MASK WHEN HANDLING THIS SOLUTION AND WHILE ANODISING IS TAKING PLACE. ANODISING SHOULD ONLY TAKE PLACE IN A WELL VENTILATED AREA, AWAY FROM CHILDREN, PETS AND OTHER CHEMICALS. DO NOT EAT, DRINK OR SMOKE OR USE NEAR OTHER SOURCES OF IGNITION. The anodising tank should be set up as in the diagram below.

ASSEMBLY OF THE ANODISING TANK The anodising solution is supplied in a 5 litre bottle and is ready to be used. It should be poured carefully into the tank before the rest of the set up is undertaken. PLEASE NOTE THE WARNING GIVEN PREVIOUSLY. There are two bars supplied together with four support clips, which are used to support the cathodes and the items to be anodised. The bars are pushed through the holes in the support clips. THE CATHODE BAR BLACK NEGATIVE The cathode bar is installed first and fits across the centre of the tank. It is installed in such a way that the centre section is sleeved against any electrical contact. There is a support clip at each end clipped onto the tank edges and the sleeving is between the two support clips, covering most of the bar between the two clips. Each lead cathode is now attached to a croc. clip lead and suspended into the solution by tying the lead onto the cathode bar at the required length, one at each end of the cathode bar as close as possible to the support clips. It is vital that these cathodes do not come into contact with the items being anodised. The cathodes are suspended into the solution as far as possible, but the croc clips must not contact the solution. The two croc. clips now remaining which are in contact with the cathodes are now clipped onto the metal part of the cathode bar which overhang the outside of the tank, close to each support clip. The cathodes will be supplied with a NEGATIVE supply. THE ANODE BAR RED POSITIVE The anode bar is suspended in a similar manner and lies at 90 degrees to the cathode bar. The purpose of the anode bar is to provide a suspension point for the items to be anodised and to carry electric current to those items. This bar is suspended across the tank using the two support clips, one at each end, and each item to be anodised is suspended into the solution using a croc. clip lead and aluminium rod for each item, tying off the croc. clip lead to a sufficient length to ensure full submersion of the item. It is vital that the RED croc. clip lead DOES NOT come into contact with the anodising solution.

Large items that are too heavy to be supported by a croc. clip lead can be connected to the anode bar by attaching a longer length of aluminium rod to the item to be anodised and wrapping it around the anode bar. If the croc. clip lead is used, the free end is connected to the anode bar at any point along its length. It is important that if more than one item is in the tank that they do not touch each other or the lead cathodes. The items to be anodised will be supplied with a POSITIVE supply. ELECTRICAL CONNECTIONS The red and black wires from the power supply are now connected to their respective bars. RED to unsleeved anode bar which supports the item to be anodised. BLACK to the cathode bar which supports the lead cathodes. The connectors are supplied fitted to the wires and should be attached to the bars using a small terminal screwdriver. All that remains now is to plug the power supply into the mains. ASSEMBLY OF THE DYEING TANK (optional) NO ELECTRICAL CONNECTIONS ARE MADE TO THIS TANK The dye is supplied in a 1 litre bottle and should be added to 4 litres of water to make a 5 litre mix in the dyeing tank. The dye temperature should then be raised to 30 degrees Celsius using the tank heater supplied. The agitator can now be installed but only needs to be active as the anodised item goes in the tank. The support bars should then be put in place in the same way as in the anodising tank. These bars are used to suspend the item being dyed so the part does not touch the sides, the bottom, the heater or any other part being dyed. This will ensure an even coverage of dye on the surface of the part.

The parts can be suspended using a croc. clip lead, aluminium rod or other means as no electrical connection is necessary. Whatever method is used, it is important that the flow of dye is not restricted to the area where the connection is made as this will result in an area of weak colour or no colour at all. THE SEALING TANK The sealing tank needs to hold boiling water and should be large enough to allow the whole of the anodised part to be submerged below the surface of the boiling water for the required time. This may be achieved by rotating the part in the boiling water during the sealing process. PREPARATION OF PARTS WARNING THE ONLY METALS THAT CAN ENTER THE ANODISING SOLUTION ARE LEAD AND ALUMINIUM. ANY OTHER METAL PARTS MUST BE REMOVED FROM THE ITEM BEFORE IT GOES INTO THE ANODISING TANK. It should first be determined that the aluminium part has not been previously anodised as an anodised surface will not allow the process to occur. The best way to test this is to measure the electrical surface resistance of the aluminium using a test meter. A low resistance indicates a non anodised surface, whereas a high resistance indicates an anodised surface. (This electrical conductivity test can be used to determine whether the anodising process has been successful.)

The item to be anodised can be attached to the aluminium rod that will provide it's electrical connection in one of two ways. The most convenient way is to use an existing hole in the item, pass the rod through and wrap around several times to ensure a good mechanical as well as electrical connection. If this is not possible then a small hole can be drilled in an unobtrusive place and the flattened end of the rod screwed into this hole. THE ANODISING PROCESS CAUSES THE ALUMINIUM TO BECOME NON -CONDUCTIVE, THEREFORE THIS CONNECTION MUST BE GOOD ENOUGH TO REMAIN THROUGHOUT THE ANODISATION PROCESS AS ONCE BROKEN IT IS IMPOSSIBLE TO REGAIN.THE PART OF THE ROD THAT IS IN CONTACT WITHTHE ANODISING SOLUTION WILL ALSO BECOME NONCONDUCTIVE AND SHOULD BE DISCARDED AFTER USE. It is important to be completely satisfied with the surface finish before starting the anodising process. It is very important that all oil or grease is completely removed from all items to be anodised. After finishing to the desired level it is important to prepare the surface with BARVIC cleaner/scourer to ensure satisfactory anodisation. Sprinkle a small amount onto the surface or make up a paste with clean water and using a moistened, lint free cloth rub all over the surface to be anodised. Use a toothbrush on areas with recesses or that are difficult to reach. Finally rinse in clean water and attach the free end of the aluminium rod to a croc. clip lead or wrap it around the anode bar. If a croc clip lead is used this should be connected to the anode bar. The item is now ready to be lowered into the solution.

ANODISING Large items may cause the bulb to light while anodising is taking place, whereas small items may not light the bulb at all. The way to tell if current is flowing in the tank if the bulb is not lit, is to observe the lead cathodes where surface action should be visible. If no action is observed check all of the electrical connections. The items can be left anodising for anything up to 3 hours, although 1-2 hours may be sufficient especially for smaller items if a strong depth of colour is not required. After anodising is complete the part should be removed from the tank and placed straight into the rinsing tank. After being THOROUGHLY rinsed the item should go either straight into the dyeing tank, or if no colour is required straight into the sealing tank. DYEING The item should be suspended so that it is not in contact with the tank or any other parts while being dyed. 20 minutes is the usual length of time required to produce a full colour, but if a weaker colour is desirable then a shorter time can be used. After dyeing is complete the item should again be rinsed before going into the sealing tank. SEALING Both dyed or uncoloured items are sealed in the same way by immersion in boiling water for 20 to 30 minutes. It is important that the whole surface of the item receives this duration of sealing time. It is normal during this stage for a small amount of dye to leach out into the sealing water. After being sealed the item can be waxed and polished gently to bring out the colour. The anodising solution should be stored in it's original container, which should be clearly marked as to its contents. The cathodes and other parts of the kit that have come into contact with the anodising solution should be thoroughly rinsed before being dried and stored away.