Rules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations

Similar documents
Construction, Fitting and Testing of Closed Fuel Overflow Systems

Rules for Classification and Construction Additional Rules and Guidelines

Rules for Classification and Construction Additional Rules and Guidelines

Rules for Classification and Construction Ship Technology

Rules for Classification and Construction Ship Technology

Instruction Manual. Pipe Friction Training Panel

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

DNVGL-CP-0187 Edition March 2016

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

AIR VENT HEADS STANDARD FOR CERTIFICATION DET NORSKE VERITAS. No. 2.9 Type Approval Programme No OCTOBER 2008

A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller.

DIMENSIONING WATER SUPPLY SYSTEM IN BUILDING

and its weight (in newtons) when located on a planet with an acceleration of gravity equal to 4.0 ft/s 2.

Hours / 100 Marks Seat No.

Experiment 8: Minor Losses

M-06 Nitrogen Generator (Nitrogen Making Machine)

ANNEX 18. RESOLUTION MSC.362(92) (Adopted on 14 June 2013) REVISED RECOMMENDATION ON A STANDARD METHOD FOR EVALUATING CROSS-FLOODING ARRANGEMENTS

Self-operated Pressure Regulators for special applications

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

MEMORIAL UNIVERSITY OF NEWFOUNDLAND Faculty of Engineering and Applied Science FLUID MECHANICS LABORATORY PIPE FRICTION

Experiment Instructions. Circulating Pumps Training Panel

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

The capacity of the cargo tank venting system (46 CFR );

Gas Pressure Regulator HON 300

INTERIM GUIDELINES FOR DETERMINING MINIMUM PROPULSION POWER TO MAINTAIN THE MANOEUVRABILITY OF SHIPS IN ADVERSE CONDITIONS

ASX 176 Axial Pressure regulator

Applied Fluid Mechanics

Periodic Survey of Fuel Installations on Ships other than Liquefied Gas Carriers utilizing gas or other low flash point fuels

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

Irrigation &Hydraulics Department lb / ft to kg/lit.

Safety shut-off valve S 50. Product information

SLOP RECEPTION AND PROCESSING FACILITIES

Fuel Filters DN15 DN25. elektrogas.com DE

GUIDELINES FOR SURVEY OF OIL FLOATING STORAGE VESSELS FIXED AT ANCHORAGE

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

safety shut-off Valve HON 703 / HON 704

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

SAV. Safety Shut-off Valve. Safety Shut-off Valve Type SAV

APPENDIX 4 STANDARD FORMAT FOR THE PROCEDURES AND ARRANGEMENTS MANUAL

LECTURE 20 FLOW CONTROL VAVLES SELF EVALUATION QUESTIONS AND ANSWERS

MSC Guidelines for Vents, Fills and Sounds

Citation for published version (APA): Somer, F. M. J. J. D. (2003). Strategies for optimisation of paediatric cardiopulmonary bypass s.n.

RB 4700 Commercial & Industrial Regulator

REFERENCE GUIDE. Rev. 0 15/09/2016

Installation and commissioning instructions 255 series and 256 series

Guidelines for Clean Agent Fire Suppression Systems

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

Safety shut-off valve S 100. Product information

RULES PUBLICATION NO. 119/P

01 18/11/2013 correction of the reference of the product 1 4 5

S-Type Pitot Tube. Operating Instructions

RESOLUTION A.567(14) adopted on 20 November 1985 REGULATION FOR INERT GAS SYSTEMS ON CHEMICAL TANKERS

Gas Filters DN15 DN300. delta-elektrogas.com EE151 03/17

Hours / 100 Marks Seat No.

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

G SPECIFICATION: TITLE: VOLUME: 4 REVISIONS:

Explanations hydraulic valves TECHNICAL EXPLANATIONS HYDRAULIC VALVES. Contents. 1. Foreword. 2. Characteristic Values

Pressure transmitters EMP 2

TECHNICAL DATA Q= C. Table 1 - Specifications

Gerald D. Anderson. Education Technical Specialist

Calculations of hydraulic resistance of simple pipelines for liquid viscous and non-newtonian products.

F All types of inert gas systems are to comply with the following:

Gas Pressure Regulator HON 200

4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: +44 (0) Fax: +44 (0)

Tutorial. BOSfluids. Relief valve

TECHNICAL DATA. Table 1 - Specifications

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

RR 16 Commercial & Industrial Regulator

FLUID MECHANICS Time: 1 hour (ECE-301) Max. Marks :30

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

CVEN 311 Fluid Dynamics Fall Semester 2011 Dr. Kelly Brumbelow, Texas A&M University. Final Exam

Mounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection)

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

PHYS 101 Previous Exam Problems

TECHNICAL DATA. than the water inlet pressure to the concentrate

TECHNICAL CIRCULAR. Circular No: S-P 32/13 Revision: 1 Page: 1 of 7 Date:

Pipeline Flooding, Dewatering and Venting Dr Aidan O'Donoghue, Pipeline Research Limited, Glasgow, Scotland

Operating Manual FSV, FSÖV, SSVF

INSTALLATION OPERATION MAINTENANCE

Controllers DR, DP, FR and DFR

RULES FOR CLASSIFICATION Naval vessels. Part 1 Classification and surveys Chapter 5 Surveys for submarines. Edition January 2016 DNV GL AS

Gas Vapor Injection on Refrigerant Cycle Using Piston Technology

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

THE REPUBLIC OF LIBERIA LIBERIA MARITIME AUTHORITY

RULES FOR CLASSIFICATION Ships. Part 3 Hull Chapter 5 Hull girder strength. Edition October 2015 DNV GL AS

Organisation Internationale de Métrologie Légale

Gas Filters DN15 DN300. elektrogas.com EE151 06/13

SIZING AND CAPACITIES OF GAS PIPING

Type 4708 Supply Pressure Regulator

API MPMS Chapter 17.6 Guidelines for Determining the Fullness of Pipelines between Vessels and Shore Tanks

ANNEX 16 RESOLUTION MEPC.232(65) Adopted on 17 May 2013

Osborne Engineering Limited. OEJ Equalised thrust bearing internals

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Operational Behaviour of Safety Valves with Constant Superimposed Backpressure

SIZING AND CAPACITIES OF GAS PIPING

ANNEX 4 ALTERNATIVE TEXT FOR OPERATIONAL GUIDELINES FOR VERIFICATION OF DAMAGE STABILITY REQUIREMENTS FOR TANKERS

APPLYING VARIABLE SPEED PRESSURE LIMITING CONTROL DRIVER FIRE PUMPS. SEC Project No

GENO -Flushing Compressor Product Data Sheet F 02

OVERALL SURVEY: A survey intended to report on the overall condition of the hull structure and determine the extent of additional close-up surveys.

Transcription:

VI Rules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations 6 Guidelines for the Construction, Equipment and Testing of Closed Fuel Oil Overflow Systems Edition 2008

The following Guidelines come into force on September 1 st, 2008 Alterations to the preceding Edition are marked by beams at the text margin. Germanischer Lloyd Aktiengesellschaft Head Office Vorsetzen 35, 20459 Hamburg, Germany Phone: +49 40 36149-0 Fax: +49 40 36149-200 headoffice@gl-group.com www.gl-group.com "General Terms and Conditions" of the respective latest edition will be applicable (see Rules for Classification and Construction, I - Ship Technology, Part 0 - Classification and Surveys). Reproduction by printing or photostatic means is only permissible with the consent of Germanischer Lloyd Aktiengesellschaft. Published by: Germanischer Lloyd Aktiengesellschaft, Hamburg Printed by: Gebrüder Braasch GmbH, Hamburg

VI - Part 3 Table of Contents Chapter 6 Page 3 Table of Contents Section 1 Construction, Equipment and Testing of Closed Fuel Oil Overflow Systems A. General... 1-1 B. Construction and Equipment of the Systems... 1-4 C. Testing... 1-5 Annex A Calculation of the Overflow ne

VI - Part 3 Section 1 A Construction, Equipment and Testing of Closed Fuel Oil Overflow Systems Chapter 6 Page 1 1 Section 1 Construction, Equipment and Testing of Closed Fuel Oil Overflow Systems A. General The construction, equipment and testing of closed fuel oil overflow systems shall be in accordance with these Guidelines. 1. Other rules Beside of these Guidelines the following GL Rules I Ship Technology, Part 1 Seagoing Ships apply also: Chapter 1 Hull Structures, Section 12 Chapter 2 Machinery Installations, Section 10 and 11 Chapter 3 Electrical Installations 2. Definition of designations 2.1 Closed overflow system A closed overflow system is a system which is so constructed and equipped that during fuel oil bunkering the permitted design pressure of the storage tanks cannot be exceeded. A closed overflow system consists of all pipe lines (bunker lines, overflow pipeline, transfer lines of the tanks), storage tanks and overflow tanks together with their associated valves and fittings as well as all control and measuring devices. 2.2 Overflow pipeline The overflow pipeline (overflow main and branches) is the part of the closed overflow system through which the fuel oil is led to the overflow tank. The overflow pipeline may be arranged before or after the storage tanks. 2.3 Design pressure The design pressure for the storage tanks is the test pressure height according to GL Rules I Ship Technology, Part 1 Seagoing Ships, Chapter 1 Hull Structures, Section 12. For overflow systems according to 3.1 the dynamic pressure losses are to be considered in addition. 2.4 Bunker station The bunker station is the location from where the bunkering operation is centrally monitored and controlled. 3. Grouping of closed fuel oil overflow systems Within the scope of these Guidelines closed fuel oil systems are subdivided into three groups. 3.1 Systems of group I Systems of group I (Fig. 1.1) are systems having monitoring devices whereby excess pressure in the storage tanks is prevented by reduction of the bunker rate. Overflow is effected by means of an overflow line between storage tank and overflow tank. 3.1.1 The storage tanks may be filled only to a maximum level defined by the shipyard with the maximum designed bunker rate. 3.1.2 On reaching of the maximum level, the tanks are finally filled by the calculated topping-up rate. The maximum permitted topping-up rate is to be monitored by the flow meter. If the flow meter shall be dispensed with (with owners confirmation), the maximum permitted topping-up rate shall be reduced down to 2/3 of calculated topping-up rate. 3.1.3 If the overflow line is constructed for the designed bunker rate, the requirements according to 3.1.1 and 3.1.2 may be dispensed with. 3.2 Systems of group II Systems of group II (Fig. 1.2) are systems having pressure limiting devices 1 whereby pressures in excess of the tank design pressure are prevented by means of an intermediate overflow valve. Overflow is effected by means of an overflow line and overflow valve between bunker line and overflow tank. 3.2.1 The overflow valve may be direct acting or be controlled by auxiliary energy. 3.2.2 Each storage tank is to be fitted with two independently actuating limit switches. 3.2.3 The storage tank may be filled by the maximum designed bunker rate up to the first level (limit switch slowdown). Topping-up of the tanks is to be carried out at a reduced bunker rate. 1 Overflow valves or other suitable devices can be applied as pressure limiting devices. In the following the designation overflow valves is used.

Chapter 6 Page 1 2 Section 1 A Construction, Equipment and Testing of Closed Fuel Oil Overflow Systems VI - Part 3 Vent Bunker station Main deck Deeptank Deeptank D.B. tank G D.B. tank G G G Manometer Flow meter Overflow tank LA Thermometer Filter G Level indicator Level switch Shut-off valve LA Level alarm Fig. 1.1 Fuel oil overflow system of group I Vent Bunker station Main deck Deeptank Deeptank D.B. tank D.B. tank Manometer Level indicator Overflow tank LA Shut-off valve Overflow valve mit switch, slowdown Max. limit switch Thermometer LA Level alarm Filter Fig. 1.2 Fuel oil overflow system of group II

VI - Part 3 Section 1 A Construction, Equipment and Testing of Closed Fuel Oil Overflow Systems Chapter 6 Page 1 3 3.2.4 The maximum permitted filling level of each storage tank is monitored by a second limit switch (max. alarm). With this alarm/signal the tank filling valve shall be closed. 3.2.5 If overflow valves are controlled by auxiliary energy they will be opened by the limit switch max. alarm when the maximum permitted filling level is exceeded. 3.3 Systems of group III Systems of group III (Fig. 1.3) are systems equipped with pressure limiting devices and automatic control of the tank valves, whereby pressures in excess of the design pressures of the storage tanks are prevented by automatic limitation of the filling levels. Overflow is effected by an overflow line and overflow valve between bunker line and overflow tank. 3.3.1 Each storage tank is to be equipped with two independently actuating limit switches by which control of the tank inlet valves and the overflow valve is effected. 3.3.2 The storage tanks may be filled with the maximum designed bunker rate up to the first limit level (limit switch slowdown alarm). By actuation of the limit switch slowdown alarm, the filling valve of the tank concerned is closed and locked. When the last tank to be filled has reached that limit level, the overflow valve is opened simultaneously. Fuel oil bunkering shall be stopped. 3.3.3 The system shall be switched to topping-up operation. This effects closing of the overflow valve and opening of the inlet valves of the tanks to be filled-up. The storage tanks can then be further filled by the topping-up rate. By means of the second limit switch (max. alarm) the filling valves of the individual tanks are closed and locked. When the last tank has reached that level, the overflow valve is opened simultaneously. Bunker / topping-up operation has to be stopped. 3.3.4 On completion of fuel oil bunkering the overflow system may be switched to normal operation. Now the tank valves are unlocked, the overflow valve is closed and the limit switches are inactive. 3.3.5 Filling valves of storage tanks which are not to be filled, are to be closed and locked prior to fuel oil bunkering and the corresponding limit switches are to be switched to the position inactive. Vent Bunker station Main deck Deeptank Deeptank D.B. tank D.B. tank Manometer Level indicator Overflow tank LA Remote-controlled shut-off valve Overflow valve, controlled by aux. energy LA mit switch, slowdown Max. limit switch Level alarm Thermometer Filter Fig. 1.3 Fuel oil overflow system of group III

Chapter 6 Page 1 4 Section 1 B Construction, Equipment and Testing of Closed Fuel Oil Overflow Systems VI - Part 3 4. Documents for approval The following documents are to be submitted to GL in triplicate for approval. 4.1 For systems of groups I. II and III tank plan of the storage tanks including tank design pressures schematic drawing of the overflow system pressure loss calculation for the overflow pipeline technical data on level indicating arrangement and limit switches list of pipes and valves electrical wiring diagrams bunkering instructions 4.2 Additionally for systems of group I dimensioned isometric drawing of the overflow pipeline technical data of the flow meter 4.3 Additionally for systems of group II technical data of the overflow valves in the case of using direct acting overflow valves: Dimensioned isometric drawing of bunker line, overflow pipeline and transfer lines as well as a pressure loss calculation for the filling lines of the tanks up to the overflow valve. 4.4 Additionally for systems of group III technical data of the overflow valves and the remote controlled tank valves and their wiring diagrams B. Construction and Equipment of the Systems 1. Systems of group I 1.1 Construction 1.1.1 It is to be proved by calculation that the total resistance through the overflow line does not exceed the design pressure of the tanks connected to the system during overflow, taking the topping-up rate into consideration. The calculation of the overflow line is to be carried out for the proposed topping-up rate according to Annex A. 1.1.2 The level limits in the tanks are to be so arranged that the remaining volume between the level switch and tank top is sufficient to take up the volume until the bunker rate is reduced. 2 1.2 Equipment 1.2.1 Bunker line The bunker line is to be fitted with filter, pressure gauge, thermometer and flow meter. 3 1.2.2 Storage tanks The storage tanks are to be fitted with level indicating arrangements. Each tank is to be provided with an independent limit switch. 1.2.3 Overflow line The overflow line is to be provided with heat tracing and insulation, if necessary. 1.2.4 Bunker station The following equipment shall be arranged in the bunker station: remote level indicators and level alarms of the storage tanks end position indicators for remote controlled tank valves, if provided indicator of the flow meter, if provided level alarm of the overflow tank bunkering instructions 2. Systems of group II 2.1 Construction 2.1.1 The overflow line is to be so designed as to allow overflow of the maximum permitted bunker rate to the overflow tank with opened overflow valve without excess pressure increase in the tanks. 2.1.2 The set pressure of direct acting overflow valves is to be determined as follows: p o = (H 1 - H 2 ) g ρ w [N/m²] p o = set pressure of the overflow valve [N/m²] H 1 = height of test pressure of the tanks above base [m] H 2 = fitting position of the overflow valve above base [m] g = acceleration due to gravity [m/s²] = density of water [kg/m³] ρ w 2 For guidance, a period of approximately 5 minutes can be assumed for the time needed until the bunker rate is reduced down to topping rate. 3 Without flow meter, the maximum permitted topping-up rate shall be reduced down 2/3 of maximum calculated topping-up rate. See also A.3.1.2

VI - Part 3 Section 1 C Construction, Equipment and Testing of Closed Fuel Oil Overflow Systems Chapter 6 Page 1 5 If the tanks have been designed for different test pressure values, the lowest pressure value is to be set for H 1. 2.1.3 Overflow valves with auxiliary energy shall open automatically at failure of energy supply and be equipped with means for manual operation. 2.1.4 When using overflow valves with auxiliary energy, the limit switch (max. alarm) is to be so adjusted that the overflow valve will open before the design pressure of the particular tank is reached. 2.2 Equipment 2.2.1 Bunker line The bunker line is to be fitted with filter, pressure gauge and thermometer. 2.2.2 Storage tanks The storage tanks are to be fitted with level indicating arrangements. Two independent actuating limit switches are to be installed in each tank. 2.2.3 Overflow line The overflow line is to be provided with an overflow valve. 2.2.4 Bunker station The following equipment is to be arranged in the bunker station: remote level indicators and level alarms of the storage tanks end position indicators for remote controlled tank valves, if provided level alarm of the overflow tank pressure gauge for the bunker line if a direct acting overflow valve is arranged end position indicator for the overflow valve bunkering instructions 3.1.3 The overflow line is to be so designed as to allow the maximum permitted bunker rate to be discharged to the overflow tank with open overflow valve without excess pressure increase in the tanks. 3.1.4 The air pipes of the storage tanks are to be dimensioned and arranged as to avoid any pressure increasing which may affect the measuring. 3.2 Equipment 3.2.1 Bunker line The bunker line is to be fitted with filter, pressure gauge and thermometer. 3.2.2 Storage tanks The storage tanks are to be fitted with level indicating arrangements. Two independently actuating limit switches are to be installed in each tank. 3.2.3 Overflow line The overflow line is to be provided with an overflow valve. 3.2.4 Bunker station The following equipment is to be arranged in the bunker station: remote level indicators and level alarms for the storage tanks end position indicators for remote controlled tank valves and overflow valves level alarm for the overflow tank bunkering instructions 4. Overflow tanks Overflow tanks are to be so dimensioned that they can take up the volume flow entered until bunkering is stopped. Overflow tanks are to be equipped with level alarms at approximate 1/3 full. 3. Systems of group III 3.1 Construction 3.1.1 The filling limit levels are to be determined by consideration of bunker rate and topping-up rate respectively, volume and shape of tanks, closing time of the tank inlet valves of the tanks as well as opening time of the overflow valve 4. 3.1.2 Overflow valves with auxiliary energy shall open automatically at power failure and be fitted with means for manual operation. 4 Guidance for the limit levels in the tanks: mit level 1: approximate 80 ~ 90 % filling level; mit level 2: approximate 95 ~ 98 % filling level C. Testing 1. Initial operation of the system 1.1 After completion and prior to the first operation every fuel oil overflow system is to be tested. The following equipment and instruments are to be tested and adjusted: safety devices pressure indicators and their drives alarm and locking devices indicating and measuring instruments 1.2 A GL Surveyor is to be present during the first operation of the system.

VI - Part 3 Annex A Calculation of the Overflow ne Chapter 6 Page A 1 Annex A Calculation of the Overflow ne 1. Formula characters Δp = loss of pressure [Pa] λ = coefficient of pipe friction 1 [-] L = length of the straight pipe [m] d i = inside pipe diameter [m] d a = outside pipe diameter [m] d gl = equivalent pipe diameter [m] w = velocity of flow [m/s] ρ = density [kg/m³] ς = resistance coefficient 2 [-] h geod = geodetic height [m] V = volume flow [m³/s] A = cross section of pipe [m²] A d = cross section of pipe running full U = wetted circumference [m] g = acceleration due to gravity [m/s²] Re = Reynolds number [-] Re kr = critical Reynolds number (2320) ν = kinematic viscosity [m²/s] c = correction factor [-] s = thickness of pipe [mm] Δs = tolerances of wall thickness [mm] 2. Calculation of the overflow line The overflow line is to be so designed that the dynamic and static pressure losses due to flow through the line with the topping-up rate will not exceed the design pressure of the storage tanks. This means that Δp ges = Δp dyn + Δp stat < design pressure 3. Calculation of the pressure losses in the overflow line The calculation of the pressure losses in the overflow line is made in consideration of the following parameters: maximum allowable viscosity of the fuel oil at bunkering density 3 of the fuel oil related to the temperature at bunkering 3.1 Calculation of the dynamical pressure losses The loss of pressure in a pipeline results from the resistance behaviour of the straight pipe lengths and their fittings for changes in direction, cross section and flow as well as from their components (valves, sight glasses) and can be determined as follows: Δp = L ρ 2 λ w for straight pipe length (1) d 2 i ρ 2 Δp = ς w for the fittings (2) 2 From formulae (1) and (2) results the dynamical pressure loss of a pipe section, since: L ρ 2 Δp dyn = Σ λ + Σςn wn (3) dn 2 L λ = resistance coefficient for the straight pipe dn length of inside diameters d 1..d n Σ ς n = sum of the individual resistance coefficients for fittings and components in pipe sections of flow rate w 1.w n 3.2 Correction factor and equivalent diameter The allowable tolerances for pipes given in the standards are to be taken into consideration by means of a correction factor. This can be approximately calculated as follows: 1 In the systems handled in these Guidelines laminar flow (Re < Re kr ) can be assumed 2 The Zeta values needed for the calculation are to be taken from recognized standards or publications 3 In the calculation the density is given with minimum 1000 [kg/m 3 ]

Chapter 6 Page A 2 Annex A Calculation of the Overflow ne VI - Part 3 1 c = Δs d 1 a 1 s di Equation (4) put in equation (3), results in: Δp dyn = L ρ Σ λ + Σ ς dn 2 5 2 n cn wn (4) (5) Where c n are the correction values for d 1.d n pipe diameters. Equation (1) also applies to non-circular cross sections if instead of the inside diameter d i the equivalent diameter d gl is put in: 4 A d gl = d (6) U 3.2.1 Pressure losses for pipes connected in parallel If two or more overflow pipe lines are lead from a storage tank to the collecting manifold, the following applies: same pressure loss: Δp dyn = const. single volume flows add up to the total volume flow V = V 1 + V 2 +. V n The solution of the individual equations (3) can only be found by iteration, since λ = f(re) and Re = f(w). 3.2.2 Pressure losses for pipes connected in series Analogous to 2.2.1 the pressure losses for the individual pipes are to be determined according to equation (3). The pressure loss of all pipes results from the sum of all individual pressure losses: Δp dyn = Δp dyn1 + Δp dyn2 + Δp dynn 4. Calculation of statical pressure losses The statical pressure loss results from the geodetic heights of the overflow pipelines, measured between tank top and overflow summit (peak) of the pipes. This is to be determined as follows: Δp stat = h geod g ρ (7)