Hemoglobin Reference Failure Troubleshooting

Similar documents
Quick Reference Guide

CircuFlow Quick Setup Guide

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

Thank you for purchasing your new Empire Reloader B Sound-Activated 3-Speed Paintball Hopper!

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-DPX Operation Manual

DXH Troubleshooting FlowCharts

RAM Operation Manual

36H SERIES Combination Gas Valve

RAM 4021 Operation Manual

TB132. Gas Conversion Kits for NV & NVS Heaters. Issue 1.0 May Applies to models: NV & NVS

Instructions for High Altitude Conversion

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Propane Conversion Kit Instructions

TECHNICAL INSTRUCTIONS

Conversion instructions from natural gas to propane

Contacts. Quick Start Guide

SERVICE MANUAL SALAMANDER BROILERS RADIANT AND INFRARED 36RB 36IRB VULCAN C36RB C36IRB WOLF

Installation Instructions

Chromat Calibration Updated October 27th, 2017

Equipment Operating Procedure Glove Box

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

SPECIFICATIONS ATTENTION

Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale

GAS KITS & ACCESSORIES 504,986M 11/2004 HIGH ALTITUDE KIT

AQUADEX FLEXFLOW SYSTEM QUICK REFERENCE GUIDE

Instructions for Use

SPECIFICATIONS CAPACITY

LNVx Gas Conversion Kit Instructions

Quick Start Guide. A. Hardware installation B. Software installation C. Start the software for the first time D. Do your first measurement

ACCESSORY KIT INSTALLATION MANUAL

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

Model: 43T. Bermad Pressure Relief Valve

MEGR-1912 Instruction Manual

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting

Indications for Use: Caution: Note:

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

Model 130M Pneumatic Controller

UsER manual for Watersens ph -REDOX

Hertfordshire Girls Football Partnership League Promoting the development of girl s football in Hertfordshire

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

HemoCue Hb Procedure Template

MASSACHUSETTS STATE POLICE CRIME LABORATORY. Certificate of Calibration Procedure for the Alcotest 9510

ISE-730 Oxygen Electrode and DO2-100 Currentto-Voltage

MJB4 Mask Aligner Operating Procedure. Effective Date: 07/12/2012 Author(s): Jiong Hua Phone:

DS05C,D,G Dial Set Pressure Regulating Valves

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

RC 195 Receiver-Controller

Department of Laboratories St. Louis, MO ISSUE DATE: June 2007 REVISION DATE: July 2010 REVIEWED DATE: May 2017 PRINCIPILE:

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

SILENTAIRE TECHNOLOGY

Read this first. Zetasizer nano series Self installation and Quick start guide MRK825-02

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Gas Conversion Kits CERAMIC HEATER SERIES (1, 2, 3, 4 Burner Units)

RG1200 Service and Repair Manual

Natural Gas Conversion Kit

HORNE 20 THERMOSTATIC MIXING VALVE TYPE H-2003

D05 Pressure Regulating Valves

SPECIFICATIONS APCEPH1

SL G3 - Fuel Conversion to Natural Gas (LP to NG) P-Kit 301

Bristol Fire Department Standard Operating Procedures. Multi Gas Detector

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Tru Flight TRUFLIGHT INSTALLATION GUIDE TRUGOLF.COM

Installation & User Guide. English Version 1.0

SILENTAIRE TECHNOLOGY

Vapor Sorption Analyzer

installation instructions

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

CONSUMER MODEL INSTALLATION GUIDE

Maintenance and Repair. AirHawk II Air Mask. Second Stage Regulator. Order No.: /02 Prnt. Spec (I) MSAsafety.

A few seconds after turning on, the screen changes to Set Up Screen Before adjusting the pressure, calibrate the O 2 sensors

Installation Instructions

SPECIFICATIONS. Normally closed automatic shutoff valve with proof of closure. Fast opening, fast closing. ATTENTION

Introduction to Chlorosense

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

PointsPlus U S E R G U I D E

MAINTENANCE PROCEDURE FOR X 650

Powers Controls RC 195 Single Input Receiver-Controller

Installation of Your SprayMaster System

64 Series Pressure Reducing Regulators

CSA Sample Draw Aspirator Adapter Operator s Manual

Installation Instructions

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Hydraulic Punch Drivers

V43 Pressure Actuated Water Regulating Valve

Installation Troubleshooting Maintenance Instructions Installation / Start-up

O2100C Oxygen Measurement Module Technical Use Notes do not use other wall adapters with the O2100Cmodule. 10% / V 5% / V 2% / V 1% / V 10% / V

Gas Conversion Kit Pilot Ignition Heaters

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Transcription:

Hemoglobin Reference Failure Troubleshooting The HEMOGLOBIN REFERENCE FAILURE error ( HGB REF FAILURE ) is generated by the Vet ABC as a quality control check for hemoglobin measurement. Recall that the analyzer measures hemoglobin by first lysing the red blood cells in the sample, then converting the hemoglobin that is released into a lightabsorbing compound. The amount of light absorbed by this compound is proportional to the quantity of hemoglobin that is present. To ensure that this measurement is performed accurately, the Vet ABC-Diff first determines the amount of light absorbed by the reagents alone, before any blood is added, and this absorbance is factored out of the patient determination. This is referred to as blanking the reagents. The instrument determines this blank value before each patient sample and compares the reading to the previous blank as a quality control check. If the current and previous readings are significantly different, the instrument places an exclamation point beside the HGB result. The ABC also determines the blank value as part of the Startup cycle, and if this blank is significantly different from the previous run, the HGB REFERENCE FAILURE message appears. In summary, then, two conditions must exist for the hemoglobin blanking procedure to proceed correctly. Reagent must be present in the measuring chamber, and the photometer (i.e. the light detecting mechanism) must be functioning properly. Troubleshooting a Hgb Reference Failure, therefore, should be as follows: 1) Open the door of the ABC run a Startup cycle, watching the mixing and RBC chambers as the cycle progresses. Do the chambers fill with fluid at any point in the cycle? If not, this is probably the cause of the failure. Determine the cause as follows: A) Was this pack recently installed? If so, were the red plugs removed prior to inserting the pack? B) The pack may not be not seated well - burp the pack, remove, and reseat C) If the red plugs were still attached, or the pack wasn t seated well, the instrument may have drawn a sizeable quantity of air into the system while attempting to pass Startup. Run several Prime cycles (SERVICE REAGENT PACK PRIME) and watch for fluid to appear in the chambers. If reagent appears, run a

Startup cycle. If the failure still occurs, 2 3 more Primes may be needed to remove air bubbles from the chamber. D) If fluid still does not appear, remove the pack and hold the bottom end over a sink. Insert a pen or hemostat into each of the three ports and watch for reagent to flow out. If no reagent is present, the pack has been used up or the pack is defective. Determine which is the cause we will replace a defective pack free of charge. E) Install a new pack using the Change Pack program, then run a Startup cycle, watching for reagent to enter the chambers. 2) If reagent is entering the chambers, and the HGB Reference Failure is still occurring, the photometer may need to be adjusted. The following procedure explains how to make this adjustment. Note that reagent must be present in the WBC/HGB chamber before making this adjustment. Do not attempt to adjust the photometer without ensuring the reagent is flowing properly! IMPORTANT NOTES If the analyzer has been turned off, switch it on and allow it to warm up for at least 30 minutes before adjusting the photometer. Also, perform a concentrated cleaning to remove any debris that may have accumulated on the photometer (Note that this does not apply to new instrument installations). You will also need the following tools: 1. Silver key to open front cover (in accessories kit) 2. Orange handled screwdriver (in accessories kit) 3. Very small flat-head screwdriver (size 1.4 to 2.9 m/m)

ADJUSTMENT PROCEDURE 1. To reach the photometer adjustment screw, you will need to take the top cover off the analyzer. Place the silver key in the black rubber door latch on the left side of the instrument and turn until the door opens. 2. Unscrew the 5 cover fixation screws. There is one below the rubber door latch, two on the back of the instrument at the far right top and bottom, and two at the top of the reagent compartment (see diagrams on next page). Do not completely unscrew the two above the reagent compartment. They are easily dropped into the interior of the analyzer. Remove the three screws on the back of the analyzer, then loosen the final two just enough to remove the cover panel. 3. Lift off the instrument cover. Look into the interior of the instrument and locate the green circuit board attached to the back of the analyzer. 4. Refer to the circuit board diagram on the next page and locate adjustment block #R97 in the top right hand corner (circled). Then examine the circuit board in the analyzer and locate the same block. The block is a blue, horizontally-oriented rectangle with the number R97 printed on the circuit board adjacent to the block. Note the small screw in the lower right corner of the block. When instructed in Step #6, you will use the small flat-head screwdriver to turn this screw.

5. Now go into the analyzer s Technician menu to adjust the photometer to the proper setting. From the Main Menu, perform the following steps: a. Cursor to 4) SERVICE and press ENTER b. Cursor to 8) TECHNICIAN and press ENTER c. At the PASSWORD prompt, type in the numbers 421 and press ENTER d. Cursor to 2) ADJUSTMENTS and press ENTER e. Cursor to 1) CAL PHOTOMETER and press ENTER

NOTE: DO NOT CHANGE ANY OTHER SETTINGS IN THE TECHNICIAN MENU!!! This menu contains adjustments that, if altered, will dramatically affect the performance of your analyzer. If there are any questions or concerns about performing this procedure correctly, please phone 1-866-382-6937. 6. In about 30 seconds, a number will appear on the screen. This is the current setting for the hemoglobin photometer and, when properly adjusted, is usually around 237. While the number is displayed on the screen, turn the screw on the R97 block until the number 237 or 238 is displayed. Turn the screw clockwise to increase the number and counterclockwise to decrease the number. Several revolutions of the screw may be necessary. If the number disappears before the adjustment is completed, perform steps 5 and 6 again until the photometer is set correctly. 7. Now run a STARTUP cycle by pressing the yellow STARTUP button on the face of the analyzer. If STARTUP fails or the HEMOGLOBIN REFERENCE FAILURE error appears, run the STARTUP cycle a second time. If the error still occurs, phone Vet NovationsTechnical Support for assistance (1-866-382-6937). 8. If STARTUP passes, replace the analyzer cover. Run the level of control that you are currently using and verify that the analyzer is recovering all values correctly. If the control is within specified limits, the instrument is ready to run patient samples.