Ceiling System. Installation Instructions Curvatura 2 x 2

Similar documents
Installation Instructions Topo Ceiling System

Domed Ceilings and Barrel Vaults

USG Ceiling Solutions. LOGIX Integrated Ceiling Systems INSTALLATION GUIDE

USG Ceiling Solutions USG DONN ADVANCESPAN, DXAS AND DXTAS CORRIDOR ACOUSTICAL SUSPENSION SYSTEM INSTALLATION GUIDE

USG Ceiling Solutions USG DONN ADVANCESPAN, DXAS AND DXTAS CORRIDOR ACOUSTICAL SUSPENSION SYSTEM INSTALLATION GUIDE

USG EXTERIOR CEILING SYSTEMS

CLEANROOM GEL GRID CEILING SYSTEM PRODUCT DATA Division

INSTALLATION & OPERATION MANUAL AORCS ATLAS OPERATING ROOM CEILING SYSTEM. Redefine your comfort zone.

rondo aluminium components

GRAVITY BIKE RACK ASSEMBLY & OPERATING INSTRUCTIONS

Assembly Instructions. -Cantilever Boat Lifts

CONFER ABOVE GROUND CURVE STEP / ABOVE GROUND CURVE STEP SYSTEM ASSEMBLY AND INSTALLATION MANUAL

MODEL CCX-AG CURVE STEP / CURVE STEP SYSTEM

Grow to Pro Basketball

INSTALLATION INSTRUCTIONS AT-SERIES ANCHOR ASSEMBLY PART NUMBER: F-04CAJP 450 LB. [204kg] MAXIMUM CAPACITY (PRO POOL LIFT)

- Written price quotations are valid for 30 days from the date of the quote unless otherwise noted.

CONFER IN-GROUND CURVE STEP / IN-GROUND CURVE STEP SYSTEM ASSEMBLY AND INSTALLATION MANUAL

VOLLEYBALL SPIKE TRAINER. Assembly Instructions. Owner s Manual. Model # VST-100. Club Volleyball Gear WARNING

CamRT Sun Top Bimini Installation Instructions

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

SAVE THESE INSTRUCTIONS DEALER/INSTALLER: GIVE TO HOMEOWNER OCEAN BLUE ABOVE GROUND POOL LADDERS

Remington 700. Disclaimer Limited Warranty Satisfaction Guarantee Installation Instructions

User s Manual. Model SWTC800. CAUTION: Adult Assembly Required

IMPORTANT: RECEIVING INSTRUCTIONS:

SASK-A-POLE OWNERS AND USERS MANUAL

Troyer s Gourd Rack 8 unit F R H O P

SailTrack Installation Instructions. External Track

3190A NEO-ANGLE DOOR INSTALLATION INSTRUCTIONS. Series MODEL NO

EOS LED Pendant Mounted Luminaire

Inflatable Stand Up Paddle Board Manual

Plans and Instructions to build a folding reflector oven

Model 6812C Dual Lane Scoreboard Owner s Manual

9) BOM DOES NOT ACCOUNT FOR THE USE OF SCRAP OR EXCESS MATERIAL CUT FROM OTHER ITEMS.

VERTICAL SURFBOARD CARRIER READ ME! IMPORTANT WARNING!

Cat Fence Installation Instructions for Regular and Snow Protection Kits with Extra Posts. List of items shown

3 Scotch-Weld Polyurethane Reactive Adhesive Applicator Replacement Part Installation Guide

SailTrack Installation Instructions. CMPE Track

CADDY SPEED LINK MANUAL SLK LOCKING DEVICE

F-1279-R UPPER RIGHT SKIN F-1280-R RIGHT SIDE SKIN F-1281-R LOWER RIGHT SKIN F-1208-R FUSELAGE FRAME

Basic Install Guide. Parts: 1 P a g e

ORNAMENTAL CANTILEVER GATE INSTRUCTIONS

Sunrise Fountain Water Wonders Assembly & Mounting Instructions

8MAY15 US RACK, Inc Falcon Drive, Madera, CA

SECTION 23iS/U: SIDE SKINS

Standard Collection Setup Manual

USER MANUAL. DM65 Manual Flush/Tilt Combo Mount

X-6 STRINGING MACHINE OWNER'S MANUAL. Issue 1 - May Copyright 2004 GAMMA Sports - All Rights Reserved

BARRIER OFFSET 0" A 6" 6" A 12" 12" A 26" A 26" 3A OR 4A L OR S * ** L OR S L OR S

602 STRINGING MACHINE OWNER'S MANUAL

STATIONARY TRUCK INTERNAL HALYARD CAM CLEAT FLAGPOLES FOR QUICK AND PROFESSIONAL COMMERCIAL INSTALLATION READ ALL INSTRUCTIONS BEFORE PROCEEDING

0 1,150 1/

-- SGP (NOVA TEAM SQUARE)

Installation Instructions

H-950 SHRINKFAST HEAT GUN #998

features and benefits:

SUP Owner s Manual.

STATIONARY TRUCK INTERNAL HALYARD V-CLEAT FLAGPOLES FOR QUICK AND PROFESSIONAL INSTALLATION READ ALL INSTRUCTIONS BEFORE PROCEEDING

COOPER POWER SERIES. 50 A 2:1 series multiple (dual voltage) switch cap/wrench, lever or hotstick operable handles installation instructions

SECTION 10iS: TAILCONE

600 / 600FC OWNER'S MANUAL

Grandpa's Homemade Rocket for About a Dollar!

Permanent Roof Anchors

3/4 SafeClaw Anchorage Connectors

Installation Guide, MPower Echelon Console

Installation Instructions MODEL VSTI-A020 Tank Indicator Installation Model: VSTI-A020, Stainless Reverse Read System Versa Steel Inc. Guide Cables No

Round pool 52 (1,32m)

Installation and Operating Instructions

CLIMBING STEEL POLES INSTRUCTOR GENERAL LESSON OUTLINE ONLINE/CLASSROOM SESSION

Falcon 3 145, 170, 195 and Tandem Owner / Service Manual

NEXT GENERATION FLEX FENCE

Standard Model Coolers, Freezers and Combination Cooler/Freezers In Stock for SAME DAY SHIPMENT

SPOOLER INSTRUCTIONS. STEP 12 If you are going to paint your posts, that should be done at this time.

Installation of 2 Tier In Line Greeting Card Rack

Adapter Kit 5WAR RA NT Y. For use with EZ-Up Gravity Boots and select Teeter Inversion Tables* NEW! Assembly Instructions FULL YEAR

1 SafeClaw Anchorage Connectors

RUDDER KIT INSTRUCTIONS

Universal Elevator Mount Owners Manual Customer Service Center N53 W24700 South Corporate Circle Sussex, WI U.S.A.

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

ASSEMBLY INSTRUCTIONS

Pressure Balance Trim

A Foundation Of Trust. Hanging By A Thread

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware


Read through all the steps first before working on the camera. Make sure you know what to do.

Field Manual. Simple by Design

Deluxe Gourd Racks I D E G A. Parts List. Shown above are parts for the two-level, Deluxe Gourd Rack (DGR 12V)with 12 arms for vertically hung gourds.

THOR 10 HAMMER CAGE INSTRUCTIONS

3 Post Pressure Fit System Owner s Manual

Consult the architect or other responsible persons regarding the weight of the overhead structure that is to be supported.

WARNING: Gas Conversion Kit Instructions Applies to: Model UDAP, UDAS, UDBP, and UDBS Unit Heaters. General and Warnings FOR YOUR SAFETY

New Product. featuring an exclusive dual directional head* Innovative Fastening Technologies. From the makers of. * Patent-pending design.

FITNESS, SAFETY & MEDICAL SUPPLIES

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

Portable Soccer Goal Safety Program

The second stage cannot begin until the first stage is complete.

3M Liqui-Cel EXF-10x28 Series Membrane Contactor with ANSI or JIS Connections with Integrated End Caps

dividers (Converted)-1 12/2/05 10:05 AM Page 5 Donn Ceil Ceil Donn

Stevenson Projects Building the Hull Top Deck and Bulkheads

Airwalker. Installation and Safety Information. Stretch Products for Dance, Therapy, Education, and Fitness

Pressure Dump Valve Service Kit for Series 2300 Units

Transcription:

Curvatura 2 x 2 Page 1 of 8 Before beginning installation of the CURVATURA 2 x 2, check the enclosed bill of materials to ensure that all parts are present and undamaged. Read all installation instructions and familiarize yourself with the system s components. This is extremely important because parts will become permanently damaged if they are installed incorrectly! To help with identification, all parts are poly-bagged and labeled. Parts and May include some or videotape Bill of Materials (BOM) Components all of the following: PART LIST A F A E B D C D E F C B Vault Main Tee Segment Valley Main Tee Segment 2 Cross Tee 2 x 2 Infill Panels 23 3 /4" 23 3 /4" Main Tee Splice Plate Wall Attachment Clip Integral Hold-Down Tabs 18 Gauge Stainless Steel Wire Splice Cover Corner Cap

Page 2 of 8 Step 1: Laying Out First Row of Main Tees 1. A. 1. B. 1. C. Refer to the Bill of Materials and Ribbon Drawing and locate the appropriate Flush Cut Main Tee to start the first row of Main Tees. Note that Main Tees can have two different types of ends flush-cut ends and splice ends. A Main Tee with a flush-cut end will have a cross tee slot approximately 1/2-inch from its factory-cut end. 1. D. 1. E. 1. F. A part ID code is stamped on Main Tees with splice ends. For your reference, these ID codes are also listed on the Ribbon Drawing. A Main Tee with a splice end will have a slot for the splice approximately 1 inch from its end. Find a corner starting point based on locations specified on your architect s plans or by scaling from a working drawing. It s best to start at a point near a wall or column that can be used for reference and support. 1. G. 1. H. I. Lay the Main Tees out on the ground as they will be arranged in the installation. Be sure to place a Flush-Cut Main Tee at the beginning or end of this first row, as shown on the Ribbon Drawing.

Page 3 of 8 Step 2: of Main Tees A. B. C. Each Main Tee has pre-punched hanger holes spaced about 2 feet apart. Hanger wires need only be attached at every other hole, so mark these locations when laying your arrangement out on the floor. D. Once you have established where each hanger wire should go, you can pre-hang the first row of hanger wire. Because the tees are curved, the space between hanger wires will vary. E. Hang the flush-cut end of the Main Tee from the ceiling based on the elevation and location specified on your architect s plans or by scaling from a working drawing. F. Extra hanger holes can be field-punched or drilled where required to help work around obstructions. Keep in mind that the space between any two hanger wires must not exceed 4 feet. Some field installation may require you to make a flush-cut Main Tee by fieldcutting a main tee with a splice end. To do this, find the Cross Tee slot closest to the point wherre the Main Tee will be cut. G. H. I. Insert the Cross Tee into that location and mark where the outside edge of the Cross Tee meets the Main Tee. Use a square to ensure that the mark, and therefore the cut, will be straight and square. Carefully cut the Main Tee with tin snips, ensuring that the final cut has a finished look.

Page 4 of 8 Step 2: of Main Tees J. K. L. The finished field-cut Main Tee with the cross Tee installed should look like this. Continue installing Main Tee segments. Refer to the Ribbon Drawing to select each tee. To connect Main Tees, use a Main Tee Splice. Insert the splice tabs into the slots at the ends of the adjoining Main Tees. Then, partially bend the tabs inward. M. N. O. Once both tees are suspended and aligned, the tabs can be fully bent down. The accuracy of the first row of Main Tees will ultimately determine the quality of the installation so be sure to check the integrity of the completed row. Extra care at this point will prevent alignment problems in the rest of the installation. Next, examine the profile of the completed row from the side. The curve of one tee should flow smoothly into the curve of the next. If the curves are not flowing smoothly, adjust the hanger elevations either up or down. P. Q. R. Wire should hang straight and plumb within 1 in 6, about 10 degrees. If hangers need to be relocated, move them now. If necessary, you can punch or drill extra hanger holes into the Main Tee to ensure plumb wires. Now, examine the completed row of Main Tees from one end. It should be straight and plumb. If you need to install additional hanger wires, install them now. It s important that the first row of Main Tees remains stable during the entire process. As a final step, install temporary bracing to the ceiling or walls, as each row is completed to ensure that it remains straight and rigid.

Page 5 of 8 Step 3: Install Remaining Grid A. B. C. Using the first row of hanger wires as a guide, install each additional row of hanger wire two feet apart. Use string lines or a laser to ensure that each row will be properly aligned. After hanging the first Flush-Cut Main Tee in a row, connect it to the previous row with a Cross Tee. D. E. F. Continue hanging Main Tees and joining them with Cross Tees to form the grid. When all Main Tees have been hung, tightly wrap the ends of each hanger wire. This is important because the ends of these wires could be seen from the side of the completed installation. H. I. J.

Step 4: Panel Page 6 of 8 A. B. C. Lay CURVATURA 2 x2 panels into the grid one at a time. Some panels are directional; check for directional markings and install accordingly. On DIAMONDFLEX panels, look for the notch in the panel corner that indicates directionality. D. E. After each panel has been installed, bend the Hold-Down Tabs as necessary to secure the panel, eliminating all gaps between the panels and grid. Be careful not to overbend the tabs as this could damage the panel. After installing each panel, be sure that sufficient Hold-Down Tabs have been bent to prevent the panel from lifting. Adjusting tabs later will be difficult. 1. 1. 1.

Page 7 of 8 Step 4: Edge Trim A. B. C. Remove any temporary bracing. Next, follow the Ribbon Diagram to identify the proper position for each Edge Trim segment. Install the Edge Trim by sliding each trim segment onto to the grid. For ease of installation, Edge Trim segments are designed to be about 1/2-inch shorter than the Main Tee segments. D. E. F. Fascia Splices and Corner Clips are provided to cover the gaps. To install each Fascia Splice, squeeze the bottom tab to allow a snug fit around the trim. Hook the tab over the bottom edge of the trim. Then, bend over the top of the splice as shown here. It s easiest to install Fascia Splices progressively. G. H. I. Next, apply Corner Caps. Hook each Corner Cap over the bottom edge of the trim, then bend over the top as shown here. Squeeze the trim against the grid to ensure a proper fit. Then, screw-attach the trim segments to the grid with number-six by three-eighths self-tapping screws. Be sure to install at least two screws per trim segment.

Technical Service 800 USG.4YOU Web Site www.usg.com Samples/Literature 888 874.2450 Samples/Literature E-mail samplit@usg.com Samples/Literature/Fax 888 874.2348 Customer Service 800 950.3839 Note All products described here may not be available in all geographic markets and are subject to change without notice. Consult your local sales office or representative for information. Trademarks The following are trademarks of USG Interiors, Inc. or a related company: CURVATURA, DIAMONDFLEX, USG. Notice We shall not be liable for incidental or consequential damages, directly or indirectly sustained, nor for any loss caused by application of these goods not in accordance with current printed instruction or for other than intended use. Our liability is expressly limited to replacement of defective goods. Any claim shall be deemed waived unless made in writing to us within thirty (30) days from the date it was or reasonably should have been discovered. SAFETY FIRST! Follow good safety and industrial hygiene practices during handling and installation of all products and systems. Take necessary precautions and wear appropriate personal protective equipment as needed. Read material safety data sheets and related literature on products before specification and/or installation. Manufactured by USG Interiors, Inc. 125 South Franklin Street Chicago, IL 60606 IC461/7-03 2003, USG Interiors, Inc. Printed in U.S.A.