COOPER POWER SERIES. 600 Ampere Deadbreak Grounded Standoff Bushing 15 & 25 kv and 35 kv Class Installation Instructions. Bushings MN650045EN

Similar documents
COOPER POWER SERIES. 200 A 15, 25, and 35 KV class insulated standoff bushing installation instructions. Loadbreak Apparatus Connectors MN650039EN

COOPER POWER SERIES. 600 A 15, 25, and 35 kv class PUSH-OP bushing adapter cap installation instructions. Deadbreak Apparatus Connectors MN650050EN

COOPER POWER SERIES. 200 A 15, 25, and 35 kv class portable feedthru installation instructions. Loadbreak Apparatus Connectors MN650037EN

COOPER POWER SERIES. Series winding ratio test procedure instructions. Voltage Regulators MN225060EN. 120 Vac VOLTMETER

COOPER POWER SERIES. 600 A 15, 25 and 35 kv class bushing adapter installation instructions. Deadbreak Apparatus Connectors MN650058EN

Effective March 2015 Supersedes S August 2002

COOPER POWER SERIES. EL Bay-O-Net Current-Limiting Fuse Installation Instructions. Fusing Equipment MN132023EN

DT400/436 Tee Connector Installation Instructions

COOPER POWER. SERIES VariSTAR type composite light-duty under-oil (CLU) MOV arrester installation instructions. Surge Arresters MN235023EN

COOPER POWER SERIES. 200 A 15/25 kv class deadbreak straight connector installation instructions. Deadbreak Apparatus Connectors MN650043EN

COOPER POWER SERIES. Manual or Hostick Operable, Padlockable 150 A Tap-Changer Switch Installation Instructions. Tap-Changer Switch MN800015EN

DAI630TB2669 Dead Front Arrester Installation Instruction

COOPER POWER SERIES. UltraSIL Polymer-Housed Distribution-Class MOV Surge Arrester Installation Instructions. Surge Arresters MN235006EN

200 A, 15 and 25 kv class loadbreak bushing insert installation instructions

COOPER POWER SERIES. D-73P3 bypass switches installation instructions. Switches MN008005EN. Effective April 2016 Supersedes S June 2013

COOPER POWER SERIES. QD8 Quik-Drive tap-changer VR or VL reversing switch stationary contact assembly kit number A48 installation instructions

COOPER POWER SERIES. VariSTAR Storm Trapper high energy MOV arrester installation instructions. Surge Arresters MN235017EN

COOPER POWER SERIES. 600 A, 15, 25, and 35 kv Class Cleer Grounding Elbow Installation Instructions. Loadbreak Apparatus Connectors MN650056EN

COOPER POWER SERIES. Under-oil arrester disconnector installation/operation instructions. OEM Equipment MN800010EN

COOPER POWER SERIES. DS250 deadbreak straight connector installation instructions interface A. Connectors MN650027EN

COOPER POWER SERIES. DE250 deadbreak elbow connector installation instructions interface A. Screened Separable Connectors MN650025EN

COOPER POWER SERIES. 200 A 15/25 kv class elbow installation instructions. Deadbreak Apparatus Connectors MN650042EN

COOPER POWER SERIES. 50 A 2:1 series multiple (dual voltage) switch cap/wrench, lever or hotstick operable handles installation instructions

COOPER POWER SERIES. UltraSIL polymer-housed VariSTAR surge arrester IEC for MV systems to 36 kv installation instructions

COOPER POWER SERIES. Operation Counter Replacement Instructions. Reclosers MN280047EN. Effective May 2016 Supersedes S December 2003

Effective May 2017 Supersedes July 2009 (S ) 600 A 35 kv Class T-OP II connector assembly installation instructions 200 A PROTECTIVE CAP LRTP

COOPER POWER. SERIES VariSTAR type AZE station class surge arresters installation and maintenance instructions. Surge Arresters MN235022EN 0.

COOPER POWER SERIES. 200 A 35 kv class LE series elbow installation instructions. Loadbreak Apparatus Connectors MN650010EN

Effective January 2017 Supersedes July 2011 (I ) VariSTAR Type AZG4 Surge Arresters Installation and Maintenance Instructions

COOPER POWER SERIES. 600 A 35 kv class PUSH-OP deadbreak connector installation instructions. Deadbreak Apparatus Connectors MN650052EN

600 A 35 kv class PUSH-OP deadbreak connector installation instructions

COOPER POWER SERIES. 200 A 15 and 25 kv class elbow with optional integral jacket seal installation instructions. Loadbreak Connectors MN650008EN

COOPER POWER SERIES. 200 A 15 and 25 kv class elbow with integral jacket seal* for use on tape and wire shielded cable installation instructions

COOPER POWER SERIES. Types E, 4E, V4E, H, 4H, V4H, L, and V4L single-phase recloser installation and operation instructions. Reclosers MN280051EN

COOPER POWER SERIES. VFI SF6-insulated vacuum fault interrupter installation, operation and maintenance instructions. Switchgear MN285004EN

Installation Instructions for the Walking Beam Interlock for Eaton EHD, FDB, FD, HFD, FDC, FW, HFW, FWC, Circuit Breakers and Molded Case Switches

S Surge Arresters

S Loadbreak Apparatus Connectors WARNING: WARNING:

Effective May 2017 Supersedes August 2005 (S )

Operation Manual Enabling Pole-Top Communication Via the TripSaver II Magnet Tool

Medium voltage standard-duty, heavyduty, and extreme-duty single-phase, unfused capacitor units and accessories

Inspection Recommendations

Pressure Relief Valve Instruction Manual

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

Norrsken Family Booklet

S Surge Arresters. Handling and Storage. Standards. Acceptance and Initial Inspection

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor

SERIES L4E & L6E LADDER EXTENSIONS

COOPER POWER SERIES. Type VFI, Fluid-insulated Switchgear; Installation, Operation and Maintenance Instructions

3M Liqui-Cel EXF-4x13 and 4x28 Series Membrane Contactors

RGC-IR Remote Gas Calibrator for IR400

Accu-Tab Systems 1000 Series by Axiall Corporation

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

Installation Instructions JATCO Environmental Protection Tank Model J-7000

Remington 700. Disclaimer Limited Warranty Satisfaction Guarantee Installation Instructions

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

4-in-1 Professional Inflator Kit

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

FLANGED TWO-PIECE BALL VALVES

60 farm jack. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

Model ASSEMBLY and OPERATING INSTRUCTIONS

Triple Tine Mechanical Grapple

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

Accu-Tab Systems 2000 P Series by Axiall Corporation

Instruction Manual No. 742, 8/98

Nitrogen Supply System

TactAir PCP Fill Kit/Adapter. Operation Manual

Manual. FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator. Where Imagination Meets Innovation

FLANGED TWO-PIECE BALL VALVES

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers

VL PONTOON/TRITOON DECK BRACKET 13 INSTRUCTIONS

Cylinder Tilt Saddle Instruction Manual

INTRODUCTION BILL OF MATERIALS SPECIFICATIONS & TOOLS PROCEDURES OPERATION OF SEATPOST GIANT LIMITED WARRANTY

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE

The Churchill. Chest Clip Guard

Accu-Tab PowerBase 3012AT by Axiall Corporation

Mini Pod Press. #78H-M2 Mini Pod Press Manual-R1

6 digital caliper with case

Cocoa Patio Pond with Lit Spillway

OPERATOR'S & PARTS MANUAL

Operation and Maintenance Manual

Safety switch renewal parts

FRESH AERO OneOP Model RC (Reservoir/tank) Tire Inflating System

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

FLANGED MULTI-PORT BALL VALVES

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

SERVICE LETTER WARRANTY CONDITIONS FOR ROTAX

S Vacuum Switches. Contents. Type VCS-1 Single-Phase Vacuum Capacitor Switch Installation and Operation Instructions

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

FOOSBALL ASSEMBLY, INSTRUCTIONS AND RULES PL

2000 lb manual winch

Permanent Roof Anchors

ELECTRIC OPERATING PROCEDURES Date: 11/01/06

Interface Devices, Inc. Hydraulic Mini Mule

INSTRUCTIONS PARTS LIST

Parts & Operators Manual

Transcription:

Bushings MN650045EN Effective May 2017 Supersedes February 1987 (S600-24-2) COOPER POWER SERIES 600 Ampere Deadbreak Grounded Standoff Bushing 15 & 25 kv and 35 kv Class Installation Instructions

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation s ( Eaton ) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or otherwise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and descriptions contained herein. The information contained in this manual is subject to change without notice. ii

Contents DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY... ii SAFETY FOR LIFE... iv SAFETY INFORMATION... iv Safety instructions...iv PROCEDURE.... 1 Grounded standoff bushing kit...1 Install standoff bushing...1 Assemble...2 iii

600 Ampere Deadbreak Grounded Standoff Bushing 15 & 25 kv and 35 kv Class! SAFETY FOR LIFE Safety for life! SAFETY FOR LIFE Eaton meets or exceeds all applicable industry standards relating to product safety in its Cooper Power series products. We actively promote safe practices in the use and maintenance of our products through our service literature, instructional training programs, and the continuous efforts of all Eaton employees involved in product design, manufacture, marketing, and service. We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high voltage lines and equipment, and support our Safety For Life mission. Safety information The instructions in this manual are not intended as a substitute for proper training or adequate experience in the safe operation of the equipment described. Only competent technicians who are familiar with this equipment should install, operate, and service it. A competent technician has these qualifications: Is thoroughly familiar with these instructions. Is trained in industry-accepted high and low-voltage safe operating practices and procedures. Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment. Is trained in the care and use of protective equipment such as arc flash clothing, safety glasses, face shield, hard hat, rubber gloves, clampstick, hotstick, etc. Following is important safety information. For safe installation and operation of this equipment, be sure to read and understand all cautions and warnings. Hazard Statement Definitions This manual may contain four types of hazard statements: DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in equipment damage only. Safety instructions Following are general caution and warning statements that apply to this equipment. Additional statements, related to specific tasks and procedures, are located throughout the manual. DANGER Hazardous voltage. Contact with hazardous voltage will cause death or severe personal injury. Follow all locally approved safety procedures when working around highand low-voltage lines and equipment. G103.3 Before installing, operating, maintaining, or testing this equipment, carefully read and understand the contents of this manual. Improper operation, handling or maintenance can result in death, severe personal injury, and equipment damage. G101.0 This equipment is not intended to protect human life. Follow all locally approved procedures and safety practices when installing or operating this equipment. Failure to comply can result in death, severe personal injury and equipment damage. G102.1 Power distribution and transmission equipment must be properly selected for the intended application. It must be installed and serviced by competent personnel who have been trained and understand proper safety procedures. These instructions are written for such personnel and are not a substitute for adequate training and experience in safety procedures. Failure to properly select, install or maintain power distribution and transmission equipment can result in death, severe personal injury, and equipment damage. G122.2 iv

600 Ampere Deadbreak Grounded Standoff Bushing 15 & 25 kv and 35 kv Class Procedure Grounded standoff bushing kit Grounded standoff bushing Silicone lubricant Installation instruction sheet Lubricate Protective shipping cap Ground lead Figure 2. Lubricate bushing Figure 1. Assembly kit All associated apparatus must be de-energized during installation or maintenance. CAUTION The 600 A Grounded Standoff Bushings are designed to be operated in accordance with normal safe operating procedures. These instructions are not intended to supersede or replace existing safety and operation procedures. Grounded standoff bushings should be installed and serviced only by personnel familiar with good safety practices and the handling of high-voltage electrical equipment. Clean and lubricate 1. Remove the protective shipping cap from the bushing interface. 2. Clean and lubricate the interface with the lubricant (supplied) or approved equivalent. Install standoff bushing 1. Grasp the eyebolt with the hotstick. 2. Lower the grounded standoff bushing into the parking stand. 3. Turn the eyebolt clockwise until the grounded standoff bushing is secure. 4. Connect the ground lead to the system ground. Hotstick Parking stand Figure 3. Install standoff bushing 1

600 Ampere Deadbreak Grounded Standoff Bushing 15 & 25 kv and 35 kv Class Assemble 1. Disconnect the deadbreak connector from the de-energized apparatus bushing. 2. Use the hotstick to position the deadbreak connector onto the grounded standoff bushing. 3. Turn the deadbreak connector bolt clockwise into the grounded standoff bushing until tightly seated. 4. Cover the de-energized apparatus bushing with an insulated protective cap. 5. When not in use, cover the grounded standoff bushing interface with an insulated protective cap or red shipping cap to keep the interface clean. Deadbreak connector 200 A protective cap 600 A protective cap Figure 4. Assemble bushing 2

600 Ampere Deadbreak Grounded Standoff Bushing 15 & 25 kv and 35 kv Class This page is intentionally left blank. 3

! SAFETY FOR LIFE Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2017 Eaton All Rights Reserved Printed in USA Publication No. MN650045EN May 2017 Eaton is a registered trademark. All trademarks are property of their respective owners. For Eaton s Cooper Power series product information call 1-877-277-4636 or visit: www.eaton.com/cooperpowerseries.