Unifrost NV/SA and Air Products

Similar documents
Active Fire Prevention by Oxygen Reduction Systems

NITRON MG SERIES MEMBRANE NITROGEN GENERATORS

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

unable to summon help as a result of injury, ill health or an emergency. unable to carry out a task safely while alone.

Less oxygen, more safety and quality. Targeted protection during production, storage and transportation, through inerting

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

TURBO OXYGEN NITROGEN PLANT

Nitrogen Generators. PMNG Commercial Series. Section 50 Bulletin A -20

Spirax Compact FREME Flash Recovery Energy Management Equipment

AirSep PSA Nitrogen Systems

SAFETY TRAINING LEAFLET 06 CARBON DIOXIDE

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

Pressurised Oxygen Supply for CO 2 Capture Applications

KOMPRESSOREN COMPRESSORS KAESER AIR SERVICE Our Services An Overview

NGN Series nitrogen generator

ON-SITE INDUSTRIAL GASES. Nitrogen & Oxygen Generators

TECHNICAL INFORMATION

Nitrogen Advantage. Better Tire Pressure Retention. Improved Fuel Economy. Extended Tread Life. Elimination of Oxidation. Reduction in Tire Failures

TSS21 Sealed Thermostatic Steam Tracer Trap

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

High Pressure Compressed Air and Gas Solutions

Holistic Atmosphere Management System (HAMS)

BUBBLER CONTROL SYSTEM

MARITIME PROTECTION NITROGEN SYSTEM

Good things come in threes

BCGA GUIDANCE NOTE 17

Wagner Fire Safety Management Consultants

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

E PGN-11. Part of NTW (O)32 Estates Operations and Maintenance Policy Paul McCabe Head of Estates and Facilities-NTW Solution Ltd

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

Cryostream 800 Series

DF1 and DF2 Diffusers

4m Blanco Glycol Chiller system: history, recent events, present status and plans

ISOPA PRODUCT STEWARDSHIP PROGRAMMES. Walk the Talk TDI USERS. 1 Version09/06

Innovative Pressure Testing Equipment

Code of Practice and Instructions to Contractors Working for Viridor

Trifecta High-Pressure Systems

Potter Nitrogen Generators

DCV1, DCV3 and DCV3LT Disc Check Valves Installation and Maintenance Instructions

M-06 Nitrogen Generator (Nitrogen Making Machine)

METHODS TO PREVENT THE PREMATURE ACTIVATION OF RELIEF DEVICES ON TRANSPORT TANKS

The new CryoEase Service - your No. 1 choice of gas supply

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

IMMANUEL CHURCH, CHICHESTER HEALTH AND SAFETY POLICY

University Safety Policy Supplement

USE OF RESIDUAL PRESSURE VALVES

Membrane modules for nitrogen and oxygen generator systems. Technology Overview ENGINEERING YOUR SUCCESS.

LABORATORY GAS GENERATORS

Atlas Copco. On-site Industrial Gases Nitrogen & Oxygen Generators

User Manual 1 P a g e Rev. V1.6-EN 11/08/2014

CRYOSPEED CRYOSPEED. Leading edge cryogenic gas supply solutions.

CO 2 and O 2 scrubbers

Applied Compression s nitrogen generator packages offer users a cost-effective alternative to costly bottled nitrogen.

Drum / cylinder handling

AFDXXX(X)AC Series Operators Manual Please read this manual thoroughly before attempting to operate your water maker.

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

CP10 Sensor Installation and Maintenance Instructions

Mitigation Starts With Design! Continues with Safe Operation, Mechanical Integrity and Training!

THE GUIDE TO MEMBRANE NITROGEN GENERATORS

Turnkey Industrial Gas Projects and Equipment

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

/ /

Wilkins Safety Group

Decant Filling of Gas Cylinders

Class 2 Gases Learning Tool

Hazardous Substances Policy - Control Measures POLICY

TP1 and TP2 Temporary Cone Shaped Strainers

CONTROL SOLUTIONS DESIGNED TO FIT RIGHT IN. Energy Control Technologies

80% Less installation time with just two welds for fast and efficient installation.

Laser Cutting. Nitrogen Solutions for

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

Medical Oxygen Concentrator Systems. Generate gases on site generate savings

Delivery of Low Pressure Liquid Nitrogen

SOAS LONE WORKING GUIDANCE

Medical Oxygen Concentrator Systems. Generate gases on site generate savings

Solaris Nitrogen. Installation Guide. Solaris Nitrogen Installation Guide Rev 1 PN IG /09/16


Oil-injected rotary screw compressors GA (VSD + )

Confined Space Entry. My Experience so far.

A Checklist for a Health and Safety Risk Assessment

Faculty/School: Pharmacy Initial Issue Date: Oct 2016

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

BUBBLER CONTROL SYSTEM

the new Ve- / VSE Range

F All types of inert gas systems are to comply with the following:

OPERATION MANUAL NTF-15

Gas Sampling Fitting with MK2.1 and L-Probe

White Paper. Electrical control valve actuators on oil and gas production separators

Technical Information

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

GUIDANCE FOR MANAGING THE RISKS ASSOCIATED WITH END OF LIFE LPG VEHICLES

Faculty/School: Pharmacy Initial Issue Date: Oct 2016

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

OPERATION MANUAL NTF-60 Plus

The Air Liquide Gas System Equipment Brochure

Emergency Situation Assessment

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)


MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

Transcription:

Unifrost NV/SA and Air Products Our work together Unifrost are committed to best practices in health, safety and environmental protection, and the use of nitrogen follows from this. We re very pleased with both the nitrogen generator and the service we have received from Air Products. Bart Oliver, Technical Manager, Unifrost, Koolskamp, Belgium.

Case Study Unifrost NV/SA and Air Products Our work together 2003 Air Products and Chemicals, Inc. All rights reserved. No part of this publication may be reproduced without the prior permission of Air Products.

PRISM Membrane System

Unifrost NV/SA 1 Companies who use automated warehouses for cold-storage may soon face a new safety requirement: the use of nitrogen to reduce fire risks. That s what happened to Unifrost NV/SA, a leading Belgian producer of frozen vegetables. Unifrost found an economical and reliable source of nitrogen in the Air Products PRISM nitrogen generator.

2 Frozen vegetables may sound an unlikely fire hazard, but Belgian frozen food producer Unifrost takes the issue seriously at its state-of-the-art 200,000m 3 automated warehouse. Though the vegetables themselves are not very flammable, packaging and pallets certainly are, along with the polyurethane foam used to insulate the warehouse walls and maintain the temperature at 22 C. Should a fire take hold, the layout of an automated warehouse makes fire-fighting difficult: Underneath the insulation there is not really a building, explains Bart Ollivier, Unifrost s Technical Manager. There is just a steel frame, nearly 30m high, that s designed for automated vehicles, not people. This is the compressor that drives the Membrane System

In the oil and chemical sector, reduced-oxygen atmospheres have for many years been a common method of reducing fire risks. Now fire safety authorities and insurers are encouraging other sectors to consider using reduced-oxygen atmospheres. As a result, companies who use automated warehouses and not just in the frozen food sector are turning to Air Products for advice. 3 Unifrost warehouse The idea is simple: fires need oxygen to burn, so they can be slowed or prevented by lowering the oxygen level of the atmosphere inside the warehouse. Ordinary air containing 21% oxygen creates the fire hazards with which most people are familiar. If the level of oxygen is reduced to 17%, however, fires become hard to start, and tend to smoulder without spreading. Reducing oxygen levels to 10 12% most materials will not burn at all. Although the Unifrost warehouse is automated, day-to-day operations do require manual intervention. This is mainly because pallets and boxes shrink slightly during storage and the resulting loss of balance can derail them from the automated system. To allow people to work safely in the reduced-oxygen atmosphere, a number of layers of protection operational, design and medical are required. Reducing the oxygen level means replacing some of the oxygen with another gas that is non-flammable, non-toxic and preferably cheap. The obvious choice is nitrogen, and Unifrost opted for an Air Products PRISM membrane nitrogen generator with an associated oxygen monitoring and control system. The complete system is compact, reliable and economical. Apart from lower insurance premiums, there s not a great deal of payback from using nitrogen, admits Bart Ollivier. But Unifrost and our parent company, Dujardin Foods, are committed to best practices in health, safety and environmental protection, and the use of nitrogen follows from this. We re very pleased with both the nitrogen generator and the service we have received from Air Products.

4 Hall of plenty Unifrost produces a wide range of frozen vegetables, mostly under supermarket labels. The company was founded in 1974, when frozen vegetables were still a novelty for many consumers in continental Europe. The factory, 15 miles south of Bruges, occupied 3,000 m 2 and employed just 15 people to produce 1,500t/y of frozen vegetables. As tastes have changed, the factory has expanded. In 1990 Unifrost began an ambitious investment programme covering the whole site, which now occupies 100,000m 2 and employs 300 people. Four freezing lines and 11 packaging lines turn out more than 800 individual product types. 70,000t/y of vegetables frozen on site are supplemented with produce frozen elsewhere, yielding a total output of around 110,000t/y. A big part of the investment is the new automated warehouse for storing packaged frozen foods. Completed in 2000, the warehouse measures 130m long, 55m wide and 28m high. It can hold 36,800 euro-pallets, or around 26,000 pallets in mixed sizes. The state-of-the-art warehouse has ten levels, each containing pallets stacked up to six deep and serviced by up one or two automated vehicles. There are five Typical process flow diagram for PRISM Membrane system

elevators: two each for goods entering and leaving the warehouse, and one for the vehicles. The warehouse handles up to 2,000 stock movements every day, and is completely unattended except for maintenance. 5 A mechanical refrigeration system with air circulation fans keeps the warehouse temperature at a steady 22 C. Heat leakage is minimised by 200 mm of foam insulation, sandwiched between steel panels, and by airlocks on the doors. While construction was still under way, Unifrost decided to equip the warehouse with a nitrogen system to allow it to work at reduced oxygen levels. The company approached Air Products and another industrial gas supplier for advice and quotations. We already had a good working relationship with Air Products, notes Bart Ollivier. Unifrost, he explains, has for several years bought Air Products liquid nitrogen for one of its freezing lines, and liquid oxygen for the Air Products OXY-DEP biological treatment process installed at the site s wastewater plant. Following the tradition of this successful relationship, Air Products staff spent a good deal of time working with Unifrost to ensure that the nitrogen generator would do its job effectively. Yet any proposal, however good technically, must also be affordable,

6 Inside of a PRISM Membrane system and the final decision to go with Air Products was made on price, says Bart Ollivier. Measuring up Air Products and Unifrost worked together to calculate the size of nitrogen generator they would need, based on a nominal oxygen level of 17% in the warehouse atmosphere. Since the plan was to maintain the reduced-oxygen atmosphere permanently, the

7 time needed to reach the working oxygen level was not critical. Instead, the nitrogen demand would depend mainly on the amount of gas lost through leakage. Detailed estimates of the number of stock movements daily, and the amount of gas lost each time the warehouse doors are opened, allowed Air Products to calculate the amount of nitrogen needed to make up the losses. The amount of nitrogen required would not have been economic to generate by evaporating liquid nitrogen, especially since high purity is not needed. Instead, the duty is perfect for a nitrogen generator that uses a semi-permeable membrane to

8 separate nitrogen from atmospheric air. Air Products proposed a PRISM G5000 generator. This self-contained unit measures just 3.5m x 1m x 2m (l x d x h), and needs only three connections: electricity, compressed air and a drain. The compressor measures another 2.4m x 1.7m x 1.9m (l x d x h) and requires a separate electrical connection. Because the warehouse is so large, if the nitrogen generator were to stop working it would take several days for the oxygen concentration to approach atmospheric levels. As PRISM generators are reliable and need little maintenance, Unifrost decided not to install a backup nitrogen system. Air Products has plenty of time to fix it, in the unlikely event that anything should go wrong! says Bart Ollivier. Control panel Analyser

As part of the proposal Air Products defined the requirements for the control system, including oxygen sensors, to ensure that the required oxygen level is maintained throughout the warehouse atmosphere. The control system also monitors the integrity of the nitrogen generator, and if a fault is found it switches off the generator and raises an alarm in the control room. There are options for continuous logging of oxygen levels and remote monitoring of system functions through Unifrost s own control system. 9 The control system also monitors the atmosphere in the ancillary rooms next to the warehouse. If the oxygen concentration here falls to a potentially dangerous level, the system switches off the nitrogen generator and raises alarms so that people can be evacuated if necessary. Safety and reduced-oxygen atmospheres Historically, the industrial gas industry has been very concerned about reducedoxygen atmospheres as asphyxiation has been recognised as one of the more common causes of death. Air Products is a signatory to the American Compressed Gas Association guidance on safety in reduced-oxygen atmosphere, which states that atmospheres containing less than 19.5% oxygen must be treated as hazardous.

10 The European Industrial Gas Association s Document 44/00 states: Any depletion of oxygen below 21% must be treated with concern. The situation is hazardous as soon as the oxygen concentration is less than 18%. At Unifrost the intention was to operate permanently at 17% oxygen, with limited manual intervention. This situation required a different approach from the one normally used by industrial gas companies. Air Products therefore performed a safety study that led to stringent design, operational and medical requirements, which in turn provided Unifrost with several levels of protection. Although these had commercial consequences, Unifrost supported its legal obligation to provide a safe place of work. Going ahead Happy with the overall commercial proposal, Unifrost signed a long-term rental contract with Air Products for the PRISM unit. The contract contains a considerable amount of detail to ensure that it meets the requirements of both parties, but in essence it guarantees that Unifrost will not be penalised for any periods when the generator is inoperable. Air Products is responsible for monitoring the generator performance - by telemetry - from a local Air Products engineering centre, and maintaining the installation. The nitrogen system was installed in 2001, though full commissioning was delayed until October 2002 because of teething problems with the automated pallet-moving machinery. Now the system is up and running, Bart Ollivier says he is pleased with its performance. After switch-on the oxygen level fell from 21% to 19% in three days, and to 17% in another three days. So far, we re very pleased with the system, says Bart Ollivier. It was installed with very little fuss, and it does the job it was designed to do. What more could we ask for?

tell me more www.airproducts.com/prism Air Products Plc, Hersham Place, Molesey Road, Walton on Thames, Surrey KT12 4RZ, England Tel: 0800 3890202 Fax: 01270 259506 E-mail: info@apci.com Air Products N.V. Chausse de Wavre 1789, Wversesteenweg, Brussels 1160 Belgium Telephone: 00 32 2 674 9411, Fax 00 32 2 674 9462 E-mail: info@apci.com L0000