LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

Similar documents
LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

Transmitter CS 21 Operation Manual

Transmitter CS 21 Operation Manual

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

CC Operation Manual Oak Valley Drive, Suite 20, Ann Arbor, Michigan USA fax

Operating Instructions

INSTRUCTION MANUAL Pressure Relief Device LPT

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

AMS 2710 PCB pressure sensor module with V output

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

MEMS VOC Gas Sensor. (Model No.:GM-503A) Manual. Version: 1.0. Valid from: Zhengzhou Winsen Electronics Technology Co.

Technical Data Sheet MF010-O-LC

Datasheet: K-30 ASCII Sensor

Please read these instructions carefully before use! Please consider the safety instructions! Please keep for future reference!

Electro-Pneumatic Converter YT-940 SERIES

Model PDT Dewpoint Transmitter

Mass Flow Meter (MFM) for Gases

Torque Tube TB300 Digital Transmitters

ATS430 turbidity sensor Retractable insertion assembly

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Mass Flow Meter (MFM) for gases

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Thermal flow sensor TA Di for separate evaluation units for measuring mass flow, standard flow rate and air or gas consumption.

GAS FUEL VALVE FORM AGV5 OM 8-03

LED 14W POLO BULKHEAD WITH MICROWAVE SENSOR

Oxymax COS61/COS61D. Technical Information

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Pressure Transmitters 36 F-27839

better measurement Simply a question of

PURA. Pure Gas Dewpoint Transmitter. Users Guide

JUMO dtrans p30 Pressure Transmitter

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Manual. MEMS Combustible Gas Sensor. Zhengzhou Winsen Electronics Technology Co., Ltd. (Model No.:GM-402B) Version: 1.0. Valid from:

Air Differentail Pressure Switch

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Magnetic level switch type MR783 Instruction Manual

PROCESS ANALYSERS. SERVOPRO PureGas. Gas Purifier. Operator Manual. Part Number: A Revision: 0 Language: UK English

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving

IP65 Air Differential Pressure Switch

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

Art PRESSURE REDUCER

L3 Pressure and Level transmitter

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

O3 3E 1 F Gas Sensor Module

FLAMMABLE GAS SENSOR/TRANSMITTER

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

C-Flow Coriolis Mass Flow Meters

Pressure Measurement Single-range transmitters for general applications

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

TGD-L (LP) Tank Gauging Device TGD L (Level) TGD LP (Level Pressure) Main features:

Autocalibration Systems For In Situ Oxygen Analyzers

Pre-filter for Brushless Blower Instruction Manual

Operating Manual VSA100A. tina29e1 ( )

Gas Pressure Regulator HON 200

deltaflowc deltaflowc Venturi or Probe

SPD310/SPD360 Air Differential

Flow metering in gases Introduction to COMBIMASS family

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

PyroCouple Series Operators Guide

High-performance submersible pressure transmitter For level measurement Model LH-10

Electropneumatic Transducer (I/P) Installation, Operation and

Instruction Manual BA90 Precision Barometer

Pressure Independent Control Series

Best Practice Guide, Servomex 2700

Mounting instructions. Strain transducer SLB-700A. B 26.SLB700A.10 e

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Operating Instructions Part No

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

Operating Instructions Part No

MODEL GT820 OXYGEN SENSOR

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

VERTICAL AIR COMPRESSORS

PRELIMINARY DATASHEET

I/P Transducer Positioner Module

OXY 3690 MP. Measuring transducer for air oxygen

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Mass Flow Controller (MFC) for Gases

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

DTG - LCD Digital Temperature Gauge USER MANUAL

Dextens Thermo Conductivity Sensors. Type 52101, 54101, 55101

VERSION 1 SUMP PUMP PIT UNIT KAWAMOTO PUMP ASIA CO.,LTD.

GasSense NDIR User Manual

SERIES 500 VARIABLE RANGE PNEUMATIC DIFFERENTIAL PRESSURE TRANSMITTER

1. PARTS INTRODUCTION ELECTRICAL NOTES INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10.

AMT-Ex Dewpoint Transmitter

ph measuring system for hygienic process applications

INSTRUCTION MANUAL COMPACT PRESS. SWITCHES SERIES PCS & PCA

Mass Flow Controller (MFC) for Gases

Transcription:

LK-SX VOC Combined sensor mixed gas Data sheet Subject to technical alteration Issue date: 24.08.2015 Application The sensor detects air quality in ventilation ducts. A stronger output signal of the sensor (0..10 V) indicates bad air quality. For measuring mixed gas, a metal oxide sensor is used. Through automatic self-calibration via a software algorithm, no manual calibration is necessary. For direct hook up to a DCC or monitoring systems analogue outputs (0..10 V) are available. Security Advice Caution The installation and assembly of electrical equipment should only be performed by authorized personnel. The product should only be used for the intended application. Unauthorised modifications are prohibited! The product must not be used in relation with any equipment that in case of a failure may threaten, directly or indirectly, human health or life or result in danger to human beings, animals or assets. Ensure all power is disconnected before installing. Do not connect to live/operating equipment. Please comply with Local laws, health & safety regulations, technical standards and regulations Condition of the device at the time of installation, to ensure safe installation This data sheet and installation manual Notes on Disposal As a component of a large-scale fixed installation, Thermokon products are intended to be used permanently as part of a building or a structure at a pre-defined and dedicated location, hence the Waste Electrical and Electronic Act (WEEE) is not applicable. However, most of the products may contain valuable materials that should be recycled and not disposed of as domestic waste. Please note the relevant regulations for local disposal.

Page 2 / 5 Issue date: 24.08.2015 Application Notice for Air Quality Sensors VOC Unlike CO2 sensors, which specifically measure CO2, mixed gas sensors detect a wide range of gases. The sensor signal does not indicate the type of gas or it s concentration in ppm. Mixed gas sensors detect gases and vapours consisting of carbohydrates, or more generally gases that can be oxidised (burnt): Odours, perfume, cleaning fluid scent, tobacco smoke, new materials fumigations (furniture, carpets, paint, glue...). Unlike CO2, which humans cannot sense, the amount of odours (VOC) indicates the level of air quality. VOC sensors have proven their value in a multitude of applications for many years. Measuring principle: Similar to a catalyst converter the organic molecules are burnt (oxidized) when in contact with the sensor s heated -dioxide surface, adding a small amount of heat combustion. The increased temperature is measured providing a signal proportional to the number of molecules being burnt. CO2 cannot be detected as it cannot be further oxidized. Refrain from touching the sensor s element sensitive surface. Touching the sensitive surface element will void warranty. Information about Calibration VOC Similar to a catalyst converter the VOC sensor will deteriorate over time, which will affect the sensitivity. This VOC sensor automatically compensates the decrease in sensitivity by dynamic auto-calibration. The reference level of air quality is derived from the ambient conditions over a 72h period. The lowest reading within this 72h time period will be used as reference level, representing the clean and fresh air level. Technical Data Measuring values VOC Output voltage 0..10 V, load min. 10 kω Power supply 15..24 V = (±10%) or 24 V ~ (±10%) Power consumption max. 1,5 W (24 V =) 2,9 VA (24 V ~) Measuring range velocity 0..100% Air speed max 10 m/sec Calibration self calibration Sensor VOC-Sensor (heated tin oxide semiconductor) Enclosure PA6, pure white Protection IP54 according to EN 60529, IP65 with bolted cover Cable entry M20 for wire max. 8 mm Connection electrical plug-in terminal max 1,5mm² Pipe PA6, black, Ø=19,5 mm L=180 mm, Filter stainless steel, wire mesh Ambient condition 0..+50 C, max 85%rH non-condensing Weight 400 g Delivery content MF20 flange Notes mixed gas sensors detect gases and vapours which can be oxidised (burnt): Body odours, tobacco smoke, exhalations emitted by materials (furniture, carpets, paint, glue...)

Issue date: 24.08.2015 Page 3 / 5 Mounting advices The sensor can be mounted on a flange (recommended) or directly into the ventilation duct. Please note that during installation the openings of the pipe are mounted in the direction of air flow! Mounting without and with mounting flange: Mounting with mounting flange Dismounting advice Sensor solve and vertically pull out. Do not tilt the sensor during withdrawal!

Page 4 / 5 Issue date: 24.08.2015 Terminal Connection Plan Terminal assignment: Clamps Function 1 24 V 2 GND 3 Not used 4 Not used 5 Not used 6 Not used 7 Output VOC 0..10 V Application notice Dirt in the air can collect on the filter and then adversely affect the operation of the sensor after a certain time. Under normal ambient condition an annual maintenance is recommended. Rinse the filter after cleaning with distilled water and dry it using clean oil-free air or nitrogen. Extremely contaminated filters should be replaced. At extreme ambient conditions, e.g. corrosive gases, the humidity sensor may have to be changed.

Issue date: 24.08.2015 Page 5 / 5 Dimensions (mm) Accessories Rawl plugs and screws (2 pcs each) Item No. 102209 Filter stainless steel, wire mesh Item No. 231169 Mounting flange MF20 TPO Item No. 612562