MODEL DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT

Similar documents
MODEL ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT

APPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL

Polatrak ROV II - Tip Contact Probe Operation Manual

Gas Pressure Probe. Information Sheet. Total Dissolved Gas

Hydraulic Punch Drivers

Handling instructions for GISMA connectors HI

32374 R. Jazowski 4/4/ D. W. Mudge G. Sivik 1 of 8 ODN TITLE: Installation & Operation Manual for Nautilus G2 Connectors

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

GM-121: Container End Lock Anchor Wand Page 1 WINSAFE CORP. GM 121 CONTAINER END LOCK ANCHOR WAND OPERATING INSTRUCTIONS AND MAINTENANCE


BP48-1 AND SSP48-1 IN-GROUND POST INSTALLATION INSTRUCTIONS

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

DEEPSEA. Power & Light. Micro SeaLaser. Operator s Manual Ruffin Road San Diego, CA USA T: (858) F: (858)

Hydraulic Punch Drivers

RollGliss Rescue Emergency Descent Device. This manual is intended to be used as part of an employee training program as required by OSHA.

Teledyne Oil & Gas North Williamson Blvd. Daytona Beach, FL USA (phone) (fax)

Position locking powerful chuck. CKL2-*-HC Series CKL2-40CS-HC CKL2-50CS-HC CKL2-63CS-HC CKL2-80CS-HC Compressed air to

C-Flow Coriolis Mass Flow Meters

INSTRUCTION MANUAL Pressure Relief Device LPT

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

WINSAFE CORP. OPERATING AND MAINTENANCE INSTRUCTIONS GM184 TOP ACCESS END LOCK ANCHOR WAND

T EK-SUB 4800C 19 mm Submersible Level Transmitter

Encore PE 50-lb Feed Hopper

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

Depth transducer TH 52

User Manual V14.1 IP68 LED FLEX NEON

Figure 1: Hydrostatic Pressure Forces Are Perpendicular to the Surface

GM-120: Container Top Lock Anchor Wand Page 1 WINSAFE CORP. GM 120 CONTAINER TOP LOCK ANCHOR WAND OPERATING INSTRUCTIONS AND MAINTENANCE

MANUAL: Jumbo Siamese and Jumbo Wye

Made in the USA. For Fall Protection Only. SafeLok Part Description

TECHNICAL DATA. Trimpac 244a. September 16, 2013

M2 Antenna Systems, Inc. Model No: VLP16

QUICK START GUIDE CB-150 DATA BUOY PLATFORM

Threaded Closures Installation, Operation & Maintenance

Precision pressure sensor Basic version Model CPT6020

Model MTB-ASME Vertical Bladder Tanks

Underwater Housing for Canon EOS M

Model PSI Compressor with 3-Gallon Air Tank 12VDC

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

750 Cable Cutter INSTRUCTION MANUAL

WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

Technical Data Sheet MF010-O-LC

Electro-Pneumatic Converter YT-940 SERIES

TURBINE SEAL: AXIAL TYPE DESIGN

CONUS MSR0680 UNDERWATER LIGHT. Registered Community Design. Operating Instructions

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Handling instructions for GISMA connectors HI

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

3/4 SafeClaw Anchorage Connectors

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

OPERATING MANUAL EASY-LOAD PUMP HEADS

Horizontal Bladder Tanks

Rocky Mountain Instinct / Pipeline Alloy Frame Assembly Guide. Date: April 7, 2017

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Operator s Safety Manual Sumner Max Jax / Beam Jax

TECHNICAL DATA. Trimpac 257a. September 16, 2013

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Model 6812C Dual Lane Scoreboard Owner s Manual

TECHNICAL DATA. Trimpac 256a. October 31, 2013

Royce Interface Level Analyzer and Sensors

GRAVITY BIKE RACK ASSEMBLY & OPERATING INSTRUCTIONS

Model VR6 System. Installation, Operation & Maintenance

STARLOG. Capacitive Water Depth Probe

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Operating manual Mobile Man Anchor IM-200 Reference No. IM 200

CKL2 Series. Powerful chuck. Operational stroke length: 5, 6, 8, 10, 12, 16, 20, 23mm. Specifications. Switch specifications

Geotech 1.66 Reclaimer

Installation and Operation Instruction Manual

QUICK START GUIDE CB-450 DATA BUOY PLATFORM

AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS

DEEPSEA POWER & LIGHT. Operator s Manual. SeaLite Six. Original Instruction Ruffin Road San Diego, CA USA

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

35 TON HYDRAULIC PUNCH WARNING

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

DTG - LCD Digital Temperature Gauge USER MANUAL

Membrane covered optical CO 2 sensor

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

MPM426W/436W Submersible Level Transmitter

PURA. Pure Gas Dewpoint Transmitter. Users Guide

NHR-X-X Encore Feed Hoppers

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

Vertical Bladder Tanks

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Depth/Level. Druck Submersible Pressure Sensors Product Guide. GE Sensing. Applications. Features

100C Air Compressor Kit

TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Infrastructure Sensing. Features. Applications

QUICK START GUIDE CB-950 DATA BUOY PLATFORM

deltaflowc deltaflowc Venturi or Probe

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

1 SafeClaw Anchorage Connectors

DK ton, Double-acting, Die-type Crimping Tool

Transcription:

MODEL 863-000-200 DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT DOCUMENT NO. 430-017C April 14, 2005 S/N IMAGENEX TECHNOLOGY CORP. 209-1875 BROADWAY STREET PORT COQUITLAM, B.C. CANADA, V3C 4Z1 TEL: (604) 944-8248 FAX: (604) 944-8249

IMAGENEX MODEL 863 DIGITAL ALTIMETER 863 Altimeter 445-008 AUGUST 2002-REVISED APRIL 2016 APPLICATIONS: FEATURES: Measure altitude of structures & objects NMEA 0183 Serial Output Measure range to other structures & objects Self contained Monitor sedimentation or scouring Low power ROV, AUV, & UUV Compact size The Imagenex Model 863 is a completely self-contained altimeter with a digital output. It is mounted in a pressure proof housing with an underwater connector for use at depth. The 863 Altimeter measures the range to the bottom or other large objects. It requires only power and an RS-232 or RS-485 serial interface to an external device. Specifications subject to Copyright 2002-2018 change without notice www.imagenex.com Imagenex Technology Corp.

HARDWARE SPECIFICATIONS: FREQUENCY 330 khz RANGE 0.6 m 30 m (2 100 ) TRANSDUCER Conical beam TRANSDUCER BEAM WIDTH 10 TRANSMIT PULSE LENGTH 100 microseconds RANGE RESOLUTION 20 mm MIN. DETECTABLE RANGE 0.6 m (2 ) MAX. OPERATING DEPTH 1000 m (3000 m and 6000 m available) INTERFACE RS-232 @ 4800 bps (RS-485 optional) CONNECTOR Four conductor, wet mateable (Subconn MCBH4M-AS) POWER SUPPLY 22 32 VDC at 100 ma max. DIMENSIONS 89 mm (3.5 ) diameter x 125 mm (4.93 ) length WEIGHT: In Air In Water MATERIALS FINISH 1000 m unit: 1.2 kg (2.6 lbs) 1000 m unit: TBA 6061-T6 Aluminum & PVC Anodized ORDERING INFORMATION: 1000 m UNIT Standard 863-000-200 3000 m UNIT Standard 863-000-201 6000 m UNIT Standard 863-000-202 RS-485 Option -007 Product and company names listed are trademarks or trade names of their respective companies. 863 Altimeter 2 445-008 www.imagenex.com

TABLE OF CONTENTS 1. SPECIFICATIONS 2. SYSTEM DESCRIPTION 3. INSTALLATION INSTRUCTIONS 4. MAINTENANCE 5. WIRING DIAGRAM

1. SPECIFICATIONS 1.1 SYSTEM SPECIFICATIONS 1.1 IMAGENEX MODEL 863-000-200 ECHO SOUNDER MODULE Operating Frequency: Transducer Beam Angle: Transmit Pulse Length: Output: Range Resolution: Overrange Output: No Return Output: Power Supply: Connector: 330 KHZ 10 degree total included angle to 3db points 100 microseconds Serial (RS-232 @ 4800,N,8,1) NMEA 0183 $SDDBT string 26.7 microsecond (2cm) 0 microseconds 0 microseconds 20-36 VDC at 100 ma maximum Impulse MCBH-4-MP-SS (mates with MCIL-4-FS) 4 conductors, 2 for power, 2 for serial Materials: Finish: Maximum Operating Depth: Dimensions: aluminum 6061-T6, 300 series stainless steel, pvc, acetal homopolymer, epoxy Hard anodize 1000M (3,300 ft) 89mm (3.5in) dia. x 120mm (4.75in) high Weight: in air 1.1kg (2.4lb)

2. SYSTEM DESCRIPTION The Imagenex Model 863-000-200 Digital Altimeter is a self contained module which includes a transducer, a transmitter, a receiver, and a microcontroller. It operates by transmitting a short acoustic pulse, and then detecting the echo from the bottom or other large object. It measures the time from the transmitted pulse until the echo is received and outputs this time to the serial port. The module is packaged to operate underwater at depths to 1000 M (3,300 feet). Typical applications for this product include a remotely operated vehicle (ROV) altimeter, an autonomous underwater vehicle (AUV) altimeter and any other application where ranges must be measured underwater.

3. INSTALLATION INSTRUCTIONS 3.1 MOUNTING DIMENSION DRAWING 345-006 3.2 INSTALLATION The altimeter is normally mounted vertically, with the transducer face pointing vertically down at the bottom. The transducer face must have a clear unobstructed view. The altimeter can be mounted by means of the tapped holes on the connector end cap or it can be clamped around its diameter. The anodized housing should be protected by plastic or rubber isolation to prevent damage. Due consideration should be given to materials used to clamp the housing, and to electrical isolation from dissimilar metals, to avoid galvanic corrosion of the housing. The altimeter should be protected from physical damage by collision with the bottom or other objects. The electrical connector should be protected from physical damage and the cable should not be bent sharply near the connector. Underwater Connector Guidelines: Lubricate with silicone grease before assembly Mate with minimum twisting and flexing Align index pin and socket carefully Do not damage or bend pins in unmated condition On a typical ROV installation, the IMAGENEX supplied cable connector is spliced to a customer supplied cable harness on the vehicle. The splice should be suitable for underwater operation. Suitable splices include cast epoxy splices, cast polyurethane splices, moulded rubber splices (so called hot splices) and tape splices. This will pass into the vehicle pressure hull or a junction box. The four conductors will be split into two conductors for power, connected to a suitable power supply in the vehicle's power distribution system and two conductors for the echo sounder serial output. 4. MAINTENANCE

The altimeter should be rinsed with fresh water after each immersion in salt water or dirty fresh water. This will prevent accumulation of salt or other contamination, and help prevent corrosion of the aluminum and stainless steel parts. The altimeter should be inspected periodically for signs of galvanic corrosion. The transducer face should be carefully cleaned with a detergent solution to remove any oil, grease or other deposits which may reduce the acoustic performance of the unit. Model 863-000-200 DIGITAL ALTIMETER DISASSEMBLY AND ASSEMBLY The altimeter is a complex precision package. We recommend that only personnel familiar with miniature underwater electronic/mechanical devices attempt to service or repair this device. Refer to the assembly drawing to understand the general construction of the Underwater Unit. The connector end cap can be removed by removing the four hex socket cap screws on the connector end cap and carefully withdrawing the end cap. Extreme care must be taken when reassembling the Underwater Unit. The O-ring groove and sealing face should be carefully cleaned and inspected. After cleaning, the groove and face should be coated with a thin uniform coat of silicone grease. A new o-ring should be used if possible. The o-ring should be carefully cleaned and inspected for defects, and then lubricated with a thin uniform coat of silicone grease. A small scratch in the o-ring groove or sealing face, a small piece of dirt, or a defect in the o-ring, can cause leakage and consequent flooding of the unit.

5. WIRING DIAGRAM DWG. NO. 863-200-184 MODEL 863 ALTIMETER PIGTAIL WIRING (20-36VDC)

Here is a sample output from our Model 863 Altimeter: $SDDBT,16.93,f,5.16,M,2.821,F $SDDBT,16.93,f,5.16,M,2.821,F $SDDBT,16.93,f,5.16,M,2.821,F $SDDBT,16.86,f,5.14,M,2.810,F $SDDBT,16.86,f,5.14,M,2.810,F $SDDBT,16.86,f,5.14,M,2.810,F $SDDBT,16.93,f,5.16,M,2.821,F $SDDBT,16.86,f,5.14,M,2.810,F $SDDBT,15.68,f,4.78,M,2.613,F $SDDBT,15.55,f,4.74,M,2.591,F $SDDBT,15.55,f,4.74,M,2.591,F - the output is NMEA 0183 (4800,N,8,1) - RS-232 (optionally RS-485) - output rate is approximately 3 messages per second.