Blease900 Ventilator PATIENT CENTERED VENTILATION

Similar documents
BleaseFocus Anesthesia System VERSATILE ANESTHESIA

Anesthesia Workstation

A9600 Anesthesia Workstation. Your healthcare, we care.

Panther 5 Acute Care Ventilator

BleaseDatum Anesthesia Vaporizers PEACE OF MIND. Serving The HealthCare Industry

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

State-of-the-art anesthesia technology

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

Your patients, our primary focus. Siesta i Whispa anesthesia machine

Technical Data and Specifications

SLE5000 Infant Ventilator with HFO

fabian HFO: Modular, Powerful, Versatile.

The centerpiece of a comprehensive anaesthesia workstation

VENTILATION SERVO-i INSPIRATION IN EVERY BREATH

HAMILTON-C2 HAMILTON-C2. The universal ventilation solution

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

Flight Medical presents the F60

V8800 Ventilator System. Your healthcare, we care.

An intuitive and innovative answer to your anaesthesia challenges

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Expanding versatility. The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients

AUGUST ANESTHESIA MACHINES MEDICAL PRODUCTS ANESTHESIA MACHINES. Quality System Standard applied: ISO 9001, ISO 13485

Your patients, our primary focus

O-Two Self-Study Guide. e600 Transport Ventilator Ventilation Modes

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features)

Meet the changing needs of your patients. Trilogy Series, with advanced ventilator technology

HAMILTON-C3 HAMILTON-C3. The compact high-end ventilator

Basics of Mechanical Ventilation. Dr Shrikanth Srinivasan MD,DNB,FNB,EDIC Consultant, Critical Care Medicine Medanta, The Medicity

Dameca MRI 508. State-of-the-art MRI technology

NEONATAL/INFANT VENTILATOR

UNDERSTANDING NEONATAL WAVEFORM GRAPHICS. Brandon Kuehne, MBA, RRT-NPS, RPFT Director- Neonatal Respiratory Services

IEC C LASSIFICATIONS:

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Intelligent Ventilation solution from ICU to MRI

Update to RS-232 commands. Changing patient from NIV to INVASIVE Vent Type. SNDF command

WILAmed INTENSA. Intensive Care Ventilator System

Mechanical Ventilation

Patient Setup Information

Supporting you in saving lives!

Supporting your patients every breath

GE Healthcare. Aestiva/5. More than superior ventilation

Mechanical Ventilation. Mechanical Ventilation is a Drug!!! is a drug. MV: Indications for use. MV as a Drug: Outline. MV: Indications for use

Oxylog 3000 plus Emergency & Transport Ventilation

Inspiration 7i Ventilator

INTENSIVE CARE VENTILATORS

SLE5000 Neonatal Ventilator with High Frequency Oscillation

APUS Anesthesia Machines

Fabius plus. The plus that makes all the difference. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius plus. The plus that makes all the difference. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

SERVO-s v8.0 Data sheet

Using Common Ventilator Graphics to Provide Optimal Ventilation

Introducing Astral. Greater freedom. Confident care. Designed efficiency

DATA SHEET. VENTILATION SERVO-s

Mechanical ven3la3on. Neonatal Mechanical Ven3la3on. Mechanical ven3la3on. Mechanical ven3la3on. Mechanical ven3la3on 8/25/11. What we need to do"

evolution 3e Ventilators

Fabius Tiro TM. Designed for your environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Completed downloadable Test Bank for Pilbeams Mechanical Ventilation Physiological and Clinical Applications 5th Edition by Cairo

MEDICAL EQUIPMENT IV MECHANICAL VENTILATORS. Prof. Yasser Mostafa Kadah

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Airox Supportair Ventilator

INTELLiVENT -ASV. The world s first Ventilation Autopilot

Siesta i Whispa Integrated technology

Intensa GO Alternate Care Ventilator

Astral in AirView: Improving patient care through connectivity. ResMed.com

Astral in AirView: Improving patient care through connectivity. ResMed.com

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Fabius MRI. From specialists for specialists. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Minimum size for maximum performance

fabian HFO Our 4-in-1 device

Stephanie. Pediatrics. The ventilation system for neonatology

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Emergency Transport and Ventilation

Mechanical Ventilation. Flow-Triggering. Flow-Triggering. Advanced Concepts. Advanced Concepts in Mechanical Ventilation

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

Guide to Understand Mechanical Ventilation Waveforms

New A7 Anesthesia Workstation

Selecting the Ventilator and the Mode. Chapter 6

fabian Therapy evolution Our 2-in-1 device

EVE. The mobile Ventilation Concept from Emergency to Intensive Care. easy - light - smart. Ventilation

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

ALLIED HEALTHCARE PRODUCTS, INC. Litholyme, GE Medisorb, Carbolime, and Amsorb Plus. Test Summary

Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM. Dräger. Technology for Life

How Ventilators Work. Chapter 3

APUS Anesthesia Machines


Operation of Oxylog 3000 ventilator

AV-S Ventilator User Manual

Hospital and Transport for Controlled Breathing

Corporate Overview and Product Summary

Safe Accurate Reliable. CWM-301 Anesthesia System

Automatic Transport Ventilator

RESPIRATORY PHYSIOLOGY, PHYSICS AND PATHOLOGY IN RELATION TO ANAESTHESIA AND INTENSIVE CARE

Carestation 650c. Key Features. Design. Ventilation

MT The secret of harmonious breathing BABYLOG 8000 PLUS

bespoke In general health and rehabilitation Breath-by-breath multi-functional respiratory gas analyser In human performance

Software enhancements

Advanced Ventilator Modes. Shekhar T. Venkataraman M.D. Professor Critical Care Medicine and Pediatrics University of Pittsburgh School of Medicine

Safe and Intuitive Neonatal Ventilation

Transcription:

Blease900 Ventilator PATIENT CENTERED VENTILATIN

PATIENT CENTERED VENTILATIN From the first Blease/Manley ventilator sixty years ago, Spacelabs Healthcare has built a heritage of innovative and intuitive products. ur ventilators are developed in partnership with our customers to address real-life clinical needs. Key elements of our patient-centered anesthesia solution are; PERFRMANCE CHICE VENTILATIN Spacelabs Healthcare - Connecting Innovation with Care.

Performance KEY FEATURES Touchscreen technology Active proportional exhalation valve Rapid leak and compliance testing Minimal maintenance Just as no patient or surgical procedure is identical, neither are the clinicians that attend to them. Performance therefore is more than just technical capability. It is the ability of the ventilator to adapt to its users and their patients. Ease of use, consistency, familiarity and overall speed and safety of pre-use testing are all elements of performance, as they determine how clinicians will respond to, learn, test and train others on a ventilator. Minimal layer menus and multiple methods of navigation (Touch and Trak TM ) provide quick interaction allowing maximum focus on the patient. Gliding through the options and advanced ventilation modes, it is easy to understand why many clinicians choose Spacelabs Healthcare. Performance is also in the capability and precision by which the ventilator matches the clinical settings with delivery to the patient. Active proportional flow valves provide precise ventilation delivery regardless of mode. Safety determines performance. Clear and concise grouping of controls, one touch alarm access and settings reflect this. With an automated leak and compliance test taking less than one minute, the Blease900 delivers accurately even in an emergency. Minimal spare parts and maintenance requirements further support the long term performance and reduction in cost of ownership of the ventilator.

Choice KEY FEATURES Three ventilator models Choice of platform Choice of user interaction, touch or trak wheel Upgrade path available Choice is having options. ptions and expertise allow informed decisions. In the Blease900 series, configuration and interactions are determined by you. Three ventilator models designed to grow with your practice, providing precision and expansion capabilities, cost effectively. Your initial choice of ventilator configuration doesn t have to be final. The Blease900 series integrates smoothly with the robust BleaseFocus or innovative BleaseSirius platforms. A range of ventilation modes, waveform displays and spirometery loops are available to upgrade your ventilator to meet your changing patient s requirements. Each ventilator within the series is equipped with a large 8.4 full color display which can be easily navigated via the new Touch and Trak TM user interface. This provides familiarity to users of touch screen technology and those familiar with rotary wheel type systems. The ability to program up to 14 individual screen settings and preferences is also offered, which can be retrieved for future cases. So whether it is day surgery or cardiothoracic, neonates or restricted airways, volume or pressure, touch or trak, Spacelabs Healthcare has the right choice for you.

Ventilation KEY FEATURES Precision Pressure Control TM Precise fresh gas compensation Decelerating flow ability Dynamic compliance compensation The Blease900 offers Volume Control, Precision Pressure Control TM, SIMV with Pressure Support and Advanced Pressure Support TM. Accurate control is maintained in all modes using not only dynamic compliance and fresh gas flow compensation but also through active control of the inspiratory and expiratory flow valves of the ventilator. Measurement at the Patient Y-piece enhances delivery and allows for the display of pressure and flow volume loops. Spirometery loops present complex data in a graphical format for easier interpretation of ventilation effectiveness, in the presence of changes within the patient. Introducing Precision Pressure Control Ventilation TM (PPCV TM ) Ventilating to a set pressure rather than a volume is not new to anesthesia, but its usage is increasing as more complex and diverse cases are being treated. Blease900 Conventional Pressure Control Ventilation P Target PEEP Pressu ure Control Ventilation vershoot Decay Current challenges with pressure control ventilation include potential overshoot of pressure that could result in patient injury, and lack of integrated volume monitoring to indicate changes in patient and ventilator status. Compliance changes in the patient, and an inability to track these changes through out the breath, can result in decay in the pressure if the ventilator lacks real time compliance measurement and variable flow capabilities. This could lead to insufficient volumes and inadequate gaseous exchange. Similar results may occur with ventilators with fixed flow rates where the patient s demand is higher than the flow during the inspiratory phase. The Blease900 ventilator uniquely meets these challenges. During the entire inspiratory time, the Blease900 uses variable inspiratory flow, as well as an active proportional exhalation valve. Both valves working together to precisely control delivery and maintenance of the target pressure.

Introducing Advanced Pressure Support TM (AdPSV TM ) The patient breathes comfortably, with the ventilator matching demand. KEY FEATURES Advanced Pressure Support TM Adjustable flow trigger Clear indicator of patient effort View, save and review spirometry loops Measurements and compensation at the patient. Comfort and success in pressure support is dependent on the patientventilator interaction, and requires the ventilator to closely match the patient s breathing cycle. The Blease900 ventilator uniquely meets these challenges in both PPCV TM and AdPSV TM. During the entire inspiratory time, the Blease900 uses variable inspiratory flow, as well as an active proportional exhalation valve. Both valves work together to precisely control delivery and maintenance of the target pressure. Measuring patient ventilator dynamics at the patient and using this information during ventilation provides excellent sensitivity and responsiveness. During Advanced Pressure Support TM, flow and the end of inspiration are all determined by the patient rather than fixed time cycling. A visual marker displayed on screen also provides indication of patient effort. Ventilation Monitoring Ventilation, as with any therapy, needs to be monitored and adjusted according to individual patient response. Monitoring should take place as close to the target organ or system as possible to ensure accuracy. Monitoring should provide information on the effectiveness of therapy delivered and track resultant changes in the patient. The Blease900 offers Pressure Volume and Flow Volume loops with the ability to store and review past loops for comparison during ventilation. Review of the spirometry loops can show changes in patient compliance, the presence of leaks, and clearly shows how your different ventilator settings can have an impact on your patient s ventilation.

Technical Specifications Model 990 970 950 Fresh gas compensation 3 3 3 Compliance compensation (ption of pre-set or measured) 3 3 3 Adult, pediatric & neonate 3 3 3 Ventilation Mode Volume control 3 3 3 Pressure control 3 3 3 SIMV + PSV 3 3 3 Pressure support 3 3 Ventilation Monitoring xygen 3 3 3 Inspired and expired volumes 3 3 3 PAW 3 3 3 Pressure waveform 3 3 3 Flow waveform 3 3 3 Spirometry loops 3 Parameters I:E ratio 2.0:1-1:5 Frequency 2-99 bpm Set tidal volume 20-1500 ml Minute volume 0.3-25 lpm Pressure limit adult: 10-70 cmh 2 pediatric & neonate: 10-50 cmh 2 PEEP 3-20 cmh 2 Inspiratory pause 0-50% Sigh function The delivered total volume is increased by 10% every 10 breaths Patient trigger 1-15 lpm Pressure inspired 10-50 cmh 2 Max inspiratory flow 100 lpm Support pressure 5-30 cmh 2 User Set Alarms Pressure high 10-70 cmh 2 (equal to pressure limit in volume control or pressure inspired + 25% in pressure control) Pressure low 5-50cmH 2 MV high 1-25 lpm MV low 0-24 lpm High bpm 3-99 bpm Low bpm 0-98 bpm High oxygen 19-110% Low oxygen 18-109% Static Alarms Apnea Sensor error Vent in operative Inspiratory flow transducer error Setting error Peep error Under pressure Low supply gas pressure No charge Power fail Battery low Comms fail Apnea alarms in bag mode Sustained pressure Fresh gas too high www.spacelabshealthcare.com 2008 Spacelabs Healthcare Specifications subject to change without notice A1005-jy08 / Drg No. 078-0519-00 Spacelabs Healthcare Company Headquarters 5150 220th Ave. SE, Issaquah, WA 98029 P Box 7018, Issaquah, WA 98027-7018 Telephone: 425-657-7200 In North America: 800-522-7025 Fax: 425-657-7212 Spacelabs Healthcare Limited Beech House, Chiltern Court, Asheridge Road, Chesham, Bucks HP5 2PX, England. Telephone: +44 (0)1494 784422 Fax: +44 (0)1494 791497 advsales@spacelabs.com