Self-managing shallow geothermal well systems

Similar documents
Shallow geothermal well systems

SCA Series Inverted Bucket Steam Traps

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

PETROLEUM: Well operations and well examination schemes

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

Installation, Operation and Maintenance Instructions Buffer Vessel OM006

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.

Manual Actuated Boiler Blowdown Valves

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

CONTRACTOR WHS HAZARD STANDARD HAZARDOUS CHEMICALS EXTERNAL USE ONLY

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

Thermocirc Installation and Maintenance Instructions

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

Blowdown vessels Meeting the requirements of HSE PM60

LEGIONELLA MANAGEMENT PROCEDURE

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

GUARDIAN EQUIPMENT Emergency Eye Wash and Shower Equipment. ANSI Z358.1 Compliance Checklist

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

Eaton Filtration, LLC

Renewables. Tribune HE Unvented Hot Water Cylinders Installation and Maintenance Instructions. Issue 17 July 2012

TSS21 Sealed Thermostatic Steam Tracer Trap

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

Method Statement: Testing Dry Riser System

Pibiviesse High Performance Control Ball Valve

1805 Series Relief Valves

Eaton Filtration, LLC

Engineering Data Sheet

CA10S, CA14 and CA14S Air and Gas Traps

TOPLINE ELECTRONICS LTD CO2 CONTROL UNIT MANUAL

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

System Pressure Manager Standard & System Pressure Manager Plus

FT16 Ball Float Steam Trap Installation and Maintenance Instructions

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Bermad Pressure Reducing. Model: 42T

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

Dri-Line Mk3 Monnier Compressed Air Drain Trap

PV4 and PV6 Piston Valves

Hazardous substance risk management

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER

GUIDANCE IN-SERVICE INSPECTION PROCEDURES

GAS PIPELINE SAFETY GUIDE.

SRI Jigger Tubes System

PC3_ and PC4_ Pipeline Connectors

ANSI Z Compliance Checklist

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

MAINTENANCE AND SAFETY OF CNG REFUELLING STATIONS

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

FV Flash Vessel Installation and Maintenance Instructions

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

TITAN FLOW CONTROL, INC.

Installation, operation & maintenance manual - original version

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

POOL FENCING A Guide to the Fencing of Swimming Pools Act 1987

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

CP10 Sensor Installation and Maintenance Instructions

PROPOSED CHANGE TO THE 2015 ONTARIO FIRE CODE (O. Reg. 213/07, as amended current to January 1, 2015)

1. Preface Important Safety Notes Brief Product Information Product Working Principle Installation Guidelines...

Health and Safety Executive. Key aspects of HS(G) 253. Andrew Hall HID CI 1G. HM Specialist Inspector (Mechanical)

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

Steam Trap BK BK 212-ASME. Original Installation Instructions English

Installation and maintenance of twin 45kg LPG cylinder systems

TP1 and TP2 Temporary Cone Shaped Strainers

Installation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

Installation and commissioning instructions 255 series and 256 series

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

Fig 1, Fig 12, Fig 13, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

Fig 1, Fig 12, Fig 13, Fig 14, Fig 16 and Fig 16L Strainers Installation and Maintenance Instructions

Installation, commissioning and servicing instructions

KTM 50 (DN ) Installation, maintenance and operating instructions

Pressure Reducing Valve for Steam Type 2333 A

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

CA44, CA44S, CA46 and CA46S Air and Gas Traps

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant

Part 3.0. Storage Tanks

Installation, commissioning and servicing instructions

Engineered solutions for complex pressure situations

TD10, TD52M and TD259 Thermodynamic Steam Traps Installation and Maintenance Instructions

CPVC Transition Fittings - Female Adapter. CPVC X LEAD FREE BRASS Lead Free Max working pressure F ASTM D 2846

553 Series.

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

S and SF Inverted Bucket Steam Traps

Management Plan for Confined Spaces

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

Installation Operation Maintenance

Network Regulator Maintenance Operatives LS (Non-Accredited)

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Fisher DVI Desuperheater Venturi Inline

Transcription:

GUIDELINES PRACTICE GOOD Self-managing shallow geothermal well systems FOR PCBUs WITH GEOTHERMALLY HEATED POOLS OR PLANT March 2018

These guidelines are for PCBUs (including local authorities) who have geothermally heated swimming pools, mineral pools, or plant such as steam boxes.

Self-managing shallow geothermal well systems KEY POINTS Make sure all wells and pipework are designed and constructed using suitable materials. Make sure a suitably qualified and experienced person carries out inspections and maintenance on your geothermal well system.

CONTENTS 1.0 Introduction 3 1.1 Your legal responsibilities 4 2.0 Shallow geothermal wells 6 2.1 Surface well maintenance 7 3.0 Geothermal heating equipment 9 3.1 Supply pipework 10 3.2 Plant equipment 11 3.3 Hot water system 12 3.4 Mineral pools 12 3.5 Effluent pipework 13 3.6 Steam boxes, drying, and other uses 14 appendices Appendix A: Shallow geothermal well systems template 18 Appendix B: Monthly/weekly/daily registers 19 Appendix C: More information 20

1.0 Introduction IN THIS SECTION: 1.1 Your legal responsibilities 3

1.0 Introduction The purpose of these guidelines is to assist a well owner or manager as a person conducting a business or undertaking (PCBU) to self-manage the shallow geothermal well system. These guidelines apply to shallow geothermal wells, which are defined as wells not exceeding 150 metres (m) in depth, and covers the entire system from production to re-injection. Because a hotel or motel is a workplace under the Health and Safety at Work Act 2015 (HSWA), you have responsibilities as the PCBU (well owner or manager) of a geothermal well for the health and safety of workers and other people. Your geothermal system must also meet the requirements of the Geothermal Energy Regulations 1961 (the Regulations). These guidelines contain the essential technical information that you need to self-manage your geothermal well and include two templates that you can use to check your compliance with the legal and technical requirements relating to shallow geothermal well systems. 1.1 Your legal responsibilities Health and Safety at Work Act 2015 HSWA defines the roles and responsibilities of different duty holders. These include PCBUs, officers, workers and other persons at workplaces. For more information see WorkSafe s special guide Introduction to the Health and Safety at Work Act 2015, available at: worksafe.govt.nz Geothermal Energy Regulations 1961 As well as HSWA the Geothermal Energy Regulations 1961 (the Regulations) set out duties and responsibilities for PCBUs. In particular, regulation 26 of the Regulations states that: all wells and pipework must be constructed of suitable and sound materials. all wells and pipework must be designed, constructed, operated, and maintained in accordance with safe, proper, and proficient geothermal engineering practice. 4

1.0 Introduction the well, and the equipment used in the geothermal work, must be maintained to prevent damage or risk of damage to the well and the equipment, and to prevent danger to persons on the site, or in the vicinity, of the geothermal work. all geothermal work in circumstances where the heat discharged by any well is likely to exceed 20 terrajoules measured above 0 C over any period of 12 consecutive months shall be carried out in accordance with NZS 2402P Code of Practice for Geothermal Heating Equipment in Rotorua (except Parts 2, 6, 7, and 10). the manager must ensure that the site of the geothermal work is maintained in a safe condition. Fencing swimming pools The Building (Pools) Amendment Act 2016 promotes the safety of young children by requiring fencing of certain swimming pools. As the owner, or the person in control of a pool, you must ensure that the pool and immediate pool area is fenced with a fence that complies with the requirements of the Building Act 2004 building code. Make sure to register any existing pool with your local authority. There are also standards that might apply to your swimming pool, for more information refer to: NZS 4441 Swimming Pool Design Standard NZS 5826 Pool Water Quality Territorial authority requirements You must comply with any territorial authorities bylaws as applicable. Check if your local council has bylaws related to mineral pools. Your council might have additional rules that you need to meet. Check with your local council for specific rules that apply in your region (eg bylaws related to mineral pools or geothermal safety). 5

2.0 Shallow geothermal wells IN THIS SECTION: 2.1 Surface well maintenance 6

2.0 Shallow geothermal wells This section applies to any surface casings, annulus cement, outer cement circle, and shallow cellars. It covers the wellhead valves, flanges, fittings, and spools. Maintain and abandon each well according to NZS 2403 Code of practice for deep geothermal wells or WorkSafe s good practice guidelines Shallow Geothermal Well Safety available at: worksafe.govt.nz 2.1 Surface well maintenance Keep the site area clear of any plant growth which could enhance corrosion or inhibit access to the well or the erection of workover equipment. Site drainage should prevent surface run-off entering the cellar or accumulating around the well at ground level. Make sure a suitably qualified and experienced person carries out any maintenance. Wellhead maintenance Inspect and make sure the wellhead and it s steel surfaces are substantially free of corrosion. Remove and assess the depth of corrosion if it has formed and carry out maintenance. Monitor outer casings, outer cement, annulus cement, and outer casings for corrosion and deterioration and any defects. Repair them as soon as practicable. If protective paint systems require renewal, remove all defective areas by wire brushing or, if necessary, by sandblasting, before applying fresh coatings. If severe casing corrosion is apparent or you suspect it s on the near outer casings, remove the outer casings until you can expose sound casing. Sandblast and paint the exposed casing and reinstate the outer casings, outer cement, and annular seal. Inspect all valves, fittings, glands, and flanged fittings for leaks of geothermal fluid. Repair them as soon as practicable. If possible, regularly monitor the wellhead pressure. Carry out wellhead pressure monitoring on a six-monthly basis, or more frequently if reservoir conditions are not static. For more information about wellhead maintenance, refer to NZS 2403. 7

2.0 Shallow geothermal wells Equipment maintenance Make sure your equipment is free of leaks and in sound operating condition. The failure of this equipment will affect the well s integrity. Check for any deposits of dissolved solids as they may prevent the correct functioning of some equipment, particularly pressure-relief valves. Stop leaks past gate seats, valve stems and flange seals by operating the valve, injecting, replacing the sealant, or evenly tightening the flange s studs. If this does not stop the leak, further controls are in WorkSafe s good practice guidelines Shallow Geothermal Wells available at: worksafe.govt.nz 8

3.0 Geothermal heating equipment IN THIS SECTION: 3.1 Supply pipework 3.2 Plant equipment 3.3 Hot water system 3.4 Mineral pools 3.5 Effluent pipework 3.6 Steam boxes, drying, and other uses 9

3.0 Geothermal heating equipment This section provides guidance on different plant, equipment, and geothermal heating systems. For more information about geothermal heating equipment, refer to NZS 2402P which applies to commercial and residential heating equipment that draws from Rotorua s geothermal field. 3.1 Supply pipework Supply valve Do not use a master valve to regulate well flow. If you don t have a flow control device, use a suitably rated supply valve to control the flow of geothermal fluid. Inspect and test the supply valve once every six months. Acceptable flow control devices in place at a supply valve include: orifice plates flow restrictors (typically a short section of small-diameter pipe) control valves. Use suitable materials Use appropriately rated piping with welded, flanged, or threaded joints. Use carbon steel or galvanised piping. The design should be simple, with straight lengths of pipe, adequately supported and that allow for thermal expansion. Fit all take-offs from the supply line with isolation valves located as close as possible to the main supply line. Workmanship Construct all plant in accordance with sound geothermal engineering practice and workmanship. Conditions of pipework Assess piping for corrosion. Pay particular attention to pipework encased in pumice insulation and underground pipework. As part of maintaining the pipework, check the joints for any leaks. Protection from burn injury Provide lagging for exposed pipework with surface temperatures above 70 degrees Celsius ( C). 10

3.0 Geothermal heating equipment Maintenance Check for visible leaks and corrosion, and if any pipework needs servicing. Make sure a suitably qualified and experienced person carries out any maintenance. 3.2 Plant equipment Suitable location Make sure there is adequate access and egress to the plant equipment. Do not locate the: heat exchanger in a habitable building plant equipment below ground level, unless you make suitable provisions to prevent and clear the area of any gas that could accumulate. Adequate ventilation Ventilation in the plant room should be cross-flow and of adequate design to clear any accumulation of gas. Permanently fix vents and make sure they are not able to be closed. Any vents and extraction should be at ground level. Consider installing shaker systems to disrupt the water surface and prevent H 2S from accumulating. Check the pipework s design Check that the system is designed to a minimum pressure of 1.5 times the maximum discharge pressure of the well. Make sure there is adequate room for thermal expansion in the system, and that connections between primary and secondary systems are designed according to sound geothermal engineering practice. Workmanship/engineering practice Make sure all connections are welded, flanged or threaded and all components, valves and pipework are pressure rated and certified. Use thread tape on joints. Use suitable materials Use stainless steel seats in temperature pockets. Assess the materials used on plate exchanger plates in low-pressure systems, rubber is adequate; in high-pressure systems, use heat-resistant gaskets. Maintenance Check the overall condition of the system, and specifically check the system for fluid or gas leaks. Make sure a suitably qualified and experienced person carries out any maintenance. Isolation valves Check valves for appropriate pressure ratings. Make sure there is an isolation valve on the inlet and outlet side of the heat exchanger. Make sure the valves are accessible and operable. 11

3.0 Geothermal heating equipment Control the temperature Install a suitable temperature control device on the effluent line from the heat exchanger. This device should control the temperature of fluid in the secondary system. The temperature control device may be any of the following: automatic control valve remote-sensing thermostatic valve self-acting valve. Make sure there is a temperature gauge to show the temperature of the fluid in the system. Safety shut-off device Install an approved safety shut-off device on the inlet line to shut off the geothermal supply if the temperature in the system rises above a safe pre-set level. Fit a strainer To prevent the valve blocking up, install a strainer on the effluent line upstream of the control valve. The strainer will require regular servicing to function properly. Pipe colour coding and identification Pipe colour coding is only applicable to commercial systems. Make sure that you can easily identify the geothermal pipes from the town supply water. 3.3 Hot water system Use suitable materials Use appropriately rated piping for the hot water system, with welded, flanged or threaded joints that allow for thermal expansion. Check the design Check to make sure the system is designed in accordance with sound engineering practice. Control the discharge temperature Fit a temperature control device to regulate the discharge temperature to 80 C or less. The tap water temperature of the hot water system should not exceed 55 C for public buildings or for visitor accommodation. Maintenance Check for visible leaks and corrosion, and if any equipment needs servicing. Make sure a suitably qualified and experienced person carries out any maintenance. 3.4 Mineral pools Do you need a gas separator? Assess if you need a gas separator and where it could be located. Make sure the gas separator s design is adequate to remove gas, and that the vent is functional and adequately designed. If gas is present in the geothermal fluid, make sure all geothermal water supplied to the mineral pool passes through a gas separator. 12

3.0 Geothermal heating equipment Check the pipework s design Make sure the system is designed using suitable materials. Pipework from a gas separator needs to maintain a water seal to prevent gas entrainment in the water. Geothermal supply is only to be cascaded after the primary exchanger if an approved low-temperature gas separator is installed. Minimise the risk from burns Assess the position and location of the pipeline to determine if there is a risk from burn injury. First try eliminating any burn injury risk. If elimination is not possible, apply shielding or insulation to minimise the risk. Maintenance Check for visible leaks and corrosion, and if any equipment needs servicing. Make sure a suitably qualified and experienced person carries out any maintenance. Is there adequate ventilation? Check the bathhouse s design to determine if cross-flow ventilation is adequate at floor and roof level. Ventilation should be permanent. Check the H 2 S level above pools and particularly above the pool overflow pipe to waste; the H 2 S level should be less than 5 ppm. A shaker system to continually break up the water surface can help in dispersing H 2 S. Check that the sides of pool are not too high to allow gas accumulation (the height of the sides above the water line should not exceed 100 mm). Provide adequate non-slip areas (steps, wet areas, etc). Check the cold water supply Check and make sure there is a cold water supply to pools for cleaning purposes and emergency use. Make sure the cold water supply is not permanently running to maintain the pool s temperature. Control the pool s temperature The pool s temperature should not exceed 40 C. Fit a tempering or mixing valve to control the temperature and make sure there is a temperature gauge to show the temperature of the mineral pool. Make sure there is no direct water supply from the geothermal well to a pool. Put up warning signs At public pools, put up suitable signs to indicate the risks of scalding from hot water and the risk of primary amoebic meningo-encephalitis (PAME). Measuring H 2 S gas To get a correct measurement of H 2 S gas levels, use fit-for-purpose equipment following manufacturer s instructions. Take the reading near the geothermal supply s inlet, above the water line, and agitate the water. 3.5 Effluent pipework Check the design Make sure the pipework is designed in accordance with sound geothermal engineering practice and workmanship, allowing for thermal expansion. 13

3.0 Geothermal heating equipment If a territorial authority s consent is applicable, there should not be any discharging to stormwater drains or sewerage drains without that consent. Use suitable materials Use appropriately rated piping with welded, flanged, or threaded joints. Maintenance Check for visible leaks and corrosion, and if any pipework needs servicing. Make sure a suitably qualified and experienced person carries out any maintenance. Minimise the risk from burns Assess the position and location of the pipeline to determine if there is a risk from burn injury. First try eliminating any burn injury risk. If elimination is not possible, apply shielding or insulation to minimise the risk. Is there adequate ventilation? Adequately ventilate all geothermal heating equipment supplied with geothermal fluid from a self-flowing well. Check the gas vent s design To minimise the risk of downwash into adjoining buildings, make sure the location and height of a gas vent pipe conforms to the following conditions: diameter and size enable a minimum efflux velocity of 15 metres per second (m/s) 3 m above the ridgeline of the nearest building at least 1.5 m from any boundary. 3.6 Steam boxes, drying, and other uses Check the design Check that the design of the equipment is fit-for-purpose and clean. The equipment should use a heating coil rather than raw steam. A steam box should not to be located in an enclosed building. Check the materials Check the materials used. Make sure the system uses appropriately rated piping with welded, flanged, or threaded joints. Maintenance Check the overall condition of the system, and specifically check the system for fluid or gas leaks. Make sure a suitably qualified and experienced person carries out any maintenance. Isolation valve Check to make sure an isolation valve is fitted, functional, and serviced. 14

Appendices IN THIS SECTION: Appendix A: Shallow geothermal well systems template Appendix B: Monthly/weekly/daily registers Appendix C: More information 15

Appendices Appendix A: Shallow geothermal well systems template Make sure a suitably qualified and experienced person completes and signs this. Name: Address: Production well number: Reinjection well number: Heating engineer: Address: Work phone: Mobile phone: 1. Is geothermal system included in the health and safety management plan hazard register? Yes No 2. Does the geothermal system comply with NZS 2402P Code of Practice for Geothermal Heating Equipment in Rotorua and WorkSafe s guidelines Shallow Geothermal Wells? Yes No 3. Are mineral pools included in the system? Yes No I, certify that this geothermal system complies with the Geothermal Energy Regulations 1961 and relevant guidelines. Signature: Date: DD / MM / YEAR 16

Appendices Appendix B: Monthly/weekly/daily registers Complete this register in the timeframes indicated. Daily checklist 1. Are H2S levels less than 10 ppm or less than the territorial authority s requirement (if less than 10 ppm)? DAY Indicate Yes (Y) or No (N) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Weekly checklist WEEK Indicate Yes (Y) or No (N) 1 2 3 4 5 6 7 8 9 10 11 12 13 1. Is the system free of visible leaks (fluid/steam/gas)? 2. Are all valves operable and efficient? 3. Is the hot water from the tap 55 C maximum (accommodation and public buildings only)? 4. Is well-head pressure monitored? Monthly checklist MONTH 1 2 3 4 1. Is the heat exchanger s room adequately ventilated? Yes No Yes No Yes No Yes No 2. Is the installed strainer regularly cleaned out? Yes No Yes No Yes No Yes No 3. Are the wellhead and components corrosion-free? Yes No Yes No Yes No Yes No 17

Appendices Appendix C: More information Local Council Your council might have additional rules that you need to meet. Check with your local council for specific rules that apply in your region. For example, check if you need to comply with any geothermal bylaws from Rotorua Lakes Council or Bay of Plenty Regional Council. New Zealand legislation To access all legislation including Acts and regulations visit the New Zealand Legislation website: www.legislation.govt.nz The Institution of Professional Engineers New Zealand (IPENZ) A list of competent engineers can be found on the IPENZ website, under the Chartered Professional Engineers (CPEng) Register available at: www.ipenz.nz WorkSafe New Zealand For information and guidance about health and safety visit WorkSafe s website: worksafe.govt.nz or call 0800 030 040. For information and guidance specifically about electrical or gas safety visit WorkSafe s website: www.energysafety.govt.nz or call 0800 030 040. Standards NZS 2402P Code of practice for geothermal heating equipment in Rotorua NZS 2403 Code of practice for deep geothermal wells NZS 4441 Swimming Pool Design Standard NZS 5826 Pool Water Quality Guidance Introduction to the Health and Safety at Work Act 2015 WorkSafe New Zealand: worksafe.govt.nz Consents and Reports Required by the Geothermal Energy Regulations 1961 WorkSafe New Zealand: worksafe.govt.nz Shallow Geothermal Well Safety WorkSafe New Zealand: worksafe.govt.nz 18

Disclaimer WorkSafe New Zealand has made every effort to ensure the information contained in this publication is reliable, but makes no guarantee of its completeness. WorkSafe may change the contents of this guide at any time without notice. This document is a guideline only. It should not be used as a substitute for legislation or legal advice. WorkSafe is not responsible for the results of any action taken on the basis of information in this document, or for any errors or omissions. ISBN: 978-1-98-852762-8 (online) Published: March 2018 Current until: 2020 First edition published in 2005 by the Department of Labour PO Box 165, Wellington 6140, New Zealand worksafe.govt.nz Except for the logos of WorkSafe, this copyright work is licensed under a Creative Commons Attribution-Non-commercial 3.0 NZ licence. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc/3.0/nz In essence, you are free to copy, communicate and adapt the work for non-commercial purposes, as long as you attribute the work to WorkSafe and abide by the other licence terms. WSNZ_2915_Mar 18

ISBN 978-1-98-852762-8 (online) Level 6, 86 Customhouse Quay PO Box 165, Wellington 6140 0800 030 040 worksafe.govt.nz