Model 300 Dispensing Systems. Systems User Guide

Similar documents
Tridak Model 1050 User Guide

Tridak Model 1060 User Guide. Syringe Filling System

Loctite Integrated Semi-Automatic Dispenser Dual Channel with Low Level Sensor

EQUIPMENT Operation Manual

Techcon Systems TS1258 Pressure Pot

Techcon Systems TS1254 Pressure Pot

Loctite EQ VA25 Dispense Valve 50 Bar IDH Number EQUIPMENT Operation Manual

Pressure Dump Valve Service Kit for Series 3000 Units

B84G - Excelon Plus Modular System General purpose filter/regulator

Liquid Level Controllers

Dispensit. Single-Component Metering and Dispensing Valves

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

MANUAL BE SERIES Test Benches

Pressure Dump Valve Service Kit for Series 2300 Units

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

Type 4708 Supply Pressure Regulator

R84G - Excelon Plus Modular System Pressure regulators

OWNER S TECHNICAL MANUAL

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

Hydraulic hand test pump Models CPP700-H and CPP1000-H

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

CSA Sample Draw Aspirator Adapter Operator s Manual

Pneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar)

2K 600mL Dispense Guns with Built-In Retainers

B84G - Excelon Plus Modular System General purpose filter/regulator

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Type 4708 Supply Pressure Regulator

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Model 130M Pneumatic Controller

XpressFill XF2500 Counter Pressure Filler. Operating Instructions

Ultra 870 Dispenser. Ultra 870. User s Guide. Electronic pdf files of EFD manuals are also available at A NORDSON COMPANY

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

Autocalibration Systems for In Situ Oxygen Analyzers

Airpel -FFR Overview PUB# FFRP-04R. Airpot, Airpel, and Anti-Stiction are registered trademarks of Airpot Corporation

Standard Grout Header. Protected Pressure Gauge. High Pressure Gauge. In-Line Grout Header. Inline Protected Pressure Gauge

Instruction Manual Updated 7/26/2011 Ver. 2.2

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

ROUGHNECK II Pumpless Drain

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and 8900

Masoneilan* 78 Model Air Filter Regulator

A E R O S PA C E M E D I C A L

Schroeder Check Test Point System

PRESSURE COMPARATOR 10000PSI 700bar. Operator Instructions CRYSTAL. engineering corporation

Type R622 Pressure Reducing Regulator

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Dispense Valve Selection Guide

Type 4708 Supply Pressure Regulator

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified

CAST IRON VALVES FLOAT VALVE

Dräger Secor 7000 Diving Equipment and Systems

Gas and Vacuum Tubing Connection Kit for Manual Operation, No

The NAMIC Dream Kit. Single Operator Control. Reduce Contrast Waste. Less Force to Inject. Compensator * Manifold. How the Compensator Manifold Works:

ELECTRONIC PLC SERIES Test Benches

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

INSTRUCTIONS PARTS LIST

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

LEAK TROUBLESHOOTING

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

OVERVIEW METCELL SPECIFICATIONS. Lab scale nanofiltration equipment The METcell Range

OptiAir CA09 Pneumaticfluidizing

Workhorse 8 Oxygen System Model No 5665, 5673, 5679

FAULT CODE TROUBLESHOOTING INDEX

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

KJ1000 Operating Instructions & Parts Manual NSN

EQUIPMENT OPERATION MANUAL. Loctite Dispense Valve Manual

For Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor

1 8 A N D 2 8 S E R I E S

User Manual MFCS TM -EZ

H.T.S.T. EQUIPMENT TEST PROCEDURES. Field Reference. Sequence of Testing. Pasteurizer Not Operating 3, 1, 4, 2, 7, 10, 8, 5B, 5E, 5C (dual stem), 9

Instructions Parts List

EQUIPMENT. Bond-A-Matic Reservoir Systems / / / / OPERATION MANUAL

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

GILMONT ACCUCAL FLOWMETERS

Series 2G Diaphragm Actuators

Installation and Use Manual

R18 General purpose pressure regulators

Suggested Installation & Operating Instructions for Sidewinder Pumps

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Rejuvenation Instructions

MODEL MN-PWV PRESSURIZED WATER VESSEL ASSEMBLY OPERATING MANUAL

Cell Injury Controller II (CIC II)

Owner's Manual Sealweld SuperSeal II Pump

Additel 780 Series Pressure Controller

REV: 03/17. User Manual

DPC-30 DPC-100. Reference Manual

Series IRV1000/2000/3000

KEG PUMP. Range of Electric Keg Pumps

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

EQUIPMENT Operation Manual. Loctite Stainless Steel Poppet Valve Part Number

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

670 Series Panel-Mounted Loading Regulators

Pressure Sensing Valve - Model 4023

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

Precision and Instrument Regulators 1/4" port size

Instructions Parts List. Contents E. HIGH VOLUME Air Control Kits. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure

Tube Testers.

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Transcription:

Model 300 Dispensing Systems Systems User Guide

2 Model 300 Systems User Guide Contents Safety... 3 Using Safe Operating Pressures...3 Operating Specifications...3 Configuration Overview... 4 Key System Connections... 5 Dispensing Tips... 6 System Configurations... 7 A - Systems Using a Cartridge Retainer...8 Packaged Components...8 Assembled System...9 B - Systems Using a Bottle Drop-In Tank...10 Packaged Components...10 Assembled System...11 Installing the Fluid Line to the Reservoir...12 C - Systems Using a 10-Gallon Pressure Tank...13 Packaged Components...13 Assembled System...14 Installing the Fluid Line to the Reservoir...15

Model 300 Systems User Guide 3 Safety Using Safe Operating Pressures Pressurizing the components in the dispensing system beyond the maximum recommended pressure can result in the rupturing of components and serious personal injury. To minimize the risk of rupturing components and injury, do not exceed the maximum operating pressure of the components in your fluid dispensing system. Operating Specifications Recommended compressed air supply pressure to air filter/regulator = 80 to 100 psi (5.5 to 6.9 bar) Recommended pressure setting at air filter/regulator = 75 psi (5.2 bar) Maximum pressure setting at air filter/regulator = 100 psi (6.9 bar) Power required = 110V power receptacle (customer supplied)

4 Model 300 Systems User Guide Configuration Overview 1 2 3 Controls Dymax valves and digital controller provide precise and consistent actuation. Pneumatic function Footswitch, manual, or PLC controlled Easy to operate Manual or timed dispense mode Dispensing Valve & Accessories Dymax dispensing valves for handheld and bench-top applications deliver precision solutions for low- to highviscosity materials. Various style tips and accessories are also available. Reservoirs Dymax carries a variety of material reservoirs to accommodate most dispensing applications. Range of volumes from 6 oz. cartridges to 10- gallon pressure tanks Easy change-over and control

Model 300 Systems User Guide 5 Key System Connections NOTE: Figures 1-4 apply to all systems. Figure 1. Valve Air & Material Connections Figure 2. Controller Connections, Rear Panel Air in from controller Fluid in from reservoir Air out to valve Foot switch input Power supply input Air in from filter regulator Figure 3. High-Precision Regulator Connections Figure 4. Filter Regulator Supply air in Air out to reservoir Air in from filter regulator Air to controller and high-precision regulator for reservoir

6 Model 300 Systems User Guide Dispensing Tips A variety of both needle and taper dispense tips in various lengths, gauges, and shapes are available from Dymax. Tip selection is critical when precision is required and the length, shape, and size of the tip used will define the shape of the fluid deposit and the performance of your dispense system. The following tips are included with this system, and are recommended for use with the Model 300 dispensing valve. P3424 Dispensing Tip Kit for Low-Viscosity Materials (<500 cp) Part # Color Description P3171 Purple 21 GA Needle Tip P3172 Orange 23 GA Needle Tip P3233 Pink 20 GA Tapered Tip P3247 Red 25 GA Tapered Tip Additional kits are available (sold separately) for a range of applications using lower viscosity materials. For assistance in optimal tip selection, contact Dymax Application Engineering. Visit www.dymax.com/dispensing_tips to see Dymax s dispensing tip selection.

Model 300 Systems User Guide 7 System Configurations A Systems Using a Cartridge Retainer (p. 8-9) B Systems Using a Bottle Drop-In Tank (p. 10-12) C Systems Using a 10-Gallon Pressure Tank (p. 13-15)

8 Model 300 Systems User Guide A - Systems Using a Cartridge Retainer Packaged Components T16789 Reservoir Air Line Kit T17697 System User Guide T16787 3/8 OD Fluid Line Kit T15466 Valve Stand T16786 Controller Air Line Kit T11146 DVC-345 Controller Cartridge Reservoir 6 oz T15257 12 oz T14085 20 oz T15223 T16307 Filter Regulator T16629 High-Precision Regulator T15279 Lab Stand, 24"[61 cm] T17020 Model 300 Diaphragm Valve

Model 300 Systems User Guide 9 Assembled System T16307 Filter Regulator T16629 High-Precision Regulator Cartridge Reservoir 6 oz T15257 12 oz T14085 20 oz T15223 T16789 Reservoir Air Line Kit T16787 Fluid Line Kit, 3/8" OD T16786 Controller Air Line Kit T17020 Model 300 Diaphragm Valve T11146 DVC-345 Controller T15466 Valve Stand P3424 Dispense Tip Kit T15279 Lab Stand, 24"[61 cm] User Supplied Items Spare Parts 80-100 psi air supply, ¼ NPT male fitting 110V power receptacle ¼" male to ¼" quick-disconnect fitting

10 Model 300 Systems User Guide B - Systems Using a Bottle Drop-In Tank Packaged Components T17697 System User Guide T16787 Fluid Line Kit, 3/8" OD T11146 DVC-345 Controller T15466 Valve Stand T16789 Reservoir Air Line Kit T16786 Controller Air Line Kit T17020 Model 300 Diaphragm Valve T16307 Filter Regulator T17004 1-Gallon Bottle Drop-In Tank

Model 300 Systems User Guide 11 Assembled System T16307 Filter Regulator T16789 Reservoir Air Line Kit T17004 1-Gallon Bottle Drop-In Tank T16787 Fluid Line Kit, 3/8" OD T11146 DVC-345 Controller T16786 Controller Air Line Kit T17020 Model 300 Diaphragm Valve T15466 Valve Stand P3424 Dispense Tip Kit User Supplied Items 80-100 psi air supply, ¼ NPT male fitting 110V power receptacle Spare Parts ¼" male to ¼" quick-disconnect fitting

12 Model 300 Systems User Guide Installing the Fluid Line to the Reservoir Air Line Air Line Fluid Line Fluid Line Tube length from top of fitting: 14.5" End of tubing must be cut at an angle. 1-Liter Bottle 1-Gallon Bottle

Model 300 Systems User Guide 13 C - Systems Using a 10-Gallon Pressure Tank Packaged Components T17697 System User Guide T16787 Fluid Line Kit, 3/8" OD T15466 Valve Stand T16789 Reservoir Air Line Kit T16786 Controller Air Line Kit T16307 Filter Regulator T16864 10-Gallon Pressure Tank T11146 DVC-345 Controller T17020 Model 300 Diaphragm Valve

14 Model 300 Systems User Guide Assembled System T16307 Filter Regulator T16789 Reservoir Air Line Kit T16786 Controller Air Line Kit T16787 Fluid Line Kit, 3/8" OD T17020 Model 300 Diaphragm Valve T11146 DVC-345 Controller T15466 Valve Stand P3424 Dispense Tip Kit T16864 10-Gallon Pressure Tank User Supplied Items Spare Parts 80-100 psi air supply, ¼ NPT male fitting 110V power receptacle ¼" male to ¼" quick-disconnect fitting

Model 300 Systems User Guide 15 Installing the Fluid Line to the Reservoir Tube to be flush with the bottom of the lid tube 15-Liter Pail

Dymax Corporation 860.482.1010 info@dymax.com www.dymax.com Dymax Europe GmbH +49 (0) 611.962.7900 info_de@dymax.com www.dymax.de Dymax Asia Pacific Pte. Ltd. +65.6752.2887 info_ap@dymax.com www.dymax-ap.com Dymax Asia (H.K.) Limited +852.2460.7038 dymaxasia@dymax.com www.dymax.com.cn Dymax Korea LLC +82.2.784.3434 info_kr@dymax.com www.dymax.com/kr Dymax Oligomers & Coatings 860.626.7006 info_oc@dymax.com www.dymax-oc.com Dymax Engineering Adhesives Ireland Ltd. +353.1.231 4696 info_ie@dymax.com www.dymax.ie Dymax UV Adhesives & Equipment (Shenzhen) Co Ltd +86.755.83485759 dymaxasia@dymax.com www.dymax.com.cn Dymax UV Adhesives & Equipment (Shanghai) Co Ltd +86.21.37285759 dymaxasia@dymax.com www.dymax.com.cn 2013 Dymax Corporation. All rights reserved. All trademarks in this guide, except where noted, are the property of, or used under license by Dymax Corporation, U.S.A. Delrin and Teflon are registered trademarks of DuPont. Please note that most dispensing system applications are unique. Dymax does not warrant the fitness of the product for the intended application. Any warranty applicable to the product, its application and use is strictly limited to that contained in Dymax standard Conditions of Sale published on our website. Dymax recommends that any intended application be evaluated and tested by the user to ensure that desired performance criteria are satisfied. Dymax is willing to assist users in their performance testing and evaluation. Data sheets are available for valve controllers or pressure pots upon request. T17697 10/28/2013 MAN058