EVT * -Pro Electronic Valve Tester

Similar documents
What is pressure relief valve? Pressure relief valve

Total Tank Protection

SF 6 Product Guide. Gas Analysis Instruments and Accessories

Process Safety Management Of Highly Hazardous Chemicals OSHA 29 CFR

BACK PRESSURE / SUSTAINING

Chalmers & Kubeck - Certified Individual Review Test

BACK PRESSURE / SUSTAINING

The IEC61508 Inspection and QA Engineer s hymn sheet

Title: Pressure Relieving and Venting Devices Function: Ecology & Safety No.: BC Page: 1 of 7 Reviewed: 6/30/12 Effective: 7/1/12 (Rev.

Specialty Gases + World-Class Performance

Dow s New Practice for Locating Temporary Portable Buildings. P. Partridge 9/29/05 UNRESTRICTED - May be shared with anyone Slide 1

OPERATING PROCEDURES

Fully integrated solutions for improving safety, emissions control and product integrity

SV60 Safety valves. for use with steam, gas and liquids

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant

CONTROL OF HAZARDOUS ENERGY LOCKOUT/TAGOUT PROGRAM

Savard Labor & Marine Staffing, Inc. Compressed Gas Safety Program Rev3/14

DF1 and DF2 Diffusers

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

ASSE International Product (Seal) Listing Program

M-06 Nitrogen Generator (Nitrogen Making Machine)

General Duty Clause. Section 112(r)(1) of CAA. Chris Rascher, EPA Region 1

Hazardous Energy Control

RiskTopics. Lockout/Tagout October 2017

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

UNIQUE ADVANTAGES OF PIPENET

WHITE PAPER. SmartPlant P&ID Engineering Integrity 10 Example Rules

Pressure is our Business

GUIDANCE IN-SERVICE INSPECTION PROCEDURES

Gas Injection Systems

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

KOMPRESSOREN COMPRESSORS KAESER AIR SERVICE Our Services An Overview

Lockout/Tagout Program

Procedure: Pressure equipment safety

Nirvana Variable-Speed Drive, Contact-Cooled Rotary Screw Air Compressors

Compressed Gases and Cryogens

Control of Hazardous Energy Lockout / Tagout Program

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

Pressure Vessel Program

Calibration Requirements for Direct Reading Confined Space Gas Detectors

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Preventive Maintenance

DCV10 Stainless Steel Disc Check Valve for use with Condensate Pumps

623 Series Dome Load Regulators

Process Safety Management is the application of management principles and systems to the identification, understanding, and control of process

Fisher DVI Desuperheater Venturi Inline

Pressure Systems Safety Regulation

Lockout/Tagout Safety Policy

Every things under control High-Integrity Pressure Protection System (HIPPS)

AUSTRALIA ARGENTINA CANADA EGYPT NORTH SEA U.S. CENTRAL U.S. GULF. SEMS HAZARD ANALYSIS TRAINING September 29, 2011

MARKET OUTLOOK. Power Chemicals Petroleum Water/Wastewater Oil & Gas Pulp & Paper and more

RUPTURE HAZARD OF PRESSURE VESSELS

Pressure & Flame Protection

Contact Information. Progressive Optimization Service. We Provide: Street Bay #2. Grande Prairie, AB T8V - 4Z2

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

Energy Control. Suite 2A, 55 Frid Street Hamilton, ON L8P 4M3 office: cell:

API MPMS Chapter 17.6 Guidelines for Determining the Fullness of Pipelines between Vessels and Shore Tanks

Fig.1. September, 2017 An Äager Brand Storagetech tank equipment may saved the entire storage tank refinery of Grupsoil in Colombia.

This written Compressed Gas Plan is kept at the corporate office and in the written Safety & Health Program.

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual

Verification Of Calibration for Direct-Reading Portable Gas Monitors

DUQUESNE UNIVERSITY LOCKOUT/TAGOUT PROGRAM

SAFETY DIRECTIVE 2.0 DEPARTMENTS AFFECTED. This Administrative Directive shall apply to all Town of Marana departments and employees.

Wireless I/O, Connecting Remote Sensors in a Wide Range of Environments

Hazard Communication Program

Drilling Equipment Services

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

EXAMPLES OF COMPLIANCE METHODS FOR MONITORING AND RECORDKEEPING RCRA SUBPARTS BB AND CC. Tennessee Operations Eastman Chemical Company

Hazardous Waste Training Plan. Supersedes: 02/15/16 (Rev.02) Preparer: Owner: Approver: EHS Team Member EHS Team Member EHS Manager

Pressure on Demand. Air Pressure Amplifiers

V MW. Exceptional performance and reliability at high-wind-speed sites. vestas.com

Connect with Confidence NO POWER NO PROBLEM

Lockout - Tagout. Control of Hazardous Energy OSHA Standard

DIGITAL SOLUTIONS TRAINING CATALOGUE. QRA and CFD simulation. Phast, Safeti and KFX SAFER, SMARTER, GREENER

Avoiding Short Term Overheat Failures of Recovery Boiler Superheater Tubes

Understanding safety life cycles

Application Note AN-107

Improve Reliability of Turbomachinery Lubrication and Sealing Systems

Ultima. X Series Gas Monitor

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Lockout / Tag out Program

PMI ADVANCED AUTOMATED HYDRAULIC PRESSURE LEAK TESTER APCS-H-60K. Not just Products... Solutions!

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Safety Engineering - Hazard Identification Techniques - M. Jahoda

Release: 1. UEPOPL002A Licence to operate a reciprocating steam engine

ISS Safety Rules. Make safety second nature

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

PAGE 1 OF 7 HEALTH, SAFETY & ENVIROMENTAL MANUAL PROCEDURE: S230 Lock-Out Tag-Out (LOTO) Program REV 4.0 8/13/2012

Safe Work Practices and Permit-to-Work System

Lockout/Tagout Training Overview. Safety Fest 2013

Neil Kane Managing Director EMT UK

RESOLUTION A.567(14) adopted on 20 November 1985 REGULATION FOR INERT GAS SYSTEMS ON CHEMICAL TANKERS

6301 TYPE CAST IRON SAFETY VALVES

RESILIENT SEATED BUTTERFLY VALVES FUNCTIONAL SAFETY MANUAL

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

FUNDAMENTAL PRINCIPLES OF SELF-OPERATED PRESSURE REDUCING REGULATORS. John R. Anderson Emerson Process Management Fluid Controls Institute

Lock Out/Tag Out Control of Hazardous Energy

CONTROL OF HAZARDOUS ENERGY IN THE WORKPLACE

Transcription:

GE Oil & Gas Consolidated* Pressure Relief Valves EVT * -Pro Electronic Valve Tester In-Place Testing: No Problem Manages Global Safety Standards Tests All Manufacturers Pressure relief Valves Helps to Improve Plant Uptime and Increases Revenue

Helping You Comply With Global Safety Standards Protection from Harmful Chemical Releases Global Safety Standards like OSHA s Process Safety Management (PSM) standard was published to help minimize the consequences associated from a catastrophic release of toxic, reactive, flammable, or highly explosive hazardous chemicals. This standard covers several areas, specifically relief and vent systems and devices. It requires that written procedures, inspection and testing, [and] appropriate job skills be deployed, [and that] records and management of change be in place. Failure to do these things may result in severe consequences. Failure to comply with OSHA 29 CFR 1910.119 The Compliance Solution By integrating with ValvKeep, EVT-Pro lets you effectively manage the OSHA requirements. Since you can use the device to test any brand of pressure relief device, you don t need to manage multiple test suppliers. EVT-Pro and ValvKeep put all your documents in order, so test reports, procedures and other related documents are always available to meet compliance requirements. You are better prepared for audits and lessen the odds of receiving citations and penalties. And EVT-Pro s in-place functionality lets you keep plant operations going while it tests your valves. Process Safety Management requirements is one of the most frequent infractions. There are several reasons for this: deficient pressure relief devices, inadequate documentation, and lack of pressure relief information, procedures, or training and associated documentation. End-User Feedback In the past I had to know where my test records were located to demonstrate compliance to our local inspector; this is very important for the OSHA Process Safety Management requirement. With ValvKeep and EVT-Pro, my files are linked and updated so I have quick access to them. Several months ago an inspector was at my plant, standing next to me, asking for the paperwork on the safety relief valves. Using ValvKeep I was able to get the reports, show the inspector that the valves were all certified and had been serviced within the service guidelines. 2 GE Energy

Technologically Advanced Testing Exact Set Pressure Measurement EVT-Pro s true in-place valve testing enables you to meet local safety requirements for periodic testing and documentation without shutting down processes or dismantling or removing valves from service. You get the true hot set pressure of the valve, since it is tested under actual operating conditions. The EVT-Pro device simultaneously examines two critical variables of the relief device the upward force applied to the spindle and the actual system pressure. Using sophisticated sensors, including an acoustic device, EVT-Pro testing accurately determines the pressure relief valve s set pressure. It can also immediately sense and automatically close a relief device should it remain open during a test a unique safety feature built into the software and hardware. Along with its rugged yet lightweight test fixture, EVT-Pro has state-of-the-art electronics and proprietary software, including an interface to ValvKeep* valve maintenance and management software. You can view test results in both tabular form and colorful graphs that depict the exact set pressure, and historical data and tests are readily available 24/7 with ValvKeep software s database capabilities. See Exact Set Pressures Colorful and clear graphics assist the end user in seeing exact set pressures for the valve in test. Unique acoustic sensor feature provides confirmation of set pressure on force curves delivering confidence in each test. Feature Benefit Inline Testing Helps to Maximize Plant Uptime Pre-Planning Outages ID Problem Valves for Rapid Turnarounds Portable and Lightweight Can be Placed in Virtually Any Location in Any Plant Quickly and Easily User Defined Report Ability Get the Report You Need Industrial Computer Can be Taken Just About Anywhere in the Plant No Matter the Conditions Bench Testing Shop Testing for New and Repaired Valves Auto Shutdown Safety Feature Superb Safety Feature Allows for Closure of Valve Under Full-Lift Circumstances Interface to ValvKeep Software Comprehensive Asset Management Tool Exclusive to GE s GTC s Acoustic Indicator Device Sensor Takes Guess Work out of Determining Set Pressure ATEX/UL Certified Intrinsic Safety Certified; Available on Certain Models Test Gas, Liquid and Steam Capable of Testing all Media NBBI Accepted (Part 3, para 4.5.3) National Board Compliance ASME-Qualified Meets ASME Code Requirements Consolidated Valves - EVT * -Pro Valve Testing Device 3

How EVT-Pro Works Force Balance Analysis: F3 + F2 = F1 Normally, with the pressure relief valve online, the much stronger force of its spring -- F1 -- is all that is required to prevent system inlet pressure -- F2 -- from forcing the valve open. However, should F2 increase beyond the operational limit of the system, the valve will first simmer and then discharge. To prevent the valve from discharging during the EVT-Pro test, the GE-trained service technician introduces just enough pull on the spindle F3 -- to balance the force of the spring. This causes the disc to only crack open or simmer. F3 = Artificial pull on the spindle supplied by the hydraulic pump F1 = Spring force pressing down on the disc At this point the GTC Technician can read the set pressure from the graphic display of the EVT-Pro and determine if it is set properly. F2 = Inlet pressure pushing upward against the disc 4 GE Energy

EVT-Pro and ValvKeep Wide Scope of Documentation Record keeping is important to providing proof of your efforts to comply with Global Safety Standards, OSHA included. The scope of documentation is wide, and the more accurately records are maintained, the better it is for audits. Using EVT-Pro electronic diagnostics and ValvKeep software will lessen the stress of a Safety Inspection inspection and reduce the odds of receiving citations and penalties. As one well known safety organization, OSHA states, OSHA s primary goal is correcting hazards and maintaining compliance, rather than issuing citations or collecting penalties. Exclusively Available Through Your Local GTC * More than 125 Years of Expertise Consolidated pressure and safety relief valves from GE Oil & Gas have been available for more than 125 years. The EVT-Pro diagnostic tool is the most technologically advanced Consolidated field test device ever. EVT-Pro testing meets high standards for quality and accuracy. The GE Green Tag Center (GTC) network is the only place you can access GE s advanced technology, which tests any brand or type of pressure or safety relief valve you have. Your local GTC has the EVT-Pro electronic diagnostics, ValvKeep valve management software and factory-trained and certified technicians to meet your testing and compliance needs. Green Tag Center Network GE s GTC Network Consists of More Than 80 Facilities Located in More Than 30 Countries Worldwide Consolidated Valves - EVT * -Pro Valve Testing Device 5

Integrated Performance Solution Asset Management ValvKeep Valve Management and Maintenance Software Compliance Testing EVT-Pro Electronic Valve Test Device Pressure Relief Valves Valve Repair GTC Green Tag Center Green Tag Center 6 GE Energy

Coal-Fired Power Plant Consolidated Valves - EVT * -Pro Valve Testing Device 7

* Consolidated, EVT, Green Tag Center, and ValvKeep are trademarks of the General Electric Company. Other company names and product names used in this document are the registered trademarks or trademarks of their respective owners. 2012 General Electric Company. All rights reserved. GEA19101 08/2012