Contractors' Code of Safe Practice

Similar documents
Contractor handbook. Purpose

Contractor Code of Conduct

Permit-To-Work Guidance and Templates

Contractor / Exhibitor Handbook

Health & Safety Contractor rules

2.0 Management Systems and Documentation

IMMANUEL CHURCH, CHICHESTER HEALTH AND SAFETY POLICY

HEALTH & SAFETY AND ENVIRONMENTAL POLICY

Contractor Control Procedures. Contractor Control Procedures. Working Together. November Borders College 24/11/2014.

Fire Safety Hot Work Permit Policy/ Procedures

Rockhampton Office Brisbane Office Tarong Site. Barron Gorge Hydro PS Kareeya Hydro PS Mica Creek PS

Module: Permit to work System

CONTRACTOR SAFETY RULES

RISK ASSESSMENT A UNIVERSITY GUIDE TO PRACTICAL RISK ASSESSMENT UNDER THE MANAGEMENT OF HEALTH AND SAFETY AT WORK REGULATIONS 1992

Instructions for the Use of the Excel Spreadsheet. There are Three tabs at the bottom of this worksheet. Instructions tab is the one you are reading

Guidance for Exhibitions

Safety Risk Assessment Roofing Works / Surveying / Inspections

Welding, Cutting, and Brazing

Key Technology, Inc. Confined Space Entry Program. July, 2017

7 Hazard assessment 8 Worker participation 9 Hazard elimination and control

Working safely in an engineering environment

List all key terms and acronyms used in the procedure, and their definitions.

Understanding health and safety in gas utilisation

EXHIBITION Guide. Roles and Responsibilities OS11. A handbook for exhibitors and contractors

UNIVERSITY OF BATH HEALTH & SAFETY STANDARD Confined Spaces

Low Voltage Electricity System Safety Rules & Associated Safety Guidance

CITB Construction site safety update

U.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL

Working Alone Safety Program

Safety Manual Section 6 Confined Space

To comply with the OHS Act, the responsible manager must carry out and document the following:

POTENTIAL HEALTH & SAFETY HAZARDS

Estates and Facilities Management Policy for Working in Confined Spaces

LONE WORKING HEALTH AND SAFETY GUIDANCE

Singapore Turf Club s In-House Rules and Regulations (for the Contactor)

Contractor s HSE BOOK

HSE guidelines. SMay 2015 ELECTRICAL SAFETY HSE LIFE THE NATIONAL OIL&GAS INDUSTRY STANDARD FOR PROFESSIONALS

SOP. Working in Confined Spaces

Code of Practice and Instructions to Contractors Working for Viridor

Safety Services Guidance. Guidance on: The Provision and Use of Work Equipment Regulations 1998 (PUWER)

CALIFORNIA STATE UNIVERSITY, LOS ANGELES WELDING, CUTTING, AND HOT WORK OPERATIONS. October 2007

Safe work method statements

Hazard Identification and Risk Assessment Form. Risk Assessment

A MESSAGE FROM THE MD

A Checklist for a Health and Safety Risk Assessment

TRADE AREA: ELECTRICAL INDUSTRY

SAFETY TRAINING LEAFLET 02 BASIC RULES FOR SAFETY AND GOOD HOUSEKEEPING

Risk assessment part 1 of 3

Method Statement: Testing Dry Riser System

Potential risk of injury to staff

Rainy River District School Board SECTION 7

Working in Confined & Enclosed Space Policy

CP10 Sensor Installation and Maintenance Instructions

Risk Controls Proposed: (in hierarchy order from the most preferred control)

PSSI 36 General Confined Spaces, Tunnels, Culverts and Similar Spaces

TABLE OF CONTENTS PART 2 - CONFINED SPACES

CONFINED SPACE PROGRAM

Harbour Town Gold Coast Site Induction

CONTRACTOR WHS HAZARD STANDARD CONFINED SPACE EXTERNAL USE ONLY

Hampstead Hill School Health and Safety Policy: Confined Spaces

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

SAFETY POLICY AND PROCEDURE MANUAL All Euramax Subsidiaries. Number K-3.0 Welding Safety Procedures

OSHA Federal Standards October 1, 2016 September 30, 2017

POLICY & PROCEDURE #502 EFFECTIVE DATE: 6/5/02 LAST REVISED: 7/12/12 LAST REVIEWED: 7/8/15

INDUCTION PROCEDURES FOR CONTRACTORS Page 1 CONTRACTOR INDUCTION PROCEDURES

Hot Work Program. University of Wisconsin-Platteville Reviewed 4/2016

Safety Checklist for Events Held at Hillbrook

DSEAR- Storage, Use and handling of gas cylinders guidance.

Safe Work Practices / Procedures / Instruction CONFINED SPACE

OP-SF-005 Confined Space Entry

(Health, Safety, and Welfare)

Safety Inspection Report #002 for April 21, Gramatan Avenue, Mount Vernon, NY. Exterior Safety, Standpipe, and Pedestrian Safety

Confined Space Entry Program 8 CCR 5157

B S Glass Ltd Safety procedures- outsourced Workplaces

HEALTH & SAFETY HANDBOOK. Venues/HSE/08/16

Health and Safety Policy

Lenzing Life Saving Rules

FV Flash Vessel Installation and Maintenance Instructions

SAFETY POLICY AND PROCEDURE MANUAL QUESTIONNAIRE

Manual Actuated Boiler Blowdown Valves

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

DREW UNIVERSITY FALL PROTECTION PROCEDURE (DRAFT 12/11)

New Hire Safety Orientation. Welcome to Flexicrew, our number one priority is you and your safety.

Handout Activity: HA107

Compressed Gasses Safety

Wilkins Safety Group

Recognition, Evaluation, and Control of Hazards

Company Policy Health & safety for work performed at Customer premises

HS26 Working at Height Policy and Procedure

This written Compressed Gas Plan is kept at the corporate office and in the written Safety & Health Program.

Compliance with Health & Safety legislation

Preventive Maintenance

THE CONSTRUCTION (HEALTH, SAFETY AND WELFARE) REGULATIONS 1996

CONSTRUCTION SAFETY PROGRAM FOR. Golder Acoustics Inc.

"CONFINED SPACE ENTRY"

Section J. How to develop safety elements for project safety management system. How to develop safety elements for project SMS

Risk assessment. Assessment details. Task. Introduction. Please complete the form as fully and accurately as you can. Assessors job title

??????? is committed to providing a safe work environment for its employees and preventing occupational injuries due to falls.

THE TLC COMPANIES. Self Inspection Program. Self Inspection. Program. Revised 12/13/2002 DC00026

The Corporation of the Town of Tecumseh

Transcription:

Contractors' Code of Safe Practice Introduction As the controller of premises, The University of Hong Kong has a duty to ensure, so far as is reasonably practicable, the health and safety of all its employees, students and visitors and further, to take steps to ensure that the activities undertaken by the University do not endanger others who may be affected thereby. The University's statement of policy on health and safety recognizes these duties, and acknowledges that, unless properly planned, work involving contractors can present additional hazards. As a result this Code of Practice for Contractors has been prepared. Purpose of the Code The Code bas been operated to help Contractors and their employees to work safely, and to prevent accidents and injuries to themselves and to University personnel and property. The Code also aims to assist contractors in complying with the various statutory regulations which may affect contractor's operations, and with the terms of the contract. All Contractors working on University premises must conform with the provisions of this code. The observance of this Code, however, does not in any way relieve the contractor of his legal or contractual obligations. Contractors working on University premises must comply with the common law as it applies to the general duty of care, as well as with any statutory provisions applicable to the work they are to carry out. All Contractors and their employees should be conversant with the safety rules of the department or area in which they are working, and the Contractor's Representative whose name is to be given to Safety Office before work commences has the responsibility for ensuring that this is so. In any case of doubt regarding the application of the Code, or in any circumstances affecting safe working not covered by the Code, advice should be sought by the Contractor from Safety Office. The University expects that the requirements detailed in this Code have been adequately considered and provisions made for compliance are well taken care of in the preparation of the tender by the Contractor. In the event that any part of the Code where applicable is not followed, work will be stopped by DoS until the matter is corrected without detriment to the University. Starting Work Before work commences on each location, the Safety Office must be informed so that the appropriate arrangements for health and safety can be made. A safe system of work must be arranged before Contractor's operations are allowed to begin. 1

Special Hazards Where Contractor's operations are expected to create special hazards, e.g. in the application of heat or naked flame process, demolition work, or the use of dangerous articles or substances, the attention of the department/area concerned and The University Safety Office must be specifically drawn to such hazards, so that adequate precautions may be taken. Contractor's employees or workers may be at risk when working in certain areas, in which case the hazards will be detailed on Part 2 of the Appendix to this Code. Certain kinds of work, e.g. the application of heat as in welding, burning or the use of flame torches, must not be carried on without first seeking such prior permission. It is the Contractor's responsibility to acquaint his supervisors, workers and employees with these requirements. Services Contractors must not connect to or interfere with the compressed air, electrical, gas or other services of The University without the express permission of the Safety Office. Tools and Equipment All plant, tools, lifting appliances & gears and equipment used by Contractors on University premises must be suitable for the work to be undertaken, must comply with all relevant legal standards and must be maintained in accordance with appropriate safety standards. Contractors may not use the University plant, tools, tackle or equipment without the express permission of the responsible University personnel or the DoS representatives. Electrical Plant and Equipment The Contractor or his employees shall not enter any substation, switch room or similar area without the permission of the Safety Office. Portable electrical tools and equipment must be efficiently earthed or of double insulated construction and all electrical leads must be undamaged and wired correctly to plugs containing correct fuses. Connections in cables are only permissible if proper plugs and sockets are used. Under no circumstances are electrical conductors to be inserted directly into socket outlets without plugs or jointed using insulating tape or chocolate box connectors. Guards, Fences, Screens and Enclosures Guards or fences must not be removed from any machinery or plant without the previous permission of an authorized person. This applies particularly to wood working machinery, e.g. circular saws being used without top guards. All Contractor's machinery and plan brought onto University premises must comply with the regulations relating to that type of equipment and must, where appropriate, be securely guarded or fenced. 2

Where the Contractor is carrying on work on University premises such as the breaking or dressing of stone or concrete, grinding of metals, etc., he is responsible for the installation and maintenance of such dust screens and protection enclosures as may be required to protect University staff, dependents, students and visitors. Work Above Ground When work by the Contractor involves the erection of any scaffold, support, or similar structure, be is responsible for the incorporation, in addition to the safety of the above, of features such as 'fans', walkways, covers, guardrails, warning lights, etc. as may be necessary for safety, not only for the persons working on the scaffold roof or high place but also for the persons walking below. The attention of Contractors is drawn to the special risks attached to roof and other work above ground, and to the fact that some University buildings do not incorporate roof edge protection. In these cases, and in all cases where there is the risk of falls from above ground, it is the responsibility of the Contractor to take such precautions as are necessary for the safety of his workers or employees, and of others who may be endangered by their activities. Such precautions may include temporary guard rails, barriers or fences, fall arrest system, safety harnesses and safety belts. Ladders must be secured so as to prevent slipping. Work platforms or scaffolds are to be used as far as practicable. Notices are to be provided instructing those below what action to take rather than a vague 'Danger' indication. If there is a risk of debris or tools falling, or scaffolding falling during erection or dismantling the area below should be sealed off using fences, boards or by bright PVC tape (e.g. black and yellow stripes), minimum size (50 mm width). Confined Space Where contractor employees need to enter water tanks the Contractor is reminded that these are defined as "confined spaces" and consequently he should ensure compliance with the F & IU (Confined Spaces) Regulation. Control of Pollution Contractors may not deposit any waste, chemical, or any other, substances whatsoever into drains on University premises, unless permission has been given by the Safety Office. Fire The use of flame torches or the application of heat as in welding or burning, is prohibited in many areas of The University for a variety of reasons. Contractors and their employees must seek prior permission for these activities from the Safety Office, but in the absence of any specific restrictions, must assume that such process is prohibited. Contractors are responsible for the provision of suitable and sufficient fire-fighting equipment appropriate to the work involved. Contractors and their employees should on arrival at the work site, check for the following fire safety matters: 3

The nearest means of escape in case of fire. The location, type, and method of operation of the nearest fire fighting appliance(s). The location and method of operation of the nearest fire alarm. Contractors must obey fire alarm signals whilst on University premises. Contractors shall take measures to ensure their workers start evacuation on hearing the continuous ringing of the fire alarm or flashing of the visual fire alarm. During work on site Contractors must not lock, block or obstruct existing fire exits or remove fire doors. Personal Protection The Contractor is responsible for providing for his employees such personal protection as may be required for the work such as, for example, eye protection, head protection, respirators and breathing apparatus. Asbestos If, during the course of a contract the work involves or is likely to involve disturbing asbestos in such a way as to give rise to dust, the Contractor must cease work, withdraw his employees from the area and report immediately to the Safety Office. Highly Flammable Liquids Many paints, thinners, solvents, adhesives and cleaning fluids present a serious risk of fires and explosions due to the ignition of vapour. Every effort must be made by Contractors to use non-flammable alternatives. Where the use of highly flammable liquids is unavoidable, Contractors are responsible, in liaison with any University Department affected and with the Safety Office, for establishing and maintaining a safe system of work designed to prevent fires and explosions. Gas Cylinders Oxygen and Acetylene gas cylinders present a high fire risk and the minimum quantity only should be brought onto site. Bottles should be kept upright in properly designed trolleys and turned off at the main valve when burning/cutting operations are completed and last thing at night. House Keeping The Contractors are to keep their own working environment free from rubbish, equipment and waste so that a safe passage to workmen can be maintained and the risk from fire is kept to a minimum. Flammable waste such as polystyrene, sawdust, paper etc. must be removed on a DAILY basis. 4

香港大學 The University of Hong Kong 安全事務處 Safety Office Appendix to Contractors' Code of Safe Practice The work described in Part 1 is to be undertaken by Contractor's personnel. To secure the health and safety at work of contractor's employees, and to ensure that contractor's activities do not endanger University staff, this form should be completed as follows: Part 1: Part 1 BY SAFETY OFFICE Part 2 BY UNIVERSITY DEPARTMENT/AREA AFFECTED Part 3 & 4 BY CONTRACTOR (a) DEPARTMENT/LOCATION (b) DESCRIPTION OF WORK (c) AREA(S) AFFECTED BY CONTRACTOR'S OPERATIONS (d) EXPECTED/ACTUAL DATE OF COMMENCEMENT OF WORK (e) ESTIMATED DURATION OF WORK (f) HOURS OF WORK (DAILY) (g) CONTRACTORS HAVE BEEN GIVEN THE INFORMATION IN PART 2, AND HAVE BEEN HANDED THE UNIVERSITY CODE OF PRACTICE FOR CONTRACT OPERATIONS (h) NAME OF CONTRACTOR (i) CONTACT (NAME AND POSITION) (j) SIGNED (FOR THE UNIVERSIY) 1 Contractors Code of Practice Form May2011 P O K F U L A M R O A D, H O N G K O N G T E L : ( 8 5 2 ) 2 8 5 9 2 4 0 0 F A X : ( 8 5 2 ) 2 8 5 8 7 1 5 9 Printed on environmental friendly paper

香港大學 The University of Hong Kong 安全事務處 Safety Office Part 2: DEPARTMENTAL/AREA HAZARDS (a) SPECIAL HAZARDS AND THEIR LOCATION TO WHICH CONTRACTOR'S ATTENTION SHOULD BE DRAWN (b) HAZARDS PARTICULAR TO THIS DEPARTMENT/AREA (c) GENERAL HAZARDS IN THIS AREA (d) GENERAL HAZARDS IN ADJACENT AREAS (e) TIMES AT WHICH ACCESS TO AREA/DEPARTMENT IS PROHIBITED/RESTRICTED (f) SPECIAL NOTE ANY NEW HAZARD ARISING DURING THE COURSE OF THE WORK WILL BE NOTIFIED TO THE UNIVERSITY ESTATES AND SAFETY OFFICE AT ONCE SIGN : RESPONSIBLE DEPARTMENTAL OFFICER 2 Contractors Code of Practice Form May2011 P O K F U L A M R O A D, H O N G K O N G T E L : ( 8 5 2 ) 2 8 5 9 2 4 0 0 F A X : ( 8 5 2 ) 2 8 5 8 7 1 5 9 Printed on environmental friendly paper

香港大學 The University of Hong Kong 安全事務處 Safety Office Part 3: CONTRACTOR'S ACCEPTANCE NOTICE HAS BEEN RECEIVED OF THE CONDITIONS AND CIRCUMSTANCES AFFECTING HEALTH AND SAFETY DESCRIBED IN PART 2. THESE HAVE BEEN COMMUNICATED TO OUR EMPLOYEES WHO WILL CARRY OUT THE WORK. THE WORK WILL CAUSE THE FOLLOWING OPERATIONAL HAZARDS (Enter NONE if appropriate) SPECIAL NOTE ANY NEW HAZARD ARISING DURING THE COURSE OF THE WORK WILL BE NOTIFIED TO THE UNIVERSITY SAFETY OFFICE AT ONCE ANY OPERATION INVOLVING THE APPLICATION OF HEAT/FLAME WILL REQUIRE A SIGNED HOT WORK PERMIT BEFORE ANY WORK COMMENCES ON SITE SIGNATURE POSITION DATE Part 4: SERVICES USED Indicate service(s) which will be required by ticking appropriate box and state what used for. [ ] Gas, Propane, Acetylene etc. [ ] Water [ ] Electricity [ ] Compressed Air [ ] Toilet/Foul Drainage [ ] Other For /ii May 2011 3 Contractors Code of Practice Form May2011 P O K F U L A M R O A D, H O N G K O N G T E L : ( 8 5 2 ) 2 8 5 9 2 4 0 0 F A X : ( 8 5 2 ) 2 8 5 8 7 1 5 9 Printed on environmental friendly paper